Laserfiche WebLink
ill'low 15 0 11 jo 30 1 20 3"1 2� 10 0 20 40 so 1 30 1 90 1 40 si . 4L PM !6ON 0 iim 40 80 120 1 of <br />1 "=100' 1 1 50 m pi 1 aoo <br />PROJECT NAME <br />MEDICAL BUILDING <br />MODIFICATIONS <br />LIFE SAFETY SYMBOLS <br />DO <br />WALL MOUNTED FIRE EXTINGUISHER <br />DIRECTION OF EGRESS <br />L:i - - <br />PATH OF TRAVEL <br />EXIT LIGHT SYMBOLS <br />COMBINATION EXIT, EMERGENCY LIGHT FIXTURE <br />ZZ <br />ILLUMINATED DIRECTIONAL EXIT SIGNAGE, CEILING MOUNTED <br />® <br />ILLUMINATED EXIT SIGNAGE, CEILING MOUNTED <br />ILLUMINATED EXIT SIGNAGE, WALL MOUNTED <br />EMERGENCY LIGHT FIXTURE, WALL PACK WITH TWIN HEADS <br />SAFETY PLAN <br />LIFE SAFETY GENERAL NOTES: <br />PROVIDE PORTABLE EXTINGUISHER WITH A RATING OF NOT LESS <br />THAN 2—A WITHIN 75—FOOT TRAVEL DISTANCE TO ALL PORTIONS OF <br />THE BUILDING AND MOUNTED WITH OPERABLE CONTROLS AT 48" <br />A.F.F.; ADDITIONAL EXTINGUISHER MAY BE REQUIRED BY AUTHORITY <br />HAVING JURISDICTION. <br />FIRE EXTINGUISHERS SHALL BE CURRENTLY DATED AND TAGGED BY <br />A LICENSED FIRE EQUIPMENT COMPANY. <br />PROVIDE EXIT SIGN WITH 6" LETTERS OVER REQUIRED EXITS; <br />EMERGENCY LIGHTS SHALL MEET OR EXCEED MINIMUM ILLUMINATION <br />REQUIREMENTS PER FBC 2020 AND FLORIDA FIRE PREVENTION CODE <br />2020 (7th EDITION) (7.9.1.1)(13.2.9). TACTILE EXIT SIGNAGE SHALL <br />BE MOUNTED AT 5'-0" A.F.F. LATCH SIDE OF THE DOOR. <br />ADDITIONAL SIGNS MAY BE REQUIRED BY AUTHORITY HAVING <br />JURISDICTION. <br />THE FLOORS AND OTHER WALKING SURFACES WITHIN AN EXIT AND <br />WITHIN THE PORTION OF THE EXIT ACCESS AND EXIT DISCHARGE <br />DESIGNATED IN 7.8.1.1 SHALL BE ILLUMINATED AS FOLLOWS: (2) THE <br />MINIMUM ILLUMINATION FOR FLOOR AND WALKING SURFACES SHALL <br />BE TO VALUES OF AT LEAST 1 FOOT—CANDLE (10.8 LUX), <br />MEASURED AT THE FLOOR. (3) IN BUSINESS OCCUPANCIES, THE <br />ILLUMINATION OF THE WALKING SURFACES OF EXIT ACCESS SHALL <br />BE AT LEAST 0.2 FOOT—CANDLE (2.2 LUX) DURING PERIODS OF <br />PERFORMANCE OR PROJECTIONS INVOLVING DIRECT LIGHT <br />EGRESS DOORS SHAL OPEN IN DIRECTION OF EGRESS <br />(7.2.1.4.2) EGRESS DOORS SHALL HAVE PANIC HARDWARE <br />(13.2.2.2.4) RELEASE MECHANISMS ON DOORS SHALL BE <br />MOUNTED BETWEEN 34" AND 48" A.F.F. (7.2.1.7.1) <br />DURING ITS SWING ANY DOOR IN A MEANS OF EGRESS SHALL <br />LEAVE NOT LESS THAN ONE—HALF OF THE REQUIRED WIDTH OF <br />AN ISLE, CORRIDOR PASSAGEWAY, OR LANDING UNOBSTRUCTED <br />AND SHALL PROJECT NOT MORE THAN 7" INTO THE REQUIRED <br />WIDTH (7.2.1.4.3.1) <br />THE FORCE REQUIRED TO OPEN ANY DOOR MANUALLY IN A <br />MEANS OF