a <br />ELECTRICAL SYMBOL LEGEND <br />WIRING AND POWER NOS: <br />SYMBOLS SHOWN ARE FOR <br />REFERENCE PURPOSES ONLY. <br />-e WALL OUTLET BOX AND SINGLE RECEPTACLE ALL OF THESE SYMBOLS MAY <br />NOT BE USED FOR THIS <br />=0 WALL OUTLET BOX AND DUPLEX RECEPTACLE I PROJECT. <br />TWO GANG WALL OUTLET BOX AND (2) DUPLEX RECEPTACLES <br />WALL OUTLET BOX AND DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER <br />WALL OUTLET BOX AND DUPLEX RECEPTACLE WITH TOP HALF SWITCHED <br />WALL OUTLET BOX AND DUPLEX RECEPTACLE CONNECTED TO EMERGENCY SYSTEM <br />m CEILING OUTLET BOX AND SINGLE RECEPTACLE <br />® CEILING OUTLET BOX AND DUPLEX RECEPTACLE <br />=9 WALL OUTLET BOX AND GFCI DUPLEX RECEPTACLE <br />-@ WALL OUTLET BOX AND GFCI DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER <br />=@S WALL OUTLET BOX AND DUPLEX SAFETY RECEPTACLE <br />=@T WALL OUTLET BOX AND DUPLEX TWIST -LOCK RECEPTACLE <br />=@WP WALL OUTLET BOX AND GFCI DUPLEX RECEPTACLE WITH WEATHERPROOF COVER <br />® WALL OUTLET BOX AND SPECIAL PURPOSE OUTLET AS NOTED ON PLANS <br />® FLUSH FLOOR OUTLET BOX WITH DUPLEX RECEPTACLE <br />® FLUSH FLOOR OUTLET BOX WITH (2) DUPLEX RECEPTACLES <br />® FLUSH FLOOR OUTLET BOX WITH DUPLEX RECEPTACLE AND TELECOMMUNICATIONS OUTLET <br />10 FLUSH WALL JUNCTION BOX AND BLANK PLATE <br />m JUNCTION BOX AND BLANK PLATE ABOVE CEILING <br />m SURFACE MOUNTED JUNCTION BOX AND BLANK PLATE <br />91WP SURFACE MOUNTED WEATHERPROOF JUNCTION BOX AND COVER <br />mPB FLUSH GRADE FIBER COMPOSITE PULL BOX AS NOTED <br />,0' MOTOR CONNECTION AS NOTED <br />0 FLUSH SHUNT -TRIP BUTTON, MOUNTED 80" TO TOP <br />® CONTROL AND/OR POWER EQUIPMENT CONNECTION <br />TIME CLOCK <br />® PHOTO CELL <br />0-' DISCONNECT SWITCH, SIZE AS NOTED <br />-_ 120/208V BRANCH CIRCUIT PANELBOARD, SURFACE MOUNTED <br />120/208V BRANCH CIRCUIT PANELBOARD, FLUSH MOUNTED <br />-� 277/480V BRANCH CIRCUIT PANELBOARD <br />QT TRANSFORMER <br />8 AUTOMATIC TRANSFER SWITCH <br />BRANCH CIRCUIT HOMERUN WITH PANEL NAME AND CIRCUIT NUMBER, <br />q_3� QUANTITY OF ARROWHEADS DENOTES QUANTITY OF BRANCH CIRCUITS <br />BRANCH CIRCUIT WIRING, PROVIDE QUANTITY OF CONDUCTORS REQUIRED <br />FOR CIRCUITING AND SWITCHING INDICATED ON PLANS <br />POWER LEG ONLY (NO SWITCH LEG BETWEEN ROOMS) <br />--3 CONDUIT CAPPED OFF <br />-� CONDUIT CONTINUED <br />0 CONDUIT RUN UP <br />--0 CONDUIT RUN DOWN <br />-* GROUND OR GROUND ROD AS NOTED <br />LIGHTING AND SWITCHING <br />CEILING MOUNTED LIGHT FIXTURE, REFER TO LIGHT FIXTURE SCHEDULE <br />0 CEILING MOUNTED RECESSED DOWNLIGHT FIXTURE, REFER TO LIGHT FIXTURE SCHEDULE <br />0 CEILING MOUNTED RECESSED WALLWASH FIXTURE, REFER TO LIGHT FIXTURE SCHEDULE <br />0 CEILING MOUNTED "CLOSE TO CEILING" FIXTURE, REFER TO LIGHT FIXTURE SCHEDULE <br />+ PENDANT MOUNTED LIGHT FIXTURE, REFER TO