Laserfiche WebLink
1.I. "I -1� _'—{'I^=1' <br />N <br />N <br />0 <br />N <br />00 <br />0 <br />7— <br />w <br />_1; <br />2 DEMOLITION FLOOR PLAN <br />- I 0 pia° <br />LEGEND <br />°X15TING NON -RATED PARTITION <br />NEW NON -RATED PARTITION <br />TOP OF WALL 42" AFF. (UNLE55 NOTED OTHERWISE) <br />W/ FRP ALL SURFACES (G" FRAMING AT WALL HUNG LAV5.) AND P, LAM <br />WALL CAP5. <br />EXISTING ONE HOUR FIRE RATED TENANT DEM151NG BARRIER. <br />4A:80B:C, WALL HUNG FIRE EXTINGUI5HER; PROVIDE 5EMI-RECE55ED FIRE <br />MEM F.E. F.E, EXTINGUISHER CABINETS WITH FLU51­I HANDLES IN PATIENT AREAS. MOUNT 50 NOZZLE 15 <br />42" AFF. PROVIDE 5URFACE MOUNTED FIRE EXTINGUI5HER5 IN THE 15ACK-OF-HOU5E <br />AREAS. MOUNT BRACKET AT 42" AFF. <br />NOT IN 5COPE OF WORK. <br />J <br />NOTE: <br />PROVIDE 50UND BATT IN5ULATION AT ALL WALL5 OF LOUNGE, CONFERENCE ROOM. <br />GENERAL DE1" 0L.I7ION NOTES <br />I . WHEREVER WALL DEMO 15 CALLED FOR REMOVE COMPLETELY ALL COMPONENTS. <br />LE„ PLUMBING, ELEC„ AND/OR MECH, <br />2. CAP -OFF AND 5EAL ALL PENETRATION5 FROM DEMOLISHED PLUMBING, ELEC., AND <br />MECH. WORK. <br />3. DEMOLISH It REMOVE ALL 5U5PENDED CEILING COMPONENT5. <br />4. REMOVE ALL H.V.A.C., ELECTRICAL * PLUMBING 5Y5TEM5 WITHIN THE TENANT <br />5PACE. <br />5. EX15TING CONC. FLOOR SLAB SHALL BE LEVELED, BROOM CLEAN WITH NO <br />REMAINING ADHE51VE RE5IDUE, AND 5EALED. <br />G. REMOVAL OF DEMOLITION, AND CON5TRUCTION DEBR15 5HALL BE COORDINATED <br />BETWEEN THE GEN. CONTRACTOR, THE CENTER MANAGEMENT AND ALL APPLICABLE <br />LOCAL CODE5 AND ORDINANCE5. <br />7. WHEN ABANDONED PLUMBING, OR ELECTRICAL PROTRUDE ABOVE THE FLOOR LEVEL, <br />CUT � CAP 50 PATCHED AREA 15 FLUSH WITH FIN15HED SLAB. <br />8, LEAVE TENANT 5PACE PREPARED FOR NEW INTERIOR FIN15HE5 PER THESE <br />DOCUMENT5. <br />9. CONCRETE DEMOLITION - REQUIREMENT5 FOR PATCHING AND REPAIRING THE EXISTING <br />REINFORCED CONCRETE 5LA5 ON GRADE WHICH HAVE BEEN D15TUR5ED DURING THE UNDER <br />FLOOR MODIFICATIONS. <br />SAW CUTS IN FLOOR IF REQUIRED 5HALL BE CAREFULLY PERFORMED AND THE EXISTING <br />CONCRETE MATERIALS CAREFULLY REMOVED FROM THE TRENCH LOCATIONS. <br />THE SAND OR GRAVEL BED 505TRATE WILL BE REMOVED A5 REQUIRED FOR ANY <br />MODIFICATION5 AND CAREFULLY 5TOCKPILED SUBSTRATE MATERIALS WILL BE PLACED IN <br />THE VOID5 AND RE -COMPACTED IN PLACE WHEN MODIFICATION5 ARE COMPLETE, <br />501L5 PRETREATED FOR TERMITE PROTECTION DURING ORIGINAL BUILDING SHELL <br />CON5TRUCTION WILL NOT BE REQUIRED TO RE -TREAT 501L UNLE55 REQUIRED BYTHE LOCAL <br />GOVERNING AGENCY. <br />DAMP PROOFING MEMBRANE WILL BE PATCHED AND REPAIRED U51NG ,OOG