Laserfiche WebLink
VICINITY MAP <br />0 <br />GENERAL NOTES <br />I ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH APPLICABLE CODES AND ORDINANCES <br />2 DIMENSIONS SHOWN ON PLANS ARE FROM FACE OF STUDS AND FACE OF MASONRY UNLESS <br />SHOWN OTHERWISE. EXTERIOR WALL DIMENSIONS ARE FROM FACE OF STUD. <br />3 ALL EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY OWNER, CONTRACTOR SHALL FURN15h <br />ALL PLUMBING, MECH, * ELECTRICAL SYSTEMS FOR INSTALLATION OF THIS EQUIPMENT <br />4 COORDINATE ALL APPLIANCE AND PLUMBING FIXTURE OPENINGS WITH CABINETRY. <br />5 VERIFY WINDOW AND DOOR OPENING DIMENSIONS w/ MANUFACTURER SIZES <br />6 DOOR AND WINDOW OPENINGS THAT READ 3080, 20X40, ETC ARE 3'-0" X 8'-0", 2'-0" X 4'-0". ETC. <br />7 CONTRACTOR SHALL POST LOAD CAPACITY SIGN PER LOCAL FIRE MARSHAL <br />8 THE CONTRACTOR SHALL VERIFY ALL CONDITIONS * DIMENSIONS AT THE JOB 51TE PRIOR TO <br />COMMENCING WORK CONTRACTOR SHALL REPORT ALL DISCREPANCIES IN THE DRAWINGS <br />EXISTING CONDITIONS TO THE DESIGNER BEFORE COMMENCEMENT OF WORK. THE DESIGNER'S <br />RESPONSIBILITIES EXTEND ONLY TO CHANGING THE DRAWINGS * UP TO THE VALUE OF SAID <br />DRAWINGS. <br />9 THE CONTRACTOR SHALL SUPPLY, LOCATE * BUILD INTO THE WORK ALL INSERTS, ANCHORS, <br />ANGLES, PLATES, OPENINGS, SLEEVES, HANGERS, SLAB DEPRESSIONS * PITCHES AS MAY BE <br />REQUIRED TO ATTACH * ACCOMMODATE OTHER WORK <br />10 ALL DETAILS * SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL * SHALL BE <br />CONSTRUED TO APPLY TO ANY SIMILAR 51TUATION ELSEWHERE IN THE WORK WHERE A DIFFERENT <br />DETAIL 15 SHOWN. <br />11 DEVIATIONS FROM THESE DRAWINGS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND OWNER. <br />MODIFICATIONS OF STRUCTURAL DETAILS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL <br />PRIOR TO PROCEEDING WITH THE MODIFICATION. ALL CHANGES TO STRUCTURAL DETAILS <br />CONSTRUCTED WITHOUT PRIOR APPROVAL OF THE ENGINEER ARE AT THE CONTRACTOR'S AND <br />OWNER'S RISK <br />12 IT 15 THE INTENT OF THE DESIGNER THAT THIS WORK BE IN CONFORMANCE w/ ALL REQUIREMENTS <br />OF THE AUTHORITIES HAVING JURISDICTION OVER THI5 TYPE OF CONSTRUCTION $ OCCUPANCY. <br />ALL CONTRACTORS SHALL DO THEIR WORKING IN CONFORMANCE w/ ALL APPLICABLE CODES <br />REGULATIONS. <br />FLORIDA PRODUCT APPROVAL SCHEDULE <br />PRODUCT CATAGORY <br />MANUFACTURER <br />FLORIDA PRODUCT APPROVAL NUMBER <br />DOORS * WINDOWS <br />SEE CONTRACTORS SCHEDULE FOR FLORIDA PRODUCT APPROVAL NUMBER <br />UNDERLAYMENTS/ PEEL <br />POLYGLA55 USA <br />FL 5259 <br />SEAL MEMBRANE <br />WOOD CONNECTORS <br />51MP50N STRONG TIE <br />FL 9589, 10007, 10441, 10446, 10447, 10456, 10531, <br />10667, 10860, 10866, 11468, 11473, 11496, 13872, <br />13975 <br />CONCRETE LINTEL <br />CAST CRETE <br />FL 158.1, FL 158.2 <br />ROOFING/ SHINGLES <br />GAF <br />FL 10124, FL 31588, FL 33750 <br />ROOFING/SINGLE PLY ROOF <br />GAF <br />FL 10124, FL 31588, FL 30780 <br />SYSTEMS <br />ROOFING/BITUMEN ROOF <br />GAF <br />FL 10124, FL 31585, FL 39780 <br />SYSTEM <br />ROOFING/ <br />TAMKO BUILDING PRODUCTS <br />FL 3901 <br />NON-STRUCTURAL METAL <br />ROOFING <br />ROOFING/ VENTILATORS <br />LOMANCO <br />FL 2547, FL 3595, FL 3792, FL 3793, FL 3794, F <br />15696 FL 1202 FL 28 5 FL 29284 <br />7 47 , <br />PANEL WALL/ SOFFITS <br />KAYCAN LTD. <br />FL 39778, FL 39367, FL 