Laserfiche WebLink
z <br />Q <br />C� <br />D <br />Cn <br />G <br />I <br />0 <br />N <br />N <br />N <br />0 <br />N <br />EL.EGTRIGAL 5 EGIFIGATION5 <br />I. MATERIALS FURNISHED SHALL BE NEW. MATERIALS SHALL BE A MANUFACTURER'S <br />STANDARD AND ESTABLISHED PRODUCT LINE, AND SHALL BE L15TED AND LABELED <br />FOR THE APPLICATION BY UNDERhRITERS LABORATORIES (UL), OR SHALL BE <br />CERTIFIED BY OTHER APPROVED LABORATORY OR BY THE BUILDIN6 OFFICIAL <br />HAVING JURISDIGTIOK <br />2. THE PLANS AC.C.OMPANYIN6 THESE SPECIFICATIONS ARE 6ENERALLY DIAGRAMMATIC <br />AND DO NOT SHOW ALL DETAILS REQUIRED FOR THE COMPLETE WORK. ESTABLISH <br />DETAILS OF THE WORK AS NECESSARY TO PROVIDE FOR THE COMPLETE <br />INSTALLATION OF SYSTEMS AND MATERIALS. ARRAN6E THE WORK 50 AS TO AVOID <br />INTERFERENCE WITH OTHER BUILDIN6 COMPONENTS OR SYSTEMS AS ACTUALLY <br />INSTALLED. <br />3. COMPLY WITH APPLICABLE OR NECESSARY JOB SAFETY PROVISIONS. <br />4. PROVIDE FOR SYSTEM RAuCEMAYS, OUTLET BOXES, PULL "WIRES" OR "CORDS", OUTLET <br />BOX OPENIN65, BOX EXTENSIONS, DEDICATED RECEPTACLES, BAGKBOARDS, ETC. AS <br />SPECIFIED AND INDICATED. TELEPHONE GABLE SHALL BE FURNISHED AND INSTALLED <br />BY OTHERS. <br />5. ELECTRICAL SYSTEMS, EQUIPMENT, AND SUPPORTIN6 STRIIGTURES SHALL BE <br />COMPLETELY AND EFFECTIVELY GROUNDED. BONDIN6 J141EIPS SHALL. BE PROVIDED <br />WHERE NECESSARY. METAL ELECTRICAL RACEWAYS AND FITTIN65, JOINT5 AND <br />CONrECTION5 AT EQUIPMENT SHALL BE MECHANICALLY AND ELEGTRIGALLY SECURED <br />TO PROVIDE AN APPROVED EQUIR-IIENT OR ENCLOSURE 6ROUNDIN65 MEANS, EVEN WHEN <br />NO OTHER SEPARATE 6ROUNDIN6zP MEANS ARE ALSO PROVIDED EITHER INHERENTLY OR <br />BY BONDIN6. <br />b. WERE 6R1E:N 6ROUNDIN67 CONDUCTORS ARE NOT INDICATED SPECIFICALLY FOR <br />EACH BRANCH CIRCUIT BY THE DRANN65, PROVIDE FOR EACH RACEWAY A GREEN #12 <br />6ROUNDIN6 CONDUCTOR IN ADDITION TO BRANCH CIRCUIT CONDUCTORS INDICATED. <br />1. L NLE55 OTHERWISE INDICATED OR DIRECTED BY THE ARCHITECT FOR SPECIAL <br />APPLICATIONS, NRIN6 DEVICES SHALL BE INSTALLED WITH CENTER -OF -BOX MOUNTING <br />HEIGHTS ABOVE FINISHED FLOORS BETWEEN 18-INC E5 AND 44-INGHE5, AS REQUIRED <br />BY HANDICAPPED CODES. MOUNTING HE16HT5 FOR 5PEGIFIG DEVICES SHALL BE AS <br />SGHEDUL.ED BY THE PLANS. <br />8. ELECTRICAL CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: <br />EQUIPMENT 6ROUND: 6REFN. <br />PHASE CONDUCTORS: RED, BLUE, BLACK, <br />NEUTRAL. WHITE; <br />q. NOTIFY THE OWNERS REPRESENTATIVE OF ANY NONFUNGTIONIN6 MATERIAL OR <br />POTENTIALLY UNSAFE CONDITION WITHIN THE PROJECT SYSTEMS THAT 15 