Laserfiche WebLink
TYPICAL ELECTRICAL [YIOIJuiN4 FEOHTIB <br />FIRE PROTECTION DEVICE <br />13 <br />/ PHONE __(ALIGN EDGE WITH SWITCH) <br />4■ LIGHT SNATCH, SENSORS, ETC <br />71Z 00 <br />THERMO ATco <br />/SENSO <br />\N MIop 4 -,�k-G <br />OUTSIDE EDGE OF DOOR FRAME VOICE/DATA 0 <br />AND/OR EDGE OF WALL <br />ELECTRICAL OUTLET <br />TYPICAL MILLWORK <br />MOUNT NON -OPERABLE SENSORS, FIRE ALARM A/V DEVICES CENTERED ABOVE LIGHT <br />SWITCHES., U.N.O. REFER TO MEP DRAWINGS FOR ADDITIONAL LOCATION OF RELATED ITEMS <br />DETAIL CALLOUT <br />DISCIPLINE DESIGNATOR - <br />PRIORITY NUMBER -� \ <br />PI F\/ATIr)N - IAITI=RIr1R 3 <br />DETAIL NUMBER <br />1 <br />A-101 CALLOUT <br />SHEET <br />NUMBER <br />L — <br />2,_ <br />DETAIL NUMBER <br />SHEET NUMBER <br />BREAK LINE __V__ <br />CEILING HEIGHT (AFF) <br />CEILING TAG - <br />CEILINGTYPE <br />CENTER LINE CE <br />COLUMN BUBBLE O� <br />LEVEL NAME <br />ELEVATION - DATUM gilk LOBBY LEVEL DOOR TAG DR # <br />EL: 100' - 0' <br />\__LEVEL LINE <br />LEVEL ELEVATION <br />EQUIPMENT TAG EQ-2 <br />TYP. ELECTRICAL MOUNTING HEIGHTS L N <br />DETAIL NUMBER <br />SECTION 1A-10 NORTH ARROW <br />SHEET NUMBER <br />REVISION TAG <br />ROOM NAME <br />DETAIL NUMBER �� <br />1 -w LOBBY <br />SECTION - DETAIL 1A-10 ROOM TAG 101 ROOM NUMBER <br />SHEET NUMBER 150 SF � ROOM AREA (IF <br />PRESENT) <br />WALL TAG Al (SEE SHEET A-801 <br />FOR TYPES) <br />FINISH TAG W --- WALL FINISH <br />B --- BASE FINISH <br />F --- FLOOR FINISH <br />C --- CEILING FINISH <br />DRAWING SYMBOLS <br />PARTITIONS EXISTING PARTITION <br />DEMOLITION <br />NEW PARTITION <br />GENERAL NOTES <br />1. THE 'CONTRACT DOCUMENTS' SHALL INCLUDE THESE <br />ARCHITECTURAL DRAWINGS, SPECIFICATIONS, THE WRITTEN <br />CONTRACT BETWEEN OWNER AND GENERAL CONTRACTOR, <br />AND ANY OTHER AGREED ATTACHMENTS TO SAID <br />CONTRACT. <br />2. THE TERM "OWNER" SHALL INCLUDE NESTLE WATERS <br />NORTH AMERICA, ITS EMPLOYEES AND ITS AGENTS. <br />3. THE TERM ARCHITECT/ENGINEER SHALL INCLUDE EPSTEIN, <br />THEIR EMPLOYEES AND THEIR AGENTS. <br />4. THE TERM 'CONTRACTOR 'SHALL INCLUDE THE GENERAL <br />CONTRACTOR, HIS EMPLOYEES AND AGENTS, AND ALL <br />SUBCONTRACTORS AND SUPPLJERS. <br />5. PRIOR TO THE START OF ANY WORK UNDER THIS <br />CONTRACT, THE GENERAL CONTRACTOR SHALL SUBMIT, <br />FOR ACCEPTANCE BY THE OWNER AND THE LANDLORD, <br />ALL REQUIRED INSURANCE DOCUMENTATION, INCLUDING <br />CERTIFICATE OF INSURANCE. THE OWNER, THE ARCHITECT <br />AND THE LANDLORD SHALL BE NAMED AS ADDITIONAL <br />INSURED ON THE CONTRACTOR'S CERTIFICATE OF <br />INSURANCE. <br />6. ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH <br />ALL LOCAL, STATE AND FEDERAL CODES AND ORDINANCES <br />7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING <br />ALL PERMITS AND LICENSES, AND FOR ALL FEES <br />ASSOCIATED THEREIN. <br />8. PRIOR TO THE START OF ANY WORK UNDER THIS <br />CONTRACT, THE GENERAL CONTRACTOR SHALL CONFIRM <br />WITH THE BUILDING OPERATING REGULATIONS WITH THE <br />OWNERS REPRESENTATIVE FOR THIS PROJECT: <br />• THE BUILDING OPERATING REGULATIONS SHALL BE <br />MAINTAINED THROUGHOUT THE COURSE OF <br />CONSTRUCTION. <br />•THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR <br />ALL REQUIRED COORDINATION WITH THE OWNER'S <br />REPRESENTATIVE, INCLUDING CONSTRUCTION ACCESS, <br />BUILDING WORKING HOURS AND CONSTRUCTION PARKING. <br />10. PRIOR TO SUBMITTING BIDS, THE CONTRACTORS SHALL <br />VISIT THE SITE AND BECOME FAMILIAR WITH THE ACTUAL <br />EXISTING CONDITIONS. THE OWNER AND THE ARCHITECT <br />ASSUME NO RESPONSIBILITY FOR THE EXISTING <br />CONDITIONS ON THE PROJECT SITE. <br />11. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER <br />AND THE ARCHITECT OF ANY DISCREPANCIES BETWEEN <br />THE PROJECT DRAWINGS AND EXISTING CONDITIONS. <br />12. THE GENERAL CONTRACTOR SHALL VERIFY ALL PROJECT <br />RELATED CONDITIONS, DIMENSIONS AND DETAILS PRIOR TO <br />CONSTRUCTION AND AS ANTICIPATED OR INFERRED PRIOR <br />TO PRICING OR BIDDING. <br />13. EPSTEIN SHALL BE NOTIFIED OF ANY DISCREPANCIES OR <br />OMISSIONS WHICH WOULD INTERFERE WITH THE <br />SATISFACTORY COMPLETION OF THE WORK, PRIOR TO THE <br />START OF ANY AND ALL WORK. <br />14. ALL WORK, WHETHER SHOWN OR IMPLIED, UNLESS <br />SPECIFICALLY QUESTIONED, SHALL BE CONSIDERED FULLY <br />UNDERSTOOD IN ALL RESPECTS BY THE GENERAL <br />CONTRACTOR, AND HE WILL BE RESPONSIBLE FOR ANY <br />MISINTERPRETATIONS OR CONSEQUENCES THEREOF FOR <br />ALL WORK ON ALL DRAWINGS. <br />15. THESE GENERAL NOTES SHALL APPLY TO ALL DRAWINGS. <br />16. THROUGHOUT THE COURSE OF CONSTRUCTION, THE <br />25. INCLUDE THE REMOVAL OF CONDUITS, CONDUCTORS, <br />OWNER RESERVES THE RIGHT TO MAKE REASONABLE <br />PIPING, DUCTS AND ALL OTHER UTILITY DISTRIBUTION <br />MODIFICATIONS TO THE PLANS AND IN THE LOCATIONS OF <br />NETWORKS BACK TO SOURCE IF POSSIBLE. IF UNABLE TO <br />NEW EQUIPMENT, FIXTURES AND FINISH MATERIALS AS <br />ACCOMPLISH TASK OR ENCOUNTER SEVERE HARDSHIP; <br />REQUIRED BY BUSINESS REQUIREMENTS OR BUILDING <br />FOR ELECTRICAL DEMOLITION WORK, ALL TERMINATIONS <br />CONDITIONS. <br />WITH OWNER APPROVAL MAY BE MADE AT FIRST EXISTING <br />ITEM/BOXES LEFT UNAFFECTED BY THE DEMOLITION OR IN <br />17. IN THE EVENT THAT, IN THE OPINION OF THE <br />NEW BOXES AND CAPPED AT AN EASILY ACCESSIBLE <br />CONTRACTOR, ANY PROPOSED MODIFICATION TO THE <br />LOCATION. CONDUITS WHICH ARE BURIED OR OTHERWISE <br />PROJECT DESIGN, INCLUDING UNIDENTIFIED FIELD <br />INACCESSIBLE SHALL BE ABANDONED WITH OWNER <br />CONDITIONS OR OWNER MODIFICATIONS, WILL RESULT IN <br />APPROVAL IN SUCH CASE, THE CONTRACTOR SHALL PULL <br />AN ADDITIONAL SERVICE TO THE CONTRACT, THE OWNER <br />ALL WIRING