16503, FL 24564 <br />PANEL WALL/ SIDING <br />LP BUILDING PRODUCTS <br />FL 9190, FL 38694 <br />PANEL WALLS/SIDING <br />JAMES HARDIE PRODUCTS <br />FL 10477, FL 13192, FL 13223, FL 13265, FL 19901, <br />FL 32103 <br />NOTE: IT 15 THE CONTRACTORS RESPONSIBILITY TO REVIEW ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. FOR <br />15 RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THI5 PROJECT ONLY. ANY DISCREPANCY BETWEEN FIELD <br />CONDITIONS, OTHER DESIGN PROFE5510NAL5SHOP DRAWINGS, CONTRACTORS' BUILDING METHODS, AND <br />THESE SIGNED AND SEALED DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF ALLTECh STRUCTURAL <br />ENGINEERING, INC. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. <br />O <br />h <br />ELEVATION <br />G <br />WALL PRE55URE ZONES <br />(150V IO VIEW) <br />O <br />h <br />ELEVATION <br />n c i, <br />0 <br />GABLE FLAT ROOFS Oa° <br />01 OO IOO <br />f---------�-- <br />O <br />- -r--------- <br />OO <br />I <br />OO <br />-- <br />GABLE <br />FLAT <br />ROOF5 <br />i <br />I <br />; <br />71<0<451 <br />=Ko7 <br />L <br />M tSJI V \� <br />a = Width of Edge 5trlp <br />hip ROOF <br />7°<©<45° <br />ROOF PRE55URE ZONES <br />(PLAN VIEW) <br />FLORIDA STRUCTURAL DESIGN <br />CRITERIA <br />(FBCR — 2020 7TH <br />EDITION) <br />GABLE B - 2/12-4/12 <br />ROOF 5LOPE(7-20 DEGREES) <br />= Vult <br />40 P5F <br />ZONE I, 16.95 -42.00 <br />FLOOR LIVE LOAD <br />80 P5F <br />CORRIDO ZONE 2n, 16.95 -61.20 <br />R5 2 r, 3 e = <br />ROOF LIVE LOAD <br />20 P5F ZONE 3r= 16.95 -72.80 <br />ROOF DEAD LIVE LOAD <br />10 P5F <br />WIND LOAD: <br />WIND50KNE DEBRIS AREA <br />YES <br />WALL: <br />I WIND SPEED= <br />145 MPH <br />ZONE 4 = 22.75 -24.60 <br />Vult <br />2 RI5K CATEGORY: <br />II <br />ZONE 5 = 22.75 -30.40 <br />3 WIND EXPOSURE <br />B <br />GARAGE DOORS: <br />CATEGORY <br />4 ENCLOSURE <br />ENCLOSED <br />9'X7 19.9 -22.50 <br />CLASSIFICATION: <br />INTERNAL PRESSURE <br />±0.18 <br />16'X7 19.5 -21.2 <br />COEFFICIENT= <br />5 COMPONENT * CLADDING <br />END ZONE WIDTH =a= 41 <br />FOR ROOF ANGLE= <br />(>7 TO <br />20°) <br />H=0 TO 30 FEET <br />HEIGHT * EXPOSURE ADJUSTMENT <br />COEFFICIENT = 1.0011 <br />(DESIGN PRESSURE P5F*) 501L BEARING PRESSURE: 1,500 P5F <br />(ASSUMED) <br />FRAMING N OTE5 <br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH -INS MUST BE <br />COMPLETE, INSPECTED AND APPROVED BEFORE REQUESTING THE <br />FRAMING INSPECTION <br />FOUNDATION NOTE <br />1) A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE <br />SURVEY SHALL BE ON THE 51DE FOR THE BUILDING INSPECTORS USE OR <br />ALL PROPERTY MARKERS SHALL BE EXPOSED AND A STRING STRETCHED <br />FROM MARKER TO MARKER TO VERIFY REQUIRED SETBACKS <br />GARAGES AND CARPORTS <br />OPEING PROTECTION <br />OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES <br />SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE <br />EQUIPPED WITH 50LID WOOD DOORS NOT LE55 THAN 1-3/5" (35mm) IN THICKNESS, SOLID <br />HONEYCOMB CORE STEEL DOORS NOT LE55 THAN 1-3/5" (35mm) IN THICK, OR 20 MINUTE <br />FORE=RATED DOORS w/ SELF CLOSURE DEVICE <br />DUCT PENETRATION <br />DUCT PENETRATION <br />DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILING SEPARATING THE <br />DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 mm) <br />SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. <br />SEPARATION REQUIRED <br />THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LESS THAN <br />1/2" (12.7mm) GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE <br />ROOMS SHALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LE55 THAN 5/8" <br />(15.9mm) TYPE "X" GYPSUM BOARD OR EQUIVALENT, WHERE THE SEPARATION 15 A FLOOR -CEILING <br />ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL BE PROTECTED BY NOT LE55 <br />THAN 1/2" (12.7mm) GYPSUM BOARD OR EQUIVALENT. <br />SURFACE <br />GARAGE FLOOR SURFACES SHALL BE APPROVED NONCOMBUSTIBLE MATERIAL. <br />THE AREA OR FLOOR USED FOR PARKING OF AUTOMOBILES OR OTHER VEHICLES SHALL BE <br />SLOPED TO FACILITATE THE MOVEMENT OF FLUIDS TO A DRAIN OR TOWARD THE MAIN VEHICLE <br />ENTRY DOORWAY, <br />FLOOD HAZARD AREAS <br />RESERVED <br />AUTOMATIC GARAGE DOOR OPENERS <br />AUTOMATIC GARAGE DOOR OPENERS, IF PROVIDED SHALL BE LISTED IN ACCORDANCE WITH <br />UL325 <br />ENCLOSED STRUCTURE NOTES <br />IN LIEU OF IMPACT WINDOWS OR AN APPROVED SHUTTER SYSTEM, A PLYWOOD PANEL MUST BE MADE <br />FOR EACH NEW WINDOW AND STORED ON SITE, <br />THE PLYWOOD PANEL SHALL CONFORM TO THE FOLLOWING MINIMUM REQUIREMENTS: <br />MINIMUM THICKNESS: 7/16" <br />MAXIMUM SPAN: 8' <br />PANELS SHALL BE PRECUT TO COVER THE GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED <br />AND MARKED W/ DESIGNATION FOR EACH WINDOW <br />2 1/2" #8 WOOD SCREWS WITH A MAXIMUM SPACING OF 16" FOR <br />LE55 THAN 4' PANEL, 10" FOR LE55 THAN 0 SPAN AND 8" FOR <br />LE55 THAN 8' SPAN <br />WHERE 5CREW5 ARE ATTACHED TO MASONRY OR MASONRY/STUCCO, THEY SHALL BE ATTACHED <br />U51NG VI5RATION-RE515TANT ANCHORS HAVING A MINIMUM WITHDRAWAL CAPACITY OF 1500 LB. <br />SUCH AS THE 51MP50N DM5A37 MACHINE SCREW ANCHOR <br />DOORS MUST BE EQUALLY PROTECTED UNLESS ENGINEERED FOR WIND LOADS, INCLUDING FRENCH <br />DOORS. <br />TERMITE TREATMENT SOIL CHEMICAL BARRIER <br />METHOD <br />Notice of termite protection. A permanent Sign which Identifies the termite treatment provider <br />and need for rein5pectlon and treatment contract renewal shall be provided. The sign shall be <br />posted near the water heater or electric panel. Protection against decay and termites. <br />Condensate lines and roof downspouts shall dl5charge at least I foot (305 mm) away from the <br />structure 5idewall, whether by under ground piping, tail extCn51on5, or splash blocks. Gutters with <br />downspouts are required on all buildings with eaves of less than 6 inches (152 mm) horizontal <br />projection except for end rakes or on a roof above another roof. gable <br />R318.1 Termite protection. Termite protection shall be provided by registered termltICICe5, mcludmg soil applied <br />pe5ticlde5, baiting systems, and pesticides applied to wood, or other approved methods of termite protection labeled for <br />use a5 a preventative treatment to new construction. See Section 202, Reg5tered Termiticlde. Upon completion of the <br />application of the termite protective treatment, a certificate of compliance shall be I55ued to the building department by <br />the licensed pest control company that contam5 the following statement: "The bullring has received a complete treatment <br />for the prevention of subterranean termites. Treatment 15 in accordance with rules and laws e5tabll5hed by the Florida <br />Department of Agriculture and Consumer Services." <br />R318.1.1 if 5011 treatment 15 used for subterranean termite prevention, the initial chemical soil <br />treatment inside the foundation perimeter shall be done after all excavation, backfilling and <br />compaction 15 complete. <br />R318.1.2 If 5011 treatment 15 used for Subterranean termite prevention, 5011 area d15turbed after <br />initial chemical 5011 treatment shall be retreated with a chemical 5011 treatment, Including spaces <br />boxed or formed. <br />R318.1.3 If soil treatment 15 used for Subterranean termite prevention, space in concrete floors <br />boxed out or formed for the subsequent installation of plumbing traps, drains or any other <br />purpo5e Shall be created by L151ng plastic or metal permanently placed forms of sufficient depth <br />to eliminate any planned soil disturbance after initial chemical 5011 treatment. <br />R318.1.4 If 5011 treatment 15 used for subterranean termite prevention, chemically treated 5011 shall <br />be protected with a minimum 6 millimeter vapor retarder to protect against rainfall dilution. If <br />rainfall occurs before vapor retarder placement, retreatment 15 required. Any work, including <br />placement of reinforcing steel, done after chemical treatment until the concrete floor 15 poured, <br />shall be done In such manner a5 to avoid penetrating or disturbing treated 5011. <br />R318.1.5 If soil treatment 15 used for subterranean termite prevention, concrete overpour or <br />mortar accumulated along the exterior foundation perimeter shall be removed prior to exterior <br />chemical 5011 treatment, to enhance vertical penetration of the chemicals. <br />R318.1.6 If 5011 treatment 15 used for Subterranean termite prevention, chemical soil treatments <br />shall also be applied under all exterior concrete or grade within I foot (305 mm) of the primary <br />ucture 5idewaII5. Also a vertical chemical barrier shall be applied promptly after construction str I c pp p p y 15 <br />completed, including initial Iand5caping and irrigation/sprinkler installation. Any soil dl5turbed after <br />the chemical vertical barrier 15 applied 5hall be promptly retreated. <br />R316.1.7 If a regl5tered termiticide formulated and regl5tered a5 a bait system 15 used for <br />subterranean termite prevention, 5ectlon5 R318.1.1 through R318.1.6 do not apply; however, a <br />Signed contract assuring the Installation, maintenance and monitoring of the baiting system for a <br />minimum of five years from the 155ue of the certificate of occupancy shall be provided to the <br />building official prior to the pouring of the slab, and the system must be installed prior to final <br />building approval. If the baiting system directions for use require a monitoring phase prior to <br />installation of the pesticide active ingredient, the installation of the monitoring phase components <br />shall be deemed to constitute installation of the system. <br />R318.1.8 If a registered termiticide formulated and registered a5 a wood treatment 15 used for <br />subterranean termite prevention, Section5 R318.1.1 through R318.1.6 do not apply. Application of the <br />wood treatment termiticide shall be a5 required by label direction5 for use, and must be <br />completed prior to final building approval. R318.2 Penetration. Protective