N <br />N <br />t7 <br />N <br />O <br />y <br />GENERAL DRAWING NOTES: <br />• DO NOT SCALE DRAWINGS, USE DIMENSIONS PROVIDED, TYPICALLY. IN THE CASE OF DIMENSIONAL CONFLICT, <br />ARCHITECTURAL DIMENSIONS GOVERN OVER STRUCTURAL DIMENSIONS, TYPICALLY. <br />• CONTRACTOR SHALL COORDINATE THE STRUCTURAL DOCUMENTS w/ THE ARCHITECTURAL, MECHANICAL, <br />ELECTRICAL, PLUMBING, & CIVIL DOCUMENTS. SC&D SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCY OR <br />OMISSION. <br />+ THE STRUCTURE IS STABLE ONLY IN IT'S COMPLETED FORM. TEMPORARY SUPPORTS REQUIRED FOR STABILITY <br />DURING ALL INTERMEDIATE STAGES OF CONSTRUCTION SHALL BE DESIGNED, FURNISHED, & INSTALLED BY THE <br />CONTRACTOR, TYPICALLY. <br />• STRUCTURAL DRAWINGS ARE NOT TO BE REPRODUCED WITHOUT WRITTEN CONSENT FROM STRUCTURAL <br />CONCEPTS & DESIGN, LLC ANY REPRODUCTION OF THESE CONTRACT DOCUMENTS WITHOUT WRITTEN <br />CONSENT OF STRUCTURAL CONCEPTS & DESIGN, LLC. WILL BE REJECTED & NOT REVIEWED. <br />• SHOP DRAWING REVIEW SHALL REQUIRE TWO (2) WEEKS FOR COMPLETION FROM TIME OF DELIVERY TO <br />STRUCTURAL CONCEPTS & DESIGN, LLC. SHOP DRAWINGS SHALL BE CHECKED & "APPROVED" BY GENERAL <br />CONTRACTOR PRIOR TO SUBMITTAL TO ARCHITECT. <br />• CONTRACTORS SUBMITTING SHOP DRAWINGS TO PROVIDE THREE (3) BLACKLINE COPIES FOR MARK-UP. <br />ADDITIONAL COPIES WILL BE RETURNED WITHOUT MARKS OR APPROVAL STAMP. <br />THE GENERAL CONTRACTOR SHALL PREPARE A DETAILED LIST & SCHEDULE OF ALL SUBMITTAL ITEMS TO BE SENT TO <br />THE STRUCTURAL ENGINEER PRIOR TO THE START OF CONSTRUCTION. THIS LIST SHALL BE UPDATED, REVISED, & <br />KEPT CURRENT AS THE JOB PROGRESSES. <br />THE GENERAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE STRUCTURAL ENGINEER FOR REVIEW & <br />APPROVAL THE FOLLOWING ITEMS: <br />• CONCRETE MIX DESIGNS <br />• CONSTRUCTION JOINT LOCATIONS IN CONCRETE SLAB -ON -GRADE <br />• POST -TENSION FOUNDATIONS* <br />• MISCELLANEOUS STEEL <br />• REINFORCING STEEL: FOUNDATIONS, MASONRY, & CONCRETE <br />• STEEL/ALUMINUM HANDRAILS* <br />• ALUMINUM SCREEN ENCLOSURES* <br />• ENGINEERED WOOD ROOF TRUSS SYSTEMS* <br />y° SHOP DRAWING SUBMITTALS NOTED WITH AN "*" ARE REQUIRED TO BE SIGNED & SEALED BY A REGISTERED <br />PROFESSIONAL ENGINEER IN THE STATE WHERE THE PROJECT IS LOCATED. <br />THE GENERAL CONTRACTOR SHALL SUBMIT DESIGN CALCULATIONS PREPARED AND SIGNED & SEALED BY A <br />PROFESSIONAL ENGINEER IN THE STATE WHERE THE PROJECT IS LOCATED TO THE STRUCTURAL ENGINEER FOR <br />REVIEW & APPROVAL FOR THE FOLLOWING ITEMS: <br />• POST -TENSION FOUNDATIONS* <br />• STEEL/ALUMINUM HANDRAILS* <br />• ALUMINUM SCREEN ENCLOSURES* <br />• ENGINEERED WOOD ROOF TRUSS SYSTEMS* <br />DELEGATED ENGINEERING CALCULATION REQUIREMENTS: <br />• ALL SUBMITTED CALCULATIONS SHALL BE PRESENTED IN A LEGIBLE MANNER & FOLLOW AN ORDERLY, LOGICAL <br />SEQUENCE. <br />• ALL REFERENCES & SOURCES OF INFORMATION SHALL BE LISTED WITHIN THE CALCULATIONS. COPIES OF <br />PERTINENT SECTIONS SHALL BE INCLUDED. <br />• BASIC LOADS & DERIVATION OF FORCES, MOMENTS, SHEARS, REACTIONS, DEFLECTIONS, CAMBERS, ETC. SHALL BE <br />INCLUDED IN THE CALCULATIONS. INCLUDE ALL UNBALANCED LOADING FORCES AS REQUIRED. LOAD <br />REQUIREMENTS w/ APPROPRIATE FACTORS SHALL BE AS REQUIRED BY THE LATEST EDITION OF THE REFERENCED <br />BUILDING CODE. <br />• DESIGN ASSUMPTIONS SHALL BE CLEARLY STATED. <br />• ALL COMPUTER GENERATED CALCULATIONS SHALL BE ACCOMPANIED w/ EXPLANATIONS OF INPUT/OUTPUT <br />DATA (i.e. VARIABLE IDENTIFICATION, LOAD DERIVATION, ETC.) & A BRIEF EXPLANATION OF GENERAL THEORY, <br />METHOD, & DESIGN ASSUMPTIONS USED SHALL BE INCLUDED, <br />• ALL CALCULATIONS SHALL BE SIGNED & SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE <br />THE PROJECT IS LOCATED. DELEGATED ENGINEERING SUBMITTALS THAT DO NOT INCLUDE