Laserfiche WebLink
ill=10' <br />1 1 30 <br />1 "=20' 30 20 10 0 20 40 60 <br />15 90 <br />1 "=30' 30 <br />1 "=40' %0 . 4 20 0 40 80 120 <br />7 150 <br />1 "=50'PIN <br />1 "=100' <br />PROJECT NAME <br />MEDICAL BUILDING <br />MODIFICATIONS <br />I NLJL UKAYYINUZi NAJ GLLN (.KLA I LU r PLUM <br />PREVIOUS CONTRACT DOCUMENTS, WHILE <br />ACTUAL CONDITIONS HAVE BEEN INVESTIGATED <br />TO THE BEST OF THE DESIGNER ABILITY, THE <br />CONTRACTOR SHALL FIELD VERIFY THE EXISTING <br />CONDITIONS DURING THE COURSE OF WORK <br />AND COORDINATE ANY DISCREPANCIES WITH <br />THE ARCHITECT/DESIGNER/ENGINEER <br />DEMO PLAN <br />SCALE: 1 /4" = 1'-0 <br />Al —01 <br />EXISTING BUILDING / CMU EXTERIOR WALL/ <br />STORE FRONT GLAZING TO REMAIN <br />INTERIOR WALLS TO REMAIN <br />r 1 <br />I I <br />INTERIOR WALLS FOR DEMOLITION <br />GENERAL NOTES: <br />1. FURNITURE AND APPLIANCES <br />TO BE SELECTED AND <br />PROVIDED BY OWNER <br />— SHOWN IN PLAN ARE FOR <br />REFERENCE ONLY. <br />2. EXISTING GLAZING <br />AND STOREFRONT DOOR SYSTEM <br />TO REMAIN — NEW DOUBLE <br />DOOR (D1) AND SINGLE <br />DOOR (D2). <br />DEMOLITION NOTES: <br />1. REMOVE ALL EXISTING CONSTRUCTIONS AND FINISHES NECESSARY <br />FOR THE COMPLETION OF THE WORK AS DEPICTED ON THE DRAWINGS <br />INCLUDING BUT NOT LIMITED TO ITEMS SHOW IN THE PLANS WITH <br />DASHED LINES/HATCHED. NECESSARY DISCONNECTS AND ALTERATIONS <br />TO EXISTING MECHANICAL AND ELECTRICAL SHALL BE INCLUDED. <br />PATCH AS REQUIRED ALL CONSTRUCTIONS TO REMAIN IN ACCORDANCE <br />WITH THE CONTRACT DRAWINGS, WHERE CONTRACTOR IS DESIGNATED <br />TO MAKE REMOVALS. DISPOSITION OF MATERIALS IS THE <br />RESPONSIBILITY OF THE CONTRACTOR. VERIFY WITH OWNER THE <br />DISPOSITION AND REMOVAL OF ANY COMPONENT OF SALVAGEABLE <br />VALUE. <br />2. ALL REMOVALS AND SALVAGE, UNLESS SPECIFICALLY NOTED OR <br />REQUESTED BY THE OWNER SHALL BECOME THE PROPERTY OF THE <br />CONTRACTOR. <br />3. REMOVE ONLY NON —LOAD BEARING CONSTRUCTION OR PARTITIONS, <br />CONTRACTOR TO VERIFY PRIOR TO REMOVAL STRUCTURAL <br />COMPONENTS, I.E. BEARING WALLS, HEADERS ETC. SUPPORTING FLOOR, <br />ROOF OR CEILING JOISTS ARE DESIGNATED FOR REMOVAL, CONTACT <br />THE ARCHITECT/ENGINEER PRIOR TO REMOVAL OF ANY CONSTRUCTION <br />IN QUESTION OR DEBATING FROM THE DESIGN INTENT (U.N.O.). <br />CONTRACTORS NON —CONTACT OF ARCHITECT PRIOR TO REMOVAL OF <br />ANY WORK INDICATES HIS COMPLETE UNDERSTANDING THAT NON —LOAD <br />BEARING OR STRUCTURAL WORK IS BEEN ALTERED UNDER THIS <br />CONTRACT. <br />4. ALL STRUCTURAL SYSTEMS SHALL BE MAINTAINED AND SHALL BE <br />OF