ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />UNDERGROUND is <br />SERVICE BY POWER CO.--�_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17, 250.94 <br />150A/200A INDOOR <br />PANEL CENTER q <br />10 #14 to lights & outlets <br />R III <br />NEMA 1 #12 to appliances and GFI <br />150 AMP/ <br />200A101 0 11t0 to WH �\ <br />#8 to Range <br />#6 to H VAC <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FPc <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />a <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />�]M <br />ELECTRIC METER <br />A <br />ELECTRIC PANEL <br />_=,=L <br />DISCONNECT SWITCH <br />�i <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />Ci T J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />V L-nilt IVI{- I Lfl <br />LOCATION WITH <br />BUILDER <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />MAIN FLOOR ELECTRICAL PLAN - ELEV-B1I <br />SCALE: ,._„o. <br />r <br />b <br />o •� E <br />=o <br />� <br />o <br />.,tC s <br />t <br />3 cc <br />,.. <br />cu <br />c� <br />T <br />N. <br />i� <br />ji <br />N <br />0 <br />CV <br />C.O <br />0 <br />CV <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />W <br />a <br />8E <br />o <br />r <br />Fm <br />A 0 <br />N CV O <br />0 <br />�� <br />J��� u-5 <br />(� <br />NMCLL <br />'a. wo <br />L'- <br />0 <br />L a <br />Z <br />o <br />Nit�eg_�o <br />W <br />N_�W <br />Z <br />m w <br />LIL O N Z <br />Z <br />N O U 8 <br />W <br />❑ ❑ <br />`D M V <br />z N M <br />O <br />z co N <br />0 <br />z � � <br />a <br />CL <br />N <br />N <br />M <br />z a <br />U 8 <br />4—J <br />fa <br />c- <br />w Co <br />[� <br />V <br />0^ <br />V) <br />W o <br />Cam' N. <br />U <br />I <br />w 2a <br />po� <br />U <br />L <br />m <br />«r`• <br />U o N <br />4m, <br />� <br />W <br />M <br />09 <br />z <br />1 <br />LPL <br />zo <br />D LL <br />g <br />zo <br />a N <br />E �V <br />tj5 <br />j <br />Z <br />°wit <br />p <br />C6 <br />r— C <br />o <br />XU <br />�0 <br />- Z <br />Z <br />D E <br />CV <br />E 8 <br />¢z <br />0 <br />¢ o <br />�z <br />¢ u, <br />L <br />to <br />U.)m c <br />m <br />m o <br />ZZ <br />Z <br />J <br />¢w <br />�w <br />2 <br />{ <br />NW <br />z0 <br />5 <br />N <br />C2 5 <br />U� <br />o< <br />LL <br />wag <br />n <br />w <br />=� <br />of <br />Jz <br />c�3 <br />co <br />a� <br />o� <br />V <br />zIa <br />0 3 <br />`0 <br />Lo <br />J <br />LLO <br />rn <br />cm <br />cc <br />Q <br />0 <br />T <br />T <br />Cr <br />Y <br />r <br />j o <br />N <br />U/ m <br />LO <br />'.� <br />C J <br />d7l <br />Co <br />U_ CV <br />O <br />0 <br />N <br />Lo <br />NLO <br />T <br />c� <br />rt- <br />ai <br />M N <br />o <br />E <br />N <br />O <br />�' r <br />Z <br />to <br />c <br />co <br />a <br />E <br />U° <br />2 <br />.g ai <br />a o <br />v <br />v <br />JOB <br />NO: <br />22-12367 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.