COMPLETE SIGNED & <br />SEALED CALCULATIONS IN COMPLIANCE w/ REQUIREMENTS NOTED ABOVE WILL BE REJECTED WITHOUT REVIEW. <br />• DELEGATED ENGINEERING CALCULATION SUBMITTALS THAT DO NOT MEET THESE REQUIREMENTS WILL BE <br />REJECTED WITHOUT REVIEW. <br />DUE TO MULTIPLE ISSUES w/ DELEGATED ENGINEERS NOT PROVIDING THE REQUIRED SUBMITTAL DOCUMENTS <br />AND/OR CALCULATIONS ON RECENT PROJECTS, THE CONTRACTOR MUST PROVIDE THE NAME OF EACH PROPOSED <br />DELEGATED ENGINEER (FOR EACH DELEGATED ENGINEERING SCOPE OF WORK) TO SC&D FOR REVIEW & APPROVAL <br />PRIOR TO THE CONTRACTOR SUBMITTING ANY DELEGATED ENGINEERING DOCUMENTS TO THE DESIGN TEAM. ANY <br />DELEGATED ENGINEERING SUBMITTALS FROM NON -APPROVED DELEGATED ENGINEERS WILL BE REJECTED WITHOUT <br />REVIEW. <br />• NOTE THAT ALL DELEGATED ENGINEERING SUBMITTALS MUST BE REVIEWED &APPROVED BY THE ARCHITECT & <br />ENGINEER OR RECORD PRIOR TO SUBMISSION TO THE BUILDING DIVISION, TYPICALLY. <br />00200 BUILDING CODES: <br />• FLORIDA BUILDING CODE 7th EDITION (2020) <br />• ASCE/SEI 7-16: MINIMUM DESIGN LOADS FOR BUILDINGS & OTHER STRUCTURES <br />00500 STRUCTURAL DESIGN CRITERIA: <br />THE STRUCTURE HAS BEEN DESIGNED IN ACCORD WITH METHOD 1 - ALLOWABLE STRESS DESIGN AS REQUIRED BY <br />SECTION 2802.1 OF THE FLORIDA BUILDING CODE. REQUIREMENTS FOR TYPICAL STRUCTURAL LOADS ARE GIVEN <br />BELOW UNLESS SPECIFIC AREAS OF THE DRAWING SPECIFICALLY CALL FOR DIFFERENT LOADING CRITERIA. <br />GRAVITY LOADING IS TO BE UNIFORM (U.N.O.) <br />LIVE LOADING PER FLORIDA BUILDING CODE <br />• SLAB -ON -GRADE AREAS: 150 PSF <br />• ROOFS (SLOPED): 20 PSF (REDUCIBLE) <br />WIND LOADING PER FLORIDA BUILDING CODE <br />• ULTIMATE DESIGN WIND SPEED: VuLT = 139 MPH (3 SECOND GUST) <br />• NOMINAL DESIGN WIND SPEED: VASD = 108 MPH (3 SECOND GUST) <br />• RISK CATEGORY = "II" <br />• EXPOSURE CATEGORY = "C" <br />• INTERNAL PRESSURE COEFFICIENTS = n/a (OPEN STRUCTURE) <br />• COMPONENT & CLADDING WIND PRESSURES SHOWN ON SHEET "S19.35" <br />THIS PROJECT IS NOT LOCATED WITHIN A WIND BORNE DEBRIS REGION. <br />EARTHQUAKE DESIGN DATA PER FLORIDA BUILDING CODE & ASCE/SEI 7 <br />• SEISMIC IMPORTANCE FACTOR: (1) = 1.0 <br />• SPECTRAL RESPONSE ACCELERATIONS: Ss = 0.058g Si = 0.032g <br />• SITE CLASS = "D" <br />• SPECTRAL RESPONSE COEFFICIENTS: SDs = 0.062g SDI = 0.051g <br />• SEISMIC DESIGN CATEGORY = "A" <br />• BASIC SEISMIC FORCE RESISTING SYSTEM: MASONRY SHEAR WALLS <br />• DESIGN BASE SHEAR = 3.5 KIPS (MAX.) FOR EACH AMENITY BUILDING <br />• RESPONSE MODIFICATION FACTOR (R) = 2 <br />• ANALYSIS PROCEDURE USED = EQUIVALENT LATERAL FORCE PROCEDURE <br />ESTIMATED DEFLECTIONS (IN INCHES) ARE AS FOLLOWS: <br />LIVE LOAD TOTAL LOAD <br />ROOF MEMBERS: L1360 or V L/240 <br />FLOOR MEMBERS: L/360 L1240 <br />WHERE "L" = SPAN LENGTH (IN.) BETWEEN CENTERLINES OF SUPPORTS. <br />General Structural Notes <br />01100 SCOPE OF SERVICE: <br />STRUCTURAL CONCEPTS & DESIGN, LLC AS THE STRUCTURAL ENGINEER OF RECORD HAS DESIGNED AND IS <br />RESPONSIBLE FOR ONLY THE SPECIFIC STRUCTURAL COMPONENTS SHOWN IN THIS SET OF STRUCTURAL <br />CONSTRUCTION DOCUMENTS. IF A SPECIALTY ENGINEER, AS DEFINED BY THE DEPARTMENT OF PROFESSIONAL <br />REGULATION, IS REQUIRED, HIS SERVICES MUST COMPLY WITH THE SCOPE OF SERVICES AS OUTLINED IN THE <br />PROJECT CONSTRUCTION DOCUMENTS. <br />01400 SCOPE OF SERVICE - THRESHOLD INSPECTOR: <br />THE THRESHOLD SPECIALTY INSPECTOR IS RESPONSIBLE FOR THE INSPECTION AND APPROVAL OF THE STRUCTURAL <br />COMPONENTS SHOWN IN THIS SET OF STRUCTURAL CONSTRUCTION DOCUMENTS AND AS INDICATED IN THE <br />THRESHOLD INSPECTION PLAN. THE THRESHOLD SPECIALTY INSPECTOR IS TO BE CONTRACTED BY THE OWNER AND <br />MUST BE A REGISTERED SPECIAL INSPECTOR IN THE STATE OF FLORIDA, IN COMPLIANCE WITH THE CURRENT EDITION <br />OF THE