Laserfiche WebLink
1 "`10' <br />1 1 30 3� 26 1� 0 20 40 60 1 90 4� 2� 0 40 80 120 7 2 0 150 <br />1"=20' 1"=30'Mill 1"=40' � M 1"=50'mmmmmm <br />1"=100' <br />PROJECT NAME <br />MEDICAL BUILDING <br />MODIFICATIONS <br />I Htbt UKAWINUb HA5 bttN UKtA I tU h KUM <br />PREVIOUS CONTRACT DOCUMENTS, WHILE <br />ACTUAL CONDITIONS HAVE BEEN INVESTIGATED <br />TO THE BEST OF THE DESIGNER ABILITY, THE <br />CONTRACTOR SHALL FIELD VERIFY THE EXISTING <br />CONDITIONS DURING THE COURSE OF WORK <br />AND COORDINATE ANY DISCREPANCIES WITH <br />THE ARCHITECT/DESIGNER/ENGINEER <br />MODIFIED MECHANICAL. <br />PLAN <br />M1-1 <br />HVAC DIAGRAM NOTES. <br />THE HVAC DIAGRAM IS NOT INTENDED TO SHOW EXACT DETAIL OF EVERY ITEM REQUIRED TO MEET THE CODE <br />REQUIREMENTS. <br />THE DUCT ROUTING SHOWN IN GENERAL IN NATURE; FIELD CONDITIONS MAY DICTATE EXACT CONFIGURATION OF THE HVAC <br />SYSTEM. CODE SECTIONS ARE LISTED FOR EACH HVAC SYMBOL FOR THE HVAC CONTRACTOR TO REFERENCE PRIOR TO <br />INSTALLATION. <br />SIZE TRANSFER AIR DEVICES 1.5 TIMES THE SIZE OF THE SUPPLY AIR TO THE ENCLOSED SPACE. 1" UNDERCUT DOOR <br />ALLOWS ONLY 30 CFM OF RELIEF AIR. <br />1) HVAC INSTALLATION TO COMPLY WITH THE 2020 FLORIDA BUILDING CODE (7TH EDITION), ENERGY, AND MECHANICAL <br />CODES. OBTAIN ALL NECESSARY PERMITS AND INSPECTIONS. <br />2) PROVIDE ACCEPTABLE INDOOR AIR QUALITY PER THE 2020 FLORIDA MECHANICAL CODE SECTION 403.3 MECHANICALLY <br />INDUCED OUTDOOR AIR IS ONLY REQUIRED IF THE CALCULATED MINIMUM OUTDOOR AIR REQUIRED EXCEEDS THE OUTDOOR <br />AIR THAT ENTERS THE BUILDING NATURALLY BY INFILTRATION COMMERCIAL BUILDINGS WILL HAVE MECHANICALLY INDUCED <br />FRESH AIR PER THE VENTILATION CALCULATIONS AND THE BUILDING AIR BALANCE SCHEDULE. <br />3) COORDINATE LOCATION OF ALL EQUIPMENT, FANS, AIR DEVICES, AND BUILDING PENETRATIONS WITH THE GENERAL <br />CONTRACTOR, PROTECT THE STRUCTURE PER FMC 302, FABRICATE AND INSTALL HVAC SYSTEMS PER THE 2020 FLORIDA <br />MECHANICAL CODE AND PRODUCT INSTALLATION INSTRUCTIONS. <br />4) MECHANICAL INSTALLER TO FIELD VERIFY CLEARANCES AND ACCESSIBILITY PRIOR TO FABRICATION OR INSTALLATION OF <br />ANY HVAC WORK. PROVIDE A MEANS FOR WIND RESISTANCE ON ALL EXTERIOR MOUNTED EQUIPMENT PER SECTION FMC <br />301.13. ENGINEER SEAL IS REQUIRED FOR EQUIPMENT SUSPENDED FROM ATTIC TRUSSES AND FOR EXTERIOR EQUIPMENT <br />MOUNTED ABOVE GROUND LEVEL. <br />5) ALL DUCT DIMENSIONS SHOWN ARE CLEAR INTERIOR DUCT DIMENSIONS, ADD 3" TO LISTED SIZE FOR