GENERAL NOTES: <br />THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2011 FLORIDA BUILDING CODE <br />6TH EDITION AND THE 2011 FLORIDA BUILDING CODE - RESIDENTIAL 6TH EDITION. <br />ARKAY ENGINEERING, INC.: A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL <br />ENGINEERING COMPANY. HAS APPLIED "RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN <br />OF THIS STRUCTURE. <br />THE BUILDING (INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE <br />FOLLOWING SUPERIMPOSED LOADS: <br />FLOOR: <br />LIVE LOAD - 50 P.S.F. <br />DEAD LOAD - 10 P.S.F. <br />ROOF: <br />LIVE LOAD (TRUSS TOP CHORD) - 20 P.S.F. <br />DEAD LOAD (TRUSS TOP CHORD) - 10 P.S.F. (15 P.S.F. WHEN TILE ROOFING IS INSTALLED) <br />DEAD LOAD (TRUSS BOTTOM CHORD) - 10 P.S.F. <br />ASSUMED TRUSS SELF WEIGHT (DEAD LOAD) - 1 P.S.F. <br />WIND: <br />BUILDING IS DESIGNED TO CONFORM TO ASCE 1-10, CHAPTERS 26 THRU 31: PER 2011 FLORIDA <br />BUILDING CODE, RESIDENTIAL 6TH ADDITION - SECTION R301.2.1.1. AND 2011 FLORIDA BUILDING <br />CODE 6TH ADDITION SECTION IbOS <br />COMPONENT 4 CLADDING WIND LOADS <br />WIND DESIGN ASSUMPTIONS: <br />BUILDING EXPOSURE - B ALL OTHER <br />BUILDING RISK CATEGORY - II BUILDING ROOF OVERHANG COMPONENT <br />MEAN ROOF HEIGHT 30' OR LESS ZONE LOADS LOADS <br />HEIGHT 4 EXPOSURE ADJUSTMENT <br />COEFFICIENT - LO I N/A +32.3/-35.3 <br />ENCLOSED BUILDING <br />INTERNAL PRESSURE COEFFICIENT - +/- 0.18 2 -65.1 +32.3/-56.2 <br />WIND SPEED SHOWN AT THE BOTTOM RIGHT <br />CORNER OF THIS SHEET 3 -110.6 +32.3/-8S.0 <br />ALL STRUCTURAL ELEMENTS, EXTERIOR 4 N/A +35.3/-38.2 <br />WALLS AND INTERIOR WALLS SHALL BE <br />TYPE V CONSTRUCTION PER FBC 602.5 5 N/A +35.3/-41.2 <br />SOIL BEARING 4 COMPACTION: <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 P.S.F. <br />(MINIMUM). THE CONTRACTOR/PROPERTY OWNER ARE RESPONSIBLE FOR VERIFYING THAT THE SOIL <br />ON THE SITE IS PROPERLY PREPARED 4 COMPACTED SUCH THAT IT CAN SUPPORT A 2,000 P.S.F. <br />FOUNDATION LOADING. <br />ARKAY ENGINEERING, INC.: A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL <br />ENGINEERING COMPANY: DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION SITE <br />NOR PERFORMING ANY SOIL TESTING. <br />ARKAY ENGINEERING, INC. SHALL NOT BE RESPONISIBLE FOR THE SITE SOILS ABILITY TO SUPPORT <br />THE BUILDING LOADS. <br />FOUNDATIONS 4 SLAB —ON —GRADE: <br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS WITHIN THE BUILDING AREA. <br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED <br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2,000 P.S.F. FOUNDATION LOADING. <br />SLAB SHALL BE PLACED OVER A 6 MIL VAPOR BARRIER ON CLEAN, ADEQUATELY <br />COMPACTED AND TERMITE POISONED SOIL. <br />CONCRETE UTILIZED IN THE FOUNDATIONS AND SLABS SHALL HAVE A MINIMUM 28 DAY <br />COMPRESSIVE STRENGTH OF 2,500 P.S.I. <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" <br />FOR 05 REBAR, 30" FOR 06 REBAR 4 35" FOR "1 REBAR. <br />PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES (AFTER <br />FINAL SITE GRADING). THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE <br />EXACT STEMWALL HEIGHT BASED UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION <br />AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSES ARE REQUIRED. <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE <br />SITE FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND <br />A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY THE REQUIRED BUILDING SETBACKS. <br />TIMBER MATERIALS. <br />ALL TIMBER MATERIALS SHALL BE AS FOLLOWS: <br />LVL BEAMS SHALL BE (1.9E) MICROLLAM LVL MATERIALS MANUFACTURED BY