My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36819 Eiland Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
36819 Eiland Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 4:12:42 PM
Creation date
2/18/2025 3:13:44 PM
Metadata
Fields
Template:
Building Plans
Street #
36819
Location
Eiland Blvd
Contractor
Alex Roush Architects Inc
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
V) <br />LL1 <br />Z <br />O <br />D <br />z <br />Q <br />Cn <br />C� <br />T_ <br />N <br />N <br />N <br />O <br />N <br />00 <br />O <br />T_ <br />m <br />N <br />N <br />O <br />N <br />MECHANICAL EQUIPMENT SCHEDULE <br />UNIT <br />NUMBER <br />UNIT <br />DESCRIPTION <br />ELEC. CHARACTERISTICS <br />IPANEL/CIRCUITj <br />I DESIGNATION <br />CIRCUIT <br />I DESCRIPTION <br />DISCONNECT <br />I SW ITCH <br />NOTES <br />KW <br />I HP <br />I FLA <br />I V I <br />PH <br />AHU-9 <br />AIR HANDLER <br />RELOCATE EXISTING CIRCUIT AND CONDUITS, EXTEND OR REPLACE IF REQUIRED. <br />AHU-10 <br />AIR HANDLER <br />0.1 <br />208 <br />1 <br />PANEL "M" <br />2#12.1 #12G - 3/4"C <br />30/2/1 /20AF <br />AHU-11 <br />AIR HANDLER <br />0.1 <br />208 <br />1 <br />PANEL "M" <br />2#12,1 #12G - 54'C <br />30/2/1 /20AF <br />HP-10 <br />HEAT PUMP <br />20.0 <br />208 <br />1 <br />PANEL "M" <br />2#8,1#1OG -3/4"C <br />60/2/3R/35AF <br />HP-11 <br />HEAT PUMP <br />20.0 <br />208 <br />1 <br />PANEL "M" <br />2#A1 #1 OG - 3/4'C <br />00/2/3R/35AF <br />I � FLOOR PLAN -POWER <br />E-III SGALE:I/8" = I'-O" <br />16ENERAL NOTES: <br />OTEG: (APPLY TO SHEET E-111 ONLY) I <br />I. ALL WIRING DEVICE COVERPLATES IN TREATMENT ROOMS SHALL BE WHITE. <br />2. WIRIN6 IN PATIENT CARE AREAS SHALL. COMPLY WITH NEC, 51-1.13A 4 B. SEE <br />ELECTRICAL SPECIFIGATION #46 ON SHEET E-001 FOR WIRING TYPE. PATIENT CARE <br />AREAS ARE TREATMENT FLOOR, PRIVATE TREATMENT, PD-HHD AND EXAMS ROOMS. <br />3, ALL ELECTRICAL DEVICES NOT SHOH N ARE EXI5TIN6 TO REMAIN UNLE55 NOTED <br />OTHERWISE. <br />4. SHADED DEVICES, DEVICES NOT SHONN AND DEVICES WITH 'E' DE516NATION ARE <br />EXI5TIN6 TO REMAIN. <br />5. ELECTRICAL DEVICES WITH R' DE516NATION ARE EXISTIN6 TO BE RELOCATED AS <br />INDICATED. RECONNECT TO EXISTING GIRCUIT AND CONTROLS MLE55 INDICATED <br />A5 NEW. <br />6. CONNECT MECHANICAL EQUIPMENT PER MECHANIGAL EQUIPMENT SCHEDULE ON SHEET <br />E-101 TOP LEFT. REFERENCE MECHANICAL DRAWIN6 M-101 FOR EXACT LOCATIONS. <br />PROVIDE EQUIPMENT NAME ON DISCONNECT MEANS. <br />-7. ALL RECEPTACLES IN TCU EXAM SHALL BE 6FCI AND HOSPITAL 6RADE (5-20R). <br />8. DEVICES WITH 'D' DE516NATION SHALL BE 6RAY IN COLOR WITH A GRAY TAMPER <br />PROOF GOVERPLATE. <br />q. WIRING IN PATIENT CARE AREAS SHALL C.OMPL.Y WITH NEC. ARTICLE 517.13. PATIENT <br />CARE AREAS ARE TREATMENT FLOOR, PATIENT PREP, PRIVATE TREATMENT, PD-HHD <br />AND EXAMS ROOMS. ALL BRANCH CIRCUITS SHALL BE PROVIDED WITH AN EFFECTIVE <br />GROUND -FAULT CURRENT PATH BY INSTALLATION IN A METAL RACEWAY SYSTEM OR <br />GABLE HAVING A METALLIC ARMOR ASSEMBLY. THE A55EMBL-Y OR RACEWAY SHALL <br />ITSELF QUALIFY AS AN EQUIPMENT 6ROUNDIN6 CONDUCTOR IN ACCORDANCE WITH <br />NEC 250.116. PROVIDE INSULATED COPPER EQUIPMENT 6ROU10IN6 CONDUCTOR WITHIN <br />OR PART OF THE A55EMMY OR RACEWAY AND BOND RECEPTACLES AND ALL <br />NON-U GARRYIN6 GONDl1GTIVE SURFACES OR FIXED ELECTRICAL EQUIPMENT. <br />SIZE 6ROUNDIN6 CONDUCTOR IN ACCORDANCE WITH TABLE 250.122. WIRING IN <br />PATIENT CARE AREAS INCLUDING L16HT5 SHALL CONSIST OF A WIRINS METHOD <br />THAT COMPLIES WITH THE REQUIREMENTS LISTED ABOVE INCLUDIN6 THE FIXTURE <br />WHIP. ACCEPTABLE WIRING TYPES ARE AC, MG WITH 6REEN STRIPE AND LISTED <br />A5 HOSPITAL GRADE OR WIRE -IN -CONDUIT. SUBMIT ALL PATIENT CARE WIRIN6 <br />FOR APPROVAL FROM THE ENGINEER PRIM TO ROU6H-IN. ALL WIRING 15 <br />DEDICATED FROM RECEPTACLE TO PANEL WITH NO SHARED NEUTRAL-5. <br />10. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT MOUNTING LOCATION OF <br />RECEPTACLES IN TREATMENT FLOOR, BIOMED AND TCU AREAS AT SUPPLY BOXES. <br />II. RECEPTACLES LOCATED ON FIRE WALL SHALL HAVE FIRE RATED PUTTY PADS. <br />INSTALL ALL ELECTRICAL DEVICES ABOVE PLUMBIN6 IN RD. CHASES. SEE <br />ARC.HITEGTURAL DETAIL. <br />12. NO 15A,120V RECEPTACLES ARE ACCEPTABLE. <br />13. PROVIDE TYPED LABEL. CIRCUIT DM16NA7ION ON CO A34"TES FOR ALL <br />RECEPTACLES. <br />14. PROVIDE TAMPER RE515TANT RECEPTACLE IN BUSINESS OFFICES, CORRIDORS, WAITING <br />ROOMS PER NEC, 406.12(5). <br />KEYED NOTES: <br />OTES: (APPLY TO SHEET E-III ONLY) <br />O PROVIDE TV RECEPTACLE. COORDINATE EXACT LOCATION WITH ARCH MILLWORK 4 <br />OVER. COORDINATE MOUNTING HEIGHT IN FIELD SO THAT RECEPTACLE 15 NOT <br />VISIBLE. <br />20 PROVIDE UNDER_%AB 3/4' CONDUITS TO NEAREST WALL. <br />O MOUNT RECEPTACLE 6" BELOW COUNTER TOP. COORDINATE FINAL LOCATIONS WITH <br />OWNER PRIOR TO ROUGH -IN. <br />® MOUNT RECEPTACLES AT 48" A.F.F. <br />O EACH PATIENT STATION SHALL BE PROVIDED WITH: (1) DEDICATED HOSPITAL 6RADE 6FI <br />RECEPTACLE (D-DE5I6NATIOIW, (I) HOSPITAL GRADE 6FI QUAD RECEPTACLE BETHEEN <br />CHAIRS (6E NERAL PURPOSE.); 0) .60X WITH COVER PLATE AND I" G. STUBBED UP INTO <br />GEILIN6 - COORDINATE EXACT LOCATION OF DEVICES WITH GA554IORK SUPPLIER PRIOR <br />TO INSTALLATION. <br />© RELOCATE EXISTIN6 M4CTION BOX FOR 14UR5E GALL SYSTEM. CONNECT PER <br />MANUFACTURERS RECOMMENDATION. <br />O PROVIDE AND INSTALL A 125" CONDUIT KIFULLSTRIN6 FROM TREATMENT FLOOR TO RO <br />ROOM FOR HATER QUALITY MONITOR COORDINATE EXACT LOCATIONS AT TREATMENT <br />FLOOR AND RD. ROOM WITH RD. EQUIPMENT VENDOR/CONTRACTOR. <br />® RELOCATE EXISTING PaAR FOR SECURITY MONITOR RECONNECT TO EXI5TIN6 CIRCUIT. <br />q0 PROVIDE AND INSTALL A LE6RAND RFB4 COMBINATION POVEMATA FLOOR BOX <br />WITH #RFB-DR AND *DT5-2-2AB BRACKETS AND #FPGTGB5 CUTOUT COVER <br />ASSEMBLY. <br />Shepherd, Harvey & Associates, Inc. <br />4855 River Green Parkway, Suite 400 <br />Duluth, Georgia 30096-2569 Fla. Cert. of Auth. No. 28961 <br />770-495-4007 FAX 770-495-7112 Project Number: 22-170 <br />Rf (A Y <br />C L <br />4— 3 <br />L rl >1 <br />Z 0 <br />O U C <br />C r•1 <br />fn C i-J <br />/Y■ •r•I l� 7 <br />Lim U <br />O L (p ^ O C <br />X <br />LL U O 0) <br />cC M N <br />L C L <br />C E 4- <br />O H O <br />U <br />U <br />O <br />Q M <br />i0 <br />Q co <br />a <br />a <br />Q CD CD <br />J O O N N <br />Oit M <br />w <br />n z Q M m <br />X U C Z M 0 <br />0 --I Q O _N <br />N O H- t` <br />z <br />O <br />U) <br />Z <br />Q N <br />C- H N <br />It <br />w Z Ln <br />� <br />� M U <br />Cn z > � <br />J Q 00 u� <br />Q � C)J <br />C) > z = <br />Q <br />J <br />IL <br />W <br />= CV) <br />N <br />Z <br />LU <br />N <br />���'RD R. <br />NO. 93 36 <br />S. • 1a6r - <br />ATE <br />ION /zz <br />DRAWN BY: <br />SPJ <br />DATE: 10/ 11 /2022 <br />PROJECT NO.2022.12 <br />REVISIONS <br />REV. <br />REV. <br />REV. <br />Sheet No. <br />E-1 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.