EXTERIOR <br />DIMENSIONS. FIBERGLASS DUCT BOARD EQUAL TO KNAUF 1y" R-6, INSTALL PER SMACNA STANDARDS. FLEXIBLE DUCT <br />WORK EQUAL TO ATCO 36 SERIES R-6 CLASS ONE AIR DUCT. CONSTRUCT AND SUSPEND DUCTWORK FROM THE BUILDING <br />STRUCTURE PER THE 2020 FLORIDA MECHANICAL CODE CHAPTER 6, SEAL ALL DUCTWORK PER UL-181 AND FMC CHAPTER <br />6. <br />6) PROVIDE A CONDENSATE DRAIN SYSTEM PER THE 2020 FLORIDA MECHANICAL CODE SECTION 307 AND A REFRIGERANT <br />PIPING SYSTEM PER FMC SECTION 1107. EXTEND CONDENSATE DRAIN DISCHARGE 12" FROM EXTERIOR WALL TO GRASS (OR <br />OTHER APPROVED METHOD), PROVIDE PIPING SUPPORT FOR BOTH CONDENSATE DRAINS AND REFRIGERANT PIPING PER FMC <br />305. <br />7) PROVIDE A BALANCED RETURN AIR SYSTEM PER THE 2020 FLORIDA MECHANICAL CODE SECTION 601.4. ALL CLOSE ABLE <br />ROOMS REQUIRE 1" UNDERCUT ON INTERIOR DOORS PLUS A MEANS FOR AIR TRANSFER OR AIR RETURN. PRESSURE <br />DIFFERENTIALS NOT TO EXCEED .01 INCH W.G. (30CFM/DOOR) <br />8) ATTIC MOUNTED EQUIPMENT MUST CONTAIN A DEVICE TO ALERT THE HOMEOWNER IF THE CONDENSATE DRAIN LINE IS <br />NOT WORKING PROPERLY. POST A NOTICE ON THE ELECTRICAL PANEL INDICATING TO THE HOMEOWNER THE AIR HANDLER IS <br />LOCATED IN THE ATTIC SPACE WITHIN 6' OF THE ACCESS PANEL. SEE SECTION 610 OF THE FLORIDA ENERGY CODE FOR <br />FULL COMPLIANCE DESCRIPTION. <br />9) INSTALLING CONTRACTOR MUST PROVIDE A COPY OF THE HVAC HEAT LOAD CALCULATIONS, FLORIDA ENERGY <br />CALCULATIONS, AND A HVAC DIAGRAM TO THE BUILDING OWNER FOR REVIEW AND APPROVAL. INSTALLING CONTRACTOR <br />WILL CONDUCT A BUILDING OWNER INTERVIEW TO DISCUSS DESIGN CONDITIONS, INDOOR AIR QUALITY, HEALTH PROBLEMS, <br />COMBUSTION AIR SAFETY, ALLOWABLE SWINGS IN TEMPERATURE AND HUMIDITY, ZONING, USE OF INTERNAL AND EXTERNAL <br />SHADING DEVICES, INTERIOR HEAT AND MOISTURE PRODUCING APPLIANCES, ENTERTAINING LARGE NUMBERS OF PEOPLE, <br />STAND ALONE DEHUMIDIFICATION WITH HUMIDISTAT, AND ANY INFORMATION NOT SHOWN ON THE BUILDING DRAWINGS. <br />MULTISTAGE CONDENSING UNITS OR STAND ALONE DEHUMIDIFICATION IS REQUIRED FOR ALL STRUCTURES LOCATED IN <br />SUB —TROPIC ENVIRONMENTS TO ACHIEVE ACCEPTABLE INTERIOR HUMIDITY LEVELS DURING PART LOAD CONDITIONS. <br />HVAC DIAGRAM <br />SYMBOLS <br />CEILING REGISTER <br />RECTANGULAR <br />AIR HANDLING UNIT <br />Em-> <br />TWO WAY THROW <br />0 <br />DUCTWORK <br />HORIZONTAL MOUNT <br />FROM STRUCTURE <br />FMC SECTIONS 303 <br />THROUGH 312 <br />® CEILING REGISTER <br />< <br />FLEXIBLE <br />���..