<br />HYAG LEOEND
<br />AHU-I
<br />EQUIPMENT DE-516NATION
<br />\\-TA6
<br />O
<br />THERM05TAT (PROVIDED BY MECHANICAL
<br />CONTRACTOR)
<br />OHUMIDISTAT
<br />(PROVIDED BY LENNOX)
<br />O
<br />WALL TIMER SWITCH (PROVIDED BY
<br />MECHANICAL CONTRACTOR)
<br />®
<br />REMOTE TEMPERATURE 4 HUMIDITY SENSOR
<br />(PROVIDED BY UNIFY)
<br />®
<br />MASTER TEMPERATURE AND HUMIDITY SENSOR
<br />WITH USER INTERFACE. ('PROVIDED BY UNIFY)
<br />TIMED LOCAL OVERRIDE L16HTIN6 SWITGH
<br />SFD
<br />COMBINATION SMOKE/FIRE DAMPER
<br />FD
<br />FIRE DAMPER
<br />®
<br />GEILIN6 DIFFUSER
<br />zRETURN
<br />GRILLE
<br />zEXHAUST
<br />GRILLE
<br />FTA(,5SIZE
<br />50 AIR DISTRIBUTION DE516NATION
<br />\_GFM
<br />SIDEWALL REGISTER
<br />i MOTOR OPERATED DAMPER
<br />MANUAL OPERATED DAMPER
<br />i
<br />TURNING VANES
<br />OSMOKE DETECTOR
<br />C@ CARBON MONOXIDE DETEGTOR
<br />TRANSFER OPENING
<br />SIZE
<br />ii NEW DUCTWORK
<br />t_ _ _ _ I EXI5TIN6 DUCTWORK TO REMAIN
<br />�-x-x- x- -x -Z
<br />V111ZIM,
<br />EXISTING DUCTWORK TO BE REMOVED
<br />Q� I CONNECT TO EXI5TIN6 (POINT OF CONNECTION)
<br />AFF
<br />ABOVE FINISHED FLOOR
<br />DB
<br />DRY BULB
<br />GFM
<br />CUBIC FEET PER MINUTE
<br />DDG
<br />DIRECT DIGITAL CONTROL
<br />EF
<br />EXHAUST FAN
<br />EAT
<br />ENTERING AIR TEMPERATURE
<br />EWT
<br />ENTERING WATER TEMPERATURE
<br />ESP
<br />EXTERNAL STATIC PRESSURE
<br />IN. W.G.
<br />INCHES WATER GAUGE
<br />LAT
<br />LEAVING AIR TEMPERATURE
<br />LWT
<br />LEAVIN6 WATER TEMPERATURE
<br />OA
<br />OUTSIDE AIR
<br />RA
<br />RETURN AIR
<br />WB
<br />WET BULB
<br />TEST � B,4LANGE /SYSTEM GOMM I SS I ON I N6:
<br />SYSTEM COMMISSIONING:
<br />AFTER CONSTRUCTION, THE ENTIRE HVACSYSTEM SHALL BE VERIFIED, TESTED, ADJUSTED,
<br />AND BALANCED BY AN INDEPENDENT NEBB OR AABC TEST AND BALANCE AGENCY TO
<br />DELIVER THE AIR AND/OR KATER QUANTITIES SHOWN ON THE DRAWINGS. THE REPORT 15 TO
<br />INCLUDE:
<br />I. HVAC UNITS (RTU'S, FURNACES, AHU'S, ENER6Y RECOVERY UNITS, ETC):
<br />A. BALANCED AIR QUANTITIES TO WITHIN 10% +/- OF THE SUPPLY INDICATED ON THE
<br />DESIGN DOCUMENTS (DO NOT BALANCE RETURN AIR UNLESS SPECIFICALLY NOTED
<br />ON THE DOCUMENTS).
<br />B. PROVIDE TRAVERSE READINGS FOR P051TIONIN6 OF VENTILATION (OUTSIDE AIR)
<br />AT RTU INTAKE HOOD AND/OR DUCTWORK FOR AHU'S, FURNACES, ETC.
<br />PROPORTIONAL ADJUSTMENT OF VENTILATION BASED ON SUPPLY AIR QUANTITY
<br />MINUS RETURN AIR QUANTITY 15 NOT ACCEPTABLE.