FLORIDA BUILDING CODE. <br />02000 FOUNDATIONS: <br />GEOTECHNICAL DATA AND RECOMMENDATIONS HAVE BEEN PROVIDED BY VERONICA DE FREITAS, P.E. & JAMES <br />STEPHENSON, P.E. (FL #86378) OF UNIVERSAL ENGINEERING SCIENCES, INC., 9802 PALM RIVER RD., TAMPA, FL 33619, <br />PHONE: (813) 704-8506, UES PROJECT No. 0830.2100171, UES REPORT No. 1927445 DATED JANUARY 17, 2022. BASED <br />ON THEIR RECOMMENDATIONS, THE FOLLOWING FOUNDATION SYSTEM WILL BE USED: <br />• SHALLOW STRIP & SPREAD FOOTINGS w/ MAXIMUM ALLOWABLE NET SOIL BEARING PRESSURE = 2,500 PSF <br />THE GEOTECHNICAL ENGINEER IS RESPONSIBLE FOR SPECIFYING AND MONITORING ALL TESTING, INSTALLATION, <br />EVALUATION, AND REPORTING RELATED TO THE FOUNDATION SYSTEM, INCLUDING ALL WORKMANSHIP <br />PROVISIONS RELATING TO THE SOIL - STRUCTURE INTERFACE. THE STRUCTURAL ENGINEER IS RESPONSIBLE FOR <br />SPECIFYING THE MATERIALS USED TO CONSTRUCT THE FOUNDATION UNITS AND FOR THE SELECTION OF VARIOUS <br />SIZE UNITS TO SUPPORT THE STRUCTURAL FRAME. <br />DO NOT PLACE ANY FOOTINGS OR MATS UNTIL RECEIPT OF WRITTEN AUTHORIZATION BY THE GEOTECHNICAL <br />ENGINEER THAT THE PREPARED SUBGRADE OR DEEP FOUNDATION SYSTEM HAS BEEN PROPERLY EXECUTED IN <br />ACCORD WITH THE DESIGN AND THAT ANY VARYING CONDITIONS ENCOUNTERED DURING CONSTRUCTION HAVE <br />BEEN EVALUATED AND CORRECTED WHERE NECESSARY TO INSURE PROPER FOUNDATION PERFORMANCE. <br />02200 EARTHWORK: <br />CONTRACTOR SHALL DEWATER SITE AS NECESSARY, SO THAT ALL CONCRETE CAN BE PLACED IN THE DRY. ALL <br />BACKFILL SHALL BE ACCOMPLISHED USING MATERIAL CONSISTING OF CRUSHED STONE AND/OR MATERIAL <br />APPROVED BY THE GEOTECHNICAL ENGINEER. THE BACKFILL SHALL BE COMPACTED TO 95% OF MAXIMUM DENSITY <br />AS DETERMINED BY ASTM D-1557. NO BACKFILL MATERIAL SHALL BE PLACED AGAINST WALLS WHICH DO NOT HAVE <br />PERMANENT FLOORS AT THE TOP AND BOTTOM WITHOUT PROVISIONS FOR ADEQUATE TEMPORARY BRACING OF <br />THOSE WALLS. PROVIDE ADEQUATE EXCAVATION BRACING IN ACCORD WITH GEOTECHNICAL ENGINEER <br />RECOMMENDATIONS TO MAINTAIN EXISTING FOOTINGS, UTILITIES, AND OTHER IMPROVEMENTS IN A SAFE <br />CONDITION. <br />02210 STRUCTURAL FILL: <br />FOUNDATIONS PLACED ON COMPACTED STRUCTURAL FILL HAVE BEEN DESIGNED FOR A MAXIMUM ALLOWABLE NET <br />SOIL BEARING PRESSURE OF 2,500 PSF. FILL TO BE COMPACTED TO 95% OF MAXIMUM DENSITY AS DETERMINED BY <br />ASTM D-1557. PLACE FILL IN LAYERS OF 12" THICK MAXIMUM AND UNDER THE DIRECT SUPERVISION OF A <br />GEOTECHNICAL ENGINEER. FILL TO BE TESTED TO VERIFY COMPACTION. <br />02260 PROOF -ROLLING: <br />ISOLATED SPREAD COLUMN FOOTINGS SHALL NOT BE LESS THAN Y-0" WIDE IN EITHER DIRECTION & SHOULD BE <br />BASED 1'-6" MIN. BELOW THE FINISHED FLOOR OR FINAL EXTERIOR GRADES AT 2,500 PSF MAX. ALLOWABLE NET SOIL <br />BEARING PRESSURE. CONTINUOUS STRIP WALL FOOTINGS SHALL NOT BE LESS THAN 2'-0" WIDE & SHOULD BE BASED <br />1'-6" MIN. BELOW THE FINISHED FLOOR OR FINAL EXTERIOR GRADES AT 2,500 PSF MAX. ALLOWABLE NET SOIL <br />BEARING PRESSURE. MONOLITHIC GRADE BEAMS & THICKENED SLAB SECTIONS SHALL NOT BE LESS THAN 12" WIDE w/ <br />A 450 CHAMFER TO THE SLAB & SHOULD BE BASED P-0" MIN. BELOW THE FINISHED FLOOR ELEVATION & 1'-0" MIN. <br />BELOW THE FINAL EXTERIOR GRADES AT 2,500 PSF MAX. ALLOWABLE NET SOIL BEARING PRESSURE ON SOIL <br />IMPROVED BY PROOF -ROLLING NOT LESS THAN THREE COVERAGES. FOR FOOTING WIDTHS OR EMBEDMENTS LESS <br />THAN THOSE SPECIFIED, THE ALLOWABLE BEARING PRESSURES ARE REDUCED PROPORTIONALLY. PERFORM ALL <br />PROOF -ROLLING OPERATIONS IN ACCORD WITH THE RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER IN <br />THE PRESENCE OF THE OWNER'S AUTHORIZED AGENCY. <br />03100 FORMWORK: <br />CONTRACTOR SHALL DESIGN AND ERECT FORMWORK IN STRICT COMPLIANCE WITH ACI 347. SEE TYPICAL DETAILS <br />FOR CAMBER REQUIREMENTS. CONTRACTOR SHALL COORDINATE ALL OPENINGS AS REQUIRED FOR OTHER TRADES. <br />OPENINGS WHERE SHOWN ON THE STRUCTURAL DRAWINGS ARE TO IDENTIFY DESIGN INTENT ONLY. THE SPECIFIC <br />DIMENSIONS AND LOCATIONS SHALL BE FURNISHED OR CONFIRMED BY THE TRADE REQUIRING THE OPENING. <br />PROVIDE CHAMFERS AT ALL CORNERS IN CONCRETE MEMBERS EXPOSED TO VIEW. FORMWORK TO REMAIN IN PLACE <br />UNTIL CONCRETE HAS ATTAINED ENOUGH STRENGTH TO SUPPORT ALL DEAD LOADS PLUS A MINIMUM OF 50 PSF OF <br />ADDITIONAL CONSTRUCTION LOAD. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. <br />03200 CONCRETE REINFORCEMENT: <br />WORK SHALL BE IN ACCORD WITH THE CURRENT EDITIONS OF ACI 318, ACI 318R, ACI 315, ACI 318, CRSI "MANUAL OF <br />STANDARD PRACTICE", CRSI "PLACING REINFORCING BARS", WIRE REINFORCEMENT INSTITUTE "MANUAL OF <br />STANDARD PRACTICE -STRUCTURAL WELDED WIRE REINFORCEMENT'. BARS SHALL CONFORM TO ASTM <br />SPECIFICATION A615(SI), GRADE 60. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. CONCRETE COVER <br />REQUIRED AS FOLLOWS: <br />A. CAST AGAINST AND EXPOSED TO EARTH: 3" <br />B. FORMED, EXPOSED TO EARTH OR WEATHER: 2" (#6 & LARGER) <br />lI/" (#5 & SMALLER) <br />C. SLABS AND WALLS: <br />NO EARTH OR WEATHER EXPOSURE Y4" (#II & SMALLER) <br />3 HOUR FIRE RATING AND LESS Y4" <br />LAP SPLICE LENGTHS SHALL BE AS FOLLOWS: <br />1. ALL LAP SPLICES SHALL BE TENSION CLASS "B" UNLESS OTHER LAP CONDITIONS ARE SPECIFICALLY SHOWN ON THE <br />DRAWINGS. <br />2. SPLICE LENGTHS SHALL BE SHOWN ON SHOP DRAWINGS. <br />3. USE GENERAL HOOK BAR DEVELOPMENT LENGTHS UNLESS SPECIAL CONFINEMENT CONDITIONS ARE SATISFIED <br />IN ACCORD WITH ACI 318. <br />03300 CAST -IN -PLACE CONCRETE: <br />TO BE MIXED AND PLACED IN ACCORDANCE WITH THE CURRENT EDITION OF ACI 301. ALL REINFORCED CONCRETE <br />TO HAVE 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS: <br />ALL STRUCTURAL ELEMENTS F'c = 4,000 PSI UNLESS NOTED OTHERWISE. <br />• BEAMS & COLUMNS: F'c = 4,000 PSI <br />• FOUNDATIONS: F'c = 3,000 PSI <br />• SLABS ON GRADE: F'c = 3,000 PSI <br />• LIGHTWEIGHT TOPPING: F'c = 2,200 PSI (MIN.) <br />ALL CONCRETE MIX DESIGN SUBMITTALS SHALL INCLUDE A WRITTEN DESCRIPTION INDICATING WHERE EACH <br />PARTICULAR MIX IS TO BE PLACED WITHIN THE STRUCTURE. <br />03310 CONCRETE TESTING: <br />OWNER WILL EMPLOY AN INDEPENDENT TESTING LABORATORY TO PERFORM THE FOLLOWING TESTS AND SUBMIT <br />TEST REPORTS ON CAST IN PLACE CONCRETE: <br />• ASTM C143 "STANDARD TEST METHOD FOR SLUMP OF PORTLAND CEMENT CONCRETE." SLUMP SHALL NOT <br />EXCEED LIMIT INDICATED ON APPROVED MIX DESIGN, OR 6" (WHICHEVER IS SMALLER) <br />• ASTM C39 "STANDARD TEST METHOD FOR COMPRESSIVE STRENGTH OF CYLINDRICAL CONCRETE SPECIMENS." <br />CYLINDERS SHALL BE TAKEN FOR EACH MIX DESIGN USED, AND FOR EVERY 50 CUBIC YARDS OF CONCRETE <br />PLACED. TEST CYLINDERS AT THE FOLLOWING AGES: <br />1 CYLINDER AT 3 DAYS, I CYLINDER AT 7 DAYS, 2 CYLINDERS AT 28 DAYS <br />-or- <br />HOLD ONE RESERVE CYLINDER TO BE TESTED AS REQUESTED BY THE ENGINEER. IF REQUIRED <br />28 DAY STRENGTH IS ACHIEVED, THE RESERVE CYLINDER MAY BE DISCARDED. <br />03365 POST -TENSIONED CONCRETE FOR FOUNDATIONS: <br />CONCRETE STRENGTHS AT TRANSFER OF PRESTRESS FORCE TO CONCRETE SHALL BE AT 2,000 PSI (MIN.). THE <br />TENDONS SHALL BE TENSIONED AS SOON AS POSSIBLE AFTER THIS STRENGTH IS REACHED, BUT THE TENDON MUST <br />BE TENSIONED NO LATER THAT 7 DAYS AFTER CONCRETE PLACEMENT. ALL REQUIREMENTS AND <br />RECOMMENDATIONS IN ACI-318-02 AND ACI-ASCE COMMITTEE 423, SHALL APPLY TO THIS WORK. ALL FORCES ARE <br />SHOWN IN KIPS (1,000 LBS). C.G.S. - INDICATES CENTER GRAVITY OF TENDONS. C.G.C. - INDICATES CENTER GRAVITY <br />OF CONCRETE. THE CONSTRUCTION JOINT LOCATION SHALL BE LOCATED FROM THE CENTER LINE OF SUPPORT <br />WHERE THE CGS OF THE