ENGINEER'S NOTES:
<br />1,
<br />DESIGN WIND SPEED: 140
<br />MPHult / 110 MPHasd , 3 sec gust
<br />PER ATC HAZARDS BY
<br />L❑CATI❑N
<br />2,
<br />RISK CATEGORY PER FBC
<br />17 6TH EDITI❑N Table 1604,5 : II
<br />3,
<br />EXPOSURE CATEGORY =
<br />"B"
<br />4,
<br />INTERNAL PRESSURE C❑EFFICIENT =
<br />+/- 0.18 (ENCLOSED BLDG)
<br />5,
<br />COMPONENTS & CLADDING DESIGN PRESSURES PER ASCE 7-10:
<br />FIGURE 30.5-1
<br />(ROOF)
<br />ZONE 11o:
<br />+10/-21
<br />psf
<br />ZONE 2a;
<br />+10/-37
<br />psf
<br />ZONE Sal
<br />+10/-55
<br />psf
<br />(WALLS)
<br />ZONE 4Io:
<br />+21/-23
<br />psf
<br />ZONE 510:
<br />+21/-27
<br />psf
<br />GENERAL NOTES
<br />BUSINESS GROUP B 393 SQ FT/100 = 4 PEOPLE PER TABLE 100412 FBC
<br />GROUP S LOW HAZARD 2007 SQ FT/500 = 4 PEOPLE PER TABLE 1004.1.2 FBC
<br />3 SUITES @ 2400 = 7200 SQ FT
<br />INTERIOR REQUIREMENTS
<br />FLAME SPREAD/SMOKE DEV.—EXIT ACCESS UNSPRK1 TYPE 'B' FLAMESPREAD 26-75 SMOKE DEV, 0-450
<br />FLAME SPREAD/SMOKE DEV,—EXIT ACCESS SPRK: TYPE 'C' FLAMESPREAD 76-200 SMOKE DEV, 0-450
<br />FLAME SPREAD/SMOKE DEV.-OTHER SPACES UNSPRK: TYPE 'C' FLAMESPREAD 76-200 SMOKE DEV. 0-450
<br />FLAME SPREAD/SMOKE DEV.-OTHER SPACES SPRK, TYPE 'C' FLAMESPREAD 76-200 SMOKE DEV, 0-450
<br />X
<br />W
<br />TABLE 803,11
<br />INTERI❑R WALL AND CEILING FINISH REQUIREMENTS BY ❑CCUPANCYk
<br />Z❑NING CLASSIFICATI❑N:
<br />BUILDING AREA:7200 SQ,FT, TOTAL
<br />BUILDING USE: BUSINESS
<br />SPECIAL OCCUPANCY: N/A
<br />GROUP: GROUP B
<br />TYPE OF CONSTRUCTION: 3B
<br />MIXED C❑NSTRUCTI❑M NO
<br />BUILDING HEIGHT: <35"
<br />SPRINKLED: NO
<br />APPLICABLE BUILDING CODES
<br />FLORIDA BUILDING CODE (FBC) Gth ed. BUILDING (2017)
<br />FLORIDA BUILDING CODE (FBC) 6th ed. MECHANICAL (2017)
<br />FLORIDA BUILDING CODE <FBC) 6th ed. ENERGY (2017)
<br />FLORIDA BUILDING CODE (FBC) 6th ed. PLUMBING (2017)
<br />FLORIDA FIRE PREVENTI❑N CODE Gth ed.(2017)
<br />NATI❑NAL ELECTRICAL CODE, 2014 EDITI❑N
<br />FLORIDA ACCESSIBILITY CODE 6th ed. (2017)
<br />AMERICANS W/DISSABILITIES ACT (ADASAD), ed. (2010)
<br />FIXTURES SHOWN MEET REQUIREMENTS
<br />GROUP
<br />SPRINKLERED
<br />N❑NSPRINKLERED
<br />Interior exit stairways and r
<br />and exit passageways a, b
<br />mpQorridors and
<br />enclosure for exitenclosed
<br />access stairways
<br />and ramps
<br />Rooms and
<br />spaceg
<br />Interior exit stairways
<br />ramps and exit
<br />passageways a, b
<br />aBdr Idors and
<br />encrosure for exit
<br />access stairways
<br />and ramps
<br />Rooms and
<br />enclosed
<br />spaces c
<br />A-1 & A-2
<br />B
<br />B
<br />C
<br />A
<br />A
<br />B e
<br />A-3f, A-4, A-5
<br />B
<br />B
<br />C
<br />A
<br />A
<br />C
<br />B E, M, R-1
<br />B
<br />C
<br />C
<br />A
<br />B
<br />C
<br />R-4
<br />B
<br />C
<br />C
<br />A
<br />B
<br />B
<br />F
<br />C
<br />C
<br />C
<br />B
<br />C
<br />C
<br />H
<br />B
<br />B
<br />C9
<br />A
<br />A
<br />B
<br />I-1
<br />B
<br />C
<br />C
<br />A
<br />B
<br />B
<br />I-2
<br />B
<br />B
<br />B h.1
<br />A
<br />A
<br />B
<br />I-3
<br />A
<br />AJ
<br />C
<br />A
<br />A
<br />B
<br />I-4
<br />B
<br />B
<br />Bh.1A
<br />A
<br />B
<br />R-2
<br />C
<br />C
<br />C
<br />B
<br />B
<br />C
<br />R-3
<br />C
<br />C
<br />C
<br />C
<br />C
<br />C
<br />S
<br />C
<br />C
<br />C
<br />B
<br />B
<br />C
<br />U
<br />No restrictions
<br />No restrictions
<br />For SIB 1 Inch = 25.4 mm, 1 square foot = 0.0929 m2.