<br />C. DATE OF BALANCING
<br />D. OUTDOOR AMBIENT CONDITIONS INCLUDING; TEMPERATURE AND HUMIDITY LEVEL.
<br />E. RETURN AIR TEMPERATURE (KBdDB)
<br />F. MIXED AIR TEMPERATURE (H54D5)
<br />6. DISCHARGE AIR TEMPERATURE (P04015) AT THE COIL
<br />H. 1215CHAR6E AIR TEMPERATURE (V64D13) AT THE AIR DISTRIBUTION TERMINAL
<br />I. REFRIGERANT CHARGE (SPLIT SYSTEMS ONLY)
<br />J. MOTOR ROTATION
<br />K. AMPERAGE READINGS FOR MOTORS AND COMPRESSORS
<br />CONTROL SEQUENGE
<br />I. AIR HANDLING UNIT THERMOSTATS ARE TO BE PROGRAMMED SUCH
<br />THAT EVAPORATOR FANS RUN CONTINUOUSLY DURING OCCUPIED
<br />PERIODS. FANS ARE TO CYCLE DURING UNOCCUPIED MODES.
<br />2. EXHAUST FAN5 NOTED IN THE FAN SCHEDULE AS, CONTROLLED BY
<br />TIME CLOCK ARE TO RUN CONTINUOUSLY DURIN6 OCCUPIED PERIODS.
<br />L. VERIFY PR06RAMMIN6 OF THERM05TATS/EM5
<br />L.I. UNITS ARE TO BE SET TO THE FOLLOWING:
<br />L.I.I. MINIMUM 7 DAY PR06RAMMIN6 CYCLE
<br />L.1.2. UNITS EVAPORATOR FAN TO OPERATE CONTINUOUSLY DURIN6 OCCUPIED
<br />MODE AS, DETERMINED BY OWNER'S PERSONNEL. THERM05TATS INSTALLED
<br />SHOULD HAVE THE ABILITY TO SEPARATELY SCHEDULE EVAPORATOR FAN
<br />RUN TIME, IF NOT REPORT THIS TO GENERAL CONTRACTOR FOR IMMEDIATE
<br />CORRECTION.
<br />L.1.3. UNIT EVAPORATOR FANS ARE TO CYCLE DURING UNOGCWIED/SETBACK
<br />MODES.
<br />2. EXHAU5T 5Y517EM5:
<br />A. BALANCED AIR QUANTITIE5 TO WITHIN 1096 +/- OF THE SUPPLY INDICATED ON THE
<br />DE516N DOCUMENTS
<br />B. MOTOR ROTATION
<br />C. VERIFY PR06RAMMIN6 OF TIME CLOCKS/EMS
<br />G.I. UNITS ARE TO BE SET TO THE FOLLOWING:
<br />G.I.I. MINIMUM 7 DAY PROGRAMMING CYCLE
<br />0.1.2. FANS ARE TO BE SET ON THE EXACT SAME OPERATING SCHEDULE AS THE
<br />HVAC UNITS EXCEPT AS, NOTED ON THE "EXHAUST FAN SCHEDULE" ON THE
<br />DE516N DRAWIN65.
<br />0.1.3. VERIFY AND REPORT CONTROL DEVICE FOR ALL FANS (SWITGH, TIME
<br />CLOCK, EMS, MARK -TIMER, ETC.
<br />3. REPORT SHALL INCLUDE DRAWING OR SCHEMATIC INDICATING THE LOCATION OF EACH
<br />OUTLET WITH REFERENCE TO MEASURED AIR FLOW QUANTITY.
<br />4. PROVIDE FOUR (4) COPIES OF REPORT TO ARCHITECT.
<br />PENETRATION OF NON -RATED PARTITION
<br />NOTES:
<br />I. ANNULAR SPACE BETWEEN PENETRATING ITEM AND NON -RATED PARTITION (SMOKE PARTITION) SHALL BE A
<br />MAXIMUM OF 1/4".
<br />2. SEAL ANNULAR SPACE WITH NON -RATED AND NON-COMBUSTIBLE SEALANT, HILT[ GP 506 OR EQUAL.
