Laserfiche WebLink
' LLB' Pit1Ll 11 I I I ' l! <br />AVIATION STORAGE TANK <br />SYSTEMS <br />n <br />REGULATORY REQUIREMENTS: L J '' <br />1. NFPA 101 Life Safe Code `s <br />�' r �� !� REVIEW DATE d <br />2. NFPA 10 Standard for Potable Fire extinguishers CITY OF ZEPHYR LLS <br />g L ti FIRE AND LIFE SAFETY EXAMINE <br />3. NFPA 30 Flammable and Combustible Liquid Code <br />4. NFPA 70 National Electrical Code (NEC) <br />5. NFPA 77 Recommended Practice for Static Electricity <br />6. NFPA 407 Standard for Aircraft Fuel Servicing <br />ALL WORK SHALL COMPLY WITH <br />7. UL 142 Standard for Safety, Steel AST's for Flammable and Combustible Liquids NFFA CODES AND STANDARDS <br />8. UL 842 Standard for Valves for Flammable Fluids <br />9. ANSI/UL 87, Power Operated Dispensing Devises for Petroleum Products <br />10. ANSI/UL 913, Standard for Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II, <br />and III Division 1 Hazardous (Classification) Locations <br />11. American Petroleum Institute (API) Standards. Regulations and Publications, including Appendices for <br />design, cleaning, construction, installation of tanks, piping, and dispensing system <br />12. API Bulletin 1500, 15425 15 81, 2000 <br />13 . API Bulletin 1529 Aviation Hose <br />14. API Bulletin 1540 Design, Construction, Operation, and Maintenance of aviation Fueling Facilities <br />15 . PEI Standards RP-200, RP-100-90, RP-3 00, RP-400, and RP 13 00 <br />16.ATA-103 Standard for Jet Fuel Quality Control at Airports <br />17.Applicable Local, State, and Federal Codes and Regulations <br />18.FAA Advisory Circular 150/5230-4B Aircraft Fuel Storage, Handling, and Dispensing on Airports <br />19.Local and State Dept. of Environmental Management <br />20.Approvals by Authority Having Jurisdiction <br />2 LNIST Handbook 44 (latest Edition) <br />22.OSHA <br />PIPING: <br />1. System Pipe 1.0" and Larger: 304/304L, ASTM A312, SCH10 Stainless steel, flanges 304/304L, <br />150#, RF, ASTM A182 Elbow 90-45, reducers 304/304L, ASTM A403 SCH10 <br />2. System Pipe 1.0" and smaller: 304/304L, ASTM A312, SCH40, Stainless steel fittings 304/304L, <br />ASTM Al82 <br />3. System Instrument Tubing: ASTM A269, grade TP316 stainless .035 wall seamless <br />4. Compression Fittings: DK-LOK 316 stainless steel <br />5. Systems piping shall be cleaned internally before final assembly <br />OPERATION MANUALS: <br />Provide (2) copies of Operation and Maintenance manuals <br />for all equipment including parts list, instruction sheets, and <br />other literature that is provided with systems components <br />SYSTEM PERFORMACE REQUIREMENTS: <br />Minimum Working Pressure Ratings* <br />1. Aboveground Steel Fuel Oil Piping 150 prig <br />2. Vent, Gauge, and Fill Piping: 100 psig <br />3. Fuel Storage Tank: 5 psig <br />4. Fuel Storage Tank, Secondary Containment Shell Walls: 5 psig <br />5. Fuel Control/Operating Valves: 250psi <br />6. Jet Tank Fuel Unloading Rate: 200pgm <br />7. Avgas Tank Fuel Unloading Rate: 200gpm <br />8. Jet Tank Recirculation Rate: 200gpm <br />9. Avgas Tank Recirculation Rate: 200gpm <br />10. Jet Bulkloading Rate: 200gpm <br />11. Avgas Bulkloading Rate: 180gpm <br />12. Avgas Aircraft Dispensing Rate: 18gpm <br />DELIVERY, INSTALLATION AND START-UP: <br />1. Contractor shall provide safe installation of tanks and equipment <br />2. Contractor shall provide qualified service representative to supervise installation, start-up, functional <br />testing, acceptance inspection by Owner and Authority Having Jurisdiction <br />3. Complete System shall be placed into service to complete satisfaction of the owner <br />ABA -CON - <br />AVIATION SERVICES <br />ABA -CON INC. <br />P.O. BOX 308 <br />TITUSVILLE, FL 32781 <br />PHONE: (321) 567-4967 <br />FAX: (321) 607 6805 <br />WEB: <br />www.aba-con.com <br />PROPRIETARY AND CONFIDENTIAL <br />The information contained in this drawing is the sole <br />property of ABA -CON Aviation Services. Any reproducton <br />in part or as a whole is prohibited without written <br />permission of ABA -CON Aviation Services. <br />PROJECT CONTRACTOR: <br />ADAMS TANK & LIFT, INC. <br />4568 131 STAVE NORTH <br />CLEARWATER, FL 33762 <br />V ) <br />W <br />I— <br />O <br />Z <br />W <br />I — <br />DATE: 6/18/2021 <br />_ ------ -- ........ <br />- -- <br />REVISIONS <br />........... <br />DATE 1DESCRIPTION <br />CALE:XX:XX <br />CLIENT: <br />ZEPHYRHILLS <br />MUNICIPAL <br />AFRPORT <br />ZEPHYIRHILLS, <br />FLORIDA <br />DESIGN TEAM TITLE: <br />ADAMS TANK AND LIFT INC. <br />4568 131 ST AVE N <br />CLEARWATER, FL 33762 <br />727-540-0931 <br />NO. <br />DATE <br />REVISION DESCRIPTION <br />This item has been digitally signed and sealed by Soumya Chakrabarti, PE, <br />on date shown. Printed copies of this document are not considered signed <br />and sealed and the signature must be verified on any electronic copies. <br />CHAtK,Q''' <br />* ; No. 66380 ; <br />F <br />:,�0 • 4 D R P F <br />/0 <br />'ram <br />S�J�ti� <br />YA C AKRABARTI <br />FL. REG # 66380 <br />TANK AND P 1 P I N:G <br />PLA14S & DETAILS <br />SITE DESIGNATIONS: <br />FUEL FARM <br />REPLACEMENT <br />SCALE: AS NOTED <br />JOB # 01 <br />DATE: <br />09-23-2021 <br />DESIGNED BY: <br />DRAWN BY: <br />SS <br />FILE NAME: <br />CHECKED BY: <br />DRAWING TITLE: <br />NOTES <br />SHEET NO: <br />TA-1 <br />.i nld <br />