OBSERVED <br />DURING THE GONDUGT OF THE WORK. <br />10. WORK SHALL BE FURNISHED AND INSTALLED A5 A MINIMUM IN ACCORDANCE WITH THE <br />APPLICABLE REGIUIREMIENTS AND RECOMMENDATIONS OF THE LATEST LOCALLY <br />ADOPTED EDITION OF CODES AND STANDARDS OF THE FOLLOWING: <br />1. NATIONAL ELEGTRIGAL CODE 11`EC) - NFPA 10. <br />2. ENER6Y CODE - A%PAE/IE5NA qO.1. <br />3. LIFE SAFETY CODE - NFPA 101. <br />4. OTHER NFPA STANDARDS: CIOA AND qq <br />5. U.L. STANDARDS AND LISTIN6 REQUIREMENTS AND NEMA STANDARDS. <br />6. FEDERAL, STATE, AND LOCAL LAWS, ORDINANCES, CODES, AND RULINGS OF <br />BUILDIN6 OFFICIALS HAVING JURISDICTION IN ZEPHHYRHILL 5, FL. <br />11. THE WORK COVERED BY THIS SPECIFICATION SHALL INCLUDE PROVIDIN6 <br />SUPERVI510N, LABOR, SUPPLIES, MATERIALS (TO INCLUDE EQUIPMENT), TOOLS, <br />%RVICE5, DOCUMENTATION, TESTS 4 DEMONSTRATIONS, CERTIFICATES, AND DOLLAR <br />COSTS REQUIRED TO CONSTRUCT THE COMPLETE SYSTEMS AS SPECIFIED HEREIN AND <br />AS SHOWN BY THE PLANS AND OTHER RELEVANT DOCUMENTS. <br />12. UNLESS OTHERWISE SPECIFICALLY SHOWN OR NOTED BY ELECTRICAL PLANS, PILOT <br />DUTY CONTROL SYSTEMS AND RELATED WIRIN6 FOR MECHANICAL EQUIPMENT SHALL <br />BE PROVIDED UNDER THE MECHANICAL SECTION OF THE SPECIFICATIONS. <br />13. SERVICE EQUIPMENT SHALL BE PROVIDED RATED FOR BUILDING LOADS, INCLUJDIN6 <br />INTERRUPTING RATIN65. SERVICE EQUIPMENT SHALL BE SERVED U51% THE TYPE <br />SERVICE ENTRANCE EQUIPMENT AS INDICATED BY THE PLANS. <br />14. ALL RECEPTACLES SHALL BE 20A, 125V, SPECIFICATION GRADE, MOUNTED 18" AFF <br />UNE55 NOTED OTHERWISE. <br />15. FIRE ALARM HORN/SPEAKER AND STROBE DEVICES SHALL BE MOUNTED 80' AFF <br />UNLESS NOTED OTHERWISE. <br />16. 5WITGHES SHALL AS A MINIMUM BE 'HEAVY-DUTY' RATED, QUICK MAKE AND BREAK, <br />SPECIFICATION 6RADE, SINGLE THIROW DDACE5. <br />11. DISTRIBUTION EQUIPMENT U51% CIRCUIT BREAKER TYPE PROTECTIVE DEVICES SHALL <br />USE BOLTED -ON OR SQUARE D' I -LINE DEVICES. <br />18. DISTRIBUTION EQUIPMENT SHALL BE AS INDICATED AND A5 MANUFACTURED BY <br />GENERAL. ELEGTRIG, GUTLER/HAMMER, SQUARE-D, SIEMENS. <br />Iq. PAN U30ARD MAINS SHALL BE COPPER OR AL WITH BRANCH DEVICE <br />CONNECTIONS ARRAN6ED IN A VERTICALLY DISTRIBUTED GONSEGUTIVE PHASE <br />SEQUENCE SUCH THAT ONE OR MULTIPLE POLE BREAKERS CAN BE MOUNTED IN ANY <br />P05IT10K A SOLID NEUTRAL BUS SHALL BE PROVIDED WITH A FEEDER LU6 AND WITH <br />A SEPARATE SET -SCREW TERMINAL FOR EACH BRANCH GIRCIJIT POLE. <br />20. STARTERS AND DISCONNECT SNTCHE5 SHALL HAVE QUICK -MAKE AND <br />QUICK -BREAK MEGHANISMS, AND BE FULLY LY ENCLOSED. <br />21. FIXTURE