<br />3. SEE ARCHITECTURAL LIFE SAFETY PLAN FOR WALL RATIN65.
<br />MEGHANIGAL SPEGIFIGATIONS
<br />C
<br />L
<br />AND NOTES
<br />4- 0
<br />L �
<br />3
<br />C,
<br />z
<br />;occ
<br />I.
<br />ALL MECHANICAL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE 2020 FLORIDIA MECHANICAL CODE WITH
<br />o 0
<br />co
<br />ALL STATE AND LOCAL AMENDMENTS, THE STATE ENER6Y CODE, NFPA qOA, NFPA 101 AND ANY LOCAL ORDINANCES.
<br />a
<br />w c
<br />+J
<br />2.
<br />ALL MECHANICAL EQUIPMENT REQUIRING ELECTRICAL POWER SHALL BE INSTALLED WITH DISCONNECT 5NITGHE-5 AT
<br />EACH PIECE OF EQUIPMENT. COORDINATE SWITCH REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. IT 15 THE
<br />� o
<br />0)
<br />CONTRACTOR'S RESPONSIBILITY TO COORDINATE ALL ELECTRICAL REQUIREMENTS.
<br />cri c
<br />L
<br />�
<br />3.
<br />THE SMOKE DETECTOR INDICATED ON THE DRAWIN65 SHALL BE WIRED TO STOP THE FAN UPON DETECTION OF
<br />o
<br />ai
<br />SMOKE, AND 516NAL THE BUILDING FIRE ALARM 5Y5TEM (IF APPLICABLE). IF THE BUILDING HAS NO FIRE ALARM
<br />v a
<br />SYSTEM, THE DETECTOR SHALL CAUSE AN AUDIBLE AND VISUAL ALARM IN A NORMALLY OCCUPIED AREA.
<br />4.
<br />SUPPLY, RETURN, AND EXHAUST DUGTINORK SHALL BE CONSTRUCTED OF 6ALVANIZED SHEET METAL AS,
<br />RECOMMENDED IN SMAGNA DUCT CONSTRUCTION STANDARDS, LATEST EDITION. DUCTWORK SHALL BE CONSTRUCTED
<br />TO WITHSTAND THE PRESSURES INDICATED ON THE DRAWIN65. ALL JOINTS AND SEAMS IN ALL SHEET METAL
<br />DUCTWORK SHALL BE SEALED WITH DUCT SEALER. DUCT 5UPPORT5 AND ATTACHMENT TO STRUCTURE SHALL BE AS,
<br />PER SMACNA STANDARDS. NEW DUCTWORK SHALL BE INSTALLED AS HIGH AS PO5515LE. ROUND LOW VELOCITY
<br />DUCTWORK SHALL BE FABRICATED OF GALVANIZED STEEL WITH LOCK TYPE SPIRAL 5EAM5 IN ACCORDANCE WITH
<br />SMACNA DETAILS AND STEEL 6AU6E THICKNESS A5 L15TED IN THE SMAGNA MANUAL, BUT NOT LE55 THAN 26 6AU6E
<br />„
<br />THICKNESS. DUCT SYSTEM SHALL BE A5 MANUFACTURED BY UNITED SHEET METAL, 5EMCO, HRANEC 5MI, OR
<br />APPROVED EQUAL. ALL ROUND DUCTWORK FITTIN65 SHALL BE PRE%ED OR WELDED. ADJUSTABLE ELBOWS OR
<br />FITTINGS WILL NOT BE ACCEPTED.
<br />5.
<br />FIRE DAMPERS SHALL BE INSTALLED IN LOCATIONS SHOWN AND IN ALL PENETRATIONS OF RATED WALLS
<br />PER THE MANUFACTURER'S UL LISTED INSTALLATION INSTRUCTIONS. FIRE DAMPERS SHALL HAVE BLADE
<br />�
<br />STACKS OUT OF THE AIRSTREAM. AT CONTRACTOR'S OPTION, FIRE DAMPERS MAY BE DELETED FROM PENETRATIONS
<br />OF FIRE BARRIERS WHERE ANY OF THE FOLLOWING APPLY:
<br />�
<br />A. PENETRATIONS ARE TESTED IN ACCORDANCE WITH ASTM E IIq OR UL 263 AS PART OF THE
<br />C
<br />FIRE-RE515TANCE-RATED ASSEMBLY.
