Laserfiche WebLink
�\ / \ '\ /^ ITEM QTY DESCRIPTION PART NUMBER MANUFACTURER <br />GENERAL NOTES —\ / � � � <br />r �I f 1 1 AVGAS TANK 12,000 GALLON, UL-142 DOUBLE WALL, STI-FLAMESHIELD, 120" DIA. 20'-6" LONG, 72" CANOPY UL-142AVGAS DOUBLE <br />GALLON <br />1. CAPACITY 12,000 GALLONS NOMINAL. rl (/'�j� I` g ��\l�/ i \ �' '\28% / \ 45 i /— 7 UL-142 DOUBLE WALL6 1 L+ --��-� \__ f , -� EQUIPMENT DECK AREA WITH SPILL CONTAIMENT OF 150 GALLONS, SLOPED SADDLE SUPPORTS, REAR RUNG MODERN WELDING <br />2. DOUBLE WALL, FLAMESHIELD TYPE I CONSTRUCTION, 360 DEGREE WRAP, UL-142 \�J/ \ i / �'\ LADDER, ONE EACH 24" MANWAY, FOUR ANCHOR POINTS FL -352, E -6 FLORIDA <br />ABA -CO <br />SHOP TEST WITH AIR AT 3 - 5 PSI USE DOUBLE WALL TESTING PROCEDURES 32 ( / / 3 ) 3g J EQ-3sz, EQ-677 <br />' \ '� i �\ /�\ �/ 2 1 EARTH GROUNDING CONNECTION. COPPER BONDED GROUNDING LUG, 5/8" X 2-1/2" LONG 615800 (5/8" X 2.5" ERITECH <br />3. ATTACH TANK LABELS AS FOLLOWS: i /, / \ (MIG-WELDED TO TANK SUPPORT) LONG) AVIATION SERVICES <br />A. "UL-142" \ c �� —J / �\ 37 \) 3 1 VENTTANK3"PRESSUREVACUUM80Z I748A-3400-AV Morrison ABA -CON INC. <br />B. THIS TANK REQUIRES EMERGENCY RELIEF VENTING CAPACITY NOT LESS /� <br />_ Q\� 1 VAPOR RECOVERY ADAPTOR 4x3 323-0100-AA Morrison <br />THAN 392,000 CU. FT./HR. o P.O •BOX 308 <br />, o o , 39 , <br />C. THIS TANK IS PROVIDED WITH AN INTEGRAL STEEL FOUNDATION AND IS \ 22 i ( o C1 =' ..- i' �� 1 VAPOR RECOVERY CAP 323C-0100-AC Morrison INTENDED FOR STATIONARY INSTALLATION ONLY <br />/ 4 z , �_ 8", 8oz/sq.in. EMERGENCY VENT -FLANGED, w/O-RING (PRIMARY & SECONDARY EVENTS TIT 2440E-0100-AV Morrison USV I LLE, FL 32781 <br />'-' � ° `�-- �n , ,;� � <br />��. <br />4. MATERIAL: CARBON STEEL o 35 S 1 3" CAP -IRON BODY BRASS CAP (MANUAL STICK GAUGE OPENING) 178-1200-AC Morrison PHONE: (321) 567-4967 <br />5. ALL NOZZLE COUPLING AND MANWAY BOLTS TO STRADDLE NORMAL ( i o 6 1 INVENTORY /90%ALARM HIGH-LEVEL 25%ALARM LOW LEVEL PROBES EFG-8000 A (EQ-713) Greenleaf Gauge <br />21 — -- �o FAX: 321 607 6805 <br />CENTERLINES OR THEIR PARALLELS, UNLESS OTHERWISE NOTED 15 7 1 ALARM ANNUCIATOR/ DISPLAY 6 DIGIT LCD DIGITAL (90%TANK CAPACITY ALARM) EFG-8000-A (EQ-713) Greenleaf Gauge ( ) <br />6. TANK INTERIOR: BLAST TO SSPC-SP10 LINE USING INTERNATIONAL INTERLINE 850 �� ' %� \� B 1 VALVE,SOLENOID,1/4°, N/O 120VACCOIL, EXPLOSION PROOF, WEATHER TIGHT W/VITON SEALS WEB: <br />f ZC1327BV402INAT JEFFERSON <br />EPDXY PHENOLIC WHITE. o / 1 (ANTI -SIPHON VALVE www.aba-con.com <br />7. TANK EXTERIOR: BLAST TO SSPC-SP-6 EPDXY PRIME USING DEVOE BAR RUST 235. — { 9 1 ADAPTER-3" ALUMINUM (TANK FILL CONNECTION) PART30A PT COUPLING <br />FINISHED PAINT USING INTERNATIONAL DEVTHANE 379UVAALIPHATIC URETHANE /-� <br />/ .... .... .... - �� / 1 DUST CAP-3" LOCKING (TANK FILL CONNECTION LIQUID TIGHT CAP) PART 30VL PT COUPLING PROPRIETARY AND CONFIDENTIAL <br />GLOSS ENAMAL (WHITE 379K1000) 42 , / The information contained in this drawing Is the sole <br />10 1 PUMP (TANK BOTTOM SUMP PUMP <br />"� 19 j HAND P M (T TT M S ) 114000 SHP-10O NUL GPI property of ABA -CON Aviation Services. an re roducton <br />8. SYSTEM TO BE INSTALLED IN ACCORDANCE WITH NFPA 407,30, ATA-103, NEC _. \ ------ - - ----------__----_____—______-_-_-_- _ __-__ ____._____ _____ ._-_____-..__---___-.--__-___-_ __ ___.-_.-_ _ in part or as a whole is prohibited without written <br />\--/ 1 SPR. RETURN 3/4" BALL VALVE STAINLESS (HAND PUMP ANTI SIPHON VALVE N/C) 22-061-41 LANCE permission of ABA -CON Aviation Services. <br />9. EMERGENCY SHUT-OFF TO BE LOCATED AT LEAST 25', BUT NO MORE THAN 100' <br />1 D-RING, STAINLESS STEEL, PRE -CHECK 3896T3 MC MASTER <br />FROM TANK (BY OTHERS) (CONNECT TO ATTENDED LOCATION) — <br />10. APPLICABLE EQUIPMENT SUPPLIED ON THIS TANK IS COMPLIANT WITH FDEP =- n�16J 1 CABLE, CLEAR VINYL COVERED GTP-1093 Gammon PROJECT CONTRACTOR:': <br />APPROVED STORAGE TANK EQUIPMENT LIST (EQ LIST) 1 _ ; 1 VALVE BALL 3/4" STAINLESS, LOCKABLE (MAINTENANCE VALVE) 22-061-11 LANCE <br />11. OVERFILL PREVENTION: \ 1 ADAPTOR-3/4" (NOT SHOWN) (SUMP DISCHARGE) PART 3/4"A PT COUPLING <br />A. WARNING: AT 90% CAPACITY, CLOCK GAUGE (ITEM 6) PROVIDES AN \-� I 1 DUST CAP-3/4" (NOT SHOWN) (SUMP DISCHARGE LIQUID TIGHT CAP) PART3/4"V PT COUPLING ADAMS TANK &LIFT INC. <br />AUDIBLE AND VISUAL ALARM AT ANNUNCIATOR PANEL (ITEM 7). 17� 11 1 INTERSTITIAL MONITORING SENSOR/ INSTALLATION KIT LS60OLDBN-1,SK2-RM1 PNEUMERCATOR ' <br />B. SHUTOFF: AT 95/o CAPACITY, FLOAT VALVE (ITEM 13) CLOSES BONNET ( 12 1 VALVE HIGH LEVEL SHUT-OFF ANGLE VALVE 3"(95%TANK CAPACITY CONTROL VALVE HYDRAULICALLY 4568 131 STAVE NORTH <br />VENT OF HIGH LEVEL SHUTOFF VALVE (ITEM 12) WHICH THEN CLOSES, i OPERATED, DIAPHRAGM -ACTUATED, FAILCLOSED, N/C) z6B1za ocv <br />r �, CLEARWATER FL 33762 <br />PREVENTING FURTHER FUEL INPUT 41� 1� —( 9 1 VALVE POSITION IND. (NOT SHOWN) (VISUAL INDICATOR) 255700 ocv ' <br />12. OVERSPILL PROTECTION: TRANSPORT