SUPPORTS AND HARDWARE SHALL BE SUITABLE METAL LHLE55 <br />OTHERWISE INDICATED. SUPPORT STUDS USED FOR INDOOR FIXTURE OR <br />COMPONENT SUPPORT SHALL BE GALVANIZED STEEL OR MALLEABLE IRON; DIEGAST <br />STUDS SHALL NOT BE USED. PROVIDE SEISMIC RESTRAINTS ON ALL FIXTURES PER <br />LOCAL REQUIREMENT5. <br />22. LAMPS SHALL BE MANUFACTURED BY 6ENERAL ELEGTRIG, PHILIPS, OR <br />05RAM/SYLVANIA. <br />23. 6ONDUGTOR5 SHALL BE OF SOFT DRAWN, ANNEALED COPPER HAVING A <br />CONDUCTIVITY OF NOT LE55 THAN 48 PERCENT BY 'ASTM' STANDARDS. <br />24. UNLESS OTHERWISE REQUIRED 13Y CODE OR INDICATED. <br />A. CONDUCTORS NO. 12 AN& AND NO. 10 A 16 SIZE SMALL BE SOLID. <br />B. CONDUCTORS NO.8 A116 SIZE AND LARGER SHALL BE STRANDED. <br />25. R1610 STEEL AND IMG STEEL. CONDUIT, WHEN USED, SHALL BE HOT DIP 6ALVANIZED. <br />STEEL EMT, WHEN USED, SHALL BE HOT DIP 6ALVANIZED OUTSIDE, AND ENAMEL OR <br />6ALVANIZED FINISHED INSIDE. <br />26. EMT COLIPLIN65 AND CONNECTORS SHALL BE METAL AND 5ET-5GREW TYPE. <br />21. UNLESS OTHERWISE INDICATED, WIRING DEVIGE5 SHALL BE. <br />I. SWTCHES: HIJBBEL 1221 OR EQUAL. <br />2. RECEPTACLES: HIBBELL 20A HOSPITAL GRADE. <br />3. COLOR AS SELECTED BY OWNER <br />28. THE TELEPHONE AND SOUND SYSTEMS SHALL INCLUDE BACKBOARDS, RACEHAY5, OUTLET <br />BOXES, PULL CORDS IN EMPTY RACEWAYS, COVER PLATES, AND MISCELLANEOUS <br />MATERIALS OR DEVICES FOR TELEPHONE OUTLETS, ETC,. AS REQUIRED. PROVIDE GABLE <br />WHERE INDICATED ON THE DRANN&5. <br />2q. FIRE ALARM SYSTEM - SEE SHEET E-III. <br />30. FIXTURES SHALL BE INSTALLED IN ACCORDANGE WITH UL LISTIN6 RESTRICTIONS AND <br />LOCAL CODES AND ORDINANCES. <br />31. FIXTURES SHALL BE LOCATED IN A MANNER COORDINATED WITH ANY SUSPENDED <br />ACOUSTIC GEILIN6 PATTERN, AND IN ACLORDANGE WITH PATTERNS A5 SHOWN ON THE <br />ARCHITECTURAL DRANN65. <br />32. UNLESS OTHERWISE REQUIRED BY CODE OR FUNCTION OR INDICATED BY THE PLANS, <br />CONDUCTORS FOR POWER AND LI&MN6 BRANCH CIRCUITS SHALL BE #12 AWG MINIMUM. <br />NO SHARE NEUTRAL 15 ALLONED. <br />33. CONDUCTORS SHALL BE CONNECTED BY UL. APPROVED CONNECTORS. BRANCH CIRCUIT <br />WIRIN6 TO SIZE #8 SHALL BE CONNECTED BY CONNECTORS WITH LIVE SPRIN6 TENSION. <br />34. WIRING SHALL BE INSTALLED IN METALLIC RACEWAYS AS ALLOWED AND SIZED PER NEC. <br />35. RACEWAYS AND GABLE SHALL BE RUN CONCEALED, EXCEPT THAT RACEWAYS OB16NEED <br />ONLY FOR SURFAGE MOUNTIN6 AND RACEWAYS AND GABLE IN EQUIPMENT ROOMS SHALL <br />BE RUN EXPOSED, UNLESS OTHERWISE INDICATED. CONGEALED CONDUIT RUN ABOVE THE <br />GEILIN6 LINE SHALL BE SUPPORTED INDEPENDENTLY OF CEILING