<br />V
<br />OR
<br />B. SUCH WALL5 ARE PENETRATED BY DUCTED HVAC SY5TEM5, HAVE A REQUIRED FIRE-RE515TANGE RATING
<br />.� Q
<br />cr)
<br />OF I HOUR OR LE55, ARE IN AREAS OF OTHER THAN GROUP H AND ARE IN BUILDIN65 EQUIPPED THROUGHOUT
<br />cr)
<br />WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION g03.3.1.1 OR gO50.12 OF THE
<br />M
<br />INTERNATIONAL BUILDING CODE. FOR THE PURP05E5 OF THIS EXEMPTION, A DUCTED HVAG SYSTEM SHALL BE
<br />Q a
<br />A DUCT SYSTEM FOR THE STRUCTURE'S HVAC SYSTEM. SUCH A DUCT SYSTEM SHALL BE CONSTRUCTED OF
<br />SHEET STEEL NOT LESS THAN 26 GAGE (0.0217 INCH) THICKNE55 AND SHALL BE CONTINUOUS FROM THE
<br />AIR -HANDLING APPLIANCE OR EQUIPMENT TO THE AIR OUTLET AND INLET TERMINAL5.
<br />z
<br />(n Q
<br />0
<br />=3
<br />o w
<br />0
<br />WHERE FIRE DAMPERS ARE NOT USED PER EITHER OF THE TWO ABOVE EXCEPTIONS, THE
<br />oJc
<br />O w
<br />r
<br />ago
<br />PENETRATION SHALL BE PROTECTED BY AN APPROVED FIRE5TOP SYSTEM INSTALLED AS TESTED
<br />°0
<br />IN ACCORDANCE WITH A5TM E 814, WITH A MINIMUM P051TIVE PRE55URE DIFFERENTIAL OF O.OI INCH
<br />z Q
<br />cch
<br />OF WATER AND SHALL HAVE A TEMPERATURE RATING OF NOT LE55 THAN THE REQUIRED FIRE-
<br />X V
<br />0 H
<br />M M
<br />RE-515TANCE RATIN6 OF THE WALL PENETRATED.
<br />LO
<br />Q
<br />o
<br />L
<br />H J
<br />1. X
<br />Q CV
<br />co
<br />U_
<br />6. FLEXIBLE DUCTWORK SHALL BE FLEXMA5TER TYPE 3 OR EQUAL, SAME SIZE AS, DIFFUSER NEGK5, MAXIMUM 6'-0"
<br />LONG. FLEXIBLE DUCTWORK 514ALL BE INSTALLED AS, STRAIGHT A5 POSSIBLE, AND SHALL BE ROUTED AND
<br />SUPPORTED WITHOUT FORMING CRIMPS OR OTHER AIR FLOW RESTRICTIONS.
<br />7. CONDENSATE FROM ALL AIR CONDITIONING EQUIPMENT SHALL BE TRAPPED AND ROUTED TO THE NEAREST DRAIN.
<br />CONDENSATE PIPIN6 SHALL BE SCHEDULE 40 PVC. PROVIDE CONDENSATE PUMP IF REQUIRED COORDINATE POWER
<br />REQUIREMENTS. PUMPS SHALL BE MOUNTED WITHIN OVERFLOW PANS.
<br />8. AFTER CON5TRUGTION, THE ENTIRE HVAC SYSTEM SHALL BE TESTED, ADJUSTED, AND BALANCED BY AN
<br />INDEPENDENT NEBB OR AABG TEST AND BALANCE AGENCY TO DELIVER THE AIR AND WATER QUANTITIES SHOWN
<br />ON THE DRAWIN6_75. PROVIDE FOUR (4) COPIES OF REPORT TO ARCHITECT.
<br />q. MOUNT THERMOSTATS AND WALL SEN50R5 54" AFF UNLESS, NOTED OTHERWISE.