TENDONS INTERSECT THE C.G.C. OF THE CONCRETE. THOROUGHLY VIBRATE THE <br />CONCRETE BEHIND ALL TENDON ANCHOR PLATES. PROVIDE BACK-UP REBARS BEHIND ALL ANCHOR PLATES AT <br />CONCRETE EDGES AS DETAILED. SPACING OF TENDONS SHALL BE IN ACCORDANCE WITH ACI-ASCE COMMITTEE 423. <br />PROVIDE CONCRETE COVER ON REBARS AND TENDONS UNLESS DETAILED OTHERWISE. ADEQUATE SUPPORT BARS <br />AND CHAIRS SHALL BE PROVIDED TO DEFINE THE TENDON PROFILE AND TENDONS SHALL BE FIRMLY TIED IN PLACE <br />TO PREVENT DISPLACEMENT BY CONSTRUCTION LOADS AND PLACING OF CONCRETE. THE PLACEMENT <br />TOLERANCE OF TENDONS SHALL BE IN ACCORDANCE WITH ACI-ASCE 423. FASTENERS IN CONCRETE SLABS, <br />REQUIRED FOR OTHER TRADES SHALL BE CAST -IN -PLACE WHERE EVER FEASIBLE. DRILLED -IN FASTENERS MAY BE USED <br />ONLY WHERE TENDONS ARE LOCATED MAGNETICALLY OR BY OTHER MEANS PRIOR TO DRILLING. <br />POWDER -DRIVEN FASTENERS WITH PENETRATION OF Y8" LESS THAN REQUIRED COVER WILL BE PERMITTED. <br />CHLORIDE IN CONCRETE SHALL NOT BE PERMITTED. PROFILES AND FORCES BASED ON I/" DIAMETER STRANDS Q <br />WIRE). EFFECTIVE STRESS IN PRESTRESSING STEEL AFTER LOSSES IS ASSUMED TO BE 171 KSI WHICH SHALL BE VERIFIED <br />OR MODIFIED BY CALCULATIONS IN ACCORD WITH ACI-ASCE 423 RECOMMENDATION. YIELD STRENGTH OF <br />PRESTRESSING STEEL = 270 KSI. POST -TENSIONED FORCES SPECIFIED IN THE CONTRACT DRAWINGS ARE REQUIRED <br />EFFECTIVE FORCES AFTER APPROPRIATE LOSSES ARE ACCOUNTED FOR. CALCULATIONS SUBMITTED WITH THE <br />POST -TENSIONING MATERIAL SHOP DRAWINGS SHALL INDICATE THE VALUES FOR ALL LOSSES APPROPRIATE TO THIS <br />PROJECT FOR THE MATERIAL PROPOSED. CERTIFIED TEST DATA SUBSTANTIATING LOSS ASSUMPTIONS SHALL ALSO <br />BE SUBMITTED. NOTE THAT SUBMITTALS INDICATING EFFECTIVE FORCES DIFFERENT FROM THOSE SHOWN ON <br />THE CONTRACT DRAWINGS (SUPPLIER REDESIGN) WILL BE RETURNED, NOT REVIEWED, AS NOT RESPONSIVE TO <br />CONTRACT REQUIREMENTS. ALL STRUCTURAL SUBMITTALS (CALCULATIONS & SHOP DRAWINGS) BY THE <br />POST -TENSIONED SUBCONTRACTOR SHALL BE SIGNED AND SEALED BY THE SPECIALTY ENGINEER. <br />GROUTING IS CLASSIFIED AS "PRECISION GROUTING" FOR SUPPORT OF OPERATING MACHINE BASES, EQUIPMENT <br />SUBJECT TO THERMAL MOVEMENT, AND BASE PLATES, BEARING PLATES, AND EXPANSION BEARINGS EXCEEDING 8" <br />IN LEAST DIMENSION. ALL OTHER GROUTING MAY BE "ORDINARY GROUTING". METALLIC AGGREGATE GROUT MAY <br />BE USED ONLY IN INTERIOR APPLICATIONS NOT EXPOSED TO VIEW IN FINISHED BUILDING AREAS. USE ORDINARY <br />CEMENT GROUT ONLY WHERE SPECIFICALLY NOTED AS "CEMENT GROUT' ON DETAILS. USE NON -SHRINK GROUT <br />FOR ALL OTHER LOCATIONS. PRECISION GROUT SHALL CONFORM TO CRD-C621-80 WHEN MIXED TO FLUID <br />CONSISTENCY OF 22 TO 25 SECONDS (FLOW CONE METHOD, CRD-C611-80). REQUIRED 28 DAY STRENGTHS SHALL <br />BE AS FOLLOWS: <br />• CEMENT GROUT: 1,800 PSI <br />• NON -SHRINK GROUT: 5,000 PSI <br />• PRECISION GROUT: 6,500 P51 <br />04220 CONCRETE UNIT MASONRY: <br />ALL MASONRY CONSTRUCTION TO BE IN ACCORDANCE WITH "SPECIFICATION FOR CONCRETE MASONRY <br />CONSTRUCTION", ACI 530-08 & ACI 530.1-08 AND ALL APPLICABLE LOCAL BUILDING CODE PROVISIONS. ALL <br />MASONRY WALLS TO BE CONSTRUCTED ENTIRELY OF UNITS CONFORMING TO ASTM C 90, AND REINFORCED <br />WITH #9 GAUGE LADDER TYPE HORIZONTAL MASONRY REINFORCING LOCATED AT 16" O.C. ALL MASONRY TO BE <br />LAID IN TYPE "S" MORTAR (1,800 PSI ON THE JOB) WITH FULL HEAD AND BED JOINTS. ALL MASONRY <br />CONSTRUCTION TO BE EITHER BOUND BY TIE BEAM, TIE COLUMN MEMBERS OR TIED TO FRAME WITH 16 GAUGE <br />CONTINUOUS DOVETAIL SLOT AND 12 GAUGE DOVETAIL ANCHOR SPACED @ 16" O.C. (TOP AND TWO VERTICAL <br />SIDES). <br />04230 REINFORCED UNIT MASONRY: <br />ALL REINFORCED MASONRY CONSTRUCTION SHALL BE IN ACCORD WITH APPLICABLE PROVISIONS OF CONCRETE <br />REINFORCEMENT, CAST -IN -PLACE CONCRETE, AND CONCRETE MASONRY. VERTICAL REINFORCING SHALL ANCHOR <br />INTO SUPPORTING CONCRETE MEMBERS A CLASS "B" LAP LENGTH PLUS 3" OR FULL DEPTH PLUS A STANDARD <br />HOOK. LAPS WITHIN REINFORCED MASONRY SHALL BE 48 BAR DIAMETERS. CONTRACTOR SHALL COORDINATE <br />PLACING OF DOWELS TO ACCOMMODATE MODULE OF MASONRY UNITS. ALL VERTICAL CELLS AND BEAMS WITH <br />REINFORCING SHALL BE FILLED WITH COARSE GROUT CONSISTING OF 3,000 PSI CONCRETE WITH #8 COARSE <br />AGGREGATE. USE HIGH -SLUMP (SUPERPLASTICIZED) WHERE HEIGHT OF LIFT EXCEEDS 5-0". WHERE HEIGHT OF OPEN <br />CELL EXCEEDS 5-0% USE HIGH -LIFT GROUTING TECHNIQUE WHICH REQUIRES A CLEAN -OUT OPENING AT THE <br />BOTTOM OF ALL CELLS. ALL WALLS TO BE REINFORCED WITH #5 BARS SPACED AT 48" O.C. MAX. VERTICAL, TYP. <br />(U.N.O.) <br />05055 WELDING: <br />ALL WELDING TO BE IN ACCORDANCE WITH THE LATEST EDITION OF THE AMERICAN WELDING SOCIETY (AWS) D1.1 <br />- 2001 "STRUCTURAL WELDING CODE - STEEL" AND AS INDICATED ON THE STRUCTURAL DRAWINGS. WELDING <br />ELECTRODES SHALL BE E70XX, UNLESS NOTED OTHERWISE. WELDING ELECTRODES, WELDING PROCESS, MINIMUM <br />PREHEAT AND INTERPASS TEMPERATURES TO BE IN ACCORDANCE WITH THE A.W.S. SPECIFICATIONS. ANY <br />STRUCTURAL STEEL DAMAGED IN WELDING TO BE REPLACED OR ACCEPTABLY REINFORCED. ALL FULL PENETRATION <br />GROOVE WELDS TO BE SUBJECT TO RADIOGRAPHIC, MAGNETIC PARTICLE, ULTRASONIC, AND LIQUID PENETRANT <br />INSPECTION CONDUCTED BY AN INDEPENDENT TESTING AGENCY PAID FOR BY THE OWNER. <br />05521 ENGINEERED STEEL/ALUMINUM HANDRAILS: <br />STEEL OR ALUMINUM RAILING SYSTEM INCLUDING MEMBERS, COMPONENTS, & CONNECTIONS SHALL BE DESIGNED <br />BY A DELEGATED SPECIALTY ENGINEER & DETAILED BY THE SUPPLIER. SUBMIT COMPLETE SHOP DRAWINGS & <br />CALCULATIONS SIGNED & SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS <br />LOCATED. THE CONFIGURATION OF THE RAILING SYSTEM SHALL BE AS SHOWN ON THE ARCHITECTURAL <br />DRAWINGS. THE RAILING SYSTEM & ALL CONNECTIONS SHALL BE DESIGNED FOR APPLICABLE LOADS AS INDICATED <br />ON THE PLANS AND IN THE BUILDING CODES. ALL LOADS SHALL BE CLEARLY INDICATED ON THE CALCULATIONS & <br />SHOP DRAWINGS. SHOP DRAWINGS SHALL SHOW & SPECIFY ALL CONNECTIONS UTILIZED WITHIN THE RAILING <br />SYSTEM AS WELL AS CONNECTIONS TO & LOADS IMPOSED UPON THE STRUCTURAL FRAMING SYSTEM. <br />06110 STRUCTURAL WOOD FRAMING: <br />ALL DIMENSIONED LUMBER 2" & LESS IN NOMINAL THICKNESS SHALL BE SURFACED DRY & STAMPED BY AN AGENCY <br />CERTIFIED BY THE BOARD OF REVIEW OF THE AMERICAN LUMBER STANDARDS COMMITTEE & MANUFACTURED IN <br />ACCORD WITH PS 20-70. MEMBERS THICKER THAN 2" NOMINAL MAY BE SURFACED GREEN. MINIMUM SPECIES AND <br />GRADES FOR VISUALLY GRADED DIMENSION LUMBER SHALL BE AS FOLLOWS: <br />• SOUTHERN PINE KD No. 2 (2" to 4" THICK & 2" to 4" WIDE -REVISED VALUES AS OF JUNE], 2013): <br />Fb = 1,100 PSI, Ft = 675 PSI, Fv = 175 PSI, Fcp = 565 PSI, Fc = 1,450 PSI, E = 1,400,000 PSI <br />• SOUTHERN PINE KD No. 2 (2" to 4" THICK & 5" to 6" WIDE - REVISED VALUES AS OF JUNE 1, 2013): <br />Fb = 1,000 PSI, Ft = 600 PSI, Fv = 175 PSI, Fcp = 565 PSI, Fc = 1,400 PSI, E = 1,400,000 PSI <br />• SOUTHERN PINE KD No. 2 (2" to 4" THICK & 8" WIDE - REVISED VALUES AS OF JUNE 1, 2013): <br />Fb = 925 PSI, Ft = 550 PSI, Fv = 175 PSI, Fcp = 565 PSI, Fc = 1,350 PSI, E = 1,400,000 PSI <br />• SOUTHERN PINE KD No. 2 (2" to 4" THICK & 10" WIDE -REVISED VALUES AS OF JUNE 1, 2013): <br />Fb = 800 PSI, Ft = 475 PSI, Fv = 175 PSI, Fcp = 565 PSI, Fc = 1,300 PSI, E = 1,400,000 PSI <br />• SOUTHERN PINE KD No. 2 (2" to 4" THICK & 12" WIDE -REVISED VALUES AS OF JUNE 1, 2013): <br />Fb = 750 PSI, Ft = 450 PSI, Fv = 175 PSI, Fcp = 565 PSI, Fc = 1,250 PSI, E = 1,400,000 PSI <br />• SPRUCE -PINE -FIR KD No. 2 GRADE (SPECIFIC GRAVITY = 0.42): <br />Fb = 1,250 PSI, Ft = 725 PSI, Fv = 175 PSI, Fcp = 565 PSI, Fc = 1,600 PSI, E = 1,600,000 PSI <br />+ DOUGLAS FIR -LARCH KD No. 2 GRADE: <br />Fb = 1,250 PSI, Ft = 725 PSI, Fv = 175 PSI, Fcp = 565 PSI, Fc = 1,600 PSI, E = 1,600,000 PSI <br />ALL STUDS & HEADER SHOULDERS SHALL BE ONE PIECE BETWEEN PLATES AND/OR HEADERS. DO NOT USE BLOCKING <br />BETWEEN HEADERS AND SHOULDER WITH SOFTER COMPRESSION PERPENDICULAR (Fcp) THAN REQUIRED FOR <br />HEADER. DO NOT CUT LET -IN BRACING INTO STUDS. PROVIDE G90 GALVANIZED HURRICANE CLIPS IN ACCORD <br />WITH LOCAL CODE AT ALL ROOF ANCHORAGES & AT ALL FLOORS, TYPICALLY. <br />sty a Q/ J <br />4-1FORUME <br />+� m <br />z <br />06115 STRUCTURAL SHEATHING: .� N ARCHITECTURE & <br />PLYWOOD SHALL CONFORM TO PSI-83 & SHALL BE APA GRADE -STAMPED. ROOF SHEATHING SHALL BE "APA RATED 0z INTERIOR DESIGN, INC. <br />SHEATHING EXTERIOR EXPOSURE", Y2" or %" THICK PER PLAN WITH PLY CLIPS AT JOINTS BETWEEN JOISTS OR Ij, PLANNING I ARCHITECTURE I INTSWR DESIGN <br />TRUSSES, TYPICALLY (U.N.O.). FLOOR SHEATHING SHALL BE "APA RATED SHEATHING EXPOSURE 1", 2%2" (MIN.) W <br />THICK TONGUE & GROOVE, TYPICALLY (U.N.O.). WALL SHEATHING SHALL BE "APA RATED SHEATHING EXTERIOR r ° <br />EXPOSURE", 132" THICK, TYPICALLY (U.N.O.). CONFORM TO APA RECOMMENDATIONS FOR INSTALLATION OF 0 <br />237 S. Westmonte Drive, Suite 220 <br />PLYWOOD WALL SHEATHING. PROVIDE P.T. PLYWOOD @ FIRST 48 ABOVE SLAB ON GRADE, TYP. TREAT ALL .0 <br />FRAMING IN CONTACT WITH CONCRETE OR MASONRY IN ACCORD WITH AMERICAN WOOD PRESERVER'S ? Altamonte Springs, FL 32714 <br />BUREAU LP-2 OR PROVIDE %4" THICK 60 DUROMETER BEARING PAD BETWEEN CONCRETE OR MASONRY AND 3 407.830.1400 <br />W <br />UNTREATED WOOD MEMBER. vvww.forumarchitecture.com <br />ORIENTED STRAND BOARD (O.S.B.) SHALL BE APA GRADE -STAMPED. ROOF SHEATHING SHALL BE "APA RATED C <br />SHEATHING EXTERIOR EXPOSURE", %2' or %" THICK PER PLAN WITH PLY CLIPS AT JOINTS BETWEEN JOISTS OR <br />TRUSSES, TYPICALLY (U.N.O.). FLOOR SHEATHING SHALL BE "APA RATED STURD-I-FLOOR SHEATHING EXPOSURE 1", s- Q <br />2%2" (MIN.) THICK TONGUE & GROOVE, TYPICALLY (U.N.O.). WALL SHEATHING SHALL BE "APA RATED SHEATHING 0 0 <br />EXTERIOR EXPOSURE", %6" THICK, TYPICALLY (U.N.O.). CONFORM TO APA RECOMMENDATIONS FOR U U_ <br />INSTALLATION OF O.S.B. SHEATHING. TREAT ALL FRAMING IN CONTACT WITH CONCRETE OR MASONRY IN ro o <br />ACCORD WITH AMERICAN WOOD PRESERVER'S BUREAU LP-2 OR PROVIDE Y4" THICK 60 DUROMETER BEARING PAD C z Zephyr <br />BETWEEN CONCRETE OR MASONRY AND UNTREATED WOOD MEMBER. 0 <br />• EXTERIOR WALL SHEATHING: I% z Commons <br />7/6' PLYWOOD or O.S.B. SHEATHING FASTENED w/ 8d RING SHANK NAILS @ 6" O.C. @ PANEL EDGES & 0 <br />12" O.C. INFIELD, TYP. (U.N.O.) PROVIDE Y2" P.T. PLYWOOD @ FIRST 48" ABOVE SLAB ON GRADE. + <br />C ° <br />• ROOF SHEATHING: ro 0 <br />tu <br />Ys" PLYWOOD or O.S.B. SHEATHING w/ H-CLIPS AS REQ'D. FASTENED w/ 8d RING SHANK or 10d COMMON f6 x <br />NAILS @ 6" O.C. @ PANEL EDGES & 12" O.C. INFIELD, TYP. (U.N.O.) UU W <br />W <br />x <br />06190 ENGINEERED WOOD TRUSSES: <br />,N r <br />THIS IS A SYSTEM OF CUSTOM ENGINEERED COMPONENTS AND CONNECTIONS IN ACCORD WITH ALL APPLICABLE >. 3 <br />N <br />STANDARDS OF TRUSS PLATE INSTITUTE, INCLUDING BUT NOT LIMITED TO TPI-78 "DESIGN SPECIFICATION FOR .0 z <br />METAL PLATE CONNECTED WOOD TRUSSES" AND "INTERIM GUIDELINES", CSP-78 "RECOMMENDED CODE OF -0 <br />STANDARD PRACTICE," HET-80 "HANDLING AND ERECTING WOOD TRUSSES", BWT-76 "BRACING WOOD TRUSSES", 01 0 <br />QCM-77 "QUALITY CONTROL MANUAL" AND THE DEPARTMENT OF PROFESSIONAL REGULATIONS GUIDELINES. C W <br />THE ENTIRE SYSTEM INCLUDING ALL TRUSSES, CONNECTORS BETWEEN TRUSSES, BRIDGING, TEMPORARY BRACING E City of Zephyrhills, FL <br />FOR ERECTION, ANCHORAGE, AND EMBEDMENTS SHALL BE DESIGNED BY A