LIGHT FIXTURE SCHEDULE <br />TRACK LIGHT FIXTURE WITH HEADS AS REQUIRED, REFER TO LIGHT FIXTURE SCHEDULE <br />FO WALL MOUNTED LIGHT FIXTURE, REFER TO LIGHT FIXTURE SCHEDULE <br />® CEILING MOUNTED LIGHT FIXTURE WITH EMERGENCY BACKUP <br />O CEILING MOUNTED RECESSED DOWNLIGHT FIXTURE WITH EMERGENCY BACKUP <br />Q WALL MOUNTED LIGHT FIXTURE WITH EMERGENCY BACKUP <br />4s;P WALL MOUNTED EMERGENCY BATTERY LIGHT FIXTURE, REFER TO LIGHT FIXTURE SCHEDULE <br />NEF.a CEILING MOUNTED EMERGENCY BATTERY LIGHT FIXTURE, REFER TO LIGHT FIXTURE SCHEDULE <br />®1 CEILING MOUNTED EXIT SIGN WITH EMERGENCY BACKUP, REFER TO LIGHT FIXTURE SCHEDULE <br />1,0+ WALL MOUNTED EXIT SIGN WITH EMERGENCY BACKUP, REFER TO LIGHT FIXTURE SCHEDULE <br />Al COMBINATION EXIT SIGN AND EMERGENCY LIGHT FIXTURE WITH BATTERY BACKUP <br />So WALL OUTLET BOX AND SINGLE POLE SWITCH ('a' INDICATES SWITCH LEG) <br />S3 WALL OUTLET BOX AND THREE-WAY SWITCH <br />SF WALL OUTLET BOX AND FAN CONTROL SWITCH <br />SD WALL OUTLET BOX AND DIMMER SWITCH AS REQUIRED FOR LOAD SERVED <br />SD3 WALL OUTLET BOX AND THREE-WAY DIMMER SWITCH <br />SM WALL OUTLET BOX WITH SINGLE POLE MANUAL MOTOR STARTER SWITCH <br />SO WALL OUTLET BOX AND DUAL TECHNOLOGY OCCUPANCY SENSOR <br />ST WALL OUTLET BOX AND DIGITAL TTMECLOCK SWITCH FOR AUTOMATIC CONTROL <br />CEILING OUTLET BOX AND DUAL TECHNOLOGY OCCUPANCY SENSOR <br />® CEILING OUTLET BOX AND DAYLIGHT HARVESTING SENSOR <br />FIRE ALARM SYSTEM LEGEND <br />[F MANUAL PULL STATION <br />n4cd WALL MOUNTED HORN WITH STROBE (cd=CANDELA RATING) <br />MOP WALL MOUNTED HORN WITH STROBE IN WEATHERPROOF ENCLOSURE <br />CEILING MOUNTED HORN WITH STROBE <br />HIM WALL MOUNTED MINI HORN <br />EMM WALL MOUNTED MINI HORN WITH STROBE <br />91 WALL MOUNTED VOICE EVACUATION SPEAKER WITH STROBE <br />(94 CEILING MOUNTED VOICE EVACUATION SPEAKER WITH STROBE <br />RD WALL MOUNTED STROBE <br />(D SMOKE DETECTOR <br />OO CO SMOKE AND CARBON MONOXIDE COMBINATION DETECTOR <br />DUCT MOUNTED SMOKE DETECTOR <br />(D HEAT DETECTOR <br />IM REMOTE DUCT DETECTOR INDICATOR LIGHT AND TEST SWITCH (NUMBER' INDICATES QUANTITY) <br />® FAN SHUT -DOWN RELAY <br />❑D ELECTROMAGNETIC DOOR RELEASE DEVICE <br />41- SMOKE DAMPER (PROVIDE BY MECHANICAL, CONNECTED BY ELECTRICAL) <br />0 FIREMAN'S PHONE JACK <br />SPRINKLER SYSTEM SUPERVISORY SWITCH CONNECTION <br />© SPRINKLER SYSTEM FLOW SWITCH CONNECTION <br />CEI CONTROL MODULE <br />FMUI MONITOR MODULE <br />® LOCK BOX <br />&M FIRE ALARM CONTROL PANEL <br />F� FIRE ALARM TERMINAL CABINET <br />% FIRE ALARM ANNUNCIATOR PANEL <br />&M DIGITAL ALARM COMMUNICATOR TRANSMITTER <br />TELECOMMUNICATION SYSTEM LEGEND <br />COMBINATION TELECOMMUNICATIONS/DATA WALL OUTLET BOX AND BLANK PLATE <br />WITH MIN. 3/4"C. TO ACCESSIBLE CEILING SPACE. COORDINATE OUTLET <br />REQUIREMENTS WITH