PLUMBING SPECIALTIES SCHEDULE
<br />MARK
<br />FIXTURE
<br />WASTE
<br />TRAP
<br />VENT
<br />COLD
<br />WATER
<br />HOT
<br />WATER
<br />MANUFACTURER
<br />/MODEL #
<br />DESCRIPTION
<br />SA
<br />SHOCK ARRESTOR
<br />-
<br />-
<br />-
<br />-
<br />-
<br />SIOUX CHIEF
<br />SIZE PER MANUFACTURER'S RECOMMENDATIONS. PDI CERTIFIED. WHA-1: SIZE "A",
<br />650 SERIES
<br />WHA-2: SIZE "B". SIZE PER PDI METHOD.
<br />WCO-1
<br />WALL CLEANOUT
<br />SEE DWG.
<br />-
<br />-
<br />-
<br />-
<br />ZURN
<br />CLEANOUT TEE, DURA-COATED CAST IRON BODY, GAS AND WATERTIGHT ABS TAPERED
<br />Z1446
<br />THREAD PLUG, AND ROUND, SMOOTH STAINLESS STEEL WALL ACCESS COVER WITH
<br />SECURING SCREW.
<br />ECO-1
<br />EXTERIOR CLEANOUT
<br />SEE DWG.
<br />-
<br />-
<br />--
<br />-
<br />ZURN
<br />"LEVEL-TROL" ADJUSTABLE FLOOR CLEANOUT, DURA-COATED CAST IRON BODY WITH GAS
<br />ZS1400-VP
<br />AND WATERTIGHT ABS TAPERED THREAD PLUG AND ROUND SECURED STAINLESS STEEL
<br />ADJUSTABLE TO FINISHED FLOOR WITH VANDALPROOF SCREWS.
<br />HB-1
<br />HOSE BIBB - BUILDING
<br />-
<br />-
<br />-
<br />-
<br />-
<br />ZURN
<br />ANTI -SIPHON WALL FAUCET WITH EXTERNAL VACUUM BREAKER, ALL BRONZE INTERIOR
<br />MILD CLIMATE
<br />Z1341
<br />COMPONENTS, VANDAL -RESISTANT OPERATING STEM, ROUGH BRONZE EXTERIOR AND
<br />BOX:
<br />MALE HOSE CONNECTION, LOOSE KEY HANDLE AND 3j" DEEP BOX.
<br />Z1341-BOX
<br />FD-1
<br />FLOOR DRAIN
<br />SEE DWG.
<br />-
<br />-
<br />-
<br />--
<br />ZURN
<br />DURA-COATED CAST IRON BODY WITH BOTTOM OUTLET, COMBINATION INVERTIBLE
<br />ZN415S-HD-P
<br />MEMBRANE CLAMP AND ADJUSTABLE COLLAR WITH SEEPAGE SLOTS AND "TYPE S"
<br />POLISHED NICKEL BRONZE, SQUARE HEAVY-DUTY STRAINER AND j" TRAP PRIMER
<br />CONNECTION.
<br />TPV-1
<br />TRAP PRIMER VALVE
<br />-
<br />-
<br />-
<br />1/2"
<br />-
<br />PRECISION
<br />PROVIDE FULLY ACCESSIBLE SHUT OFF VALVE TO EACH PRIMER VALVE.
<br />PLUMBING
<br />PRODUCTS
<br />PR-500
<br />TMV-1
<br />MIXING VALVE
<br />-
<br />-
<br />-
<br />1/2"
<br />1/2-
<br />SYMMONS
<br />THERMOSTATIC CONTROLLER, CHECK STOPS, REMOVABLE CARTRIDGE WITH STRAINER, S.S.
<br />7-225-CK
<br />PISTON, THERMAL MOTOR. MIN FLOW RATE .5 GPM.
<br />TMV-2
<br />MIXING VALVE
<br />-
<br />-
<br />-
<br />1"
<br />1"
<br />WATTS
<br />THERMOSTATIC CONTROLLER, LEAD FREE CAST COPPER SILICON ALLOY BODY
<br />LF1170
<br />CONSTRUCTION, SOLID WAX HYDRAULIC PRINCIPLE THERMOSTAT, INTEGRAL FILTER WASHERS
<br />AND CHECK VALVES, ADJUSTMENT CAP WITH LOCKING FEATURE. MIN FLOW RATE .5 GPM.
<br />RPBP-1
<br />REDUCED PRESSURE
<br />-
<br />-
<br />-
<br />SEE DWG.