<br />a.Class C Interior finish materials shall be permitted for wainscotting or paneling of not more than 1,000 square feet of applied surface area In the grade
<br />Lobby where applied directly to a noncombustible base or over furring strips applied to a noncombustible base and flreblocked as required by Section 803,13.1.
<br />b.In other than Group I-3 occupancies In buildings less than three stories above grade plane, Class B Interior finish for nonsprinklered buildings and Class C
<br />Interior finish for sprinklered buildings shall be permitted In Interior exit stairways and ramps,
<br />c.Requirements for rooms and enclosed spaces shall be based upon spaces enclosed by partitions. Where a fire -resistance rating Is required for structural
<br />elements, the enclosing partitions shalt extend from the floor to the tellingq Partitions that do not comply with this shall be considered enclosing spaces
<br />and the rooms or spaces on both sides shall be considered one. In determini�ng the applicable requiremen-ts for rooms and enclosed spaces, the specific
<br />occupancy thereof shall be the governing factor regardless of the group classification of the building or structure,
<br />d.Lobby areas In Group A-1, A-2 and A-3 occupancies shalt not be less than Class B materials.
<br />e.Class C Interior finish materials shall be permitted In places of assembly with an occupant load of 300 persons or less.
<br />f.For places of religious worship, wood used for ornamental purposes, trusses, paneling or chancel furnishing shall be permitted.
<br />g.Class B material is required where the building exceeds two stories.
<br />h.Class C Interior finish materials shall be permitted In administrative spaces.
<br />I.Class C Interior finish materials shalt be permitted In rooms with a capacity of four persons or less.
<br />.Class B materials shall be permitted as wainscotting extending not more than 48 Inches above the finished floor In corridors and exit access stairways and ramps.
<br />k.Flnlsh materials as rovided for In other sections of this code.
<br />(.Applies when protected by an automatic sprinkler system Installed in accordance with Section 903.3.1.1 or 903.3.1.2.
<br />INTERIOR FINISH SCHEDULE
<br />INTERIOR FINISHES TO BE DETERMINED BY OWNER
<br />RESTROOM FLOORS TO BE A NON ABORBENT MATERIAL
<br />RESTROOM WALL TO BE A NON ABSORBENT MATERIAL
<br />MINIMUM 4W A.F.F.
<br />GENERAL NOiTES
<br />k:"
<br />- 0) i; r
<br />�' .'�' � ill -NSF `< i�:�H,►� -i�: ti��)1 � �1 1R: r: liti�? F $�1111 ,* -1 0'1 ^� 10CJ'1�`�'�'F
<br />u ir;
<br />l\ ; I F DI 4 4F 1r, �'�� � * (' ' \ " F {"A QO-K 20�.y fii
<br />'T I ��I,iti�� ( ;�jf��� ti�I� i�'1_i l�)�"!��ir., I� [�?I�( ;��i[•1F �i L�)?�)IT ��� iF(�T �;^J 1''
<br />r
<br />ill Jut, ill F6
<br />I
<br />1
<br />EXTE MOO F� WINDOWS & DOO OO F'� ASSEM =LIES:
<br />FFF I*'s, •rI �'� .� h,;��� S �h,.I E ( F5 c�li; !N ;�C n��� �h(?F 'tiI�I�, N� 6�",1�+, �., �1),�
<br />r�iDD =E'.".tiff
<br />SAFE 1 YLAZING.
<br />I hereloy certify that I have reviewed this plan and found it to loE in
<br />compliance with ASCE 7-10 and the Florida Building Code 2017 6th Edition
<br />David W, Smith, P.E. # 3608
<br />ENGINEER LICENCE #53608
<br />e
<br />INDEX S H T #
<br />1, C❑VER
<br />2, FLOOR PLAN
<br />3, SIGHT PLAN
<br />4, POWER PLAN
<br />5, HVAC PLAN
<br />6, FIRE SAFETY
<br />7, UL SHEETS
<br />All WM SHALL COMPLY WITH
<br />NFFA CODES AND STANDARDS
<br />ENDATE /I • f ��
<br />Y OF ZEP147Y H, i.S
<br />;-IRE MD LIFE SAFETY EXAMINER_,�
<br />PLAN
<br />>rlt►I W «pT:
<br />CWT iw zapire j,
<br />KAY.il (;
<br />ALL WORK SHALL COMPLY WITH PREVAILING
<br />CODES FLORIDA BUILDING CODE,
<br />NATIONAL ELECTRIC' _:ODE,
<br />AND THE CITY OF ZEPHYRHILLS
<br />ORDINANCES
<br />11
<br />PARCEL: 19- 26- 22- 0010- 00000- 0130
<br />CHANCEY PARTNERS
<br />3773 CORREIA DR
<br />ZEPHYRHILLS, FLORIDA
<br />D.W.SMITH,M.S.,P.E.#53608
<br />FLORIDA PROFESSI❑NAL ENGINEER LICENSE NUMBER 53608
<br />PROJECTS ENGINEERING CONSULTANT
<br />9909 WALLAST❑N DRIVE—DADE CITY, FLORIDA 33525
<br />PHONE: 813-469-2289 E-MAIL: dwsHp0earth l i nk. net
<br />RICK GOLLHARDT - DRAFTSMAN
<br />813- 781- 3651
<br />rgollhardt@tampabay.rr.com
<br />COVER SHEET
<br />SCALE
<br />DO NOT SCALE
<br />DESIGN/DRAWN
<br />R. GOLLHARDT
<br />DATE
<br />9 OCT 2020
<br />CHECKED
<br />D.W.S.,p.e.
<br />SHEET OF
<br />1 OF 7
<br />JOB NO.
<br />V-
<br />J
<br />2020-1 Q03
<br />3773 �1