CONSTRUCTION. WHERE <br />CEILIN65 OF THE LAY -IN TYPE MAY 8E USED, CONDUITS MUST BE INSTALLED H16H ENOU61-I <br />TO PERMIT REMOVAL OF CEILING PANELS OR EQUIPMENT. <br />36. RP:GEWAY OR GABLE, ETC. THAT PENETRATES A FIRE BARRIER, SUCH AS FIRE OR SMOKE <br />RATED SLAB, WALL, CEILING, OR OTHER ELEMENT, SHALL BE INSTALLED WITH MATERIALS <br />AND METHODS APPROVED FOR THE APPLICATION BY LOCAL BUILDIN6 OFFICIALS. THE <br />CONTRACTOR SHALL BE RESPONSIBLE FOR IDENTIFYING EACH FIRE BARRIER FROM THE <br />ARCHITECTURAL PLANS, AND FOR SEGURIN6 APPROVAL OF MATERIALS AND MIETHOD5 TO <br />BE USED FOR EACH TYPE PENETRATION. <br />31. MLE55 OTHERWISE INDICATED, RAGEWAY5 SHALL BE AS FOLLOWS: <br />I. CONGEALED INSIDE WHERE NOT IN WET OR DAMP LOCATIONS AND NOT EXPOSED <br />TO MECHANICAL INJURY, AND USED FOR 12OV/20A BRANCH CIRCUITS: <br />ELECTRICAL METALLIC, TUBING (i:Mf) OR GABLE THAT 15 L15TED IN NEC, 250.118 A5 AN <br />ACCEPTABLE 6ROUNDIN6 RETURN PATH, SUCH AS TYPE AG/MG. <br />2. THROU61-1 TWO-HOUR RATED FIRE BARRIERS OR BUILDIN6 EXTERIORS: <br />6ALVANIZED M610 STEEL (61RS) CONDUIT MADE UP WATER T16HT. <br />3. FINAL CONNECTION RACEWAYS IN DRY LOCATIONS SERVING 1-1614TIN6 FIXTURES, <br />OR OTHER NON -MOTOR EQUIPMENT LIKELY TO REQUIRE MOVEMENT FOR <br />ADJUSTMENT OR LIKELY To TRANSMIT SHOCK OR V113RATION INTO THE RACEWAY <br />SYSTEM, BUT NOT REQUIRING FLEXIBILITY FOR OPERATION, AND WHERE <br />APPROVED FOR THE APPLICATION SHALL BE FLEXIBLE METALLIC, TUBING (FLEX) <br />WHERE APPROVED FOR THE APPLICATION. <br />38. BOXES SHALL. NOT BE INSTALLED BACK-TO-BACK AND THRU-WALL TYPE BOXES SHALL <br />NOT BE USED DUE TO TRANSMISSION OF SOUND OR HEAT AND SMOKE. OFFSET TO <br />MAINTAIN FIRE RATING PER UL REQUIREMENTS. <br />341. SUSPENDED CEILIN6 CONSTRUCTION SHALL NOT BE USED TO SUPPORT RAGEWAY5, BOXE5 <br />OR OTHER ITEMS, EXCEPT AS ALLOWED BY CODE, ACCEPTED BY THE EN61NIE K AND <br />ACCEPTED BY THE ARCHITECT IN WRITING FOR THE SPECIFIC ITEMK) TO BE SUPPORTED. <br />40. COVER PLATES FOR FLUSH, DRY, ORDINARY LOCATIONS SHALL BE STANDARD <br />CDW16LRATIOK ONE PIECE, STANDARD SIZE PLATES WITH MATC4IN6 SCREWS, AND <br />HAVING MATERIALS, 5TYLE5, AND FINISHES A5 SELECTED BY ARCHITECT. <br />41. CONDUIT SYSTEM, IF USED, SHALL BE INSTALLED CONGEALED ABOVE GEILIN6, ABOVE <br />LOWEST POINT OF STRUCTURAL STEEL SYSTEM LOWER CHORD FOR HORIZONTAL RUNS. <br />INSTALL PARALLEL OR ICULAR TO STRUCTURAL NENBER6. <br />42. CONFIRM THE FOLLOWING WITH THE OWNER PRIOR TO ROU6H-IN: EXACT LOCATIONS OF <br />RECEPTACLES AND VOICE/DATA/TV OUTLETS; EXACT CONNECTION REQUIREM1EiNT5 OF <br />OWNER -FURNISHED EQUIPMENT. <br />43. CONFIRM THE EXACT LOCATIONS OF REGEPTAGLE5, SWITCHES, VOICVDATA/TV <br />OUTLETS WITH MILLWORK/CASEWORK DETAILS AND ARCHITECTURAL ELEVATIONS. <br />44. PER NEC 410.130(6), FLUORESCENT LUMINARIES THAT CONTAIN DOUBLE -ENDED LAMPS AND <br />BALLASTS THAT CAN BE SERVICED IN PLACE REQUIRE A MEANS TO DISCONNECT <br />SIMULTANEOUSLY ALL CONDUCTORS OF THE BALLAST, INGLUDIN6 THE 6ROUNDED <br />CONDUCTOR. CONFIRM THIS REQUIREMENT 15 MET PRIOR TO ORDERING FIXTURES. <br />45. ANY CONDUIT EXITING FROM THE INTERIOR TO THE EXTERIOR OF THE BUILDIN6 SHALL BE <br />FILLED NTH AN APPROVED MATERIAL TO PREVENT THE CIRCULATION OF WARM AIR TO A <br />COLDER SECTION OF THE RAGI3 AY PER NEC 300.1A. SEAL ALL CONDUITS ENTERING <br />BUILDING TO PREVENT WATER EGRESS. <br />46. WIRING IN PATIENT CARE AREAS SHALL COMPLY WITH NEC, ARTICLE 511.13. PATIENT CARE <br />AREAS ARE TREATMENT FLOOR, PATIENT PREP, PRIVATE TREATMENT, PO HHD AND EXAMS <br />ROOMS. ALL BRANCH GIRCJITS SHALL BE PROVIDED WITH AN EFFECTIVE GROUND -FAULT <br />CURRENT PATH BY INSTALLATION IN A METAL RACEWAY SYSTEM OR GABLE HAVING A <br />METALLIC ARMOR ASSEMBLY. THE A55EMBLY OR RACEWAY SHALL. ITSELF QUALIFY AS <br />AN EQUIR-IIENT 6ROUNDIN6 CONDUCTOR IN ACWFOANGE NTH NEC 250.118. PROVIDE <br />INSULATED COPPER EQUIPMENT 6ROUNDIN6 GONUUGTOR WITHIN OR PART OF THE <br />ASSEMBLY OR RACEWAY AND BOND RECEPTACLES AND ALL NON-GGURRENT CARRYING <br />CONDUCTIVE 5URFAGE5 OR FIXED ELECTRICAL IEGI UIPMENT. 517E 6RO1)NDIN6 CONDUCTOR <br />IN AGGORDANGE WITH TABLE 250.122. WIRING IN PATIENT CARE AREAS INCLUDING <br />LIGHTS SHALL CONSIST OF A WIRING METHOD THAT COMPLIES WITH THE <br />REQUIREMENT5 L15TED ABOVE INCLUDING THE FIXTURE WHIP. ACCEPTABLE WIRING <br />TYPE ARE AC, MG WITH GREEN STRIPE AND LISTED AS H05PITAL 6RADE OR <br />WIRE -IN -CONDUIT. SUBMIT ALL PATIENT CARE WIRING FOR APPROVAL FROM THE <br />ENGINEER PRIOR TO ROU&H-IN. ALL WIRING 15 DEDICATED FROM RECEPTACLE TO <br />PANEL WITH NO SHARED NEUTRALS. <br />ELEGTRIGAL 5YMBOL5 <br />YMBOL <br />DE56RIPTION <br />5YMf3OL <br />DE5GRIPTION <br />5YMBOL <br />DE5GRIPTION <br />HOMERUN TO PANEL, ARROWHEADS INDICATE QUANTITY OF CIRCUITS, <br />NURSE GALL <br />FIRE ALARM <br />` <br />2OA/IP UNLSS OTHERWISE NOTED <br />E <br />HASH MARKS INDICATE QUANTITY OF #12 WIRES IN 1/2" CONDUIT, <br />co- <br />NURSE GALL 5YSTEM DOME L16HT/ BUZZER - SINGLE BULB <br />0- <br />HEAT DETECTOR <br />SHORT = HOT OR SW., LONG = NEUTRAL, LONG W/BEND = GROUND, <br />NURSE GALL SYSTEM EMER6ENGY PULL CORD, 44" AFF <br />0-- <br />DUCT SMOKE DETECTOR, PHOTOELEGTRIG