sleeves around metallic <br />piping penetrating concrete slab -on -grade floors shall not be of cellulose -containing materials and, <br />If 5011 treatment 15 used for subterranean termite protection, shall receive application of a <br />termiticide in annular space between sleeve and pipe. <br />BUILDING CODES <br />2020 FLORIDA BUILDING CODE, 7th EDITION, RESIDENTIAL <br />2020 FLORIDA BUILDING CODE, 7th EDITION, BUILDING <br />2020 FLORIDA BUILDING CODE, 7th EDITION, ENERGY <br />2020 FLORIDA BUILDING CODE, 7th EDITION, TEST PROTOCAL <br />2020 FLORIDA BUILDING CODE, 7th EDITION, PLUMBING <br />2020 FLORIDA BUILDING CODE, 7th EDITION, MECHANICAL <br />2020 FLORIDA BUILDING CODE, 7th EDITION, EXISTING BUILDING <br />2020 FLORIDA BUILDING CODE, 7th EDITION, FUEL GAS <br />2020 FLORIDA BUILDING CODE, 7th EDITION, ACCE551BILITY <br />2020 FLORIDA FIRE PREVENTION CODE <br />NEC 2017 NATIONAL ELECTRICAL CODE-NFPA 70 FAIR HOUSING GUIIDLINE5 <br />TO THE BEST OF THIS DESIGNER'S KNOWLEDGE, ENCL05ED PLANS AND SPECIFICATIONS COMPLY WITH <br />THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE MINIMUM FIRE SAFETY STANDARDS <br />AS DETERMINED IN ACCORDANCE WITH CHAPTERS 553 AND 633, LAWS OF FLORIDA. <br />PROTECTION OF OPEN I NG5 <br />WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7/16" (II mm) AND A MAXIMUM SPAN OF 8' <br />(2438 mm) SHALL BE PERMITTED FOR OPENING PROTECTION IN ONE -AND TWO-STORY BUILDINGS. <br />PANELS SHALL BE PRECUT AND ATTACHED TO THE FRAMING SURROUNDING THE OPENING CONTAINING <br />THE PRODUCT WITH THE GLAZED OPENING. PANELS SHALL BE PREDRILLED AS REQUIRED FOR THE <br />ANCHORAGE METHOD AND SHALL BE SECURED WITH THE ATTACHMENT HARDWARE PROVIDED. <br />ATTACHMENTS SHALL BE DESIGNED TO RESIST THE COMPONENT AND CLADDING LOADS DETERMINED <br />IN ACCORDANCE WITH EITHER TABLE R301.1(2) OR A5CE7, WITH THE PERMANENT <br />CORROSION -RESISTANT ATTACHMENT HARDWARE PROVIDED AND ANCHORS PERMANENTLY INSTALLED <br />ON THE BUILDING. ATTACHMENT IN ACCORDANCE WITH TABLE R301.2.1,2 15 PERMITTED FOR BUILDINGS <br />WITH A MEAN ROOF HEIGHT OF 33" (10058mm) OR LE55 WHERE Vult DETERMINED IN ACCORDANCE <br />WITH SECTION R301.2.1.3 DOES NOT EXCEED 130 MILES PER HOUR (58m/5) <br />Table R301.2.1.2 Windborne Debris Protection Fastening Schedule for Wood Structural Panels, Reserved. <br />FA5TNER SPACING (INCHES) <br />FA5TNER TYPE PANEL SPAN <_ 4 PANEL SPAN <_ 6 PANEL 5PAN <_ 8 FEET <br />FEET FEET <br />NO 8 WOOD SCREW BASED 16 10 8 <br />ANCHOR WITH 2" <br />EMBEDMENT LENGTH <br />NO 10 WOOD SCREW BASED 16 12 9 <br />ANCHOR WITH 2" <br />EMBEDMENT LENGTH <br />NO 1/4" LAG SCREW BASED 16 IG 16 <br />ANCHOR WITH 2" <br />EMBEDMENT LENGTH <br />FOR 51: 1" = 25.4 mm, I' = 304.8 mm, I POUND = 4.448N, I MILE PER HOUR = 0.447 m/5 <br />a. THIS TABLE 15 BASED ON Vult AS DETERMINED IN ACCORDANCE WITH SECTION R301.2.1.3, OF 130 <br />MPH AND A 33' MEAN ROOF HEIGHT. <br />b.FA5TENER5 SHALL BE INSTALLED AT OPPOSING ENDS OF THE WOOD STRUCTURAL PANEL. FA5TENER5 <br />SHALL BE LOCATED A MINIMUM OF I" FROM THE EDGE OF THE PANEL. <br />c. ANCHORS SHALL PENETRATE THROUGH THE EXTERIOR WALL COVERING WITH AN EMBEDMENT LENGTH <br />OF 2 INCHES MINIMUM INTO THE BUILDING FRAME. FASTENERS SHALL BE LOCATED A MINIMUM OF <br />2-1/21NCHE5 FROM THE EDGE OF CONCRETE BLOCK OR CONCRETE. <br />d. WHERE PANELS ARE