CONNECTION, PUMP, AND PIPING ARE ALL �` j 1 I i _ �,�% 1 INLINE STRAINER (NOT SHOWN) (PROTECTS SYSTEM FROM SOLID CONTAMINANTS) 660704 ocv <br />WITHIN INTEGRAL EQUIPMENT DECK. APPROXIMATE CAPACITY: 200 GAL, FITTED /'i (23�� JI i , - T = 1 FTG. 3/8 X 3/8 COMP MODIFIED S/S (NOTSHOWN) (CONTROLS OPENING AND CLOSING SPEED of CONTROL <br />WITH NORMALLY CLOSED MANUALLY OPERATED DRAIN VALVE (ITEM 14) (� \ ( \ �. �/ �� �� 20 VALVE) (TAMPER PROOF) 6-6-FBZ-SS Parker <br />13. (ITEM 8) - (ITEM 12)^�\ \ ~ l( - ` 36 �� 1 SPR. OPEN BALL VALVE 1/4" STAINLESS (SYSTEM PRE -CHECK VALVE) 76-501-OIA APOLLO <br />(ITEM 12)THIS VALVE AND EQUIPMENT ARE USED TO SHUT OFF FUEL FLOW AT 95% l 24, 1 D-RING, STAINLESS STEEL, PRE -CHECK 13896T3 MC MASTER <br />TANK CAPACITY. (ITEM #8) IS THE ANTI -SIPHON SOLENOID VALVE THAT PREVENTS `\ ` ' - j JOB NUMBER: <br />\��_`-"-- � 1 .CABLE, CLEAR VINYL COVERED I GTP-1093 Gammon <br />FUEL FROM BEING SIPHONED FROM THE TANK SUCTION PIPING. 24 - - r43)­� <br />\, j� / \ 13 1 95%VALVE & FLOAT (95%TANK CAPACITY MODULATING FLOAT PILOT) 230151 OCV205 <br />THE VALVE OPERATES AS FOLLOWS. THE 1/4" N/O 115VAC SOLENOID VALVE IS j i <br />\ 1 [, / 14 1 VALVE BALL 3/4" BRASS (EQUIPMENT DECK SPILL CONTAINMENT DRAIN VALVE) I XV50OP-12 Parker <br />INSTALLED ABOVE LIQUID LEVEL INTO 3'4"FNPT FITTING WELDED INTO FRONT TANK 1 29 1—��\ ) 26 `� <br />HEAD OPEN TO TANK INTERIOR. THE N/O SOLENOID VALVE BREAKS PUMP �40 ���-� /_�= — ----- -` 1s z 3° WAFER CHECK VALVE, VITON SEAL CV41DSV0300 TITAN DRAWING NUMBER: <br />(SUCTION) BY CREATING A VACUUM LOSS IN THE SUCTION PIPING TO THE PUMP. `,/-------------�- 16 5 VALVE BUTTERFLY 3" VITON 310300-1101038E BRAY <br />THE PUMP IS UNABLE TO PUMP ANY FUEL FROM THE TANK DUE TO LOSS OF PUMP 17 2 VALVE BUTTERFLY 2" VITON ( 310200-1101038E BRAY 21 05-30 <br />SUCTION OR VACUUM, IF THE FILL PIPING OR SHUT OFF VALVES WERE REMOVED EQUIPMENT PLAN 18 1 LINE STRAINER FLANGED 3" I286FDI-3100-AS Morrison <br />OR DAMAGED THE ANTI -SIPHON SOLENOID VALVE WOULD NOT ALLOW FUEL TO / 19 1 PUMP 03c31 B 03C31-B 5.5" IMPELLER GORMAN RUPP <br />EMPTY FROM THE TANK DUE TO LOSS OF VACUUM. THE SOLENOID VALVE IS SCALE: 1:32 _ --; 10 <br />- - \ 1 MOTOR 230V 1-PHASE 5-HP 1800 RPM L5020 BALDOR <br />ALWAYS OPEN UNTIL THE PUMP SWITCH IS ACTIVATED. \30 1 2" CONDUIT f 1 SHEAVE/BUSHING FOR MOTOR AK71H/H-1-1/8" BROWNING <br />1 SHEAVE / BUSHING FOR PUMP AK39H / H-1" BROWNING <br />o\ N ��_ 1 DRIVE BELT A28 BROWNING <br />2 <br />3O i \- O/� \ / 1 COUPLING GUARD ABA -CON ABA -CON <br />3 <br />\ \ I -�, 34 h 20 1 Starter-NEMA 7-9 EXPLOSION PROOF ENCLOSURE WITH Size "1" STARTER MOTOR, KEYED PUMP ON -OFF <br />- 27 SWITCH & (KEYED DEADMAN OVERRIDE SWITCH) 14DUE32HAA4 SEIMENS <br />��� <br />21 1 FILTER VESSEL El 1581, 6TH EDTION FILTER SEPERATOR. CATEGORY-M TYPE-S. HCS-333-1436 FACET <br />(\�5° ii �/ 1 3 O�, 3 CM SERIES COALESCER CARTRIDGES El 1581 6th EDTION CATEGORY-M CM-33S6-5 FACET f <br />.pj� \ 1 36 <br />SM SERIES SEPARATOR CARTRIDGE El 1581 6th EDTION CATEGORY-M SM-436FB-5 FACET `U-1 <br />o n I �-'\ ; � � o / �" � %�^~\ ��-•' 1 i ARMSTRONG MODEL 21AR, AIR VENT, CAST IRON, 208P51 21AR ARMSTRONG � <br />17 3 \) (25 24" MANWAY 1 AIR ELIMINATOR CHECK VALVE 3J4" MNPT (NOT SHOWN) GTP-2916-10 Gammon <br />-- - -- <br />2" CONDUIT ; !16�F� �\ ,\ / / -/ %° i` 1 SPR. RETURN 3/4" BALL VALVE STAINLESS 22-061-41 LANCE <br />\ /� 1 ADAPTOR-3/4" (NOTSHOWN) PART3/4"A PT COUPLING <br />/ \` 1 DUSTCAP-3/4 NOT SHOWN PART34"V PT COUPLING <br />22 J�'" \\ \! 0 � X /� � \��\ ��� 1 VALVE, PRESSURE RELIEF, STEEL 3CRVOOF 75P51 HYDROSEAL <br />Cy <br />1203 / �l� 1 WATER SWITCH FLOAT (NOT SHOWN) LS-5000-SB FPI <br />10 22 1 DIFFERENTIAL PRESSURE GAUGE GTP-534-PB-30A Gammon Q <br />�.\ \• \ / S - --{ 20 ) % - 1 PRESSURE GAUGE 4", LM, 160PSi, L/F, 1/4NPT, SS 9699257 WIKA <br />i <br />1 Z <br />\ 12' MINIMUM \ \ \ \ ! / i i �` -� 3 J 23 1 HOSE REEL,115V, ALUM INTERN TOP RIGHT W/AUX CRANK EP3905-23-12-10FF REELCRAFT <br />/ I 3 COUPLINGVICTAULIC2" (NOTSHOWN) 772" Victaulic <br />\� �� 1 AIRCRAFT FUELING NOZZLE 1 295SAC-0156 DPW fuel Y <br />�I •�\ • � � g; � / � --.�\ �� if ��� � 1 HOSE EI-1529, AVIATION FUELING HOSE, COUPLER MXM, W, CERT SIZE: 1.0" X 75' EAGLE FLIGHT <br />\ / `�� _,\ '(l 24 1 BULK LOADING COUPLER. 2.0" NPT INLET 1712D-AL20 OPW Eng <br />\ J <br />/ \ I L c 1 DUST PLUG 2.5", BULK LOADING COUPLER (NOTSHOWN) PART 25W PT COUPLING <br />1 SECURITY CHAIN STAINLESS, DUST PLUG (NOT SHOWN) S-52 PT COUPLING <br />111��' ( \ <br />�41 f ` ' � �' ! �, � / \ � 1 ;SWIVEL-2" NPT, ALUMINUM 3640-0203 DPW Eng <br />HOSE EI-1529, COUPLER MXM, W/CERT SIZE: 2.0" X 12' EAGLE FLIGHT <br />- - - <br />24 fI \ \ 1 i 25 1 3" ALUMINUM FLOATING & SUCTION ASSEMBLY ABA -CON •' <br />;SWIVEL-3" ALUM FOR SUBMERGE SERVICE (DOUBLE) FLANGED 3640-F10302 DPW ENG. <br />3 5 \ 1 ADAPTER-2" ALUMINUM (FLOATING SUCTION TEST CABLE PORT) PART 20F PT COUPLING <br />--/ 1 DUST CAP-2" LOCKING (FLOATING SUCTION