Laserfiche WebLink
A I B I C i D i E I F i G i H I J <br />1 <br />4 <br />E <br />0 <br />m <br />U- <br />w <br />U <br />z <br />w <br />w <br />ti <br />LINE POST <br />T-10" FOR POSTS 8 5/8" O.D. <br />3'-4" FOR POSTS 6 5/8" O.D. <br />T-0" FOR POSTS 4" O.D. <br />AND LESS <br />d C <br />DOUBLE SWING GATE <br />SCALE: N.T.S. <br />OFFSET HINGE <br />STANDARD HINGE <br />SWING GATE DETAILS <br />SCALE: N.T.S. <br />3 HORIZONTAL STANDS <br />BARBED-WIRE <br />CHAIN -LINK FABRIC <br />3STRANDS <br />BARBED-WIRE (TYP) <br />GATE FRAME DIRECTION OF GATE SWING (TYP) N111- CHAIN -LINK FABRIC (TYP) <br />GATE OPENING <br />PLAN <br />GATE LEAF <br />FIRE ACCESS LOCKING 3 STRANDS <br />MECHANISM WITH KNOX BOX BARBED-WIRE (TYP) <br />- • <br />- <br />•i♦♦♦♦♦♦ <br />►iiiiiii <br />;'!.I <br />� <br />- ►�♦eeee♦e♦ <br />. .eee♦♦e♦e♦♦♦♦♦♦♦♦♦ <br />�,•�♦♦♦O♦O♦♦♦e♦♦♦e♦O♦♦ee♦Oeee♦i j <br />lea. <br />- „e♦:,♦e♦♦e♦ <br />IpoeQ♦e♦e♦Op♦p <br />'lt� <br />�- <br />► I <br />� <br />�•o�♦�♦s0♦�e�♦�O <br />I eoeeee♦♦ <br />►eo♦♦♦♦e <br />!►0iee`Oi♦ie <br />+eee♦♦ <br />- ♦♦♦e. <br />i►ODOOi•. <br />►eeeee♦eee♦ <br />♦eee♦e♦♦♦♦♦♦ ♦♦ <br />•eeeee♦e♦♦♦♦0i♦• <br />Di♦iei♦i♦iei♦i♦♦iei♦i♦i♦i!.'O <br />i ♦.�eee♦e♦♦ <br />♦.,�♦ee♦ee <br />♦i`••!♦♦e♦ee♦eQ <br />h �e♦♦♦e♦e♦ <br />- <br />i <br />! ♦.�.�♦e♦e♦ <br />►e.eeeee <br />�►OOe`•ee♦i♦ <br />♦eee• e��i♦:♦:♦ie <br />`•ep0�0e�. <br />':►♦e♦♦♦e♦e♦e ♦♦♦e1 <br />_ <br />! <br />� �e♦e♦♦♦♦♦eV1♦�� i <br />•♦i♦i♦i♦i♦ieiei <br />.���e♦♦e♦ • <br />.,eee♦ <br />I <br />- <br />• � — <br />�� <br />�i 1 <br />_ <br />' <br />I •— ■ <br />� <br />;�i <br />►� <br />► <br />'►♦♦♦e♦ <br />♦♦♦♦♦ <br />♦eee♦ <br />I <br />! <br />►eeeee <br />I i ♦eee♦� <br />ee♦ee <br />- ..... ♦ee��►ee♦♦♦ee <br />�►e♦♦♦e♦e♦eeeeee I <br />,► <br />, ��♦♦ <br />e <br />♦�. <br />..... <br />� <br />- <br />� , <br />►000eee <br />►O♦♦pi♦i <br />� <br />►000pe ♦♦♦♦�� <br />�►�eie0iei e�♦�e�♦�♦��►�i♦i♦i♦i♦Di♦ieo <br />►e♦♦♦e♦♦♦ <br />i <br />♦♦eee <br />►�♦ie00 <br />`�� <br />- • <br />�! <br />► � <br />�! <br />►ee♦e <br />♦♦♦♦ <br />�►0000 <br />I <br />i <br />►♦♦♦♦ ♦e♦♦e♦� <br />! e♦ee♦eieieiei♦iei��iei♦i♦i♦i♦i♦i'i�i <br />'►OOe♦ee .♦e♦♦♦♦u►♦♦♦♦e♦ee <br />♦♦♦♦e♦♦� <br />►ems♦ee♦e♦ <br />I►00e♦ ' <br />� <br />- <br />�� <br />� <br />► <br />�>♦e♦e♦�,♦� � <br />!►e♦iei�' � � <br />►♦y <br />ee, <br />- . <br />i <br />II <br />,>e♦e♦e♦ Qe♦♦.���♦♦ee♦♦e� <br />,►OOi O♦♦♦e♦.♦.��♦♦♦♦♦♦��►♦iei♦i!.'Oieiei♦i♦i♦ieiee. <br />►ey ♦♦eee�p�ee� <br />I e♦, ♦e♦♦e♦♦♦ee♦♦ .♦e♦e <br />��eQ♦♦Qe��.♦e♦♦e♦ee♦ ; <br />eee,.e♦eeee♦e♦es � <br />/ ►e♦♦♦� Ie♦e♦♦e♦et�♦♦♦e♦eee♦ee♦♦e <br />- - <br />.