Laserfiche WebLink
ENGINEERED ROOF PER ASCE 7-16 ROOF DESIGN ALLOWABLE COMPONENTS AND <br />RSN CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT 5 25 ft <br />JIND SPEED (ULTIMATE) 140.0 MPH <br />JIND SPEED (ALLOWABLE) 108.4 MPH <br />.XPOSURE CATEGORY C <br />EFFECTIVE WIND PRESSURE AND SUCTION (PSF) <br />WIND AREA (+) VALUE DENOTES PRESSURE HIP ROOF >20 TO 45 DEG. <br />(SQ FEET) (-) VALUE DENOTES SUCTION [4:12]-[12:12] <br />a=oft <br />AREA ROOF 1 2e 2n 2r 3 3e 3r <br />10 HIP -35.94 -49.57 49.57 49.57 77 <br />GABLE -38.22 -38.22 -60.99 -60.99 -60.99 -78,58 <br />ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ROOF SHEATHING: <br />SHINGLE: Y%" EXP. 1 (24/6) or 15/32" EXP. 1 (3�116) <br />TILE: t%32' EXP. 1 (32/16) <br />NOTE: <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 %" x 0.113") NAILS <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1Y32", SHEATHING SHALL BE FASTENED <br />WITH ASTM F1667 RSRS-03 10d (2Y2" x 0.131 ") NAILS OR ASTM F I V RSRS-04 (3" x .120") NAILS <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />a=4ft <br />GABLE ROOF > 20 TO 45 DEG. <br />[4:12]-[12:12] <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. <br />Q <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />META12 <br />1420 <br />9 - 10d x 1 1/2" <br />HTA20 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />A (2) <br />(2)META12 <br />1875 (1)PLY <br />1795 (2)PLY <br />9 - 10d x 1 1/2" <br />B <br />HETA16 <br />1810 <br />9 - 10d x 1 1/2" <br />HTA16 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />C <br />H2.5A <br />565 <br />535 <br />10 - 8d <br />RT7A <br />585 <br />515 <br />10 - 8d x 1 1/2" <br />D <br />H3 <br />400 <br />320 <br />8 - 8d <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />7 -10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1400 <br />10 - 10d x 1 1/2" <br />F <br />HHETA20 <br />2120 <br />10 - 10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 - 10d x 1 1/2" <br />G <br />H10A <br />1040 <br />1015 <br />18 - 10d x 1 1/2" <br />RT16A <br />1020 <br />1160 <br />9 - 10d x 1 1/2"& 8-10d <br />H <br />FGTR <br />4725 <br />3400 <br />w/ (18) 1/4" x 3" SDS <br />WOOD SCREWS AND (2) <br />1/2" x 5" TITEN HD ACHOR <br />BOLTS <br />RFUS <br />7100 <br />--- <br />w/ (12) WS3 WOOD <br />SCREWS AND (4) 3/4" x 6" <br />WEDGE -BOLTS <br />J <br />HTT5 <br />4350 <br />3740 <br />5/8" ANCH. / (26) 10dxl-1/2" <br />HTT5 <br />5795 <br />5/8" ANCH. /(26) 10d x1-1/2 <br />K <br />HD3B * <br />3130 <br />3050 <br />5/8" DIA. BOLTS <br />TDX2-TZ <br />3295 <br />--- <br />2 - 5/8" DIA. BOLTS <br />L <br />VGT R/L <br />2225 <br />1600 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 wl (10) 1/4" <br />X 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />M <br />VGT - F <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />x 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />N <br />LUS26 <br />1165/1060 <br />1005/915 ** <br />8 - 10d x 3" <br />JUS26 <br />1000/1080** <br />--- <br />8 -10d <br />P <br />HUS26 <br />1320/3235 ** <br />1335/2820 ** <br />20 - 16d x 3 1/2" <br />HUS26 <br />2035/340Q <br />- <br />(20)16d x 3-1/2" <br />Q <br />HUS28 <br />1760/4095 ** <br />1720/3125 ** <br />30 - 16d x 3 1/2" <br />HUS28 <br />2950/5090 <br />--- <br />30d -16d x 3-1/2" <br />R <br />MTS12 <br />990 <br />860 <br />14 - 10d x 1 1/2" <br />MTW12 <br />1195 <br />1005 <br />14-10d x 1-1/2" <br />S <br />VGT - M <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND (1) <br />5/8" ATR EPDXIED w/ <br />SIMPSON SET w/ 12" MIN. <br />EMBEDMENT. <br />T <br />(2) LGT3 <br />6570-M 6960-F <br />4730-M 5010-F <br />w/ (24) 1/4" x 3" SDS <br />SCREWS & (8) 3/8" x 5" <br />TITEN HD (2 PLY) OR (52) <br />16D SINKERS FOR FRAME <br />U <br />MGT <br />3965 <br />3330 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ SIMPSON "SET" <br />EPDXY <br />MUGT15 <br />4175 <br />22 -10d x (1) 5/8" ATR wl 12" <br />EMBED w/ USP CIA-7000C <br />EPDXY <br />V <br />(2) LGT2 <br />4060-M 3770-F <br />3500-M 3240-F <br />w/ (32) 16D SINKERS & <br />(14) 1/4" x 2 1/4" TITENS <br />(2 PLY) OR (28) 16D <br />SINKERS FOR FRAME <br />LUGT2 <br />3100-M 4520-F <br />3100-M 3800-F <br />w/ (32) 16D SINKERS & <br />(10) 1/4" x 3" WEDGE- <br />BOLTS (2-PLY) OR (32) 16 <br />SINKERS FOR FRAME <br />"X" <br />HTS 20 <br />1310 <br />1245 <br />24-10d x 1 1/2" <br />HTW20 <br />1530 <br />1285 <br />24-10d x 1 1/2" <br />SP1 <br />555 <br />535 <br />1 10-10d <br />SPT22 <br />735 <br />8-10d <br />SP2 <br />1010 <br />605 <br />1 12-10d <br />SPT24 <br />1090 <br />12-10d <br />HCP2 <br />590 <br />555 <br />1 12-10d x 1 1/2" <br />HHCP2 <br />1 680 <br />570 <br />(20)10d x 1-1/2" <br />* MINIMUM 3" MEMBER <br />** REACTIONS ARE FOR ROOF LOADS ONLY <br />'** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. <br />REVISED 12-02-20 <br />LOADS -- ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") <br />*FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (**). <br />INTERSECTING POINT TO BE FASTENED WITH 2 - 16d COMMON NAILS OR 0.128" x Y GUN <br />NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (8) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. R1 <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS wO <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 6-0" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS <br />1 (2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />(A) <br />OR 2 PLY <br />:ARRIER <br />FX CONT LEDGER (A) <br />SEE SHEET D1 FOR <br />ROOF FRAMING <br />DETAILS <br />ROOF FRAMING PLAN - ELEV-B1 <br />SCALE: %4"=V-0" <br />rc <br />`o <br />=r <br />U <br />' <br />0 -0 C cc <br />o- = c <br />c <br />'m o <br />ar 3 Y <br />cc d u <br />c <br />�cy-,CC <br />� E <br />CD <br />0 <br />SRO �v 10, <br />. <br />• <br />4S <br />s <br />_ `Q <br />�'S'p�•SS104��\ <br />laf�ff�P]IIli'�i 0%; <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specificat ons contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages hearing <br />Engineers <br />signature and seal. <br />W <br />E <br />N <br />o6 C:C � W N N <br />to <br />Lo t*- <br />iq <br />4 <br />,n <br />CLLN <br />Qj M v CF <br />� u w <br />cc L.L d <br />— v a <br />•L <br />L as q <br />W <br />o 0 <br />= 'CU N (O 0 <br />W <br />��Q'°' m <br />Z <br />LL <br />N- N Z Q J <br />O U08 <br />W <br />N c[7 <br />� o <br />z � <br />z o <br />Q <br />V 1 <br />- N <br />z V <br />(V <br />W <br />(3) <br />oc <br />LL <br />4(-r�1t <br />cn <br />0 <br />w g <br />Ly N <br />v <br />w <br />E-- _ � <br />t 3 <br />1 <br />C) o <br />Of CO <br />z� <br />®o <br />Q N <br />�� <br />C:,w <br />f0 <br />M <br />M <br />zo <br />Z <br />U_ <br />O <br />E <br />zo <br />oo <br />�z <br /><� <br />z® <br />oa <br />F@ <br />R� <br />V <br />aF <br />00 <br />❑0 <br />O <br />O <br />CV <br />L <br />¢z <br />O <br />G� <br />wz <br />r0 <br />v <br />2 <br />mi <br />o <br />zz. <br />zC <br />fn J <br />m <br />a� <br />¢ w <br />�Z <br />cl <br />a� <br />w <br />go <br />a <br />� k <br />W <br />U <br />d� <br />= <br />069 <br />Y <br />F <br />� <br />0 <br />W Iz <br />z1a <br />ao <br />3 <br />O <br />LO <br />J <br />Li / <br />� <br />m <br />m <br />r� <br />Q <br />C� <br />� <br />Imo— <br />N <br />LO <br />J <br />Y <br />Cr T <br />r <br />0 <br />U <br />(n o <br />CD <br />N <br />m <br />LO <br />r <br />� <br />� <br />LL N <br />C) <br />0 <br />N_ O <br />In <br />N <br />LO <br />r <br />ai <br />m <br />w <br />N <br />CD r.0 <br />CY) N <br />o <br />Z <br />0 <br />E <br />N r <br />L <br />c <br />d <br />U <br />y <br />Q p <br />.10B <br />NO: <br />22-12367 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />7.1 <br />