Laserfiche WebLink
SKILLED NURSING - 10 BED CONVERSION FLTSP15008 <br />7. Closer Accessories: Provide door closer accessories including custom templates, special <br />mounting brackets, spacers and drop plates as required for proper installation. Provide <br />through -bolt and security type fasteners as specified in the hardware sets. <br />B. Door Closers, Surface Mounted (Heavy Duty): ANSI/BHMA A156.4, Grade 1 surface <br />mounted, heavy duty door closers with complete spring power adjustment, sizes 1 thru 6; and <br />fully operational adjustable according to door size, frequency of use, and opening force. Closers <br />to be rack and pinion type, one piece cast iron or aluminum alloy body construction, with <br />adjustable backcheck and separate non -critical valves for closing sweep and latch speed control. <br />Provide non -handed units standard. <br />Acceptable Manufacturers: Basis of Design. <br />a. Norton Door Controls (NO) - 7500 Series. <br />C. Door Closers, Surface Mounted (Commercial Duty): ANSIBHMA 156.4, Grade 1 certified <br />surface mounted, institutional grade door closers with complete spring power adjustment, sizes <br />1 thru 6; and fully operational adjustable according to door size, frequency of use, and opening <br />force. Closers to be rack and pinion type, one piece cast iron or aluminum alloy body <br />construction, with adjustable backcheck, closing sweep, and latch speed control valves. Provide <br />non -handed units standard. <br />1. Acceptable Manufacturers: Basis of Design. <br />a. Norton Door Controls (NO) - 8500 Series. <br />2.9 SURFACE MOUNTED CLOSER HOLDERS <br />A. Electromagnetic Door Holders: Certified ANSI A156.15 electromagnetic door holder/releases <br />with a minimum 20 to 40 pounds holding power and single coil construction able to <br />accommodate.l2VDC, 24VAC, 24VDC and 120VAC. Coils to be independently wound, <br />employing an integral fuse and armatures to include a positive release button. <br />Acceptable Manufacturers: <br />a. Rixson (RF) - 980/990 Series. <br />2.10 ARCHITECTURAL TRIM <br />A. Door Protective Trim <br />1. General: Door protective trim units to be of type and design as specified below or in the <br />Hardware Sets. <br />2. Size: Fabricate protection plates (kick, armor, or mop) not more than 2" less than door <br />width (LDW) on stop side of single doors and 1" LDW on stop side of pairs of doors, and <br />not more than 1" less than door width on pull side. Coordinate and provide proper width <br />DOOR HARDWARE 087100 - 12 <br />