<br />-
<br />WATTS
<br />LEAD FREE REDUCED PRESSURE ZONE ASSEMBLY WITH 2 ISOLATION VALVES AND 2
<br />BACKFLOW PREVENTER
<br />LF009
<br />BRONZE TEST COCKS. j"-2" IN SIZE.
<br />NOTES:
<br />1. ALL PLUMBING FIXTURES SHALL BE SUPPLIED WITH ANGLE STOP SUPPLY RISERS. THIS SHALL INCLUDE ALL WASHING MACHINES, DISHWASHERS & ICE MAKERS.
<br />2. PROVIDE FULLY ACCESSIBLE SHOCK ARRESTORS ON SUPPLIES TO WASHING MACHINES, DISHWASHERS & ICE MAKERS.
<br />POOL PAVILION ELECTRIC WATER
<br />HEATER SCHEDULE
<br />MARK
<br />TYPE
<br />GALLONS
<br />INPUT
<br />KW
<br />GPH REC.
<br />VOLTAGE/PHASE
<br />OPERATING
<br />DIMENSIONSL
<br />SELECTION BASED ON:
<br />UNIFORM
<br />NOTES
<br />® 90'F RISE
<br />(EIIGHT
<br />MANUFACTURER
<br />MODEL #
<br />ENERGY FACTOR
<br />EWH-1
<br />ELECTRIC
<br />1 40
<br />4.5
<br />1 21
<br />1 208 240V 10
<br />418
<br />62 H x 18 0 - TALL
<br />A.O. SMITH OR EQUAL
<br />ENT-40
<br />.92
<br />1 1. & 2.
<br />NOTES:
<br />1. PROVIDE T & P VALVE, EXPANSION CONTROL DEVICE, AND 24 GAUGE 1j" DEEP WATER HEATER DRAIN PAN WITH 1" DRAIN CONNECTION. REFER TO DETAIL
<br />2. COORDINATE WATER HEATER
<br />LOCATION AND PIPING WITH MECHANICAL PLANS,
<br />POOL PAVILION PUMP
<br />SCHEDULE
<br />MARK
<br />LOCATION
<br />GPM
<br />FT
<br />HEAD
<br />CONN. SIZE
<br />MOTOR DATA
<br />SELECTION BASED ON:
<br />NOTES
<br />OUTLET
<br />HP/WATT
<br />VOLTAGE/PHASE
<br />MANUFACTURER
<br />I MODEL
<br />CP-1
<br />I CIRCULATING PUMP 1
<br />5
<br />12
<br />3/4"
<br />1/25 HP
<br />120/10
<br />GRUNDFOS
<br />UP15-42B7
<br />1. & 2.
<br />NOTES:
<br />1. CIRCULATING PUMP SHALL OPERATE PER FBCE C404.6. PUMP SHALL START ON FLOW OF DEMAND HOT WATER AND BASED ON MAINTAINING LOOP TEMPERATURE OF 104'F.
<br />2. PROVIDE WITH AQUASTAT AND FLOW CONTROL
<br />CONNECT HOT WATER
<br />RETURN TO COLD WATER
<br />SUPPI Y TO WATFR HFATFR
<br />FLOW
<br />SOURCE OF HOT
<br />SUPPLY
<br />SEE FLOOR PLAN
<br />FOR PIPE SIZES: -
<br />PER INTERNATIONAL PLUMBING CODE 607.1.2
<br />INCLUDE THERMOSTATIC CONTROLLER FOR
<br />TEMPERED HOT WATER TO SINK
<br />PER ENERGY EFFICIENCY CODE SECTION C404.5.1.
<br />ROUTE HOT WATER SUPPLY PIPING DOWN WALL TO
<br />FIXTURE AND BACK UP WALL TO NEXT FIXTURE IN
<br />SERIES. HOT WATER SUPPLY TAP TO FIXTURE MUST BE
<br />WITHIN 6" OF FIXTURE CONNECTION.
<br />WATER
<br />RETURN
<br />POOL PAVILLION PLUMBING FIXTURE SCHEDULE
<br />MARK
<br />FIXTURE
<br />WASTE
<br />TRAP
<br />VENT
<br />COLD
<br />WATER
<br />HOT
<br />WATER
<br />MANUFACTURER
<br />/MODEL #
<br />DESCRIPTION
<br />WC-1
<br />WATER CLOSET - ADA
<br />3"
<br />INTEG
<br />-
<br />1/2"
<br />-
<br />AMERICAN STANDARD
<br />FLOOR MOUNTED TANK TYPE, 16-1/2" RIM HEIGHT, 1.28 GALLONS PER FLUSH, WHITE
<br />TANK TYPE
<br />CADET PRO
<br />VITREOUS CHINA, ELONGATED BOWL, BRASSCRAFT j TURN ANGLE STOP SUPPLY TUBE &
<br />LEFT HAND LEVER:
<br />ESCUTCHEONS. PROVIDE SOLID PLASTIC ELONGATED SEAT LESS COVER.