TYPE <br />NO MARKS INDICATES 2#12, 1#126 - 1/2" <br />o- <br />NURSE GALL PUSH BUTTON CORD, 44" AFF <br />® <br />MANUAL PULL STATION (+44" AFF UNO) <br />CONDUIT GONGEALED_IN GEILIN6 OR WALL <br />NURSE GALL SYSTEM MASTER STATION <br />N4 <br />COMBINATION HORN/SPEAKER 4 STROBE L16HT <br />CONDUIT EXPOSED_ _. <br />N4 <br />STROBE L16HT <br />'-� <br />_ <br />CONDUIT IN FLOOR OR BELOW SLAB <br />0D <br />5PRINKLER WATER BELL <br />�1Jlftl� <br />FLEXIBLE CONDUIT <br />s0-- <br />SMOKE DETECTOR, PHOTOELECTRIC TYPE <br />o-` <br />CONDUIT TURNED UP <br />OUTLET MOUNTING <br />VALVE TAMPER SWITCH <br />�- <br />CONDUIT TURNED DOWN <br />® <br />MISCELLANEOUS OUTLET - CEILING MOUNTED <br />o- <br />WATER FLOW 5WITGH <br />MULTIPLE OUTLET ASSEMBLY <br />OO - <br />M15GELLANEOU5 OUTLET - WALL MOUNTED <br />® <br />CARBON MONOXIDE DETECTOR <br />_ <br />CONDUIT SEAL FITTING <br />? <br />MISCELLANEOUS OUTLET - FLOOR BOX MOUNTED <br />`O <br />DISCONNECT SWITCH, VOLTAGE AS REQUIRED, <br />NUMERALS INDICATE: AMP5/POLE5/FU5E5NEATHERPR0OF <br />e-- <br />SIMPLEX RECEPTACLE, 20A (+18" AFF LINO) <br />GIRGUIT BREAKER, VOLTA6E AS REQUIRED, <br />DUPLEX RECEPTACLE 018" AFF UNO) <br />NUMERALS INDICATE:_ AMP5/POLE5MEATHERPR0OF <br />DUPLEX RECEPTACLE 044" AFF CENTER OF BOX LINO) <br />_ <br />® <br />MA61NETIG MOTOR STARTER, VOLTA6E A5 REQUIRED, <br />QUADRUPL.EX REGEPTAGLE 13018" AFF UNO) <br />NUMERALS INDICATE: TYF"IZE <br />®- <br />SPECIAL POWER RECEPTACLE, TYPE AS NOTED <br />5EG11JR112C <br />Lo <br />COMBINATION FUSED 5WITCH / MA6NETIG MOTOR STARTER, <br />DUPLEX RECEPTACLE FLOOR MOUNTED <br />NUMERALS INDICATE: AMPS/POLES/FUSES i TYPE/SIZE <br />01- <br />TELEPHONE OUTLET (+18' AFF Lw) <br />o-- <br />DOOR LOCK ELEGTROMA6NE , FAIL SAFE <br />_ <br />PANELBOARD, FLUSH OR 5URFAGE MTD. RE5PEGTIVELY <br />DATA OUTLET 018" AFF UNO) <br />® <br />PLYWOOD BACKBOARD, 3/4" THICK, 8' H16H, WIDTH AS INDICATED <br />COMBINATION TELEPHONE/DATA OUTLET 018" AFF UNO) <br />® <br />WIREWAY, SIZE AS REQUIRED <br />"A" INDIGATE5 ANAL06 TYPE DEVICE <br />51,185CiRIPT5 APPLIED TO OUTLETS <br />® <br />PULLBOX/JUNCTION BOX, 51ZE AS REQUIRED <br />COMBINATION TELEPHONE/DATA OUTLET FLOOR MOUNTED <br />D <br />"DEDICATED", PROVIDE ENGRAVED COVER PLATE <br />_ <br />MOTOR, NUMERAL INDICATES HORSEPOWER, "F" = 1/8 HP OR LESS <br />EP <br />EXPLOSION PROOF, CLA55 AND DIVISION AS NOTED <br />_ <br />® <br />HfrATER, KW A5 INDICATED <br />ISM <br />61ROUND FAULT INTERRUPTER, FEED THRU TYPE <br />TRANSFORMER <br />MILE <br />H <br />HOSPITAL 6RADE <br />Q-- <br />JUNCTION