My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
4330 20th St (41)
Zephyrhills
>
Building Department
>
Building Plans
>
4330 20th St (41)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 9:05:10 AM
Creation date
2/18/2025 3:18:56 PM
Metadata
Fields
Template:
Building Plans
Street #
4330
Location
20th St
Contractor
Ryman Construction
Building Plans - Permit #
14830
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
KEYNOTES: ® KEYNOTES: <br />P-ML 1. APPROXIMATE LOCATION OF NEW PANELS SHOWN ON� 1. PROVIDE 20A SINGLE POLE MANUAL MOTOR CONTROLLER <br />MEZZANINE. CONTRACTOR SHALL LOCATE AND INSTALL i°� % f FOR ELECTRICAL WATER HEATER. <br />NEW PANELS IN A MANNER THAT IS IN ACCORDANCE <br />RP L WITH CURRENT NEC CLEARANCE AND SPACING 1 i r 2. PROVIDE 20A SINGLE POLE MANUAL MOTOR CONTROLLER <br />REQUIREMENTS. COORDINATE LOCATION WITH EXISTING H ! FOR DOMESTIC CIRCULATION PUMP. <br />AND NEW EQUIPMENT. ' <br />P-ML I / 3. PROVIDE JUNCTION BOX AND CONDUIT STUBBED ABOVE <br />2. ROOF TOP UNIT LOCATED ON ROOF. COORDINATE WITH r 217 _ %� CEILING FOR LOW VOLTAGE WIRING FOR CARD READER <br />MECHANICAL DRAWINGS FOR LOCATION. REFER TO SHEET f FROM EXISTING SECURITY PANEL. CONTRACTOR TO <br />E-010 FOR EQUIPMENT INFORMATION. PROVIDE WEATHER r COORDINATE LOCATION IN FIELD. WIRING AND DEVICES <br />PROOF GFl RECEPTACLE MOUNTED TO UNIT. REFER TO TYPICAL CID ; ' LXIS-, G r/ BY OTHERS. <br />PANEL SCHEDULE RP-ML FOR CIRCUIT NUMBER AND <br />1 LA. ' RCC % <br />SIZE. 4. PROVIDE POWER TO JUNCTION BOX FOR NEW <br />21 DISHWASHER <br />3. EXHAUST FAN LOCATED ON ROOF. COORDINATE WITH <br />MECHANICAL DRAWINGS FOR LOCATION, REFER TO SHEET -� 6 3 5. EXISTING STROBES. <br />E-010 FOR EQUIPMENT INFORMATION. PROVIDE WEATHER - Q-1 = - 3 CR <br />PROOF SINGLE POLE MANUAL MOTOR CONTROLLER BY Q-1 Q-1 - _— - 6. PROVIDE NEW FIRE ALARM DEVICE AND CONNECT TO <br />THE UNIT. CR CR ON POOF EXISTING FIRE ALARM CONTROL PANEL CONTRACTOR <br />6 H 22 E SHALL VERIFY LOCATION OF PANEL IN FIELD AND VERIFY <br />�i EXPANDABILITY OF PANEL PROVIDE PANEL AS NEEDED. <br />EF P 3 Q-1 Q-1 3 1 CR r <br />i MICRO LA 22 6 7. PROVIDE 4" SQUARE BOX WITH 3/4" CONDUIT STUBBED <br />I TO ABOVE CEILING FOR DATA WIRING AND DEVICES BY <br />218: '9 24 OTHERS. <br />EQ-9 7 i � _ <br />8. CONTRACTOR SHALL VERIFY AND MATCH EXISTING <br />29 18 <br />EQUIPMENT OUTLET TYPE. <br />� � r/r <br />! 7 22 5 r r' <br />° r GENERAL NOTES: <br />O I 18 III 1. REFER TO SHEET E-010 FOR EQUIPMENT AND PANEL <br />, / SCHEDULES. <br />a <br />EQ-2 T <br />1 J 4 2. CONNECT EQUIPMENT AND DEVICES SHOWN TO PANELS <br />GF DESIGNATED ON PLANS, UNLESS NOTED OTHERWISE. <br />ZVI <br />V LYTiUAL r� 3. ALL POWER IS FED FROM PANEL RP-ML UNLESS NOTED <br />EQ-1 2 LAB 7 OTHERWISE. <br />j 219 <br />EQ 4 EQ-4 CR° <br />EQ-4 <br />'Al 'E i j/ <br /># RTU �0 <br />% / <br />GF17 1 <br />it ✓ <br />2 NORTH r � ,✓` /' �! NORTH <br />4 ELECTRICAL MEZZANINE POWER PLAN 2 ELECTRICAL FIRST FLOOR POWER PLAN <br />SCALE: 1/8" = V-0' SCALE: 1/8" = 1'-0' <br />GENERAL NOTES: KEYNOTES: <br />�. <br />1. R - 1 � ,� ,' / �' , ;,s' 1. DISCONNECT AND REMOVE EXISTING ELECTRICAL WATER <br />DEVICE SCHEDULES. L21 - /r i / HEATER AND ASSOCIATED DEVICES ON MEZZANINE. <br />/ rr f <br />f C? i ' r'/ ,/// ,/� COORDINATE WITH PLUMBING PLANS FOR ADDITIONAL <br />2. ALL LIGHTING SHALL BE FED FROM PANEL PP-ML I R M r, ' ! INFORMATION. <br />UNLESS NOTED OTHERWISE. REFER TO SHEET E-010 <br />XIST G FOR PANEL SCHEDULE AND CIRCUIT INFORMATION. / 21 I 2. DISCONNECT AND REMOVE ALL EXISTING LIGHTING <br />OF GE FIXTURES, RECEPTACLES AND ASSOCIATED DEVICES <br />3. EMERGENCY WALL PACKS SHALL BE WIRED AHEAD OF i /, /ill WITHIN AREA. <br />217 N. SWITCH OR OCCUPANCY SENSOR OF THE LOCAL AREA / <br />CIRCUIT. 