My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38058 Arbor Ridge Dr (3)
Zephyrhills
>
Building Department
>
Building Plans
>
38058 Arbor Ridge Dr (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 9:54:31 AM
Creation date
2/18/2025 3:14:44 PM
Metadata
Fields
Template:
Building Plans
Street #
38058
Location
Arbor Ridge Dr
Contractor
Peace Creek Contracting
Building Plans - Permit #
3035
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 "=10' <br />1 0 i 30 _ 30 20 1� 0 20 40 80 ��_ 15 90 6� 4� 2� _ 0 40 80 120 _ 7 150 ��_ <br />1 =20 1 =30 1 =40 1 =50 1 =100 <br />1 101 300 <br />PROJECT NAME <br />MEDICAL BUILDING <br />MODIFICATIONS <br />I FitJt UKAWINUb t1AJ tfttN L:KtA I tU I' KUM <br />PREVIOUS CONTRACT DOCUMENTS, WHILE <br />ACTUAL CONDITIONS HAVE BEEN INVESTIGATED <br />TO THE BEST OF THE DESIGNER ABILITY, THE <br />CONTRACTOR SHALL FIELD VERIFY THE EXISTING <br />CONDITIONS DURING THE COURSE OF WORK <br />AND COORDINATE ANY DISCREPANCIES WITH <br />THE ARCHITECT/DESIGNER/ENGINEER <br />POWER PLAN <br />SCALE: 1 /4" = 1'— <br />E1-1 <br />PRIUK 10 PA551NG FINAL INbPEU1IUN, 1Ht PHUft551UNAL LLtGIKIGAL <br />CONTRACTOR SHALL PROVIDE EVIDENCE THAT THE LIGHTING CONTROL <br />SYSTEM HAVE BEEN TESTED TO ENSURE THAT CONTROL HARDWARE AND <br />SOFTWARE ARE CALIBRATED, ADJUSTED, PROGRAMMED AND IN PROPER <br />WORKING CONDITION IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS <br />AND MANUFACTURER'S INSTRUCTIONS. FUNCTIONAL TESTING SHALL BE IN <br />ACCORDANCE WITH SECTIONS: <br />C408.3.1.1. OCCUPANT SENSOR CONTROLS <br />C408.3.1.2. TIME —SWITCH CONTROLS <br />C408.3.1.3. DAYLIGHT RESPONSITIVE CONTROLS. <br />1. ALL WORK SHALL BE ACCORDING TO THE NEC 2017 <br />2. ALL EQUIPMENT AND SYMBOLS ARE SHOWN <br />DIAGRAMMATICALLY <br />CONTRACTOR IS RESPONSIBLE FOR CONFIRMING EXACT <br />DIMENSIONS PRIOR CONSTRUCTION. <br />3. LIGHT FIXTURES LABELED WITH A CIRCUIT NUMBER <br />SHALL BE CIRCUITED USING 2#12 & 1#12 GROUND IN <br />3/4" CONDUIT UNLESS NOTED OTHERWISE. CONTRACTOR <br />SHALL CONFIRM AND COORDINATE EXACT JUNCTION BOX <br />AND CONDUIT LOCATIONS AND ROUTING IN FIELD. WHIPS <br />TO LIGHTING FIXTURES SHALL BE ALLOWED TO BE MC <br />CABLE. <br />4. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT <br />DIMENSIONED LOCATION OF RECEPTACLES. <br />5. ALL CIRCUITS SHALL BE CIRCUITED USING 2#12 & <br />1 #12 GROUND IN 3/4" C FOR ONE OR TWO CIRCUITS <br />NUMBERS INDICATED IE* OR ** O.U.N. 120/208V <br />CIRCUITS RUN OVER 100 FT. SHALL USE 2#10 & 1#10 <br />GROUND 3/4"C. <br />6. CONTRACTOR CAN CONSOLIDATE CONDUIT RUNS <br />ACCORDING TO NEC 2017 CHAPTER 9. <br />7. ALL INFORMATION LEFT BLANK ON A PANEL <br />SCHEDULE IS INDICATED ON THE FLOOR PLANS OR <br />ONE —LINE RISERS. ANY CIRCUIT POSITION ON THE <br />PANEL SCHEDULE LEFT BLANK SHOULD BE CONSIDERED <br />A SPARE. ALL PANELS SHALL BE 22KA1C U.O.N. <br />8. PURSUANT THE REQUIREMENTS OF F.A.C. 61G15-33, <br />THE AVAILABLE FAULT CURRENT CALCULATIONS AND <br />VOLTAGE DROP CALCULATIONS ARE ATTACHED. <br />ELECTRIC,4L LEGEND <br />® <br />SPECIAL SERVICES OUTLET <br />110 VOLTS DUPLEX OUTLET <br />110 VOLTS QUADRUPLE OUTLET <br />d6GFI <br />GROUND FAULT INTERRUPT <br />d0p <br />WATER PROOF w/GROUND FAULT <br />j� <br />110 VOLTS SPLIT SWMTM OUTLET <br />220 VOLTS OUTLET <br />TELEPHONE CABLE OUTLET <br />N❑ <br />TV/CABLE OUTLET <br />CBL <br />CABLE OUTLET <br />1 <br />ONE WAY SWITCH <br />12 <br />TWO WAY SWITCH <br />13 <br />THREE WAY SWITCH <br />OCC <br />OCCUPANCY SENSOR <br />1Dm <br />DIMMER SWITCH <br />BATHFAN <br />® <br />CHIMES <br />DISCONNECT SWITCH <br />0 <br />ELECTRICAL PANEL <br />Q <br />DOOR BELL <br />ELECTRIC METER <br />OWNER: <br />ADAA REAL ESTATE LLC <br />2653 BRUCE B DOWNS BLVD. <br />WESLEY CHAPEL , FL 33544 <br />PROJECT ADDRESS <br />38058 ARBOR RIDGE DRIVE. <br />ZEPHYRHILLS, FL 33540 <br />DRAWING BY: <br />DANIEL JALIL <br />Associate AIA <br />M.A. In Architecture & Planning <br />10233 CELTIC ASH DR. <br />Ruskin, FL 33753 <br />Phone (813) 240-3537 <br />THIS DRAWING MEASURING 24"x36" IS THE PROPERTY OF DANIEL <br />JALIL AND MAY NOT BE USED OR REPRODUCED WITHOUT HIS <br />WRITTEN PERMISSION.. <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE <br />DATE IS SIGNED AND SEALED. <br />ENGINEER: <br />I HEREBY CERTIFY THAT I HAVE <br />REVIEWED THE ATTACHED DESIGN AND <br />FOUND IT TO BE IN COMPLIANCE WITH <br />THE 7TH EDITION OF THE FLORIDA <br />BUILDING CODE 2020. <br />DANIEL JAMES COOREY P.E. <br />FL 77065 <br />Phone (813) 507-9166 <br />DATE ISSUED FOR: <br />SHEET TITLE <br />POWER PLAN <br />JOB No. ZPH-0821 <br />SCALE AS NOTED <br />DATE AUG-09-21 <br />DRAW BY DJ <br />CHECKED BY DJ <br />PLOT DATE 08-09-21 <br />DRAWING No <br />3"=1'-0" <br />1 1 /2"=1'-0" 3/4"=1'-0" 1 /4"=1'-0" 1 /8"=1'-0" 1 /16"=1'-0"mommml <br />1 0 2 2 0 2 4 8 6 10 10 12 <br />E1-1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.