BOX <br />16 <br />ISOLATED 6ROUND <br />SHIMIM2x <br />TRANSFORMER IN <br />5A <br />SAFETY TYPE, CHILDPROOF <br />S <br />51N6LE POLE SWITCH (+44" AFF UNO) <br />SP <br />SLR6E PROTECTED <br />THREE WAY 5WITGH (+44" AFF UNO) <br />AUDIO /VISUAL <br />U <br />"UPS", PROVIDE EN6RAVED COVER PLATE <br />SL <br />SWITCH W/INDIGATOR LIGHT 044" AFF UNO) <br />_ <br />HP <br />WEATHERPROOF <br />MANUAL MOTOR 5WITGH (+44" AFF UNO) <br />INTERCOM STATION 048" AFF UNO) <br />5D <br />SMOKE DAMPERS <br />_ SD _ <br />DIMMER SWITCH (5YNER6Y ISD BC, 120/211 WH MIO) 044" AFF UNO) <br />JUNCTION BOX <br />5FO <br />SMOKE FIRE DAMIPERS <br />SLy <br />0161TAL 5WITCH (CHELSEA GH_X BM PWH) 044" AFF UNO) <br />TELEVISION JACK <br />+??' <br />MOUNTING HT ABOVE FINISHED FLOOR TO CENTERLINE OF DEVICE <br />S <br />TIMER 5WITGH (SEN50R5161ITGH PTS bO WH) (+44" AFF UNO) <br />S <br />OCCUPANCY SENSOR (SEN50RSWITGH W5X PDT WH) <br />SQS2 <br />2P OCCA PANCY 5EN50R (SENSORSWITCH WSX PDT 2P WH) <br />CEILING OC A PANGY SENSOR (SENSORSWITCH GM PDT q) <br />Shepherd, Harvey & Associates, Inc. <br />4855 River Green Parkway, Suite 400 <br />Duluth, Georgia 30096-2569 Fla. Cert. of Auth. No. 28961 <br />770-495-4007 FAX 770-495-7112 Project Number: 22-170 <br />cc <br />(n <br />Y <br />c <br />t- <br />A <br />o <br />O <br />4- <br />•r4 <br />3 <br />H <br />4-+ <br />L <br />•.-1 <br />a <br />Z <br />O <br />U <br />co <br />a <br />-4 <br />0 <br />(q <br />OL <br />o <br />c <br />x <br />^ <br />H <br />N <br />LL <br />U <br />r- <br />C <br />a) <br />L <br />C <br />L <br />H <br />o <br />0 <br />U <br />� <br />� <br />U <br />C <br />C <br />C U <br />Q� <br />.E Q <br />M <br />L cc <br />Q a <br />M <br />cr) <br />C <br />Cl)Q <br />Q <br />z 00 <br />cc <br />O W <br />o <br />w 00 <br />0 <br />� <br />CD <br />Q c <br />m <br />X U <br />O <br />Z - <br />CM <br />N <br />Q N <br />=)hO <br />m <br />Q ... <br />LL <br />Z <br />0 <br />v� <br />Z <br />Q <br />N <br />W <br />m <br />Z <br />0 <br />Lf) <br />� <br />U <br />CM <br />U) <br />z <br />> <br />LL <br />J <br />Q <br />(n <br />Q <br />M <br />J <br />Q <br />` <br />z <br />= <br />Q <br />U) <br />J <br />Q <br />W <br />>- <br />J <br />rn <br />T <br />CL <br />W <br />N <br />� <br />M <br />Z <br />W <br />N <br />'`,���nuurrrrrr��� <br />0 R. zz. <br />xw <br />S. <br />No, 93336 <br />STATE OF <br />%FSS10N 1\\- <br />101 <br />101 <br />RAWN BY: <br />SPJ <br />DATE: 10/ 11 /2022 <br />ROJECT NO.2022.12 <br />REV. <br />REV. <br />REV. <br />REVISIONS <br />Sheet No. <br />E-001 <br />