POLYETHYLENE <br />FILM A5 NEEDED TO SEAL THE OPENINGS. <br />VOIDS IN THE CONCRETE FLOOR 5LAB WILL BE FILLED WITH 3000 P51 CONCRETE WITH FIBER <br />ME5H ADMIXTURE. THE CONCRETE FIN15H SHALL MATCH THE EX15TING FINISH. <br />DOOR EIN15H <br />HARDWARE <br />SCHEDULE: <br />ALUMINUM 5TOREFRONT DOORS: <br />G. <br />PROTECTION <br />I . OVERHEAD <br />PLATES - <br />KICK PLATE: ROCKWOOD - K 1050 10" X 2" LDW 45E C5K (PUSH SIDE), U532D <br />DOOR STOP - RIX50N G SERIES (COORD. W/ DOOR WIDTH), G30 <br />ARMOR PLATE: ROCKWOOD - K1050 3G" X 2" LDW 415E C5K (PUSH SIDE), U532D <br />7. <br />DOOR <br />2. AUTOMATIC <br />STOPS- <br />WALL STOP: ROCKWOOD - 409, U532D (APPLY TO ALL DOORS THAT SWING INTO A WALL) <br />OPENER - STANLEY MAGIC -FORCE SWINGING DOOR OPERATOR <br />OVERHEAD DOOR STOP: RIX50N 2 SERIES (COOK. W/ DOOR WIDTH), G52 <br />TYPICAL HARDWARE FOR ALUMINUM STOREFRONT ENTRANCE AND EXIT ONLY <br />8, <br />THRESHOLD - <br />STANDARD: PEMKO - 17 1, AK <br />DOORS U.N.O. REFERENCE REMARKS IN DOOR $ FRAME SCHEDULE. ALL OTHER <br />HEAVY DUTY: PEMKO 2715 W/ PEMKOTE <br />HARDWARE BY ALUMINUM DOOR MANUFACTURER * STANLEY POWER DOORS. <br />9. <br />WEATHER <br />METAL / WOOD DOORS * METAL FRAMES: <br />STRIPS - <br />PEMKO - 2,59 1 APK (TK5P8), A <br />I . HINGES - STANDARD: MCKINNEY - TA27 14, 4.5 X 4.5, NRP, U52GD <br />CONTINUOUS: PEMKO - CFM835LFHD 1, C <br />10. <br />SWEEP - <br />PEMKO - 3452AFK (TK5P8), A <br />1 1. <br />T-ASTRAGAL - <br />PEMKO - 355_P, A <br />2. PLU5H5OLT5 - ROCKWOOD - 555, G2G <br />12. <br />VIEWER - <br />ROCKWOOD - G22 (ACTIVE LEAF), 5TNN <br />3. LOCK5ET5 - KEYPAD LOCK5ET: YALE - B-PB NT5G20-NR, G2G <br />PRIVACY LATCH SET: YALE - PB 4702LN, G2G <br />KEYED LOCK5ET: YALE - B-PB 4707LN, G26 <br />13. <br />DRIP CAP - <br />PEMKO - 34GC, A NOTE: ALL HOLLOW METAL FRAMES SHALL BE WELDED, NO <br />PA55AGE LATCH SET: YALE - PB 4701 LN, G26 <br />EXCEPTIONS. <br />STOREROOM LOCK5ET: YALE - B-PB-R 8840FL CT75D, 626 <br />14. <br />GASKETING - <br />PEMKO - PK33DD <br />, <br />UTILITY LOCK5ET: YALE - B-PB 4705LN, 626 <br />NOTE: APPLY A POLYURETHANE BEAD AT THE BOTTOM AND ALL <br />15. <br />SILENCERS - <br />ROCKWOOD - G08 EDGES OF DOOR PRAME5 - COLOR TO MATCH DOOR FRAME <br />4, TRIM <br />FIN15H COLOR. <br />HARDWARE - EXIT DEVICE (EXIT ONLY): YALE - 7 100 G30, G30 <br />EXIT DEVICE (TEAMMATE ENTRANCE): SARGENT - 1 2-70-KP-8877-ETP, G30 <br />NOTE: CONFIRM HARDWARE SCHEDULE WITH OWNER. ALL <br />EXIT DEVICE (NON -TEAMMATE ENTRANCE): YALE - 7 1 00-3G G32F, G30 <br />OFFICE5 AND ENTRY SHALL BE KEYED ALIKE EXCEPT THE <br />ELECTRIC STRIKE: HE5 - 4500C, G30 <br />FACILITY