OWNER. <br />W TELECOMMUNICATIONS WALL OUTLET BOX AND BLANK PLATE FOR WALL MOUNTED <br />TELEPHONE WITH MIN. 3/4"C. TO ACCESSIBLE CEILING SPACE. COORDINATE <br />OUTLET REQUIREMENTS WITH OWNER. <br />DATA WALL OUTLET BOX AND BLANK PLATE WITH MIN. 3/4°C. TO ACCESSIBLE <br />CEILING SPACE. COORDINATE OUTLET REQUIREMENTS WITH OWNER. <br />FLUSH FLOOR OUTLET BOX WITH POWER DEVICE AND TELECOMMUNICATIONS OUTLET <br />® WITH MIN. 3/4"C. TO ACCESSIBLE CEILING SPACE. <br />A CEILING OUTLET BOX AND BLANK PLATE WITH MIN. 3/4"C. TO TTB FOR WIRELESS <br />ACCESS POINT. COORDINATE OUTLET REQUIREMENTS WITH OWNER. <br />TV COMBINATION TELECOMMUNICATIONS/TELEVISION WALL OUTLET BOX AND BLANK <br />v PLATE. COORDINATE OUTLET AND CABLING REQUIREMENTS WITH OWNER. <br />® 3/4" PLYWOOD TELEPHONE TERMINAL BOARD, SIZE AS SHOWN ON PLANS. <br />C&C TELEPHONE TERMINAL CABINET, SIZE AS NOTED ON PLAN. <br />GENERAL NOTES <br />1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST ADOPTED EDITION OF THE NATIONAL <br />ELECTRICAL CODE (NFPA 70), AND THE LATEST ADOPTED EDITION OF THE FLORIDA BUILDING CODE. <br />2. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND COORDINATE WITH ALL EQUIPMENT <br />MANUFACTURER/INSTALLERS PRIOR TO BIDDING. <br />3. ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE LABEL LISTED BY AN <br />APPROVED THIRD -PARTY TESTING AGENCY. <br />BUILDING_ <br />4. INSTALLATION HEIGHT OF EQUIPMENT (TO CENTERLINE) ABOVE FINISHED FLOOR UNLESS NOTED <br />OTHERWISE SHALL BE: <br />RECEPTACLE = 18" <br />CLOCK = 7'-6" <br />SWITCH = 44" <br />MODULAR JACK FOR WALL MOUNTED TELEPHONE = 48" <br />MODULAR TELEPHONE JACK = 18" <br />TELEVISION OUTLET = 84" <br />COMPUTER OUTLET = 18" <br />CALL SWITCH = 44" <br />REMOTE TEST STATION FOR DUCT DETECTOR = 52" <br />C = ABOVE COUNTER BACKSPLASH, COORDINATE WITH ARCHITECTURAL ELEVATIONS AND MILLWORK. <br />5. ALL CONDUIT AND WIRING SHALL BE CONCEALED IN WALLS OR ABOVE CEILINGS UNLESS NOTED <br />OTHERWISE OR APPROVED BY THE ARCHITECT/ENGINEER. ALL DEVICE OUTLET BOXES SHALL BE <br />RECESSED UNLESS NOTED OTHERWISE OR APPROVED BY THE ARCHITECT/ENGINEER. WHERE <br />APPROVED OR NOTED SURFACE METAL RACEWAY AND DEVICE BOXES SHALL BE USED IN LIEU OF <br />CONDUIT AND CONCEALED BOXES AT NO EXTRA COST TO THE OWNER. <br />6. ALL CONDUIT ROUTING SHOWN IS APPROXIMATE ONLY. CONTRACTOR SHALL FIELD VERIFY FINAL <br />ROUTE WITH ALL OTHER TRADES AND CONDITIONS IN FIELD PRIOR TO ROUGH -IN. <br />7. CONDUIT RUNS SHOWN ARE SCHEMATIC AND DO NOT INDICATE THE NECESSARY FITTINGS AND <br />JUNCTION BOXES THAT ARE INCLUDED IN THE SCOPE OF THE WORK. <br />8. CONTRACTOR SHALL PERMANENTLY IDENTIFY ALL WIRING WITH THE SOURCE AND CIRCUIT AT ALL <br />ELECTRICAL EQUIPMENT, PULL AND JUNCTION BOXES AND ELECTRICAL TERMINATIONS PROVIDED OR <br />ASSOCIATED WITH THIS