6 COMcheck Software Version COMcheckWeb
<br />�(l Envelope Compliance Certificate
<br />Project Information
<br />Energy Code: 2020 Florida Building Code, Energy Conservation
<br />Project Title: Zephyrhills Apartments - Pool Pavillion
<br />Location: Zephyrhills, Florida
<br />Climate Zone: 2a
<br />Project Type: New Construction
<br />Construction Site: Owner/Agent:
<br />Zephyrhills, Florida 33542
<br />Additional Efficiency Package(s)
<br />Credits: 1.0 Required 1.0 Proposed
<br />Reduced Lighting Power, 1.0 credit
<br />Building Area Floor Area
<br />1-Office: Nonresidential 170
<br />Envelope Assemblies
<br />Assembly
<br />Roof: Attic Roof with Wood Joists, [Bldg. Use 1 - Office]
<br />Floor: Slab -On -Grade: Unheated, [Bldg. Use 1 - Office] (b)
<br />FAST
<br />Exterior Wall North: Wood -Framed, 16" o.c., [Bldg. Use 1 -
<br />Office]
<br />Door: Insulated Metal, Swinging, [Bldg. Use 1 - Office]
<br />SOUTH
<br />Exterior Wall South: Wood -Framed, 16" o.c., [Bldg. Use 1 -
<br />Office]
<br />WEST
<br />Exterior Wall East: Wood -Framed, 16" o.c., [Bldg. Use 1 -
<br />Office]
<br />Designer/Contractor:
<br />Adam Barney
<br />Joseph Lawrence & Co
<br />1180 Harwood Ave
<br />Altamonte Springs, Florida 32714
<br />Gross Area Cavity Cont.
<br />or R-Value R-Value
<br />Perimeter
<br />331 0.0 30.0
<br />54 --- ---
<br />Proposed Budget U-
<br />U-Factor Factor(.)
<br />0.032 0.027
<br />0.730 0.730
<br />136 0.0 7.0 0.094 0.064
<br />42 --- --- 0.090 0,610
<br />136 0.0 7.0 0.094 0.064
<br />80 0.0 7.0 0.094 0.064
<br />(a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
<br />(b) Slab -On -Grade proposed and budget U-factors shown in table are F-factors.
<br />b♦ M b i b P.'
<br />Envelope Compliance Statement
<br />Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,
<br />specifications, and other calculations submitted with this permit application. The proposed envelope systems have been
<br />designed to meet the 2020 Florida Building Code, Energy Conservation requirements in COMcheck Version COMcheckWeb and to
<br />comply with any applicable mandatory requirements listed in the Inspection Checklist.
<br />Project Title: Zephyrhills Apartments - Pool Pavillion
<br />Data filename:
<br />Report date: 02/15/22
<br />Page 1 of 16
<br />nCOMcheck Software Version COMcheckWeb
<br />8/1 Exterior Lighting Compliance Certificate
<br />Project Information
<br />Energy Code: 2020 Florida Building Code, Energy Conservation
<br />Project Title: Zephyrhills Apartments - Pool Pavillion
<br />Project Type: New Construction
<br />Exterior Lighting Zone 2 (Residential mixed use area (LZ2))
<br />Construction Site: Owner/Agent: Designer/Contractor:
<br />Zephyrhills, Florida 33542 Adam Barney
<br />Joseph Lawrence & Co
<br />1180 Harwood Ave
<br />Altamonte Springs, Florida 32714
<br />Allowed Exterior bighting Power
<br />A B C D E
<br />Area/Surface Category Quantity Allowed Tradable Allowed Watts
<br />Watts / Wattage (B X C)
<br />Entry canopy 140 ft2 0.25 Yes 35
<br />Total Tradable Watts (a) = 35
<br />Total Allowed Watts = 35
<br />Total Allowed Supplemental Watts (b) = 400
<br />(a) Wattage tradeoffs are only allowed between tradable areas/surfaces.
<br />(b) A supplemental allowance equal to 400 watts may be applied toward compliance of both non -tradable and tradable
<br />areas/surfaces.
<br />Proposed Exterior Lighting Power
<br />A B C D E
<br />Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
<br />Fixture Fixture Watt.
<br />Entry S'raupy (140 f0; Iradab e Wattacte
<br />PA: LED Other Fixture Unit 25W: 1 3 14 42
<br />Total Tradable Proposed Watts = 42
<br />Exterior Lighting Compliance
<br />Statement
<br />Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,
<br />specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been
<br />designed to meet the 2020 Florida Building Code, Energy Conservation requirements in COMcheck Version COMcheckWeb and to
<br />comply with any applicable mandatory requirements listed in the Inspection Checklist.