ATTACHED TO MA50NRY/5TUCCO, THEY SHALL BE ATTACHED U51NG <br />VI15RATION-RE515TNAT ANCHORS HAVING A MINIMUM ULTIMATE WITHDRAWAL CAPACITY OF 1500 <br />POUNDS. <br />REQUIRED SAFETY GLAZING IN HAZARDOUS <br />LOCATIONS <br />R308.4 hazardous locations. The following 5hall be considered Specific hazardous locations requiring safety <br />glazing materials: <br />I. Glazing in swinging doors except jalou5ie5 <br />2. Glazing in fixed and sliding pane15 of 5liding door a55embIle5 and pane15 in sliding and blfold closet door <br />a55embIle5. <br />3. Glazing in Storm doors. <br />4. Glazing in unframed 5winging doors. <br />5. Glazing in doors and enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs and showers. <br />Glazing In any portion of a building wall enclosing these compartments where the bottom exposed edge <br />of the glazing 15 less than 60 Inches (1524 min) above a standing surface. <br />G. Glazing in an Individual fixed or operable panel adjacent to a door where the nearest exposed edge of <br />the glazing 15 within a 24-inch (610 mm) arc of either vertical edge of the door <br />in a closed F051tion and where the bottom exposed edge of the glazing 15 less than 60 inches (1524 <br />mm) above the walking surface. <br />7. Glazing in an Individual fixed or operable panel, other than in those locations described in preceding Items <br />5 and 6, which meets all of the following condition: <br />7.1 Exposed area of an Individual pane greater than 9 square feet; <br />7.2 Exposed bottom edge 1e55 than 18 inches above the floor; <br />7.3 Exposed top edge greater than 36 inches above the floor; and <br />7.4 One or more walking 5urface(5) within 36 inches horizontally of the plane of the glazing. <br />8. Glazing in guards and railings, including structural baluster panels and nonstructural In -fill panels, <br />regardless of area or height above a walking surface. <br />9. Glazing in wa115 and fences enclosing indoor and outdoor swimming pools, hot tubs and 5pa5 where all of <br />the following conditions are present: <br />9.1 The bottom edge of the glazing on the pool or spa 51de 15 Ie55 than 60 inches above a walking <br />surface on the pool or spa 51de of the glazing; and <br />9.2 The glazing 15 within 60 inches horizontally of the water'5 edge of a swimming pool or spa. <br />IO.Glazing adjacent to stairways, landings and ramps within 36 mche5 horizontally of a walking surface; when <br />the exposed 5urface of the glass 15 less than 60 inche5 above the plane <br />of the adjacent walking surface. <br />II.Glazing adjacent to stairways within 60 inche5 horizontally of the bottom tread of a stairway in any <br />direction when the exposed surface of the glass 15 less than 60 inches above the nose of the tread. <br />SCOPE OF WORK <br />NEW CONSTRUCTION <br />BUILDING CODE <br />REQ U I REM ENT5 <br />ALL WORK MATERIALS * INSTALLATION SHALL BE IN <br />STRICT ACCORDANCE WITH ALL EXTANT ORDINANCES, <br />STATE * LOCAL BUILDING CODES, OSHA REGULATIONS <br />* CODES IN FORCE BY REFERENCE, LATEST ADOPTED <br />EDITIONS. THESE DRAWINGS ARE DONE IN COMPLIANCE <br />TO THE 2020 FLORIDA BUILDING CODES, 7th EDITION. <br />DIMEN510NING METHOD <br />WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER <br />SCALED DIMENSIONS. ELEVATION OF FLOOR HEIGHTS <br />ARE TO THE PRIMARY FINISHED