GENERAL NOTES: <br />THIS BUILDING HAS .BEEN DESIGNED TO CONFORM TO THE 2001 FLORIDA BUILDING CODE SOIL TERMITE TREATMENT: <br />AND 2009 SUPPLEMENTS <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES <br />T,L HANSON t ASSOCIATES A REGISTERED LICENSED, FLORIDA PROFESSIONAL APPLIED TO SOIL, OR WOOD, BATING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR <br />ENGINEERING COMPANY, HAS APPLIED " RATIONAL ANALYSIS" FOR THE STRUCTURAL USE AS PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. <br />DESIGN OF THIS STRUCTURE A CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED <br />THE BUILDING ( INCLUDING ALL COMPONENTS AND CLADDINGS SHALL BE DESIGNED FOR THE PEST CONTROL COMPANY BEFORE A " CERTIFICATE OF OCCUPANCY WILL BE ISSUED. THE CERTIFICATE <br />FOLLOWING SUPERIMPOSED LOADS SHALL STATE, (PER FBC R320.1) <br />FLOORS: <br />LIVE LOADS - 40 P.S.F. <br />DEAD LOADS - 10 P.S.F. <br />C1_ <br />-.. <br />LIVE LOADS - 50 P.S.F. <br />DEAD LOADS - 10 P,S,F, <br />LIVE LOADS - 16 P.S.F. <br />DEAD LOADS - 10 P.S.F, <br />WIND DESIGN ASSUMPTIONS: <br />WIND SPEED 120 MPH <br />BUILDING EXPOSURE - B <br />BUILDING IMPORTANCE FACTOR ■ 1.0 <br />MEAN ROOF HEIGHT 30' OR LESS <br />HEIGHT t EXPOSURE AO"TMENTS COEFFICIENT . 1,o <br />ENCLOSED BUILDING <br />INTERNAL PRESSURE COEFFICIENT • + / - 0.18 <br />COMPONETS t CLADDING PSF ROOF • 14,9/-50,1 WALL ■ 23,9/-34,1 <br />OVER HANG ■ -81.2 <br />SOIL BEARING 4 COMPACTION: <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF <br />2000 P.S.F.( MINIMUM ) THE CONTRACTOR/PROPERTY OWNER IS RESPONSIBLE FOR VERIFYING <br />THAT THE SOIL ON THE SITE 16 PROPERLY PREPARED AND COMPACTED SUCH THAT IT CAN <br />SUPPORT A 2000 P.S.F. FOUNDATION LOADING <br />T,L. HANSON i ASSOCIATES A REGISTERED LICENSED FLORIDA PROFESSIONAL <br />ENGINEERING COMPANY: DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION <br />SITE NOR PERFORMING ANY SOIL TESTING <br />T,L HANSON 4 ASSOCIATES SHALL NOT BE RESPONSIBLE FOR THE SITE SOIL ABILITY TO SUPPORT <br />THE BUILDING LOADS <br />FOUNDATION 4 SLAB - ON- GRADE NOTES : <br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS,. <br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED <br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2000 P.S.F. FOUNDATION LOADING. SLAB <br />SHALL BE PLACE OVER A 6 MIL VAPOR BARRIER ON CLEAN ADEQUATELY COMPACTED <br />AND TERMITE POISONED SOIL <br />CONCRETE UTILIZED IN THE FOUNDATION AND SLABS SHALL HAVE A MINIMUM 28 DAY <br />COMPRESSIVE STRENGTH OF 3000 P.S.F. <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTM A -615, LAP SPLICES, WHERE REQUIRED SHALL BE A MINIMUM OF 25" FOR <br />es REBAR , 30" FOR •6 REBAR t 35" FOR sl REBAR <br />PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES ( AFTER <br />FINAL SITE GRADING) THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE <br />EXACT STEMWALL HEIGHT BASE UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION <br />AND CONTACT ENGINEER WHEN MORE THAN 4 COURSE ARE REQUIRED <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON SITE <br />FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND A <br />STRING STRECTED FROM MARKER TO MARKER TO VERIFY REQUIRED SET BACKS <br />THE CLIENT UNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE <br />AGREES TO HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOSSES AND <br />EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT OF OR RESULTING FROM THE <br />PROJECT. THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION <br />DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR COST OF <br />REPAIRS OR DELAY TO THE CONSTRUCTION <br />THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. THE TREATMENT IS INACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA DEPARTMENT <br />OF AGRICULTURE AND CONSUMERS SERVICES <br />IF A REGISTERED TERMITICIDE BAIT SYSTEM IS TO BE USED FOR SUBTERRANEAN TERMITE PREVENTION <br />SECTION R320.1 THROUGH R320,1.6 DO NOT APPLY. A SIGNED FIVER EYAR CONTRACT FROM THE ISSUE <br />OF THE CERTIFICATE OF OCCUPANCY ASSURING INSTALLATION. MAINTENANCE AND MONITORING OF THE <br />BAITING SYSTEM SHALL BE PROVIDED TO THE BUILDING OFFICIAL PRIOR TO THE SLAB POUR, THE SYSTEM <br />MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL ( PER FBC R320,1,1) <br />INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION <br />BACKFILLING i COMPACTION ARE COMPLETE ( PER FBC 320.1.2.) <br />ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE- TREATED <br />INCLUDING ANY BOX OR FORMED AREAS ( PER FBC R320.1,2) <br />BOXED AREA IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE <br />WITH PERMANENT METAL OR PLASTIC FORMS, PERMANENT FORMS MUST BE OF AN <br />ADEQUATE SIZE < DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE <br />INITIAL TREATMENT ( PER FBC R320.1.3) <br />A MINIMUM 6 MILL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE TREATMENT SHALL <br />BE REQUIRED (PER FBC R320.1,4) <br />ANY CONCRETE OVERPOUR , MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION <br />PERIMETER MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT, ( PER FBC R320,1,5) <br />EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 12" OF THE STRUCTURE SIDE WALLS (PER FBC R3 w.w <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS <br />COMPLETE ( INCLUDING LANDSCAPING AND IRRIGATION) ANY SOIL DISTURBED AFTER THE <br />VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED (PER FBC R320,1,6) <br />CONDENSATE AND ROOF DOWN SPOUTS DISCHARGE AT LEAST 12" AWAY FROM THE BUILDING <br />SIDE WALLS (PER FBC R320,1) <br />AFTER ALL WORK IS COMPLETE ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM <br />BELOW AND WITH IN 12" OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES TUB <br />TRAP BOXES, FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS <br />PER (FBC R320.8.3.) <br />THE DISTANCE FROM THE EXTERIOR WALL COVERING ( EXCEPTIONS, PAINT AND DECORATIVE <br />CEMENTITIOUS FINISH LESS THAN 5/8" THICK ADHERED DIRECTLY ONTO THE FOUNDATION WALL) <br />AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6" TO ALLOW FOR INSPECTION FOR FUTURE <br />TERMITE INFESTATIONS (PER FBC R104) <br />ELECTRICAL LEGEND <br />WF <br />GsLI <br />r-d <br />WATER PROOF 110 V SINGLE POLE <br />DUPLEX OUTLET STANDARD SWITCH <br />CEILINGS FAN <br />WITH LIGHT KIT <br />I HEREBY CERTIFY THAT I HAVE REVIEWED THE ATTACHED <br />VWC" AND FOUND IT TO BE N COMPLIANCE WfTH CHAPTER <br />16, OWTION *M OF THE FLORIDA WLDING CODE FOR 120 MPH <br />(3 SECOND MST) WND ZONE - 100 MPH FASMT SPEED AND THE <br />ENTIRE 200T KLORVA WWM CODE, AND ALL WOO SUPPLEMENTS <br />t11L Ito <br />T.L, HANWN P.E. LICENSE NO. 396U <br />P.O. 15OX rt*, DADE CITY, FL 33526 <br />0 <br />o� <br />G ^W <br />Z��M V ap <br />C�im��aG <br />O <br />yZt4 <br />3��NQ z <br />Z N- W <br />C W O <br />v� <br />O <br />O <br />M <br />m� <br />Z x <br />O ZZ U. <br />Z lu � � � V <br />m <br />O zZ Q <br />d <br />Q <br />O <br />ED <br />0 <br />� z <br />f] <br />lV�! <br />V <br />U� <br />a <br />LO <br />�a <br />a <br />COVERED <br />WALK 32S <br />COVERED <br />DECK 528 <br />TOTAL 851 <br />PGA <br />4 0F,5 <br />