My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
4330 20th St (38)
Zephyrhills
>
Building Department
>
Building Plans
>
4330 20th St (38)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 8:59:10 AM
Creation date
2/18/2025 3:17:44 PM
Metadata
Fields
Template:
Building Plans
Street #
4330
Location
20th St
Contractor
The Whiting Turner Contracting Company
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
e <br />C <br />r: <br />E <br />F I G <br />1 <br />2 <br />STEP 1 NOTE: FOR WIRE SIZES #14, #12 AND #10. <br />+� 1/2" <br />IL -STRIP WIRES APPROXIMATELY 1/2" FROM ENDS <br />STEP 2 AND TWIST ENDS TOGETHER. <br />STEP 3 TWIST WIRE NUT ONTO WIRE ENDS. <br />PUSH WIRE NUT <br />INTO CONNECTOR <br />PAST TABS. <br />STEP 4 STEP 5 <br />STRAP TOP TO <br />CONNECTOR. <br />TABS <br />WIRE CONNECTION <br />u NTS 3 M- D B RN-6 <br />3 <br />1 <br />i <br />I <br />I <br />i <br />I <br />I <br />1 <br />I <br />1 <br />4 NOTE TO IRRIGATION CONTRACTOR: <br />1. LOCATE WHERE RAIN CAN FALL DIRECTLY INTO <br />DEVICE AND WHERE IRRIGATION HEADS CANNOT <br />SPRAY INTO SENSOR AREA. <br />2. INSTALL IN ACCORDANCE WITH MANUFACTURER'S <br />SPECIFICATIONS. <br />I <br />i <br />I <br />WIRELESS SENSOR <br />SIGNAL RECEIVER <br />I <br />I <br />CONTROLLER <br />5 <br />0 <br />W 0 <br />0 = <br />Z <br />Z <br />Zo <br />oQ - <br />Z Y <br />w T) <br />H w <br />— W <br />H0 <br />C.)U <br />W <br />2 it <br />CL W <br />Z0 6 <br />ly W <br />W = <br />0� <br />QQ <br />0 <br />J <br />Y <br />U <br />�W <br />LU — <br />m= <br />U <br />wu <br />Q 0 <br />aQ <br />W <br />Off. 0 <br />W <br />Uw 7 <br />>0 <br />lY = <br />W H <br />ca <br />LL <br />00 <br />WZ Z <br />to <br />co — <br />? w <br />Z W <br />Q � <br />� O <br />a' Z <br />O <br />w0 <br />UZI ~ <br />8 <br />� J_ <br />U ~ <br />U <br />00 <br />�0 <br />W� <br />U <br />W <br />= 0 - <br />O- <br />>_ W <br />Z N <br />zQLU <br />:D <br />U <br />Z� <br />0 <br />ow 9 <br />W <br />HO <br />NTS <br />PARAPET COPING <br />WIRELESS RAIN AND <br />FREEZE SENSOR <br />r ANTENNA <br />REMOTE <br />COMMON WIRE TO VALVES CONTROL <br />VALVE <br />CONTROL WIRE TO VALVES <br />RAIN SENSOR <br />NETAFIM AUTOMATIC LINE FLUSHING <br />VALVE <br />COMPRESSION RING <br />BLANK TL (TYP.) <br />LATERAL (OR EXHAUST <br />HEADER) <br />TEE <br />10" ROUND CARSON <br />VALVE BOX <br />SHUT-OFF VALVE #XXXX <br />(BLANK TUBING MAY BE <br />ATTACHED TO OUTLET) <br />(THREE) <br />LINE FLUSHING VALVE <br />NTS <br />NOTE: <br />INSTALLER OF SLEEVES SHALL BE RESPONSIBLE TO LOCATE <br />SLEEVES IF NOT PROPERLY INSTALLED. <br />2" CAPPED MARKER PIPE. <br />PIPE MUST EXTEND 6" BELOW <br />BOTTOM OF SLEEVE, PAINTED <br />FLOURESCENT PURPLE <br />CLASS 200 PVC SLEEVE <br />18" <br />BEDDING AND COMPACTION AS PER ENGINEER'S SPECIFICATIONS <br />SLEEVI NG <br />NTS <br />12" MIN. <br />24" MIN. <br />1MIN. <br />IRRIGATION CONTRACTOR SHALL INSTALL RAIN BIRD DRIP OPERATION <br />INDICATOR KIT AT EACH END OF ALL DRIP ZONE AREAS. <br />1Y <br />SPACING <br />FLUSWDRAIN VALVE IN 81N DIA. <br />O, <br />VALVE SOX AT ZONE LOW POINT. <br />�! <br />SHRUB - SPACING <br />TYPICAL. <br />-c <br />PVC LATERAL - <br />AT 12 IN DEPTH MIN. REFER TO <br />IRR. PLAN FOR SIZE. <br />TRIANGULAR <br />COMPENSATING <br />LEGEND FOR EMITTER SPACING & <br />GPH FLOW. <br />PVC DRIP LATERAL <br />PIPING - SIZE <br />PER FLOW DEMAND. <br />• <br />ELECTRIC REMOTE CONTROL DRIP <br />VALVE WTH FILTER IN VALVE <br />AIU� LEASE <br />BOX. REFER TO LEGEND <br />VALVE IN ER BOX <br />SCH 200 PVC MAINLINE <br />AT ZONE HIGH POINT. <br />NTS <br />IRRIGATION DRIPLINE <br />10" ROUND CARED FINISH <br />VALVE BOX GRADE <br />NETAFIM AUTOMATIC AIR / VACUU <br />RELIEF VALVE <br />3/4"M x 12"F TXT <br />REDUCTION BUSHING <br />314" PVC COUPLING (Tx <br />3/4" SCH 80 RISER (LENGTH A <br />REQUIRED) <br />W V <br />Y Y Y <br />00o0 <br />00000 <br />BRICK SUPPORTS (THREE 0000 <br />00000 <br />000 <br />A <br />00000. <br />GA <br />SO <br />WASHED GRAVEL <br />POLY TUBING CLAMPED T <br />STAINLESS STEEL <br />PVC INSERT FITTING <br />CLAMPS <br />AIRNACUUM <br />RELIEF <br />NTS <br />CONTRACTOR TO COMPLY WITH ALL LOCAL CODES AND ORDINANCES IN REFERENCE <br />TO THE INSTALLATION OF PVC PIPING AND LOW VOLTAGE WIRING. <br />MAIN SUPPLY, LATERAL MAIN LATERAL <br />AND LOW -VOLTAGE WIRING SUPPLY LINE <br />17' 12" 17' 12 <br />18" 18" <br />1" SCH 40 PVC ELECTRICAL LATERAL ( 1" SCH 40 PVC ELECTRICAL <br />CONDUIT WTH RAIN BIRD CONDUIT MATH RAIN BIRD <br />MAXI CABLE MAIN LINE MAXI CABLE 7, <br />• • • • • RAIN BIRD MAXI CABLE <br />• • • IN V SCH 40 PVC <br />• • ELECTRICAL CONDUIT <br />• 12-f <br />ALL MAINSUPLY LINES <br />TO BE INSTALLED IN <br />ACCORDANCE WITH <br />MANUFACTURER'S INSTAL- <br />LATION SPECIFICATIONS. <br />I TRENCHING <br />NTS <br />DRIPLINE MOUNTED WITH <br />4" OF MULCH COVER <br />FINISHED GRADE <br />MINIMUM 4" DEPTH <br />BELOW GROUND LEVEL <br />SCH 40 PVC ELBOW <br />EMITTER MOUNTING DETAIL 2" OPEN TRENCH <br />DRIP POLY ELBOW <br />DRIPLINE STAKE <br />PVC TO DRIPLINE ON 4' CENTERS <br />ADAPTER DRIPLINE PVC LATERAL <br />PIPING <br />DRIP EMITTER <br />NTS <br />\RSON ROUND VALVE BOX (#708) <br />INDING ROD: <br />HMS OF LESS <br />N/YELLOW WIRE FROM LSP-1 <br />RROUND ROD (1 OF 2) <br />'-6 WATER PROOF CONNECTION <br />F 2) <br />TURF M10008 LINE SURGE <br />TECTION <br />WIRE FROM LSP-1 <br />H MIN. DEPTH OF 3/4" <br />tHED GRAVEL <br />C (1 OF 2) <br />WIRE CABLE TO NEXT <br />ICE INSTALLED IN 1" SCH <br />LECTRICAL CONDUIT IRRIGATION CONTROLLER <br />NOTES: <br />1. LSP-1 SHOULD BE INSTALLED EVERY 300 FT ON TWO -WIRE PATH OR EVERY 6 <br />DECODERS (WHICHEVER IS SHORTER). <br />2. LSP-1 TO BE INSTALLED AT END OF WIRE RUN THAT TERMINATES IN THE FIELD <br />(STAR CONFIGURATION). <br />SURGE PROTECTION <br />NTS TO TWO -WI RE PATH <br />C <br />IRRIGATION CONTROLLER <br />SWEEP ELL -� <br />(1-1/2" OR LARGER) <br />COPPER Ground Plate — <br />PAIGE ELECTRIC PN: 182199L <br />6 AWG BARE <br />COPPER WIRE <br />6 AWG BARE <br />COPPER WIRE <br />70• <br />NOTE: <br />1. ALL WIRING TO BE INSTALLED <br />AS PER LOCAL CODE. <br />2. SEE CONTROLLER MANUAL FOR <br />MOUNTING INSTRUCTIONS. <br />3. INSTALL ALL MANUFACTURER'S <br />RECOMMENDED LIGHTNING RAIN BIRD STAINLESS <br />PROTECTION. STEEL PEDESTAL <br />CONTROLLER <br />(3)1-1/2" ELECTRICAL <br />CONDUITS <br />FOR TWO -WIRE MAXI -CABLE <br />AND GROUND WIRE <br />ANCHOR BOLTS (4) <br />18" X 18" X 8" <br />CONCRETE BASE <br />FINISH GRADE <br />jt <br />tir.. 8 <br />�120VOLT <br />o: <br />.•' �•' <br />��..w;�..w• <br />.►:;� .w;� <br />TWO -WIRE <br />POWER AND <br />f r•; f r,; : <br />;� •r;; ir; <br />MAXI CABLE <br />GROUND WIRES <br />TO REMOTE <br />6" <br />CONTROL <br />VALVES <br />1-1/2" SCH 40 ELECTRICAL <br />CONDUIT FOR #6-1 BARE <br />COPPER GROUND WIRE <br />J <br />CONTROLLER <br />NTS <br />PVC SUPPLY HEADER <br />TOP OF SLOPE <br />NETAFIM AUTOMATIC AIRNACUUM RELIEF ASSEMBLY <br />LINE FLUSHING VALVE ASSEMBLY <br />LATERAL TUBING <br />PVC EXHAUST HEADER <br />TOE OF SLOPE <br />CONVENTIONAL SPACING <br />ON TOP 2/3 OF SLOPE <br />REMOTE CONTROL VALVE <br />ASSEMBLY WITH DISC FILTER AND <br />CONVENTIONAL SPACING PRV <br />PLUS 25% ON BOTTOM 1/3 <br />OF SLOPE <br />DRIP TUBING <br />NTS SLOPED FEED LAYOUT <br />12" <br />6 AWG BARE <br />COPPER WIRE <br />CADWELD CONNECTION <br />6 AM BARE COPPER WIRE TO EACH <br />SATELLITE GRID AND COMPUTER <br />CENTRAL CONTROLS. <br />100mm CAPPED PERFORATED PIPE <br />WITH POWERFIL CHEMICAL <br />TREATMENT. EACH END COVERED <br />36" 10" AMETEK VALVE BOX <br />COPPER Ground Plate <br />PAIGE ELECTRIC PN: 182199L <br />EARTH CONTACT MATERIAL <br />GROUND ROD <br />TOP VIEW — <br />NOTE <br />ELECTRIC PN: 182007 <br />SIDE VIEW NOTE <br />IF 10 OHMS OR LESS RESISTANCE CAN NOT BE <br />ACHIEVED WITH THE GROUND GRID AND BARE <br />WIRE TO THE IRRIGATED AREA, INSTALL 100mm <br />PREFORATED PIPE IN CENTER OF THE GROUNDING <br />GRID AND FILL WITH POWERFIL GROUND TREATEMENT. <br />IDEALLY THE PIPE SHOULD BE AS DEEP AS THE <br />R CONTROLLER GROUNDING AT LEAST OUND R100' INTRO IRRIGATION AREA. <br />ARE COPPER WIRE SHALL EXTEND <br />NTS GROUNDING TO BE INSTALLED AS PER <br />ASIC GUIDELINES WITH GROUNDING PLATE. <br />OR <br />PER <br />INT <br />TITLE: <br />BLUE TRITON ZEPHYRHILLS <br />CIVIL <br />IRRIGATION DETAILS 2 <br />PERMIT <br />06/30/23 <br />ICS <br />ICS <br />IEA <br />IEA <br />IEA <br />CITY COMMENTS <br />06/02/23 <br />ICS <br />ICS <br />JWC <br />IEA <br />IEA <br />REVISION: <br />0 <br />DRAWING NO.: <br />6004-IP-01-006 <br />SHEET NO.: <br />6 OF 6 <br />REVISION DESCRIPTION <br />DATE <br />DRWN <br />DSGN <br />CHKD <br />QC <br />APPD <br />REF. DWG. NO <br />REFERENCE DRAWING TITLE <br />A B C D E F G H I J <br />2 <br />ISSUED F <br />1 <br />REVISED <br />REV <br />❑+�❑ <br />MERRICK* <br />W�'�"��� <br />MERRICK PROJECT NO.: 3021600491 <br />CLIENT PROJECT NO.: <br />SCALE: <br />AS NOTED <br />1 <br />2 <br />3 <br />4 <br />5 <br />7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.