<br />10. MANUAL OVER -RIDE CONTROL (EMER6ENGY SHUT -DOWN) SWITGH FOR ALL NEW HVAC UNITS SHALL BE LOCATED
<br />ADJACENT TO FIRE ALARM ANNUNCIATOR PANEL OR OTHER LOCATION APPROVED BY LOCAL AUTHORITY HAVING
<br />JURISDICTION IN ACCORDANCE WITH NFPA CIOA SECTION 6.2. ONE SWITCH SHALL BE USED TO 6LOBALLY SHUT -DOWN
<br />ALL UNITS. SHUT -DOWN SNITCH SHALL BE PROVIDED WITH CLEAR, FLIP -UP PROTECTIVE COVER.
<br />11. SHOP DRAWIN65 SHALL BE SUBMITTED TO AND APPROVED BY THE ARCHITECT PRIOR TO ORDERING ANY
<br />EQUIPMENT OR INSTALLING ANY DUCTWORK OR PIPING.
<br />12. ALL MECHANICAL EQUIPMENT SHALL BE INSTALLED AGGORDIN6 TO MANUFACTURER'S RECOMMENDATION5.
<br />13. ALL MECHANICAL EQUIPMENT AND 5Y5TEM5 SHALL BE GUARANTEED FOR A PERIOD OF FIVE YEARS
<br />AFTER ACCEPTANCE BY OWNER. NO INTERNAL LINER TO BE USED.
<br />14. SHEET METAL SUPPLY, RETURN, 4 OUTSIDE AIR DUCTWORK SHALL BE INSULATED WITH 2" THICK EXTERIOR FIBERR6LA55
<br />DUCT INSULATION WITH FOIL VAPOR BARRIER, U.L. LISTED, MINIMUM R-6. ALL INSULATED DUCTWORK SHALL BE
<br />EXTERNALLY WRAPPED; THERE SHALL BE NO INTERNALLY LINED DUGTYVORK UTILIZED ON THI5 PROJECT.
<br />15. DUCTWORK DIMENSIONS 5HOYVN ON THE DRAWINGS ARE IN51DE CLEAR.
<br />16. PRIOR TO PURCHASING ANY MATERIALS OR 5TARTIN6 ANY WORK, CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
<br />CONDITIONS, DUGTWORK AND PIPING SIZE-5 AND LOCATIONS, EQUIPMENT, ETC. SHOWN ON THE DRAWINGS OR
<br />AFFECTING THE WORK AND SHALL REPORT ANY DEVIATION5 TO THE ARCHITECT.
<br />I-f. ANY EXISTING WALL, FLOOR, OR GEILIN6 SURFACE THAT 15 DISTURBED DURING THE COURSE OF THE WORK SHALL BE
<br />REPAIRED.
<br />18. LOCATION5 OF DU6TV4ORK, GRILLES, RE615TER5, AND DIFFUSERS SHOWN ON THE DRAWINGS ARE APPROXIMATE.
<br />COORDINATE EXACT LOCATIONS WITH ARCHITECT AND OWNER.
<br />Iq. AS, -BUILT DRAWINGS SHALL BE MAINTAINED BY THE CONTRACTOR DURING CONSTRUCTION INDICATING ALL FIELD
<br />GHAN&E5 AND REVISIONS TO EQUIPMENT, DUGTYVORK, PIPING AND CONTROLS. THESE DRA44IN65 SHALL BE
<br />SUBMITTED TO THE ARCHITECT UPON COMPLETION OF THE PROJECT.
<br />20. THE CONTRACTOR SHALL PREPARE TWO COPIES OF OPERATION AND MAINTENANCE MANUALS FOR THE PROJECT
<br />FOR THE OWNER'S USE. THE CONTRACTOR SHALL ALSO INSTRUCT THE OWNER'S REPRESENTATIVE IN THE OPERATION
<br />OF ALL SY5TEM5 AND THE MAINTENANCE REQUIRED.
<br />21. ALL REQUIRED CONTROL WIRING NOT SHOWN ON THE ELECTRICAL DRAWINGS SHALL BE INCLUDED A5 PART OF THE
<br />MECHANICAL WORK. WIRING IN HVAC PLENUM SPACES SHALL BE INSTALLED AC CORDING TO CODE REQUIREMENTS.
<br />EQUIPMENT SHALL BE CONTROLLED AS, INDICATED ON THE DRAWINGS.
<br />22. EQUIPMENT SHALL BE CONTROLLED BY RESPECTIVE INDIVIDUAL PROGRAMMABLE THERM0 TAT5, OR AS OTHERWISE
<br />SPECIFIED.