TEST CABLE PORT LIQUID TIGHT CAP) PART 20V1 PT COUPLING <br />26 1 TOTAL CONTROLS (SPA). METER, WITH REGISTER 1/10 USG, 100:1 PULSAR, AIR ELIMINATORJSTRAINER, ( 68215SPA4AT3 TOTAL CONTROL <br />/ O� \ i" �\ '\ �\'\ ---{ 14 f CHECK VALVE (CERTIFIED FOR PUBLIC RESALE) ( 700-7000V20SS <br />BACK ELEVATION 23 )- `4 ��%' _ �_ --� <br />26 2`t J\\-- 27 1 120VAC DEAD MAN / RELAY WATER CONTROL SYSTEM, FLOAT SWITCH, MINI-DEADMAN, 25' COIL CORD STP-1750 3-1 2 1-1-1-3-3-2 Gammon <br />SCALE: 1:60 FRONT ELEVATION'-� 1/ <br />O TOP VIEW 28 1 3" VALVE EXTERNAL EMERGENCY VALVE, FLANGED, 165° FUSIBLE LINK VALVE 346DI-0300 AV Morrison <br />29 1 REEL, GROUND 75' SPR/REWIND HGR-50 17-50 Hannay <br />_ SCALE. 1:60 1 CABLE, CLEAR VINYL COVERED (NOT SHOWN) GTP-1093 Gammon <br />SCALE: 1:100 DATE: 6/1$/2021 <br />- � \j--�\ � -`� � .�\` 1 1 STOP BALL (NOT SHOWN) GTP-1486 Gammon <br />� 34 � ,--�\ 3 <br />{ \ 30 /�^\I (/ \ 1 CABLE STOP BALL CLAMP (NOTSHOWN) GTP-1487 Gammon _-_. <br />11� % 5 ) GTP-1101 Gammon <br />I 1 'CLAMP HEAVY DUTY, AIR FORCE TYPE REVISIONS <br />\ \ I �6 30 1 RIGHT SIDE MOUNTED LADDER J DECK PLATFORM (PAINTED OSHA YELLOW) ABA-SMCW-120 ABA -CON <br />42� 42 \� 17 \ 31 1 GAUGE STICK 12' (NOT SHOWN) (MANUAL GAUGE STICK) 12-Jan BAGBY <br />/ \ i / \� 32 2 VALVE SWING CHECK 3/4" STAINLESS 46635K65 MCMASTER DATE DESCRIPTION. <br />0 34 1 INVENTORY PROBE / INSTALLATION KIT ( B4K2 / PK4-RM1 PNEUMERCATOR <br />\ ; - r-HANGE35 1 20 GALLON ALUMINUM SUMP FUEL RECOVERY UNIT 20G-AL-SR ABA -CON 7/29/2021 j \\ ABE EDDUNLABE UNLABELED PARMISLABELIED TS. FIXED'; <br />VISUAL STYLES. UPDATED DOM <br />{ \ \ �� I �', ! 1 SPR. RETURN 1/2" BALL VALVE STAINLESS (RETURN TO STORAGE VALVE) 22-041-41 LANCE - <br />�� 13� ( 1 S I /� �- I 4 I 1 BALL VALVE 1/2" LOCKABLE STAINLESS (WASTE SUMP VALVE) 122-041-11 LANCE 7/29/2021 %2 '•, TO BUTTERFLY VALVE SWITCHED BYPASS CHECK VALVE <br />\ 3 U ( I 1 VALVE SWING CHECK 3/4„ STAINLESS 46635K65 MCMASTER / <br />^�7\\l ��� I I 36 1 ST-15-115-ELK / 07720 / \ UPDATED BOM. UPDATED <br />120.� /�\ \ ( i /� 2 / ( 0 r 1203 ST-15 SINGLE POINT OVERFILL PREVENTION CONTROLLER, SC-6A SCULCON JUCTION BOX, PLUG &CABLE SCULLY 9/15/2021 3 PLACARDS <br />\ - I I SC-6A / 08156 L \ <br />25 ii it I <br />( 5 �� y I I C 37 1 1" ELECTRICAL POWER CONDUIT STUB <br />10 �\ NONSMOKING JET -A FLAMMABLE J I' NO SMOKING JET -A FLAMMABLE <br />" / u 20 N I I 38 1 3/4" ELECTRICAL POWER CONDUIT STUB <br />/ C I 39 1 1/2" INTRINSICALLY SAFE SHIELDED