3. ALL UNUSED EXISTING CONDUIT AND WIRES AND WIRES <br />AND CONDUITS ABANDONED IN THE REMODELED AREA <br />XIS G 4. PROVIDE LOCKABLE CIRCUIT BREAKERS FOR EXIT SIGNS. 1 r r SHALL BE REMOVED TO SOURCE. ALSO REMOVE <br />LAN GG r CONDUIT AND WIRES TO BE DEMOLISHED DUE TO THE <br />21 5. ALL OCCUPANCY SENSORS SHALL BE WIRED AS 1 ( REMODELING. <br />VACANCY SENSORS WITH MANUAL 'ON' AND AUTOMATIC ' <br />'OFF'. WALL SENSORS SHALL ACT AS OVERRIDE DEVICES. r 4. ALL EQUIPMENT, RECEPTACLE AND LIGHTING THAT IS <br />DISCONNECTED SHALL BE DISCONNECTED AT THE <br />r ,'✓ / SOURCE ANDHAVE THE EXISTING CIRCUIT BREAKER <br />3a 3a �_._ r/ ff S / / LABELED AS 'SPARE', UNLESS THE EXISTING BREAKER IS <br />tvtl RO LAB ' �* DESIGNED FOOTCANDLE RANGE: 50-80FC ��� % f / FEEDING OTHER EQUIPMENT NOT BEING REMOVED. <br />21 1 a 1 a la 5. EXISTING STROBES TO REMAIN. ADJUST IN FIELD AS <br />1b _° _ ' % REQUIRED PER NEW WALL CONSTRUCTION. <br />13a F 3a <br />r`� % � f 6. EXISTING EXHAUST FAN EF-IX TO REMAIN. COORDINATE <br />a EXACT LOCATION WITH MECHANICAL DRAWINGS. <br />3b 3 % <br />IT - <br />La a to <br />GENERAL NOTES: <br />o <br />3b 3 \ / 1. EVES <br />1a a TO SHEET E-002 FOR ADDITIONAL DEMOLITION <br />M <br />1 5� <br />A AIYTICf L <br />6 <br />219 I <br />1 1b lb 1b 1b' <br />1b <br />I <br />ST G <br />0P I / <br />NORTH / / / I NORTH <br />Expir <br />3 ELECTRICAL LIGHTING REFLECTED CEILING PLAN ELECTRICAL DEMOLITION PLAN FS 2 zo15 <br />SCALE: 1/8" = V-0' <br />AL 1 8" =1'-0' <br />SHFp''�, <br />MEP / FP Engineer Design Architect Nestle Waters North America TM <br />_ <br />EPSTEIN <br />600 West Fulton <br />Chicago, IL 60661 <br />312.454.9100 <br />EPSTEIN <br />600 West Fulton <br />Chicago, IL 60661 <br />312.454.9100 <br />Nestle Waters North America <br />4330 20th Street <br />Zephyrhills, Florida 33542-6703 <br />972.462.3663 <br />Waters <br />•sue -- <br />:�� 08 <br />STATE OF <br />• <br />o.�F� °... t ,ASS ........ �G <br />q�14�19 J,sM.111 ` <br />4 <br />3 <br />2 <br />09.18.2013 <br />09.11.2013 <br />09.03.2013 <br />ISSUE FOR PERMIT <br />ISSUE FOR BIDS <br />CD REVIEW PACKAGE <br />1 <br />NO. <br />08.16.2013 <br />DATE <br />DD REVIEW PACKAGE <br />REVISIONS/ISSUANCES <br />� P S T E I N <br />Architecture <br />Chicago <br />Interiors <br />New York <br />Engineering <br />Bucharest <br />Construction <br />Warsaw <br />600 W. Fulton Street <br />Chicago, IL 60661-1259 <br />T 312.454.9100 <br />www.epsteinglobal.com <br />PROJECT NUMBER: <br />12386 <br />PROJECT MANAGER: <br />JK <br />ARCH/ENG: <br />DD <br />SCALE: <br />1/8" =1'-0" <br />DRAWN BY: <br />DD <br />CHECKED BY: <br />MS <br />DEMOLITION, POWER, <br />AND REFLECTED CEILING <br />LIGHTING PLANS <br />E-101 <br />©X)= A. Epstein and Sons International, Inc. All rights reserved <br />
The URL can be used to link to this page
Your browser does not support the video tag.