<br />Blake L. Suddeth, P.E. &Ste, 02/15/2022
<br />Name - Title Signature Date
<br />90
<br />Project Title: Zephyrhills Apartments - Pool Pavillion TATE- Report date: 02/15/22 Data filename: 4 of 16
<br />OR I�1- age
<br />NAI�
<br />Adam 1, Barr
<br />Name - Title
<br />Project Title:
<br />Data filename:
<br />P.E. = - 02/15/2022
<br />Signature - Date
<br />(
<br />\111W II IiIf
<br />0\\�\�\\\\\\IIJU/I/jiii/�/
<br />9124
<br />Zephyrhills Apartments - Pool Pavillion
<br />TE
<br />86COMcheck Software Version COMcheckWeb
<br />/1 Mechanical Compliance Certificate
<br />Project Information
<br />Energy Code: 2020 Florida Building Code, Energy Conservation
<br />Project Title: Zephyrhills Apartments - Pool Pavillion
<br />Location: Zephyrhills, Florida
<br />Climate Zone: 2a
<br />Project Type: New Construction
<br />Report date: 02/15/22
<br />Page 2 of 16
<br />Construction Site: Owner/Agent: Designer/Contractor:
<br />Zephyrhills, Florida 33542 Adam Barney
<br />Joseph Lawrence & Co
<br />Additional Efficiency Package(s) 1180 Harwood Ave
<br />Altamonte Springs, Florida 32714
<br />Credits: 1.0 Required 1.0 Proposed
<br />Reduced Lighting Power, 1.0 credit
<br />Mechanical Systems List
<br />Quantity System Type & Description
<br />1 HVAC System 1 (Single Zone):
<br />Cooling: 1 each - Split System, Capacity = 9 kBtu/h, Air -Cooled Condenser, No Economizer, Economizer exception:
<br />None
<br />Proposed Efficiency = 18.00 SEER, Required Efficiency: 14.00 SEER
<br />Fan System: FAN SYSTEM 1 -- Compliance (Motor nameplate HP and fan efficiency method) : Passes
<br />Fans:
<br />FAN 1 Supply, Constant Volume, 320 CFM, 0.1 motor nameplate hp, 0.00 fan energy index , fan exception: Single
<br />fan < 1 HP or < 0.89 kW
<br />Mechanical Compliance Statement
<br />Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans,
<br />specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been
<br />designed to meet the 2020 Florida Building Code, Energy Conservation requirements in COMcheck Version COMcheckWeb and to
<br />comply with any applicable mandatory requirements listed in the Inspection Checklist.
<br />Adam J. Barney, P.E.7/1
<br />02/1$/2022
<br />Name - Title Signature Vr^"" Date
<br />i
<br />Project Title: Zephyrhills Apartments - Pool Pavillion
<br />Data filename:
<br />4- ,
<br />9124
<br />I+
<br />Report date: 02/15/22
<br />Page 5 of 16
<br />86COMcheck Software Version COMcheckWeb
<br />/1 Interior Lighting Compliance Certificate
<br />Project Information
<br />Energy Code: 2020 Florida Building Code, Energy Conservation
<br />Project Title: Zephyrhills Apartments - Pool Pavillion
<br />Project Type: New Construction
<br />Construction Site: Owner/Agent: Designer/Contractor:
<br />Zephyrhills, Florida 33542 Adam Barney
<br />Joseph Lawrence & Co
<br />Additional Efficiency Package(s) 1180 Harwood Ave
<br />Altamonte Springs, Florida 32714
<br />Credits: 1.0 Required 1.0 Proposed
<br />Reduced Lighting Power, 1.0 credit
<br />Allowed Interior Lighting Power
<br />A B C D
<br />Area Category Floor Area Allowed Allowed Watts
<br />(ft2) Watts / ft2
<br />1-Office 170 0.71 121
<br />Total Allowed Watts = 121
<br />Proposed Interior Lighting Power
<br />A B C D E
<br />Fixture ID : Description I Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
<br />Fixture Fixture Watt.
<br />I - Office
<br />PA: LED Other Fixture Unit 16W: 1 2 14 28
<br />PB: LED Other Fixture Unit 16W: 1 2 15 30
<br />Total Proposed Watts = 58
<br />JM
<br />Interior Lighting Compliance
<br />Statement
<br />Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans,
<br />specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been
<br />designed to meet the 2020 Florida Building Code, Energy Conservation requirements in COMcheck Version COMcheckWeb and to
<br />comply with any applicable mandatory requirements listed in the Inspection Checklist.
<br />Blake L. Suddeth, P.E. eg�' '/'-- � 02/15/2022
<br />Name - Title Signature Date
<br />\\\\\\11111111111J111 //�////
<br />i
<br />_ 9
<br />y or
<br />OR IMP
<br />Project Title: Zephyrhills Apartments Pool Pavillion/// /©NAL \�� Re ort date: 02/15/22
<br />Data filename: ///JJ/11111111N11\r\\\\\\� p Page 3 of 16
<br />Joseph, LAWrence & co
<br />ConsuItinq Incjineers
<br />1180 HARWOOD AVE., SUITE: 3000
<br />ALTAMONTE SPRINGS, FLORIDA 32714
<br />TEL: 321.972.4466
<br />WWW.JLCENG,COM
<br />CA NO. 28730
<br />3FORUMM
<br />m
<br />m
<br />ARCHITECTURE &
<br />INTERIOR DESIGN, INC.
<br />c
<br />L
<br />237 S. Westmonte Drive, Suite 220
<br />Altamonte Springs, FL 32714
<br />407.830.1400
<br />AA0002731
<br />www.forumarchitecture.com
<br />Zephyr
<br />Commons
<br />Apartments
<br />City of Zephyrhills, FL
<br />JLC21.0058.00
<br />Adam Joseph Barney
<br />P.E. #: 69124
<br />SET DISTRIBUTIONS:
<br />A SHEET REVISIONS:
<br />a EDITED BY: SMB/AJB
<br />ar
<br />PROJECT N0. 4097
<br />Pool Pavilion
<br />Energy Calculations
<br />Mechanical
<br />M 19.42A
<br />
|