WIRING CONDUIT STUB - <br />��\ J 3 6 } I I 40 1 SELF -SERVE CONTROL VALVE, TWO STAGE, 1.5"NPT, 115VAC SOLENOID, N/C, W/VITON SEALS, COILS <br />INCLUDED, 304 STAINLESS STEEL BODY 108665 BENNETT <br />-' �� x. \ <br />�{ ( I I� 41 1 TOTAL CONTROLS (SPA). METER WITH VEEDER-ROOT MECHANICAL REGISTER, 1/1 USG 70030SPA2AG TOTAL CONTROLS <br />EtJ <br />SCALE:VARI ES <br />42 1 EXPLOSION PROOF CANOPY LIGHT FIXTURE WITH ON -OFF SWITCH EM1120X2G KILLARK <br />,�, � i I tl I i � 43 1 VALVE, PRESSURE RELIEF, DUCTILE STEEL, 100PS1 078DI-0300 AV Morrison <br />(J ) N J I 45 1 PUMP BY-PASS VALVE, STEEL, 20-40 PSI BV2A BLACKMER C� RAW N BY: <br />n A <br />46 PRODUCT PIPING 1.0" AND LARGER, SCH10 304/304L STAINLESS STEEL, ASTM SA312 USA �'\/I <br />6" 4" 4" 6" r <br />6'_6" 6' �� 47 PRODUCT PIPING 1.0" AND SMALLER, SCH40 304/304L STAINLESS STEEL, ASTM SA312 ( USA <br />26 -6 <br />20'-6" 48 FLANGES 304/304L S/S, 150# RAISED FACE SJO FLANGE, ASTM SA182. ELBOW 90-45 REDUCERS, SCH10 APPROVED BY. <br />LEFT ELEVATION RIGHT E L E VAT I O N 304/304L 5/5, ASTM SA403W PW. FLANGE GASKETS-C4401 1/16" NON -ASBESTOS. BOLTS ASTM A193 GRADE USA <br />Q 5 STAINLESS STEEL. NUTS - HEXAGON ASTM A193 GRADE S. <br />SCALE: 1. 80 SCALE: 1 . V 0 49 INSTRUMENT TUBING: ASTM A269, A35 WALL, 304 STAINLESS. COMPRESSION FITTINGS: DKAOK TUBE USA A <br />FITTINGS 316 STAINLESS STEEL, THREAD TAPE MIL-T 27730A. <br />CLIENT: <br />ZEPHYRHILL3 <br />MUNICIPAL <br />AIRPORT <br />ZEPHYRNILLS, <br />FLORIDA <br />DESIGN TEAM TITLE: <br />• <br />ADAMS TANS( AND LIFT INC. <br />4568 131 ST AVE N <br />CLEARWATER, FL 33762 <br />727-540-0931 <br />NO. <br />DATE <br />REVISION DESCRIPTION <br />This item has been digitally signed and sealed by Soumya Chakrabarti, PE, <br />on date shown. Printed copies of this document are not considered signed <br />and sealed and the signature must be verified on any electronic copies. <br />��11111111111///I <br />U HA Q <br />• <br />�pJ • .......... <br />* ; No. 66380 <br />STATE OF <br />a.�` OR0)P'� <br />'• <br />NM- <br />I� Iry�1�Y\ <br />���J�I <br />SM <br />_ O A CHAKRABARTI <br />FL. REG # 66380 <br />TANK AND PIPING <br />PLANS & DETAILS <br />SITE DESIGNATIONS: <br />FUEL FARM <br />REPLACEMiENT <br />SCALE: AS NOTED <br />JOB # 01 <br />DATE: <br />09-23-2021 <br />DESIGNED BY: <br />DRAWN BY: <br />SS <br />FILE NAME: <br />CHECKED BY: <br />DRAWING TITLE: <br />AVCAW TANK AND <br />EU I PMLNT <br />SHEET NO: <br />TA-3 <br />