37130 Eiland Blvd (3)
Zephyrhills
>
Building Department
>
Building Plans
>
37130 Eiland Blvd (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 4:16:24 PM
Creation date
2/18/2025 3:13:57 PM
Metadata
Fields
Template:
Building Plans
Street #
37130
Location
Eiland Blvd
Contractor
AEC Services
Building Plans - Permit #
18278
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NON -HAZARDOUS AREA <br />HAZARDOUS AREA <br />GENERAL. NOTES <br />REMOTELY MONITORED VEEDER ROOT EQUIPMENT. <br />CONTRACTOR SHALL PLACE A TYPEWRITTEN SENSOR <br />SCHEDULE THAT INDICATES WHICH CHANNEL IS <br />ASSOCIATED WITH WHICH SENSOR <br />SITE MONITORING WIRING SCHEMATIC <br />1 1 /2"=1'-0" <br />0 <br />0 <br />a <br />0 <br />W <br />Z <br />0 <br />z <br />0 <br />M <br />En <br />En <br />r (% <br />a � <br />00 <br />en <br />WZ <br />�o <br />)UF- JUNL; I IUN bUXt5 7 F'tK <br />11A11 <br />Probe <br />11 B 11 <br />Non-Disciminating <br />Sump Sensor <br />(Containment) <br />=R CABLE JACKET <br />TO <br />MONITOR <br />SEALANT <br />PACK <br />UTS <br />is <br />POS <br />RJ45 CATEGORY <br />PATCH 5CABLE <br />CORD <br />ROUTER HUB <br />\ TO FRAME RELAY <br />TELEPHONE LINE <br />ISP CABLE WITH KIT <br />ADAPTER #330020-409 <br />NOTE: <br />ISP <br />ATG <br />TS-1000 <br />CABLE <br />BOX <br />PASSPORT <br />GAS <br />CONTROLLER <br />1. HUB, ROUTER AND CABLES BY NCR INSTALLER <br />2. PASSPORT GAS CONTROLLER, D-BOX, CRIND CONTROL CABLE, <br />GAS CONTROLLER CABLE AND D-BOX CABLE INSTALLED BY THE <br />GILBARCO AUTHORIZED SERVICE CONTRACTOR <br />D-BOX <br />"Y" CABLE & 2 9-PIN "D" <br />STYLE CONNECTORS <br />POS GAS CONTROLLER DIAGRAM <br />N TS <br />DUPLEX RECEPTACLE <br />-7R�rk <br />,TA <br />PAIRED GASOLINE <br />CABLE IN TRENCH TO <br />GASOLINE DISPENSERS <br />GASOLINE DISPENSER <br />DATA DISCONNECT <br />DEVICE <br />IMPORTANT: THIS IS A CONTROL <br />REFLECT THE ACTUAL LOCATIONS s <br />OF CONDUIT ENTRY (SEE NOTE 7 <br />U <br />BELOW). 0 <br />0 <br />VEEDER-ROOT REQUIRES THAT ANYONE INSTALLING OUR <br />EQUIPMENT MUST BE LEVEL I CERTIFIED. FOR MORE <br />INFORMATION REGARDING THE HOME STUDY INSTALLERS <br />COURSE CONTACT JOHN HOWELL 951-532-8599. <br />WARNING: IN INSTALLATION AND USE OF THIS <br />p <br />PRODUCT, COMPLY WITH THE NATIONAL <br />ELECTRICAL CODE; FEDERAL, STATE AND LOCAL <br />it <br />CODES. IN ADDITION, TURN OFF POWER AND TAKE <br />OTHER NECESSARY PRECAUTIONS DURING <br />> <br />N <br />INSTALLATION, SERVICE AND REPAIR TO PREVENT <br />Proto 2nd Qtr 04-03-15 <br />PERSONAL INJURY, PROPERTY LOSS AND <br />EQUIPMENT DAMAGE. <br />WARNING: DISCONNECT ALL POWER BEFORE <br />MAKING ANY CONNECTIONS TO PREVENT DEATH, <br />SERIOUS INJURY, EXPLOSION, OR ELECTRICAL <br />SHOCK. MONITOR MUST NEVER BE OPERATED <br />UNLESS THE FRONT COVER IS CLOSED OVER