FLOOR LINE. EXTERIOR <br />DIMENSIONS ARE TO OUTER EDGE OF MASONRY BLOCK <br />OR OUTER EDGE OF FRAMING SHEATHING. <br />DISCREPANCIES <br />DISCLOSURE <br />CONTRACTOR SHALL CHECK AND VERIFY ALL <br />DIMENSIONS AND COORDINATE CONDITIONS IN THE <br />FIELD. ALL DISCREPANCIES AND CONFLICTS SHALL BE <br />REPORTED TO THE DESIGNER OF RECORD IN WRITING <br />PRIOR TO PROCEEDING OR CONTINUING WITH <br />CONSTRUCTION. UNREPORTED DISCREPANCIES AND <br />CONFLICTS REMAIN RESPONSIBILITY OF THE <br />CONTRACTOR. <br />COPYRIGHT STATEMENT <br />ONTWERPE STUDIO, LLC HEREBY EXPRESSLY RESERVES <br />ITS COPYRIGHT AND OTHER RIGHTS IN THESE PLANS. <br />THIS SET OF DRAWINGS 15 NOT TO BE REPRODUCED, <br />CHANGED, OR COPIED IN ANY FORM OR MANNER <br />WHATSOEVER WITHOUT FIRST OBTAINING WRITTEN <br />PERMISSION AND CONSENT IN WRITING OF ONTWERPE <br />STUDIO. LLC, 42 BRADFORD STREET, NORTH <br />CAROLIONA, NC 28358. <br />AREA TABULATION (5 F) <br />ELEVATION A * B SPACE <br />PROPOSED <br />DETACHED GARAGE 728 <br />TOTAL 5F 728 <br />PAGE INDEX <br />GLO <br />PROJECT INFORMATION <br />CLO <br />ARCHITECTURAL SITE PLAN <br />ALO <br />FLOOR PLAN * NOTES, ELEVATIONS <br />E1.0 <br />ELECTRICAL PLAN, NOTES t DETAILS <br />FOUNDATION PLANS, ROOF FRAMING PLANS <br />51.0 <br />* NOTES <br />5D1.0 <br />PERTINENT PROJECT STRUCTURAL NOTES <br />5D2.0 <br />PERTINENT PROJECT STRUCTURAL NOTES <br />U JUDITH ANN KOEHN, CPBD, AIBD <br />j AKOHN@ONTWERPE5TUDIO.COM <br />-' 727.490.94591 910,374.7663 <br />p WWW.ONTWERPE5TUDIO.COM <br />to <br />z <br />toLU N•C•B•D•C <br />Q i NATIONAL COUNCIL OF • <br />11 <br />�c A o, <br />�FP P 4 <br />Judith Ann Koehn <br />CERTIFICATION NO. 10.257 <br />MEMBER <br />Creating where people liveA I <br />B D <br />AMERTCAv L\BTITIITE of <br />BUILDING DESIG <br />2 <br />N <br />1� <br />u J <br />O (n <br />O m <br />J <br />F — <br />O Q <br />O _-) <br />O O <br />C) J <br />W � <br />Q <br />m = <br />L� Iry <br />D_ <br />LJ <br />N <br />aau11ny8. <br />E: �-..., <br />.......... <br />Kelly <br />E. <br />NO 56191 <br />-; STA E OF 1uQ� <br />Lyons <br />�. <br />O q 10 P G��,: <br />2022*05, <br />This item has been <br />electronically signed and <br />sealed by Kelly E. Lyons PE2 <br />using a Digital Signature and <br />date. <br />J{ <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />13:07:36 <br />• <br />signature must be verified on <br />any electronic copies, <br />,__ <br />-04' <br />00' <br />0 <br />Ao N O <br />zoo W0A F <br />� UOM <br />'� Q <br />M F7 <br />> W <br />C7 W�aCM0AO�Z <br />O0 <br />0-t A <br />U-- <br />,� t <br />O AOw �� �a <br />I�HU� ¢ <br />�- <br />�•, <br />1nALL OACoo SF 14pNATI®NRIDA9�DLY A rn <br />UAL rRL�AND THC CODE, o®RDINANdj� '0F6PNRI1LLiSFz <br />r <br />w a <br />0 <br />0 <br />REVIEW <br />CITY fps U <br />OPZEP N <br />��� EXAMINER <br />I ai ZW `mil w � � x <br />R W W � t�---1 0., c� F-� a <br />REV DATE DESCRIPTION <br />z <br />3 <br />PROJECT NO: 2204-256 <br />DATE: 23.05,2022 <br />DRAWN BY: A. KOHN <br />*CONSTRUCTION DOCUMENTS ARE ORIGINAL <br />AND UNPUBLISHED MATERIALS OF THE <br />DESIGNEP, THEY SHALL NOT BE COPIED IN <br />ANY FORM WITHOUT THE EXPRESSED <br />WRITTEN CONSENT OF THE DESIGNER. <br />PROJECT DATA <br />5/23/2022 12:25:43 PM <br />T i_F_F_T_ 11 0 7 1 -- <br />7 i iLf TTi --f i —� <br />GLO <br />