<br />215AA.104
<br />BOWL: 3517A.101
<br />TANK: 4188A.104
<br />RIGHT HAND LEVER:
<br />215AA.105
<br />BOWL: 3517A.101
<br />TANK: 4188A.105
<br />AMERICAN STANDARD
<br />5901.100
<br />UR-1
<br />URINAL - ADA
<br />3"
<br />INTEG
<br />-
<br />3/4"
<br />-
<br />AMERICAN STANDARD
<br />WALL HUNG FLUSH VALVE, 17" RIM HEIGHT, 0.125 GALLONS PER FLUSH, WHITE VITREOUS
<br />FLUSH VALVE
<br />WASHBROOK
<br />CHINA, WASHOUT FLUSH ACTION. MANUAL FLUSH VALVE.
<br />6590.503
<br />L-1
<br />LAVATORY - ADA
<br />2"
<br />1-1/4"
<br />1-1/2"
<br />1/2"
<br />1/2"
<br />STERLING SANIBEL
<br />20"x17" OVAL DROP -IN, VITREOUS CHINA, 4" CENTERS WITH FRONT OVERFLOW. TWO
<br />442004
<br />HANDLE LAVATORY FAUCET, 1.2 GPM, POP UP WASTE, P-TAND WALL ARM.
<br />BRASSCRAFT j TURN ANGLE STOP SUPPLIES W/SUPPLY TUBES AND ESCUTCHEONS.
<br />MOEN ADLER
<br />PROVIDE ANTI SCALD PIPING COVERS. TRUEBRO OR EQUAL.
<br />84603
<br />S-1
<br />SINK (SINGLE BOWL)
<br />2"
<br />1-1/2"
<br />1-1/2"
<br />1/2"
<br />1/2"
<br />AMERICAN STANDARD
<br />17"07" SINGLE BOWL, 18 GAUGE STAINLESS STEEL, TOP MOUNT SINK.
<br />PEKOE
<br />SINGLE LEVER HANDLE PULL DOWN SPRAYER, 1.5 GPM, STAINLESS STEEL FINISH.
<br />18SB.8171700.075
<br />STAINLESS STEEL STRAINER DRAIN AND TAILPIECE, P-TRAP AND WALL ARM.
<br />BRASSCRAFT j TURN ANGLE STOP SUPPLY TUBES & ESCUTCHEONS.
<br />MOEN ADLER
<br />87233
<br />EWC-1
<br />ELECTRIC WATER COOLER
<br />2"
<br />1-1/2"
<br />1-1/2"
<br />1/2"
<br />-
<br />ELKAY
<br />WALL MOUNTED ADA BI-LEVEL NON -FILTERED REFRIGERATED STAINLESS WATER COOLER.
<br />HIGH/LOW - OUTDOOR
<br />VRCGRNTL8C
<br />CHILLING CAPACITY OF 8.0 GPH WITH MECHANICAL FRONT BUBBLER PUSHBAR ACTIVATION.
<br />NO BOTTLE FILLER
<br />120V, 5 FLA POWER REQUIRED.
<br />NOTES:
<br />1. CONTRACTOR TO VERIFY IF THIS PROJECT HAS I.D. DRAWINGS. IF THERE ARE I.D. DRAWINGS THE PLUMBING FIXTURES SELECTED IN THE I.D. PACKAGE OVERRIDE THIS PLUMBING SCHEDULE.
<br />2. COLOR/FINISH OPTIONS SHALL BE SUBMITTED TO THE ARCHITECT/I.D./OWNER PRIOR TO PURCHASE AND INSTALLATION.
<br />3. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS OF ALL FIXTURES.
<br />4. ALL PLUMBING FIXTURES SHALL BE SUPPLIED WITH ANGLE STOP SUPPLY RISERS. THIS SHALL INCLUDE ALL FAUCETS AND TOILETS.
<br />GENERAL NOTES:
<br />1. ALL PLUMBING FIXTURES MUST BE REVIEWED AND APPROVED BY THE ARCHITECT/I.D. AND
<br />OWNER PRIOR TO ORDERING.
<br />2. CONTRACTOR TO VERIFY BATHTUB AND SHOWER SIZES, INCLUDING DRAIN LOCATION, WITH
<br />ARCHITECT PRIOR TO ORDERING.
<br />3. CONTRACTOR TO VERIFY LAVATORY AND SINK SIZES ARE COORDINATED WITH COUNTERTOPS
<br />BEING INSTALLED PRIOR TO ORDERING.