CONSTRUCTION. <br />9. COORDINATE EXACT LOCATION OF LIGHTING FIXTURES IN MECH. ROOMS/SPACES WITH DUCTWORK <br />INSTALLER PRIOR TO ROUGH -IN. LOCATE BELOW DUCTWORK(8'-0" AFF MINIMUM) CENTERED IN <br />ROOM AS MUCH AS POSSIBLE. <br />10. COORDINATE EXACT INSTALLATION REQUIREMENTS OF OUTLETS IN MILLWORK WITH ARCHITECTURAL <br />DRAWINGS, APPROVED SHOP DRAWINGS AND MILLWORK INSTALLER PRIOR TO ROUGH -IN. <br />11. VERIFY EXACT LOCATION OF ALL MECHANICAL EQUIPMENT WITH MECHANICAL INSTALLER PRIOR TO <br />ROUGH -IN. <br />12. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF ALL LIGHT FIXTURES <br />13. PROVIDE NYLON PULLSTRINGS IN ALL EMPTY CONDUITS. <br />14. COORDINATE THE EXACT LOCATION OF ALL ELECTRICAL EQUIPMENT LOCATED IN ELEVATOR MACHINE <br />ROOMS, SHAFTS AND PITS. LOCATE EQUIPMENT AS REQUIRED TO MEET APPLICABLE CODES.PROVIDE <br />AUTOMATIC DISCONNECTION OF THE ELEVATOR MAIN POWER SUPPLY (PER ANSI A17.1, RULE 102.2 <br />1987 ED.) PRIOR TO ACTIVATION OF AUTOMATIC SPRINKLER LOCATED WITHIN THE ELEVATOR MACHINE <br />ROOM, PIT OR SHAFT. COORDINATE WITH FIRE PROTECTION AND FIRE ALARM INSTALLER. <br />15. COORDINATE THE REQUIRED SIZE OF ALL CIRCUIT BREAKERS FEEDING EQUIPMENT, (I.E. MOTORS, <br />HVAC, KITCHEN EQUIPMENT, SPECIAL PURPOSE OUTLETS, ELEVATORS, OWNER FURNISHED EQUIPMENT <br />ETC. ) WITH APPROVED EQUIPMENT SHOP DRAWINGS AND OWNER REPRESENTATIVES PRIOR TO <br />ORDERING PANELBOARDS. BREAKERS SHALL BE SIZED PER THE NEC, THE EQUIPMENT NAME PLATE <br />AND MANUFACTURERS RECOMMENDATIONS. <br />16. ALL DIMMED CIRCUITS SHALL BE PROVIDED WITH DEDICATED NEUTRALS FOR EACH DIMMER AND PHASE <br />CONDUCTOR THROUGHOUT THE ENTIRE CIRCUIT. <br />17. THE POWER COMPANY SHALL BE CONTACTED WITHIN 10 DAYS OF THE AWARD OF THE CONTRACT BY <br />THE CONTRACTOR TO VERIFY THE ACTUAL AVAILABLE SHORT CIRCUIT FAULT CURRENT (AIC) AT THE <br />TRANSFORMER SECONDARY BUSHINGS. THE CONTRACTOR SHALL PROVIDE ELECTRICAL DISTRIBUTION <br />AND UTILIZATION EQUIPMENT AND PANELBOARDS WHICH HAVE AIC/WITHSTAND RATINGS GREATER THAN <br />THE AVAILABLE AIC AT EACH POINT IN THE ELECTRICAL SYSTEM. <br />18. CONTRACTOR SHALL INCLUDE IN HIS BID THE TRANSPORT AND DISPOSAL OR RECYCLING OF ALL <br />WASTE MATERIALS GENERATED BY THIS PROJECT IN ACCORDANCE WITH ALL RULES, REGULATIONS AND <br />GUIDELINES APPLICABLE. <br />19. PANEL SCHEDULES INDICATE CIRCUIT DESIGNATIONS ONLY. CONTRACTOR TO PROVIDE MATERIALS AS <br />REQUIRED WHEN NEUTRALS ARE SHARED TO COMPLY WITH NEC REQUIREMENTS. ALL SINGLE PHASE <br />MULTIWIRE BRANCH CIRCUITS SHALL BE FED VIA A TWO POLE BREAKER OR TWO SINGLE POLE <br />BREAKERS WITH AN IDENTIFIED HANDLE TIE. ALL THREE PHASE MULTIWIRE BRANCH CIRCUITS SHALL <br />BE FED VIA A THREE POLE BREAKER OR THREE SINGLE POLE BREAKERS WITH AN IDENTIFIED HANDLE <br />11E (PER NEC 210.413). <br />20. PER NEC 110.22; PROVIDE PERMANENT LABELING FOR ALL SERIES RATED PANEL ENCLOSURES TO <br />READ AS FOLLOWS: CAUTION - SERIES COMBINATION SYSTEM RATED AMPERES. IDENTIFIED <br />REPLACEMENT COMPONENTS REQUIRED. <br />21. ELECTRICAL CONTRACTOR SHALL PROVIDE FULL LIGHTNING PROTECTION SYSTEM FOR THIS PROJECT <br />PER NFPA 780. <br />GROUNDING: <br />22. ALL METAL RACEWAYS, INCLUDING CONDUIT, WIRE TROUGHS, WIREMOLD, ETC., SHALL BE GROUNDED. <br />ALL CONNECTIONS IN METAL RACEWAYS SHALL BE COMPLETED IN SUCH A MANNER AS TO MAINTAIN A <br />CONTINUOUS PATH TO GROUND THROUGHOUT THE ENTIRE LENGTH OF THE RACEWAY. <br />WIRING: <br />23. UNLESS NOTED OTHERWISE ON THE DRAWINGS OR ON THE EQUIPMENT WIRING SCHEDULE, EACH <br />BRANCH CIRCUIT HOME RUN SHALL BE THREE (3) #12 AWG THHN/THWN (1 HOT, 1 NEUTRAL & 1 <br />EQUIPMENT GROUND) IN 3/4" EMT CONDUIT. PROTECT EACH CIRCUIT WITH A 20 AMPERE, 1-POLE <br />OVERCURRENT DEVICE UNLESS NOTED OTHERWISE. COMBINED NEUTRALS ARE NOT PERMITTED. <br />24. THE USE OF 'NM' CABLE FOR BRANCH CIRCUIT WIRING IS ACCEPTABLE WHERE ALLOWED BY THE NEC <br />AND AUTHORITY HAVING JURISDICTION. <br />BDA SYSTEM: <br />25. ALL BUILDINGS WITHIN THIS PROJECT SHALL HAVE AN APPROVED THIRD -PARTY PROVIDE A SPECTRUM <br />ANALYSIS GRID TEST OF THE BUILDINGS AND PROVIDE A COPY OF THE ANALYSIS OF THE RADIO <br />SIGNAL STRENGTH AND RECOMMENDATIONS FOR THE REQUIREMENT OF A DAS/BDA SYSTEM (WHETHER <br />NECESSARY TO INSTALL) TO THE G.C. AND AHJ. IF REQUIRED TO BE ADDED, BASED ON TESTING, <br />DESIGN WILL BE PROVIDED BY OTHERS (DAS/BDA CONTRACTOR) UNDER A SEPARATE PERMIT AND IN <br />CONFORMANCE TO THE FFPC, FAC AND NFPA. FINAL TESTING WILL BE REQUIRED AT COMPLETION OF <br />THE BUILDING CONSTRUCTION PRIOR TO OBTAINING THE CERTIFICATE OF OCCUPANCY. THE SIGNAL <br />STRENGTH SHALL MEET THE REQUIREMENTS OF THE FLORIDA FIRE PREVENTION CODE 6TH EDITION; <br />NFPA 1 11.10; NFPA 72-2016 EDITION 24.5.2.2, 24.5.2.3; AND MUST BE TESTED IN ACCORDANCE <br />WITH THE PROVISIONS SET FORTH IN NFPA 72-2016 EDITION 14.4.10 (1-6) AND A14.4.10 (1-3). <br />Josep%, Laweence CSC Co <br />Consulting Ingineeps <br />1180 HARWOOD AVE., SUITE 3000 <br />ALTAMONTE SPRINGS, FLORIDA 32714 <br />TEL: 321.972.4466 <br />WWW.JLCENG.COM <br />CA NO. 28730 <br />FORUME <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />237 S. Westmonte Drive, Suite 220 <br />Altamonte Springs, FL 32714 <br />407.830.1400 <br />AA0002731 <br />www.forumarGhitecture.com <br />Zephyr <br />Commons <br />Apartments <br />City of Zephyrhills, FL <br />JLC21.0058.00 <br />Blake Lawrence Suddeth <br />P.E. #: 69060 <br />SET DISTRIBUTIONS: <br />0 SHEET REVISIONS: <br />EDITED BY: MAR/BLS <br />PROJECT N0, 4097 <br />Apartments <br />Symbols, Abbreviations, <br />and General Notes - <br />Electrical <br />E16-00 <br />