Laserfiche WebLink
GENERAL NOTES AND SPECIFICATIONS <br />1. Unless otherwise noted on the plans, all construction <br />methods, workmanship, materials and testing shall conform to <br />the "Florida Department of Transportation (FDOT)'s "Standard <br />Specification for Road and Bridge Construction", its current <br />supplements and standard index drawings, and any city, <br />COUNTY, or any other agency's rules and regulations. <br />2. Survey layout and testing shall be by the Contractor. <br />3. All work within the right-of-way shall be coordinated <br />with the CITY, County, and/or FDOT. All disturbed areas <br />within the right-of-way shall be restored to the <br />original condition or better in accordance with <br />county, and/or FDOT standards. <br />4. Locations, elevations and dimensions of existing <br />utilities, structures, and other features are shown <br />according to the best information available at the time <br />of preparation of these plans. The contractor shall <br />verify the locations, elevations and dimensions of <br />existing utilities, structures and other features <br />affecting this work prior to construction. <br />5. The contractor shall use extreme caution in areas of <br />buried utilities and shall provide at least 48 hours <br />notice to the utility companies prior to construction <br />to obtain field locations of existing underground <br />utilities. The contractor shall protect and maintain <br />operation of existing utilities during construction. <br />6. The contractor shall check plans for conflicts and <br />discrepancies prior to construction. The contractor <br />shall notify the engineer of any conflicts before <br />performing any work in the affected area. <br />7. The Engineer shall be notified as to where existing <br />utility services interfere with the proposed construction. <br />8. The Contractor is responsible for repairing any damage <br />to existing facilities, above or below ground, that may <br />occur as a result of the work performed by the contractor. <br />9. All underground utilities must be in place and tested <br />or inspected prior to base and surface construction. <br />10. Utilities installation shall conform to the requirements <br />of the applicable federal, state and local regulations <br />including but not limited to the Florida Department of <br />Environmental Protection (FDEP), Department of Health <br />(DOH), the Occupational Safety and Health Administration <br />(OSHA) Standard and the city. <br />11. It is the contractor's responsibility to become familiar <br />with the permit and inspection requirements specified <br />by the various governmental agencies and the engineer <br />The contractor shall obtain all necessary permits prior <br />to construction and schedule inspections according to <br />agency instructions. All work performed shall comply with <br />the regulations and ordinances of the various governmental <br />agencies having jurisdiction over the work. <br />12. At least three (3) working days prior to construction, <br />the contractor shall notify the engineer and appropriate <br />agencies and supply them with the contractor's name, <br />starting date, projected construction schedule, all required <br />shop drawings and other information as required. Any work <br />performed prior to proper notifications may be subject to <br />removal and replacement at the contractor's expense. <br />13. The site shall be initially graded such that no offsite <br />area will be adversely affected by storm water runoff. <br />Runoff to the adjacent right-of-way shall be minimized. The <br />existing drainage facilities within the right-of-way shall <br />be protected at all times by the use of staked hay bales, <br />temporary grading, revegetation, etc. Any disturbed area <br />within the right-of-way shall be sodded. The contractor <br />shall final grade and hand rake all exposed earthwork areas <br />immediately prior to installation of sod. All areas shall be <br />protected from erosion caused by storm water runoff by <br />vegetation, staked hay bales, temporary grading, etc. <br />14. Upon completion of construction activities, the storm <br />water management system shall be cleaned of all debris, <br />silts, limerock, etc. <br />15. The contractor shall verify minimum separation between <br />water and sanitary sewer systems (18" minimum vertical and <br />10' minimum horizontal separations). Upon completion of <br />construction, the contractor shall provide written <br />verification documenting the minimum separation as <br />constructed. <br />16. Typical cover over utilities shall be 36". <br />17. During construction and/or maintenance of this project, <br />all safety regulations are to be enforced. The contractor <br />or his representative shall be responsible for the control <br />and safety of the traveling public and the safety of his <br />personnel. <br />18. The contractor shall comply with all Federal/State <br />Occupational Safety and Health Act (OSHA) Standards and any <br />other rules and regulations applicable to construction <br />and/or maintenance activities in the State of Florida. The <br />Contractor shall also comply with Chapter 442, Florida <br />Statutes (Toxic Substances in the Workplace), and any <br />CITY, COUNTY, or any other agency's rules and regulations <br />regarding safety. <br />19. All trenching and excavation operations MUST conform to <br />the requirements stated in the new "Trench Safety Act" <br />incorporated into OSHA standards 29 CFR 1926 Subpart P final <br />rule and the State of Florida Trench Safety Act. The <br />contractor shall recognize the OSHA safety standards, agree <br />to abide by them, and identify the cost to comply. <br />�..,��_-�',.r,.�:,:w�.,C-1, ��..E.` _-..,lS.�_l�� �.•r_�¢�y_� .�.u__�,.� � � CHI <br />PENSACOLA FORT T EE <br />WALTON <br />BEACH P CITY <br />CITY ./ <br />nzi <br />`OMMUNITY CE TER <br />GjUND HORIZONS N <br />FOR BROOM <br />j NEW <br />w PORT <br />RICHEY <br />ND HORIZ O,-,N.TS- HOMES,LLCPROJECT <br />LOCATION ST PETERSBURG <br />20. Further Contractor operations shall comply with 29CFR <br />1910.252 and NFPA 51 B for cutting and welding procedures. <br />21. All persons on (CITY, COUNTY OR STATE) property and <br />in area where the noise level exceeds 85db, must <br />wear hearing protection that complies with ANSI S3.19-74 <br />(ear muffs and/or approved ear plugs). This includes areas <br />where noisy equipment is in use (i.e. jack hammers, electric <br />or air drills, heavy equipment with open cabs, pipe cutting <br />saws, etc.) and in the plant where posted. <br />22. All work conducted in an elevated position shall comply <br />with 29CFR 1910.269. <br />23. All design application, installation, maintenance, removal <br />of all traffic control devices, warning devices and barriers <br />necessary to protect the public and workmen from hazards <br />within the projects shall be in accordance with the minimum <br />standards as set forth in the current edition of the State <br />of Florida and Traffic Design Standards. <br />24. All traffic control markings and devices shall conform <br />to the provision set forth in the "Manual on Uniform <br />Traffic Control Devices" prepared by the U.S. Department of <br />Transportation, Federal Highway Administration. <br />25. All Contractor owned or controlled vehicles and/or <br />equipment which will be operated on or within ten (10) feet <br />of the roadway shall be equipped with a minimum of one amber <br />360 degree Class I warning device. This device must meet <br />minimum standards for utility construction purposes, such as <br />a minimum of 500,000 candlepower and visible from 360 <br />degrees of mounting. The warning device(s) must be in <br />operation at all times that a vehicle/equipment if on the <br />roadway or within the ten (10) feet of runoff area and not <br />in a "normal" travel status. <br />26. Area designated by the Owner shall be utilized for <br />equipment storage and cover material staging. Materials and <br />supplies shall be stored only in those areas approved by the <br />owner. <br />27. In regard to the inspection of the project, Southwest <br />Florida Water Management District (SWFWMD) and the city <br />inspectors shall have the same right of review and <br />inspection as the Engineer of Record. Although it is <br />appropriate for the Engineer of Record to resolve questions, <br />diffic�ities, and disputes relative to interpretation of <br />contract documents or construction; SWFWMD and the city <br />reserve the right of final concurrence on such matters. <br />28. The city's Engineering inspector shall be <br />notified, and the Engineer's approval shall be <br />obtained, on all proposed field changes, alterations or <br />additions to the approved plans by the Contractor or <br />the Engineer of Record prior to the implementation of such <br />changes, alterations or additions. <br />29. The contractor shall obtain a separate permit for <br />any on -site burning. <br />30. If during construction activities any evidence of historic <br />resources including but not limited to aboriginal or <br />historic pottery, prehistoric stone tools, bone or shell <br />tools, historic trash pits, or historic building foundation, <br />are discovered, work shall come to an immediate stop <br />and the Florida Department of Historic Resources (State <br />Historic Preservation Officer) and Pasco County shall <br />be notified within two working days of the resources <br />found