<br />4. CONTRACTOR TO VERIFY ALL PLUMBING EQUIPMENT SELECTED WITH ACCESSORIES FITS
<br />WITHIN DESIGNATED SPACE SHOWN ON PLUMBING PLANS AND PROVIDES THE CORRECT
<br />CLEARANCES REQUIRED BY THE MANUFACTURER.
<br />5. CONTRACTOR SHALL COORDINATE VOLTAGE, PHASE AND REQUIRED MOCP FOR EACH PIECE
<br />OF EQUIPMENT WITH THE ELECTRICAL CONTRACTOR PRIOR TO ORDERING.
<br />6. IF PRODUCTS/EQUIPMENT ARE VALUE ENGINEERED OR SUBSTITUTED IT IS THE
<br />CONTRACTORS RESPONSIBILITY TO FIELD COORDINATE ALL NEW PRODUCTS/EQUIPMENT
<br />REQUIREMENTS WITH OTHER DISCIPLINES/TRADES.
<br />i[ 1ILlI11I1I
<br />BALL VAL
<br />THERMAL EXPANSION TANK--•
<br />SIZE PER MFG'S
<br />CONTINUATION OF HOT n_,__�— COLD WATER SUPPLY RECOMMENDATION.
<br />WATER SOURCE
<br />UNION (TYPICAL) i
<br />HEAT TRAP (TYPICAL) - �I
<br />COLD WATER IN WALL
<br />14� 24 GAUGE GALVANIZED
<br />SHEETMETAL OR 60 MIL. HIGH
<br />IMPACT PLASTIC DRAINPAN7\
<br />4" HOUSEKEEPING PAD
<br />TWO-WAY VALVE FINISHED FLOOR--�,
<br />HOT WATER RECIRCULATING
<br />3 PUMP DETAIL 2 ENERGY EFFICIENCY CODE 1
<br />ns')(C404-5. 1)
<br />CW
<br />4
<br />NTS
<br />WHEEL HANDLE,
<br />LOOSE KEY IF
<br />SPECIFIED.
<br />"NIDEL" VACUUM
<br />BREAKER
<br />1p r MALE HOSE
<br />THREADS
<br />BRASS BODY
<br />9 _ 1�
<br />THREADS
<br />r CW
<br />r`AgT BRASS BODY
<br />IME PLATED)
<br />0
<br />0 0
<br />O tWITH
<br />Q OPERATOR
<br />E WRENCH
<br />"NIDEL" VACUUM
<br />BREAKER
<br />filk-2
<br />PROVIDE GATE VALVE SHUTOFF ABOVE CEILING
<br />(PROVIDE ACCESS PANEL IN HARD CEILING LOCATIONS)
<br />WALL MOUNTED HOSE BIB
<br />RECIRC. PUMP SEE DETAIL
<br />AND SCHEDULE.
<br />VALVE
<br />HWR
<br />T & COLD WATER PIPING IN CEILING
<br />ACE OR AS SHOWN ON DRAWINGS
<br />UT OFF VALVE
<br />TEMPERATURE AND PRESSURE
<br />RELIEF VALVE AS REQUIRED
<br />BY LOCAL CODE
<br />WATER HEATER (EWH) SEE
<br />SCHEDULE
<br />PIPE FULL SIZE OF T&P
<br />RELItF VALVE
<br />DRAIN VALVE
<br />ROUTE WATER HEATER PAN DRAIN TO
<br />EXTERIOR.
<br />ELECTRIC WATER HEATER DETAIL
<br />Joseph. Lawrence & Co
<br />Consultinq Engineers
<br />1180 HARWOOD AVE., SUITE 3000
<br />ALTAMONTE SPRINGS, FLORIDA 32714
<br />TEL: 321.972.4466
<br />WWW.JLCENG.COM
<br />CA NO. 28730
<br />ARCHITECTURE &
<br />INTERIOR DESIGN, INC.
<br />237 S. Westmonte Drive, Suite 220
<br />Altamonte Springs, FL 32714
<br />407.830.1400
<br />AA0002731
<br />www.forumarchitecture.com
<br />Zephyr
<br />Commons
<br />Apartments
<br />City of Zephyrhills, FL
<br />JLC21.0058.00
<br />Adam Joseph Barney
<br />P.E. #: 69124
<br />SET DISTRIBUTIONS:
<br />Q SHEET REVISIONS:
<br />EDITED BY: SMB/AJB
<br />PROJECT NO. 4097
<br />Pool Pavilion
<br />Schedules and Details
<br />Plumbing
<br />P19E41A