EGRESS SHALL NOT EXCEED 15 POUNDS, TO <br />RELEASE THE LATCH AND 30 POUNDS TO SET THE DOOR IN <br />MOTION. (7.2.1.4.5). OPENING FORCE FOR INTERIOR DOORS <br />WITHOUT CLOSERS SHALL NOT EXCEED 5 POUNDS. <br />DEAD END CORRIDORS SHALL NOT EXCEED 50 FT., COMMON <br />PATHS OF TRAVEL SHALL NOT EXCEED 100 FT., TRAVEL <br />DISTANCE TO AN EXIT SHALL BE LESS THAN 200 FT., AISLES <br />SHALL NOT BE LESS THAN 36". <br />BUILDING ADDRESS NUMBERS SHALL BE PLACED ON IN A <br />VISIBLE LOCATION ON THE PRIMARY FACADE, LETTERS SHALL <br />BR A MINIMUM OF 6" HEIGHT AND SHALL CONTRAST WITH THE <br />WALL FINISH WHERE THEY ARE AFFIXED <br />ALL CONSTRUCTION, DEMOLITION AND RENOVATION SHALL COMPLY <br />WITH REQUIREMENTS OF NFPA 241; STANDARDS FOR FOR <br />SAFEGUARDING CONSTRUCTION ALTERATION AND DEMOLITION <br />OPERATIONS. <br />A KNOX-BOX SHALL BE MOUNTED TO EXTERIOR WALL ADJACENT TO <br />FRONT ENTRY DOORS - COORDINATE TYPE AND FINISH WITH OWNER <br />AND ARCHITECT PRIOR TO PURCHASE AND INSTALLATION. <br />COORDINATE MOUNTING WITH MANUFACTURER SPECIFICATIONS. <br />ALL INTERIOR WALLS AND CEILING FINISHES TO BE CLASS "C" FINISH <br />MATERIALS AND SHALL MEET MINIMUM APPLICABLE REQUIREMENTS OF <br />THE 2020 FLORIDA BUILDING CODE (7TH EDITION), SECTION 803 AND <br />TABLE 803.11. <br />'LEGENbi, <br />= FIRE EXTINGUISHER <br />2A10BC WALL MOUNTED (TYP) <br />OWNER: <br />ADAA REAL ESTATE LLC <br />2653 BRUCE B DOWNS BLVD. <br />WESLEY CHAPEL , FL 33544 <br />PROJECT ADDRESS <br />38058 ARBOR RIDGE DRIVE. <br />ZEPHYRH I LLS, FL 33540 <br />DRAWING BY: <br />DANIEL JALIL <br />Associate AIA <br />M.A. In Architecture & Planning <br />10233 CELTIC ASH DR. <br />Ruskin, FL 33753 <br />Phone (813) 240-3537 <br />THIS DRAWING MEASURING 24"x36" IS THE PROPERTY OF DANIEL <br />JALIL AND MAY NOT BE USED OR REPRODUCED WITHOUT HIS <br />WRITTEN PERMISSION.. <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE <br />DATE IS SIGNED AND SEALED. <br />wide f►TA 17 <br />I HEREBY CERTIFY THAT I HAVE <br />REVIEWED THE ATTACHED DESIGN AND <br />FOUND IT TO BE IN COMPLIANCE WITH <br />THE 7TH EDITION OF THE FLORIDA <br />BUILDING CODE 2020. <br />DANIEL JAMES COOREY P.E. <br />FL 77065 <br />Phone (813) 507-9166 <br />DATE ISSUED FOR: <br />SHEET TITLE <br />LIFE SAFETY PLAN <br />& SAFETY NOTES <br />JOB No. ZPH-0821 <br />SCALE AS NOTED <br />DATE AUG-09-21 <br />DRAW BY DJ <br />CHECKED BY DJ <br />PLOT DATE 08-09-21 <br />DRAWING No <br />3"=1'-0" 1 1/2"=1'-0"FM 3/4"=1'-0" <br />0 1 0 2 2 0 2 4 <br />1 /4"=1'-0" 8 1 /8"=1'-0" 6 PE <br />o <br />LS1-1 <br />1 /16"=V-0" 12 0 <br />