TRUSJOIST <br />MACMILLAN (OR EQUAL). <br />LUMBER UTILIZED IN BOTTOM PLATES, TOP PLATES, POSTS, STUD PACKS AND BEAMS <br />SHALL BE 02 YELLOW PINE (OR BETTER). <br />EXTERIOR AND INTERIOR LOAD BEARING STUDS SHALL BE 02 SPRUCE (OR BETTER). <br />ALL OTHER STUDS SHALL BE "STUD GRADE" SPRUCE. <br />PSL POSTS SHALL BE MOE) PARALLAM PSL MATERIALS MANUFACTURED BY TRUSSJOIST <br />MACMILLAN (OR EQUAL). SEE "POST SUPPORT TABLE" ON THIS SHEET FOR LOAD VALUES. <br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH -INS MUST BE COMPLETE, INSPECTED AND APPROVED <br />PRIOR TO REQUESTING THE FRAMING INSPECTION. <br />ALL LUMBER IN CONTACT WITH MASONRY WILL BE PRESSURE TREATED <br />MATERIALS <br />INTERIOR STUD WALLS TO BE OF 2 X 4 02 SPRUCE OR BETTER WITH SINGLE 2 X 4 P.T. <br />PINE BOTTOM PLATE AND SINGLE 2 X 4 01 SPRUCE TOP PLATE WITH STUDS SPACED <br />MAXIMUM 24" OC. WALLS TO HAVE 1/2" GYPSUM BOARD EACH SIDE, WITH WALLS AT <br />GARAGE TO HAVE MINIMUM R-11 INSULATION <br />SOIL TERMITE TREATMENT: <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES <br />APPLIED TO SOIL, OR WOOD, BAITING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR <br />USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. <br />A "CERTIFICATE OF COMPLIANCE" SHALL BE 15SUED TO THE BUILDING DEPARTMENT BY A LICENSED <br />PEST CONTROL COMPANY BEFORE A "CERTIFiCATE OF OCCUPANCY" WILL BE ISSUED. THE CERTIFICATE <br />SHALL STATE <br />"THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA <br />DEPARTMENT OF AGRICULTURE AND =:ONSUT-fER SERVICES." <br />IF A REGISTER£^ TERM17!CIDE BAIT SYSTEM ire TO E!E L4 ED FOR SUBTERRANEAN TERMITE PREVENTION, <br />ABOVE DO NOT ArPLY, A S!GNED rlV = YI_A.F: CONTRACT FROM THE ISSUE <br />OF THE GERvFlcr TE OF Or_CJPANC" . 56URIPIG IN6TAL.LATION, MAINTENANCE AND MONITORINC-. OF THE <br />BAITING SYSTEM SHALL ESE PROvID0:; TO BUILDING OFFICIAL PRIOR TO THE SLAB POUR. THE SYSTEM <br />MUST BE INSTALLED PRIOR TO FINAL BUIL.DiNCi APPROVAL, <br />INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION, <br />BACKFILLING 4 COMPACTION ARE COP^.PLETE <br />ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED <br />(INCLUDING ANY BOXED OR FORMED AREAS) - <br />BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE <br />WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF AN <br />ADEQUATE SIZE 4 DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE <br />INITIAL TREATMENT. <br />A MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT <br />SHALL BE REQUIRED <br />ANY CONCRETE OVERPOUR, MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER <br />MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT <br />EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 12 INCHES OF THE STRUCTURE SIDE WALLS <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER ?,HALL BE INSTALLED AFTER CONSTRUCTION IS <br />COMPLETE (INCLUDING LANDSCAPING AND IRRIGATION). ANY SOILS DISTURBED AFTER THE <br />VERTICAL BARRIER IS APPLIED, SHALL BE RE -TREATED. <br />CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12 INCHES AWAY FROM THE <br />BUILDING SIDEWALLS <br />AFTER ALL WORK IS COMPLETED, ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW <br />AND WITHIN 12 INCHES OF THE BUILDING. THIS eHALL INCLUDE ALL GRADE STAKES, TUB TRAP BOXES <br />FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS. <br />THE DISTANCE FROM THE EXTERIOR WALL COVERING (EXCEPTIONS: PAINT AND DECORATIVE <br />CEMENTITIOUS FINISHES LESS THAN 5/8 INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION <br />WALL) AND FINAL EARTH GRADE SHALL. NOT BE LESS THAN 6 INCHES To ALLOW FOR INSPECTION <br />FOR FUTURE TERMITE INFESTATIONS <br />EXTERIOR WINDOWS 4 DOOR ASSEMBLIES: <br />ALL EXTERIOR WINDOW 4 GLASS DOORS SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA <br />101/162 STANDARDS AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, <br />PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY. <br />ALL MULLIONS AND ADJACENT DOOR/WINDOW ASSEMBLIES SHALL BE TESTED OR ENGINEERED TO <br />TRANSFER 1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE. <br />INSTALL ALL WINDOW 4 DOOR ASSEMBLIES PER THE MANUFACTURERS ANCHORING RECOMMENDATIONS <br />TO ACHEIVE THE DESIGN PRESSURES SPECIFIED. <br />ELECTRICAL, FLUMBING 4 MECHANICAL: <br />IN ACCORDANCE WITH CHAPTER 411.003(2)(1) OF THE FLORIDA ADMINISTRATIVE CODE: ELECTRICAL, <br />PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTORS TO <br />MEET ALL APPLICABLE CODES. THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HEREON <br />ARE BASED UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS. <br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, GARAGE AND AT <br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND -FAULT INTERRUPTER "GFI" CIRCUIT. <br />ALL ELECTRICAL OUTLETS IN HABITABLE SPACES SHALL BE WIRED INTO AN ARC -FAULT INTERRUPTER <br />SAFETY GLAZING: <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF <br />GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308: <br />(1) GLAZING IN SWINGING DOORS, FIXED AND SLIDING PANELS OF SLIDING DOOR <br />ASSEMBLIES. <br />(2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM <br />ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS <br />THAN r00 INCHES ABOVE THE DRAIN INLET. <br />(3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE <br />THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR IN A <br />CLOSED POSITION AND WH05E BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE <br />FINISHED FLOOR OR WALKING SURFACE. <br />(4) GLAZING IN AN !NDI /IDUAL FIXED ; R CPEF.-45LE PANEL, OTHER THAN THOSE LOCATIONS <br />DESCRIBED IN ITEMS (2) 4NO (3) AE:OVE. 7,4AT MEETS ALL OF THE FOLLOWING <br />CONDITIONS: <br />A) EXPOSED AREA OF AN INDIVIDUAL I'ANE GREATER THAN S SQ, FT, <br />B) BOTTOM EDGE LESS T,4AN i8 INC"EP, ABOYF_ THE FLOOR. <br />C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR, <br />D) ONE OR MORE WALKING SURFACES JJITHIN 36 INCHES HORIZONTALLY OF THE <br />PLANE OF THE GLAZING. <br />REFER TO THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308 FOR ADDITIONAL AREAS <br />THAT MAY BE CONSIDERED A HAZARDOUS LCCATION FOR THE PURPOSE OF GLAZING. <br />PRODUCT CATEGORY <br />APPROVED PRODUCT LIST <br />SUBCATEGORY MANUFACTURER <br />STATE FLU <br />APPROVV AL <br />STRUCTURAL COMPONET <br />HUC414 <br />SIMPSON <br />FL 10531 <br />STRUCTURAL COMPONET <br />HU28, HU28-2, U24 <br />SIMPSON <br />FL 10655 <br />STRUCTURAL COMPONET <br />HIO <br />SIMPSON <br />FL 10446 <br />STRUCTURAL COMPONET <br />MSTA30 <br />SIMPSON <br />FL 10852 <br />STRUCTURAL COMPONET <br />PSL POST <br />WEYERHAEUSER <br />FL 6521.3 <br />STRUCTURAL COMPONET <br />LVL BEAMS <br />WEYERHAEUSER <br />FL 6521,2 <br />ROOFING <br />29 GA MASTER RIB <br />UNION CORRIGATED IND <br />FL 1211.10 <br />OVER 15/32" PLYWOOD <br />ROOFING <br />UNDERLAYMENT <br />GAF <br />FL 10626.1 <br />SINGLE HUNG <br />WINDOWS <br />NON IMPACT <br />PLYGEM 1500 <br />FL 16103.1 <br />WINDOWS <br />HORIZONTAL SLIDERS <br />PLYGEM 1500 <br />FL 16102.1 <br />NON IMPACT <br />WINDOWS <br />AWNING/CASEMENT <br />PLYGEM 1500 <br />FL 15531 <br />NON IMPACT <br />EXTERIOR DOORS <br />SLIDING GLASS <br />PLYGEM 4180 <br />FL 14634.4 <br />SOFFIT 4 FASCIA