�' <br />FOUR WAY THROW <br />DUCTWORK <br /><A- <br />CEILING GRILLE <br />RETURN AIR FILTER <br />ROOFTOP PACKAGE UNIT <br />® FASTENED TO ROOF CURB <br />FMC SECTIONS 303 <br />THROUGH 312 <br /><A- 01 E°- SIDEWALL GRILLE <br />DIRECT TRANSFER AIR <br />RTU= ROOF TOP UNIT <br />T/A= TRANSFER AIR <br />MUA= MAKE UP AIR <br />BD= BYPASS DAMPER <br />CU= CONDENSING UNIT <br />S/A= SUPPLY AIR <br />SF= SUPPLY FAN <br />VTE= VENT TO EXTERIOR <br />AHU= AIR HANDLING UNIT R/A= RETURN AIR <br />EF= EXHAUST FAN <br />CFM= CUBIC FEET PER MINUTE <br />PKG= PACKCAGE UNIT <br />0/A= OUTSIDE AIR <br />FPM= FEET PER MINUTE <br />-L}> UNDERCUT DOOR <br />DH= DE -HUMIDIFIER <br />BRD= BAROMETRIC RELIEF AIR DAMPER <br />ZD= ZONE DAMPER <br />OUTDOOR FRESH AIR CALCULATIONS PER THE 7TH EDITION, 2020 FBC MECHANICAL TABLE 403.3.1.1. <br />OCCUPANCY LOAD: <br />(2,072 SF x <br />40 PEOPLE)/1,000 SF = 83 PEOPLE <br />PEOPLE OUTDOOR FRESH AIR RATE (CFM) = <br />83 PEOPLE <br />x 5 CFM/PERSON = 415 CFM <br />AREA OUTDOOR FRESH AIR <br />RATE (CFM) = <br />2,072 SF x <br />0.06 CFM/SF = 124 CFM <br />REQUIRED OUTDOOR FRESH <br />AIR (CFM) = <br />415 CFM + <br />124 CFM = 539 CFM <br />PROVIDED OUTDOOR FRESH <br />AIR RATE (CFM)= <br />539 CF / <br />(1) 3.5 TONS = 539 CFM PER 3.5 TON UNIT. <br />OWNER: <br />ADAA REAL ESTATE LLC <br />2653 BRUCE B DOWNS BLVD. <br />WESLEY CHAPEL, FL 33544 <br />PROJECT ADDRESS <br />38058 ARBOR RIDGE DRIVE. <br />ZEPHYRHILLS, FL 33540 <br />DRAWING BY: <br />DANIEL JALIL <br />Associate AIA <br />M.A. In Architecture & Planning <br />10233 CELTIC ASH DR. <br />Ruskin, FL 33753 <br />Phone (813) 240-3537 <br />THIS DRAWING MEASURING 24"x36" IS THE PROPERTY OF DANIEL <br />JALIL AND MAY NOT BE USED OR REPRODUCED WITHOUT HIS <br />WRITTEN PERMISSION.. <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE <br />DATE IS SIGNED AND SEALED. <br />ENGINEER: <br />I HEREBY CERTIFY THAT I HAVE <br />REVIEWED THE ATTACHED DESIGN AND <br />FOUND IT TO BE IN COMPLIANCE WITH <br />THE 7TH EDITION OF THE FLORIDA <br />BUILDING CODE 2020. <br />DANIEL JAMES COOREY P.E. <br />FL 77065 <br />Phone (813) 507-9166 <br />DATE ISSUED FOR: <br />SHEET TITLE <br />MODIFIED MECHANICAL <br />PLAN <br />JOB No. ZPH-0821 <br />SCALE AS NOTED <br />DATE AUG-09-21 <br />DRAW BY DJ <br />CHECKED BY DJ <br />PLOT DATE 08-09-21 <br />DRAWING No <br />3"=1'-0" 1 1 /2"=1'-0" 3/41=1'-0" 1 /4"=1'-011 1 /8"=1'-0" 1 /16"=1'-0" <br />o 1 0 2 2 0 2 4 8 6 0 12 <br />