ADMINISTRATOR'S OFFICE WHICH 15 TO AL50 BE A <br />RECTIFIER: HE5 - 2005M3 SMART PAC III (USED W/ ELECTRIC STRIKE) <br />MASTER KEY. <br />DUST PROOF STRIKE: ROCKWOOD - 570, G2G <br />NOTE: ALL ACCE55 CONTROLLED DOORS SHALL BE FAIL SAFE <br />5. CLOSERS- SURFACE: YALE - 350 1, G89 <br />WHERE THE SYSTEM UNLOCKS AT A L055 OF POWER, <br />SURFACE W/ STOP: YALE - 353 1, G89 <br />ACTIVATIONS OF THE FIRE ALARM, SPRINKLER, OR OTHER FIRE <br />SURFACE W/ HOLD OPEN: YALE - 4420T, G89 <br />DETECTION DEVICE. <br />SURFACE (EXIT ONLY): YALE - UNI-J 4400 48G, G89 <br />NOTE: PROVIDE TACTILE "EXIT" SIGN AT EACH EXTERIOR DOOR <br />MOUNTED 1 5"-40" AFF. SEE LIFE SAFETY NOTE # 19. <br />WALL LEGEND <br />rri.0".1 <br />ANNOTATED FLOOR PLAN <br />- I 0 1 is° = 1 1_01, <br />THE DASHED LINES DENOTE EXISTING WALLS, DOORS <br />AND AREAS TO BE DEMOLI5HED. <br />u � <br />u � <br />THE 50LID LINES DENOTE EXISTING WALLS, DOORS, <br />AND AREAS TO REMAIN INTAGT. <br />DEMOLITION AREA BOUNDARY <br />/ f f NOT IN 5COPE OF WORK <br />L / <br />=NERAL NOTE: <br />ALL EXTERIOR WINDOWS AND DOORS TO RECEIVE I " INSULATED GLAZING <br />4" HEADER ON ALL EXTERIOR HOLLOW METAL FRAME5 <br />kLL HOLLOW METAL FRAMES SHALL BE WELDED <br />_-...................... ..................................................... ............................................................................................. -................................................................................ <br />O T =TEMPERED S <br />GLASS <br />ANNOTATED PLAN <br />KEYNOTES <br />❑A COAT/GOWN HOOK5 - 51NGLE HOOK BRADLEY - <br />914. MOUNT 40"-48" FOR ADA, <br />® 8" TALL GLA55 SPLASH GUARD <br />-5EE MILLWORK DETAIL5. <br />© CEILING MOUNTED T.V. @ EACH 5TATION, <br />PROVIDE AND INSTALL BRACKET W/ BLOCK'G. AT <br />ALL LOCATIONS. <br />R.O.5UPPLY BOXE5 TYP. <br />42" HIGH FRP WALL U.N.O. <br />DOOR AND FRAME SCHEDULE <br />MARK <br />ROOM <br />DOOR <br />FRAME <br />MATL <br />THRESHOLD <br />w <br />o <br />HARDWARE <br />REMARKS <br />SIZE <br />THK <br />MATL <br />TYPE <br />FIRE <br />RATING <br />I <br />WAITING <br />3'-G" x 8'-0" <br />1 3/4" <br />5C WD <br />B <br />HMF <br />YE5 <br />KEYPAD LOCK5ET <br />FAIL SAFE ELECTRIC STRIKE MIRROR GLA55 SURFACE CLOSER <br />2 <br />BUS. OFF. <br />3'-0" x 7'-0" <br />1 3/4" <br />1 5C WD <br />B <br />HMF <br />YE5 <br />KEYPAD LOCK5ET <br />3 <br />3'-0" x 7'-0" <br />1 3/4" <br />5C WD <br />B <br />HMF <br />YE5 <br />PA55AGE LATCH 5ET <br />ARMOR PLATE PU5H SIDES 5URFACE CL05ER W/ 5TOP <br />4 <br />BI MED <br />3'-0" x 7'-0" <br />1 3/4" <br />5C WD <br />B <br />HMF <br />NO <br />PA55AGE