THE <br />BARRIER TERMINALS IN THE INTRINSICALLY SAFE <br />AREA. <br />Uc <br />JM <br />z <br />W <br />' 1. INTRINSICALLY SAFE WIRING <br />J J <br />CNI <br />BONDED CONDUIT MEANS THAT THE METALLIC <br />M LO <br />SECTIONS OF CONDUIT ARE PERMANENTLY <br />Q <br />j <br />JOINED TO FORM AN ELECTRICALLY <br />CONDUCTIVE PATH THAT WILL ASSURE <br />a- <br />O <br />m J <br />LL <br />LL1 <br />Q <br />ELECTRICAL CONTINUITY, AND THAT THE <br />H <br />Z 07 <br />(' <br />CONDUIT HAS THE CAPACITY TO CONDUCT <br />SAFELY, ANY CURRENT LIKELY TO BE IMPOSED. <br />Ld <br />�-/ <br />Z J <br />z_ <br />Q <br />Q W = <br />CCQ <br />a) BONDED & NON -BONDED CONDUIT - THE <br />1: <br />0 <br />0 <br />WIRES BETWEEN THE MONITOR AND EACH <br />Z <br />Q M 0 <br />� <br />PROBE/SENSOR LOCATION MUST BE #14, #16 OR <br />O) <br />rl- <br />#18 AWG STRANDED COPPER WIRES <br />F- <br />M W <br />WITHIN A SHIELDED CABLE. SHIELDED CABLE <br />N <br />MUST BE RATED AT LESS THAN 100 <br />W <br />W <br />PICOFARAD PER FOOT AND MUST BE <br />N <br />MANUFACTURED WITH A MATERIAL SUITABLE <br />rM <br />M <br />FOR THE ENVIRONMENT, SUCH AS BELDEN <br />88760. <br />2. CONNECT THE BARRIER GROUND TO THE <br />EARTH GROUND BUS AT THE POWER <br />DISTRIBUTION PANEL WITH #12 AWG (OR <br />LARGER) CONDUCTOR. <br />3.O DENOTES FIELD WIRING CONNECTION USING <br />WATERPROOF CONNECTORS SUPPLIED WITH <br />THE PROBE(S) AND SENSOR(S). <br />4. INTRINSICALLY SAFE WIRING SHALL BE <br />INSTALLED IN ACCORDANCE WITH ARTICLE <br />504-20 OF THE NEC, ANSI/NFPA 70. <br />5. TO MAINTAIN INTRINSIC SAFETY, <br />PROBE/SENSOR WIRING MUST BE INSTALLED <br />WITH EITHER SEALED CONDUIT OR DIRECT <br />BURIAL METHODS. REFER TO "DIRECT <br />BURIAL CABLE INSTALLATION', MANUAL NO. <br />576013-858. <br />6. ELECTRICAL RATING POWER INPUT 120 VAC, <br />50/60 HZ, 100 VA MAXIMUM. <br />7. THIS DOCUMENT IS NOT TO BE USED AS A <br />SUBSTITUTE FOR SPECIFIC EQUIPMENT <br />INSTALLATION MANUALS. FOR INSTALLATION <br />DETAILS USE THE RESPECTIVE MANUAL: <br />TLS-350(R) 576013-879 <br />8. ALL CABINET PENETRATIONS MUST ENTER <br />THROUGH A PRE -DRILLED CONDUIT <br />KNOCKOUT. <br />o <br />I— <br />U <br />N <br />o <br />O <br />00 <br />Z <br />M <br />CO <br />to <br />N <br />Q <br />m <br />W <br />m <br />N <br />s <br />0 <br />V <br />oa�iccac`o=°°omcHE <br />(rnZ>>-6�vsV4).ao0E <br />>,N Uo _ C: 0 0 0 0,04- <br />•°.00-'o3oc'v=0-00 <br />$ o v C �. v rn = taL N N <br />02MM3ca =—o <br />mm <br />aCN'~c�c.3N3t>>v�i <br />v,00NQ° E <br />E N Ott Nt O u!(n Ot n U <br />U(�6� CO�,2e(a0a <br />m::,) co.0>>,w° <br />o(nca°3o°40oWc;a <br />0 ow c-- °UY 3'_cl) <br />%0, <br />FER ry' <br />E NSF•' <br />N 67 3 <br />Lt <br />ST TE <br />e• �`b <br />ON AL11811111111101 �?_,, u <br />SHEET: <br />G12 <br />FUELING - USA <br />