SUFFICIENT STRENGTH TO SUPPORT THE DESIGN LOADS AND TO <br />RESIST THE DEFORMATION CAUSED BY SUCH LOADS TO WHICH THEIR <br />SOIL PRESSURE INCLUDING SURCHARGE, HYDROSTATIC HEAD AND <br />IMPACT LOADS AS APPLICABLE. MINIMUM DESIGN LOAD VALUES SHALL <br />BE AS FOLLOWS: <br />100 P.S.F. LIVE LOAD (FIRST FLOOR) <br />20 P.S.F. DEAD LOAD (FLOOR/ROOF) <br />MAXIMUM ALLOWABLE DEFLECTION PER TABLE 1604.3 <br />5. PATCH ALL FINISHES TO MATCH EXISTING, INCLUDING BUT NOT <br />LIMITED TO GYPSUM BOARD, PLASTER, ACOUSTIC SYSTEMS, WOOD TRIM <br />COVERS, BASE, PANEL, RAILS AND WAINSCOT. VERIFY MATCH OF NEW <br />FINISH MATERIALS TO EXISTING IN COLOR, TEXTURE, THICKNESS, CUT, <br />ETC. TO SATISFACTION OF OWNER PRIOR TO INSTALLATIONS, PROVIDE <br />OTHER MATERIALS TO MATCH EXISTING WHEN REQUIRED, TO BE <br />APPROVED BY OWNER. <br />6. PATCH EXISTING WALLS, GYPSUM DRYWALL OR PLASTER TO MATCH <br />EXISTING OF SUFFICIENT THICKNESS TO MAINTAIN UNIFORM WALL <br />THICKNESS. ALL EXPOSED PORTIONS OF WALL SHALL BE FINISHED WITH <br />THREE (3) COATES OF SPECKLING, SANDED AND LEFT IN A PAINT <br />READY CONDITION. <br />7. WHERE APPLICABLE LEVEL ALL EXISTING FLOOR AS REQUIRED TO <br />RECEIVE NEW FLOOR FINISHES. INSTALL REQUIRED TRANSITION PIECES <br />BETWEEN VARIOUS FLOORS FINISHES SUITABLE FOR CONDITIONS AND <br />ACCEPTABLE TO THE OWNER, MATCH EXISTING WHEREVER POSSIBLE. <br />NORTH <br />OWNER: <br />ADAA REAL ESTATE LLC <br />2653 BRUCE B DOWNS BLVD. <br />WESLEY CHAPEL , FL 33544 <br />PROJECT ADDRESS <br />38058 ARBOR RIDGE DRIVE. <br />ZEPHYRHILLS, FL 33540 <br />DRAWING BY: <br />DANIEL JALIL <br />Associate AIA <br />M.A. In Architecture & Planning <br />10233 CELTIC ASH DR. <br />Ruskin, FL 33753 <br />Phone (813) 240-3537 <br />THIS DRAWING MEASURING 24"x36" IS THE PROPERTY OF DANIEL <br />JALIL AND MAY NOT BE USED OR REPRODUCED WITHOUT HIS <br />WRITTEN PERMISSION.. <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE <br />DATE IS SIGNED AND SEALED. <br />ENGINEER: <br />I HEREBY CERTIFY THAT I HAVE <br />REVIEWED THE ATTACHED DESIGN AND <br />FOUND IT TO BE IN COMPLIANCE WITH <br />THE 7TH EDITION OF THE FLORIDA <br />BUILDING CODE 2020. <br />DANIEL JAMES COOREY P.E. <br />FL 77065 <br />Phone (813) 507-9166 <br />DATE ISSUED FOR: <br />SHEET TITLE <br />DEMO PLAN <br />JOB No. ZPH-0821 <br />SCALE AS NOTED <br />DATE AUG-09-21 <br />DRAW BY DJ <br />CHECKED BY DJ <br />PLOT DATE 08-09-21 <br />DRAWING No <br />3"=1'-0" <br />1 1 /2"=1'-0" 3/4"=1'-0" 1 /4"=1'-0" 1 /8"=1'-0" <br />1 0 2 2 0 2 4 8 6 10 20 <br />Al-01 <br />1 /16"=V-0" 12m 0 20 40 <br />