SPECIALTY ENGINEER. THE REVIEW OF I. <br />ALL STRUCTURAL SUBMITTALS BY THE STRUCTURAL ENGINEER OF RECORD SHALL BE TO INSURE THAT HIS INTENT 0) o <br />HAS BEEN UNDERSTOOD AND THAT THE SPECIFIED CRITERIA HAVE BEEN USED. A COPY OF ALL STRUCTURAL Q) o ' <br />SUBMITTALS WILL BE RETAINED FOR RECORD KEEPING PURPOSES ONLY. TRUSS CALCULATIONS > 0 COMPONENT 'O <br />' <br />AA <br />DRAWINGS, CONNECTOR CALCULATIONS, AND ERECTION PLANS SHALL BE SIGNED AND SEALED BY TRUSS w+ F .... <br />ENGINEER AND SUBMITTED TO LOCAL BUILDING OFFICIAL FOR APPROVAL. DESIGN TRUSSES FOR LOADS SHOWN a ( -4ots <br />ON PLANS. IN THE ABSENCE OF LOADS, USE APPLICABLE LOCAL CODE FOR LIVE LOAD AND ACTUAL WEIGHT OF gg <br />v F <br />BUILDING MATERIALS FOR DEAD LOAD. USE PATTERNED AND PARTIAL SPAN LIVE LOADS WHERE REQUIRED TO '>;) o -- - <br />PRODUCE MAXIMUM FORCE IN ANY TRUSS MEMBER. APPLY NET WIND UPLIFT ON ROOFS WHEN APPLICABLE. z96s WEST STATE ROAD a3a, SUITE407/ Too LONGWOOD, 8 -2386 <br />Z TEL 407/682.2086 a FAX 407/682-2386 <br />TRUSS TOP CHORDS SHALL BE GROUP II SPECIES LUMBER. EXPOSED TO VIEW TRUSSES SHALL BE OF SELECT U ° WWW.SCD-ENG.COM <br />STRUCTURAL GRADE. ALL OTHER GRADE AND SPECIES SELECTION IS AT THE DISCRETION OF THE SUPPLIER.ui <br />COORDINATE ALL TRUSS DETAILS WITH ARCHITECTURAL DRAWINGS. FOR CONCEALED TO VIEW TRUSSES, WEB C ° <br />CONFIGURATIONS WHERE SHOWN ARE SUGGESTIONS AND MAY BE MODIFIED BY THE SUPPLIER FOR ECONOMY. <br />PROVIDE SIMPSON "TSS" PLATE, TAR IMPREGNATED FELT PAPER, OR OTHER SUITABLE VAPOR BARRIER BETWEEN _ � t <br />TRUSSES AND CONCRETE OR MASONRY BEARING SURFACES. PROVIDE G90 GALVANIZED HURRICANE ANCHORS a a <br />DESIGNED FOR NET WIND UPLIFT AT ALL BEARINGS. _' <br />.0 o U ar,.'b <br />G <br />W c n <br />06200 GLUE LAMINATED WOOD PRODUCTS: [U//��- <br />N <br />THIS IS A SYSTEM OF CUSTOM ENGINEERED WOOD COMPONENTS MANUFACTURED BY BOISE CASCADE, LLC WITH 3 <br />THE FOLLOWING CERTIFIED MINIMUM PROPERTIES: <br />° o��lioouo��° <br />• VERSA -LAM 1.7 2650 SP BEAMS W Robe C. Scroggins, P.E. <br />E = 1,700,000 PSI Fb = 2,650 PSI Fv = 285 PSI Ft = 1,650 PSI .fl FL Registration No. 56158 <br />Fe PARALLEL = 3,000 PSI Fe PERP. = 750 PSI ro z This document has been electronically signed and sealed by Robert C. Scroggins, PE on the Date <br />(PARALLEL) <br />( ) V 0 and/or Tlme Stamp shown using a digital signature. Printed copies of this document are not <br />tuconsidered signed and sealed and the signature must be verified on any electronic copies. <br />• VERSA -LAM 1.7 2650 SP COLUMNS & STUDS a o <br />E = 1,700,000 PSI, Fb = 2,650 PSI, Fv = 285 PSI, Ft = 1,650 PSI, II' i- <br />Fc (PARALLEL) = 3,000 PSI, Fc (PERP.) = 750 PSI o SET DISTRIBUTIONS: <br />.0 a 12/16/2021 OWNER REVIEW SET <br />SEE PLAN FOR BEAM SIZES. ALL WOOD BEAMS WITH THE PREFIX PL ARE TO BE CONSTRUCTED AS PARALLAM +4 ° --- - <br />BEAMS, TYP. (UNLESS NOTED OR DETAILED OTHERWISE) U 02/17/2022 PERMIT SET <br />W <br />t N __ <br />3 W <br />i, <br />0 <br />Ca - - - - <br />G } <br />_, <br />0 <br />U Z) <br />N <br />N <br />U W - <br />v <br />0 ° <br />z <br />a� <br />4.0 <br />z <br />L Z <br />W <br />L ° <br />0 ° r Z� SHEET REVISIONS: <br />kA i- <br />C z <br />0 co <br />;: W - <br />U U <br />x <br />U Q <br />- <br />a <br />0 <br />'D U_ - -- <br />C 0 <br />0 <br />ro r <br />Vt Wfl <br />- <br />C 0 <br />ro (k <br />G. <br />- -- --- <br />aW <br />z <br />C <br />z <br />z <br />V U <br />W <br />3 ° <br />z <br />� <br />- EDITED BY: _ RCS, TLw <br />� u SC&D PROJECT NO. 21-020 <br />Q)g FORUM PROJECT NO. 4097 <br />Q) W <br />C <br />C U <br />W z <br />z <br />o General Structural <br />p 0 Notes <br />a <br />v W <br />w <br />S z <br />4• W <br />0 <br />V1 w <br />O1 ­- <br />.1) _ <br />U <br />4-0 <br />S19-30 <br />0 0 <br />LL <br />O <br />