on the site. <br />31. All proposed signs must be applied for, approved and <br />permitted on an individual basis apart from ultimately <br />approved site plan. Approval of this site plan does <br />not constitute approval of any signage. <br />32. Handicap parking spaces will be Properly signed and <br />and striped in accordance with Florida Statute 316, the <br />Manual on Uniform Traffic Control Devices, or other <br />applicable standards. <br />33. The Engineer certifies that the site has been designed <br />in accordance with the American Disability Act. <br />34. All on -site parking spaces will be striped and signed in <br />accordance with the Manual on Uniform Traffic Control <br />Devices Latest Edition. Parking spaces, directional <br />arrows, and stop bars shall be striped in white. It shall <br />be the Owner/Developers responsibility to properly sign <br />and stripe the site in accordance with applicable standards. <br />35. All clear -site areas shall be kept free of any signage <br />plantings, trees, etc. In excess of three and one-half <br />feet in height. <br />36. All structures including buffer walls, retaining walls, <br />fencing, signage etc. require separate building permits. <br />37. No irrigation system or landscaping shall be installed in any <br />city right of way without the appropriate right <br />of way permit. <br />38. Upon completion of construction, the Owner/or Contractor <br />will be require to supply one set of complete "As -Built". <br />indicating all deviations during construction, certified <br />to the Engineer of Record. <br />33541 <br />VICINITY MAP <br />N.T.S. <br />PASCO COUNTY ATLAS MAP 63 <br />SECTI❑N 34, TOWNSHIP 25 SOUTH, RANGE 21 EAST <br />Al OWNER MR. DICK CHARRON, PRESIDENT <br />GRAND HORIZONS HOMES, LLC <br />37319 NEUKOM AVENUE <br />FLORIDA 33541 ZEP�IYRHILLS, <br />(8_13) 508-3586 <br />SURVEYOR: SIMMONS & BEALL, INC. <br />POST OFFICE BOX 1297 <br />DADS CITY, FLORIDA 33525 <br />(352) 567-0048 <br />&CONTRACTOR.- MR. RICK WOOLFOLK, GC <br />BULLS -EYE CONSTRUCTION <br />12814 C.R. 39S <br />LITHIA, FLORIDA 33547 <br />(813) 681-1955 <br />SARASOTA- <br />BRADENTON <br />1 <br />1 <br />DAYTONA BEACH <br />• 1 <br />•s; AL <br />MEL:. <br />COCOA <br />IFT PIERCE <br />WEST <br />PALM <br />rI <br />SUNSHINE STATE ONE -CALL OF FLORIDA <br />DESIGN TICKET #313903577-000 <br />UTILITY COMAPNIES.- <br />Mfi?ARQo,yoy ( PROGRESS ENERGY <br />A ON.• dui SE6LL dTTBNTlON.• CUSTOAZW ShRYlCE CENTBR <br />93 NORTH ILfIN STRRET PHO1V�r (800) 700-8744 <br />\PUTTER GARDEN, FLORIDA 34787 <br />PRONE: (407) 814-5344 <br />VINMON FLORIDA INC. <br />AT FJVTION: DAVID IIYNNS <br />1909 US BVE 301 N <br />TAM,PA, FLORIDA 33819 <br />PHONE: (813) 827-8343 <br />PASCO COUNTY TRAFFIC <br />ATTENTION: ROBERT BECK <br />7530 LITTLE ROAD, SUITE 124 <br />NEIP PORT RICKEY, FLORIDA 348: <br />PRONE: (727) 847 8139 Ex.•8823 <br />TECO: PEOPLE GAS <br />ATTENTION: PHYLLIS .FRIDGES <br />1400 CHANNFELSIDL' D.RIPE <br />TAMPA, FLORIDA 33805 <br />PHONE: (813) 275-3742 <br />BRIGBT HOUSE ME77ORKY <br />ATTENTION.• KATBY MCDONALD <br />30432 S.R. 54 <br />WESLEY CHAPEL FLORIDA 33543 <br />PHONE: (813) 882-0522 AX.•84402 <br />TAMPA ELECTRIC <br />ATTENTION.• iM72 ER YTTR"O <br />P.O. BOX III <br />TAMPA, FLORIDA 33801 <br />PHONE: (813) 275-3433 <br />0 y <br />INDEX OF SHEETS 37 �ol o <br />�y, <br />SHEET NO. SHEET DESCRIPTION <br />1 COVER SHEET AND GENERAL NOTES <br />2 SURVEY PLAN (EXISTING SITE CONDITIONS) <br />3 SITE PLAN <br />4 PA VING, GRADING, DRAINAGE PLAN AND DETAILS <br />5 SECTIONS <br />6 UTILITY PLAN <br />7 LANDSCAPE AND TRAFFIC SIGNAGE PLAN <br />8 BEST MANAGEMENT PRACTICE PLAN AND DETAILS <br />9 PRE -DEVELOPMENT DRAINAGE PLAN <br />10 POST DEVELOPMENT DRAINAGE PLAN <br />. ' "f' 3„ <br />BEFORE DIGGING CALL M. ALI SHASTI-NAZEM, M., <br />SUNSHINE STATE ONE -CALL OF FLA :;A_ <br />DLICEN 427 <br />1-800-432-4770 <br />FSS 93.240, SECTIONS 556.101-556.111 <br />REQUIRES MIN. OF 2 DAYS AND MAX. OF SIGNATURE <br />5 DAYS NOTICE BEFORE YOU EXCAVATE. Z <br />DATE <br />(NOT VAUD WITHOUT SEAL) <br />co <br />Z <br />O <br />N O <br />LL <br />O <br />Cr <br />W <br />W <br />Z <br />Z <br />w <br />0 <br />Z <br />Q <br />Z <br />w <br />J <br />U <br />IX <br />W <br />IL <br />m <br />w <br />C-)H� <br />0 <br />o <br />Zl- <br />C, <br />CO <br />I' <br />", <br />0 <br />P <br />W <br />00 <br />�!• <br />p <br />b <br />� <br />0 <br />o <br />o <br />ao <br />N b <br />a <br />h <br />o <br />o <br />w <br />M•.N., <br />aMp <br />O <br />U <br />C3 <br />0 <br />�u <br />t <br />Nc�i w <br />� <br />o <br />� <br />DATE: 11-11-09 <br />SCALE: N's <br />FIELD BK <br />DRWNBY.• CET <br />CHECKED aids <br />SHEET NO. <br />.E. <br />1 OF l0 <br />EC PROJECT NO. <br />0965C <br />