<br />23. ALL PIPE PENETRATIONS OF FIRE AND/OR SMOKE -RATED A55EMBLIE5 SHALL BE FIRE -STOPPED AS, REQUIRED TO
<br />RESTORE A55EMMY TO ORIGINAL INTEGRITY. FIRE BARRIER PRODUCTS SHALL BE AS, MANUFACTURED BY 3M CO.,
<br />GP25 CAULK, GSM5 COMPOSITE PANEL, F5M5 WRAP/STRIP, OR P55 7gO0 5ERIE5 SYSTEMS AS RECOMMENDED BY
<br />MANUFACTURER FOR PARTICULAR APPLICATION, OR EQUIVALENT SY5TEM AS, APPROVED BY LOCAL CODE
<br />OFFICIALS.
<br />24. ALL PIPIN6 SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON GEILIN6 TILE5 OR GEILIN6
<br />STRUCTURE. PIPING HUNG FROM JOISTS SHALL BE HUNG FROM THE TOP GHORD5 OF THE J015T5.
<br />25. WHERE SPLIT SYSTEM LINE 5ET5 BETWEEN EVAPORATOR AND CONDENSER EXCEED MANUFACTURER'S FACTORY
<br />CHARGE LENGTH (50 FEET) AND/OR LIFT HEIGHT, CONTRACTOR SHALL INCLUDE IN SHOP DRAWING 5UBMITTAL:
<br />- PROP05ED LINE 5ET D I MEN51 ONS (DIAMETER AND LEN6TH).
<br />- ADDITIONAL SYSTEM REFRIGERANT AND/OR OIL GHAR6E.
<br />- PROPOSED SYSTEM OPTIONS (CRANKCASE HEATER, ACCUMULATOR, EXPAN51ON5 VALVE, ETCJ.
<br />- SUCTION RISER TRAPS (QUANTITY AND LOCATION).
<br />26. REFRIGERANT PIPING SHALL BE TYPE L COPPER TUBIN6 WITH BRAZED JOINTS. SUCTION PIPING SHALL BE INSULATED
<br />WITH 3/4" OL05ED CELL INSULATION. ALL JOINTS AND SEAMS SHALL BE SEALED WITH ADHESIVE. REFRIGERANT
<br />PIPING PASSING THROUGH FLOORS SHALL BE ENCLOSED IN A CONTINUOUS FIRE RESISTIVE PIPE SHAFT HAVING NO
<br />OPENINGS INTO FLOORS NOT SERVED BY THE REFRIGERATING SYSTEM, AS REQUIRED BY LOCAL CODE
<br />AUTHORITIES. THE PIPE SHAFT SHALL BE VENTED TO THE OUTDOORS.
<br />27. INSTALL OUTDOOR AIR CONDITIONING EQUIPMENT LEVEL ON 4" THICK REINFORCED CONGRE I PADS EXTENDING
<br />MINIMUM 8" BEYOND UNIT PERIMETER. SEE ARCHITECTURAL DRAWING FOR EXACT LOCATIONS.
<br />Shepherd, Harvey & Associates, Inc.
<br />4855 River Green Parkway, Suite 400
<br />Duluth, Georgia 30096-2569 Fla. Cert. of Auth. No. 28961
<br />770-495-4007 FAX 770-495-7112 Project Number: 22-170
<br />z
<br />O
<br />v)
<br />z
<br />Q
<br />a'
<br />N
<br />I-
<br />z
<br />(V
<br />w
<br />�
<br />L-0
<br />M
<br />U)
<br />V
<br />CO
<br />z
<br />U_
<br />J
<br />Q
<br />o0
<br />U
<br />Q
<br />F
<br />J
<br />C r_
<br />Q
<br />U)
<br />W
<br />=
<br />W
<br />_
<br />_
<br />CO
<br />N
<br />M
<br />I
<br />M
<br />W
<br />N
<br />DRAWN BY:
<br />KB
<br />rOJDATIE.: 10/11 /2022
<br />ECT N0.2022.12
<br />REVISIONS
<br />REV.
<br />REV.
<br />REV.
<br />Sheet No.
<br />M-00 1
<br />
|