TRIM <br />SOFFIT AMERICAN CONSTRUCTION METALS <br />FL 12019.1 <br />WALL SIDING <br />VINYL LAP <br />CERTAINTEED CORP <br />FL 12483.1 <br />THE CLIENT UNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE <br />AGREES TO HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOSSES AND <br />EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT OF OR RESULTING FROM THE <br />PROJECT. THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION <br />DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR COST OF <br />REPAIRS OR DELAY TO THE CONSTRUCTION <br />i <br />: <br />: <br />' NON CONDITIONED SPACE <br />i <br />I <br />LEVEL_ TWO ELECTRICAL_ PLAN 1/411 11 O" <br />ELECTRICAL LEGEND <br />220 V <br />G.F.I, <br />110 V <br />GROUND FAULT <br />FLUORESCENT <br />RECEPTACLE <br />FIXTURE <br />SWITCH <br />® <br />IIOv 50 CFM S O <br />RECESS CAN LIGHT <br />BATH FAN <br />ILO v <br />WP <br />110 V <br />(( )) <br />VANITY LIGHT Q <br />ELECTRICAL PANEL <br />WATERPROOF <br />OUTLET <br />IIOV LIGHT <br />EXTERIOR <br />CAN BE CEILING <br />WALL LIGHT <br />OR WALL (TYP) <br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, GARAGE AND AT EXTERIOR LOCATIONS <br />SHALL BE WIRED INTO A GROUND FAULT INTERRUPTER "GFI" CIRCUIT <br />ALL REMAINING 15AMP/20AMP OUTLETS IN HABITABLE AREAS TO WIRED INTO A ARC -FAULT <br />INTERRUPTER "AFL" CIRCUIT <br />SMOKE DETECTORS SHALL BE PLACE IN EACH BEDROOM AND IN HALL WAY AREAS ADJACENT <br />TO BEDROOM AND OTHER LIVING AREAS <br />CARBON MONOXIDE ALARM MUST BE INSTALL WITHIN 10'0" OF EACH ROOM USED FOR SLEEPING PURPOSES <br />WHEN BUILDING HAS A FOSSIL FUEL BURNING HEATER OR APPLIANCE, A FIREPLACE OR AN ATTACHED <br />GARAGE. <br />GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N.E.C. <br />METER AND PANEL LOCATION <br />MAY VARY FROM DRAWINGS <br />LEVEL_ ONE ELECTRICAL_ PLAN 1/4" = 11 011 <br />TYPICAL ELECTRICAL RISER DIAGRAM <br />3 - 2/0 THHN CU FEEDERS <br />2" GALV RISER <br />SINGLE PHASE <br />METER SOCKET BREAKER PANEL <br />WITH MAIN <br />100 AMP <br />0 O <br />GROUND PER N.E.C. <br />3- 2/0 06 GROUND <br />2" GALV NIPPLE <br />CONCRETE ENCASED "LIFER" <br />ELECTRODE REQUIRED PER <br />CURRENT N.E.C. AND MUST <br />BE INSPECTED PRIOR TO <br />CONCRETE PLACEMENT <br />ARKAY ENGINEERING INC. \ <br />STRUCTURAL ENGINEER <br />RICHARD L. KIDDEY P.E. <br />FLORIDA LICENSE NUMBER 31296 <br />I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS <br />WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION <br />ARE IN COMPLIANCE WITH CHAPTER 16, SECTION I&O9 OF THE <br />FLORIDA BUILDING CODE 2011 6TH EDITION AND ASCE 1-10 <br />FOR 13S MPH WIND ZONE RISK CATEGORY II AND THE ENTIRE <br />2011 BUILDING CODE RESIDENTIAL 6TH EDITION <br />U <br />z <br />M <br />M <br />nLL <br />LL <br />J <br />)0 <br />N-1 <br />z Lu <br />❑ N <br />i <br />C) 0 <br />Va <br />W ❑ N <br />W <br />C7 Q LO <br />A <br />Z M <br />a <br />ED U <br />U_ <br />CO00 <br />0 <br />N <br />00 <br />M <br />r T_ <br />� M <br />0� <br />QQ cQ ; <br />44nu��llll ��qq o <br />Mc4�V <br />U. <br />zm- do <br />C O) 01L <br />Q) 5, 01 <br />� Q� W <br />m <br />3 aio <br />'Q cq 0 Y <br />W'au_-1 <br />W <br />4L <br />3 <br />r_ <br />N <br />0 <br />tl.lM <br />j <br />z <br />Q <br />Q <br />A <br />lu <br />V <br />1---i <br />T <br />JU <br />v, <br />_ <br />U <br />0 <br />� <br />'�11 <br />lu <br />O <br />V/ <br />LEVEL ONE <br />STORAGE <br />438 <br />LEVEL TWO <br />STORAGE <br />556 <br />SCREEN <br />PORCH <br />112 <br />RV <br />CARPORT <br />542 <br />TOTAL 1648 <br />PG <br />4OF4 <br />ARKAY 0 19224 <br />4 �1 <br />