>ee♦♦ <br />►O <br />► ♦e�♦e� <br />I e♦♦♦♦♦ <br />►♦ � <br />♦e <br />u�i IIIIIIII III i1,i to <br />� • - - • <br />1 <br />PE FE-6 FENCE <br />10" <br />GATE KEEPER DROP ROD ASSEMBLY <br />(TO HOLD GATE OPEN) <br />ELEVATION <br />0 <br />ISSUED FOR PERMIT <br />08/26/22 <br />TJS <br />ACS <br />NHL <br />JPRH <br />AJD <br />REV <br />REVISION DESCRIPTION <br />DATE <br />DRWN <br />DSGN <br />CHKD <br />QC <br />APPD <br />REF. DWG. NO <br />LATCH ASSEMBLY <br />REFERENCE DRAWING TITLE <br />GATE POST SCHEDULE <br />GATE LEAF WIDTH <br />(NOMINAL) <br />OUTSIDE DIMENSION <br />(NOMINAL) <br />6' OR LESS <br />2.875" OD <br />2.5" SQ <br />MORE THAN 6' TO 13' <br />4.0" OD <br />MORE THAN 13' TO 18' <br />6.625" OD <br />MORE THAN 18' <br />8.625" OD <br />NSF.��IjjO�j�' <br />ro 67114 1Z. <br />:4rz: <br />'. �p % STATE OF 4 ,r <br />i��%23 ,P/24/20��!;F. <br />P <br />COR1© � S��`ti.: <br />finNAL <br />trll�ltt <br />3STRANDS <br />BARBED-WIRE ON <br />PERSONNEL GATE <br />SCALE: N.T.S. <br />O <br />Y" DIA. DROP ROD <br />(INDUSTRY STANDARD) <br />PAVED SURFACE <br />P.C. CONC <br />x mu <br />N C d <br />° aaa <br />BITUMINOUS <br />d <br />1" ID STEEL PIPE a im <br />co c7 <br />V co <br />v <br />6" DIA. P.C. CONC. d a <br />a <br />SAND/GRAVEL mmm <br />SECTION <br />DROP ROD FOUNDATION <br />SCALE: N.T.S. <br />3 STRANDS <br />BARBED-WIRE (TYP) <br />-"—GRADE LINE <br />BOTTOM TENSION WIRE (TYP) <br />PE FE-6 FENCE <br />NOTES: <br />1. DETAILS SHOWN ARE TO CLARIFY REQUIREMENTS AND ARE NOT INTENDED TO LIMIT OTHER <br />TYPES OF FENCE SECTIONS AND METHODS OF INSTALLATION. <br />2. SWING GATES SHALL BE CONSTRUCTED WITH DROP RODS, PADLOCKS, LATCH ASSEMBLY <br />AND GATE KEEPERS EXCEPT AS NOTED. <br />3. ALL GATE FRAMES SHALL BE A MINIMUM OF 1.90" NOMINAL (ROUND) OR 2.00" NOMINAL <br />(SQUARE). GATE FRAMES SHALL BE OF WELDED CONSTRUCTION OR SHALL BE ASSEMBLED <br />USING HEAVY FITTINGS. AT CONTRACTOR'S OPTION A WELDED HORIZONTAL BRACE MAY BE <br />USED IN LIEU OF TRUSS RODS TO BRACE ALL WELDED GATE FRAMES. THE CONTRACTOR <br />SHALL BE RESPONSIBLE FOR THE PROPER RIGID CONSTRUCTION OF ALL GATES SUPPLIED. <br />4. GATES SHALL BE DESIGNATED AS FOLLOWS: <br />FENCE TYPE - FE5, FE6, ETC. <br />FENCE HEIGHT - INCHES <br />TYPE OPENING - SO (SINGLE) <br />DO (DOUBLE) <br />HINGE - RA (STANDARD) <br />- HO (OFFSET) <br />OPENING - FEET (CLEAR OPENING BETWEEN GATE POSTS) <br />EXAMPLES: FE6-84-DO-RA-24 <br />FE5-48-SO-HO-6 <br />5. "BEST' PAD LOCK REQUIRED AT ALL ENTRY WAYS. <br />❑oo MERRICIC <br />00❑ <br />WHammwTuRNER <br />MERRICK PROJECT NO.: 3021600491 <br />CLIENT PROJECT NO.: <br />SCALE: AS NOTED <br />TITLE: <br />BLUE TRITON ZEPHYRHILLS <br />CIVIL <br />FENCE DETAILS 1 <br />0 <br />6004-CD-0 1 -005 <br />1 OF 1 <br />1 <br />3 <br />VA <br />Cam' <br />0 <br />110 <br />A B C D E F G H I J <br />