LATCH 5ET <br />ARMOR PLATE PUSH SIDES <br />5 <br />RELOC. CONFERENCE <br />3'-0" x 7-0" <br />1 3/4" <br />5C WD <br />B <br />HMF <br />NO <br />PA55AGE LATCH 5ET <br />LOCATE EXISTING CONFERENCE DOOR <br />G <br />LT <br />3'-0" x 7-0" <br />1 3/4" <br />5C WD <br />A <br />HMF <br />I <br />I YE51 <br />5TOREROOM LOCK5ET <br />7 <br />FAG ADMIN. <br />3-0" x 7-0" <br />1 3/4" <br />5C WD <br />B <br />HMF <br />I <br />I NO <br />I KEYED LOCK SET <br />NOTE: CONFIRM HARDWARE SCHEDULE WITH OWNER. PROVIDE MA5TER KEYING 5Y5TEM PER OWNER REQUIREMENT5 <br />NOTE: ALL HOLLOW METAL DOOR FRAMES AND WINDOW FRAME5 TO BE PAINTED PER COLOR FINISH 5CHEDULE. <br />NOTE: PROVIDE TACTILE "EXIT" SIGN AT EACH EXTERIOR DOOR MOUNTED 15"40" AFF. SEE LIFE SAFETY NOTE # 19. <br />NOTE: ALL ACCE55 CONTROLLED DOORS SHALL BE FAIL SAFE WHERE THE 5Y5TEM UNLOCKS AT A L055 OF POWER, <br />ACTIVATION OF THE FIRE ALARM, SPRINKLER, OR OTHER FIRE DETECTION DEVICE. <br />1_ <br />C <br />L <br />1►- <br />3 <br />L <br />•r-I <br />>, <br />O <br />'a <br />C <br />> <br />c <br />m <br />Z <br />0 <br />O <br />� <br />U <br />c <br />C <br />lA <br />C <br />C <br />4j <br />•4 <br />m <br />=3 <br />U <br />L <br />O <br />O <br />C a <br />X <br />x <br />^ <br />4•+ <br />a) <br />L.L <br />U <br />•r•IO <br />m <br />LL_ <br />c: <br />C <br />L <br />C <br />E <br />4- <br />o <br />•1 <br />am <br />U <br />'o <br />-0 <br />,� N) 7w3 vi as lwa e 3 am r ? on Oil <br />th,2 p'iR? <br />diYf?6ryll:{i:i^J :? ?f':m ' CfftiY.'I(?,f. <br />>,rt dl:?w:r thm ropwt✓ of A.EX 51,00 -i, INC. <br />red is eot' t, Ut :,o!>;3tl o: r.p,urw ,,6 lrhola <br />!t !" Tx d;:oc;iy I<d W:3a hwl�: u +d 13 <br />ru^, to ha a�W'l as v!g )thfl, perjr. t. It is to ]r. <br />,m,... and apnn rce{{flexd <br />U <br />U <br />4-1 <br />CID <br />U <br />CO <br />CC <br />M <br />CL <br />Q <br />Q <br />OOC <br />CO <br />J <br />O <br />O <br />t­ <br />N <br />O <br />:D <br />z <br />Q <br />M <br />M <br />X <br />U <br />i-+ <br />F- <br />cM <br />cM <br />Al <br />0 <br />Z <br />— <br />M <br />L0 <br />H <br />J <br />O <br />N <br />m <br />Q <br />~ <br />U- <br />z <br />O <br />V) <br />z <br />X <br />N <br />w <br />C\l <br />M <br />Z <br />M <br />J <br />Q <br />> <br />u- <br />a <br />m <br />u <br />Q <br />> <br />0 <br />J <br />U) <br />Q <br />z <br />= <br />J <br />W <br />2 <br />7- <br />7—W <br />CEO <br />N <br />�-- <br />co <br />W <br />N <br />ia1 Lz <br />DRAWN BY: <br />EM <br />DATE: 10/ 1 1 /2022 <br />PROJECT NO.2022. <br />REVISIONS <br />REV. <br />REV. <br />R EV. <br />Sheet No. <br />A-1 02 <br />