FROM CONDUITS, CUT BACK CONDUITS TO BE <br />AND THE ARCHITECT SHALL BE ADVISED IMMEDIATELY. <br />FLUSHED WITH FINISHED SURFACE - CAPPED FOR WALL <br />AND CEILING AND FILLED WITH GROUT FOR FLOOR. FOR <br />18. ALL NECESSARY SEPARATION, PROTECTION, AND <br />MECHANICAL DUCTWORK, ABANDONED DUCT MUST BE <br />BARRICADES, INCLUDING DUST -PROOF PARTITIONS AND <br />REMOVED BACK TO UNAFFECTED TRUNK OR BRANCH FEED <br />TEMPORARY BUILDING SERVICES, ARE SOLELY THE <br />AND CAPPED. THE SYSTEM WITHIN THE AFFECTED ZONE <br />RESPONSIBILITY OF THE GENERAL CONTRACTOR. <br />WILL NEED TO BE REBALANCED IF THERE ARE <br />SUBSTANTIAL CHANGES AFFECTING EXISTING AIR <br />19. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF <br />DISTRIBUTION OR DESIGN. ALL CHANGES MUST BE <br />ALL COMPLETED WORK UNTIL AFTER ACCEPTANCE OF <br />DOCUMENTED AND OBTAIN OWNER APPROVAL <br />WORK AND TURNOVER OF THE PREMISES TO THE OWNER <br />26. WORK INDICATED AS REUSE AND RELOCATION OF EXISTING <br />FOR OCCUPANCY. <br />SYSTEMS OR EQUIPMENT MUST BE COORDINATED WITH ALL <br />20. THE CONTRACTOR IS RESPONSIBLE FOR REPAIR AND <br />ASSOCIATED EQUIPMENT AT ITS FINAL LOCATION. <br />RESTORATION OF ALL EXISTING WORK DESIGNATED TO <br />EQUIPMENT INDICATED FOR REUSE MUST BE VERIFIED <br />REMAIN IN PLACE DISTURBED IN THE EXECUTION OF THIS <br />THAT IT IS IN GOOD WORKING CONDITION AND HAVE THE <br />CONTRACT. <br />CAPACITY TO SUPPORT THE NEW DESIGN. NEW WORK <br />THAT UTILIZES AN ADAPTIVE REUSE OF AN EXISTING <br />21. EACH CONTRACTOR SHALL GUARANTEE HIS WORK <br />SYSTEM MUST BE PROVIDED WITH FULL WARRANTY <br />(MATERIAL, INSTALLATION AND LABOR) FOR A PERIOD OF <br />PROTECTION AND THE USAGE MUST NOT DIMINISH ANY <br />ONE (1) YEAR FROM THE DATE OF SUBSTANTIAL <br />EXISTING WARRANTY PROTECTION. <br />COMPLETION OF THE WORK AND ACCEPTANCE BY THE <br />OWNER, UNLESS A DIFFERENT WARRANTY PERIOD IS <br />27. EXECUTION OF THIS CONTRACT BY THE CONTRACTOR <br />SPECIFIED IN INDIVIDUAL MATERIAL SPECIFICATIONS <br />SHALL NOT INTERFERE OR DISRUPT THE FUNCTIONS <br />SECTIONS. <br />OF THE FACILITY UNLESS SUCH INTERFERENCE ARE <br />UNAVOIDABLE AND IN SUCH CASES THESE WORK <br />22. AT THE COMPLETION OF CONSTRUCTION, AND PRIOR TO <br />MUST BE COORDINATED, APPROVED AND SCHEDULED <br />THE RELEASE OF ANY RETAINAGE, THE CONTRACTOR SHALL <br />WITH THE OWNER PRIOR TO THE COMMENCEMENT OF SUCH <br />FURNISH THE OWNER FOUR (4)COPIES OF THE PROJECT <br />WORK. IN ALL CASES, SUCH WORK SHALL NOT <br />CLOSE-OUT DOCUMENTATION, TO INCLUDE THE FOLLOWING <br />AFFECT THE SAFETY, HEALTH AND WELFARE OF THE <br />• AS -CONSTRUCTED RECORD DRAWINGS OF ALL WORK, <br />FACILITIES PERSONNEL AND MUST BE PROTECTED. <br />INCLUDING ARCHITECTURAL, MECHANICAL, ELECTRICAL, <br />PLUMBING AND FIRE PROTECTION WORK INSTALLED <br />UNDER THIS CONTRACT. <br />• ORIGINAL COPIES OF ALL PERMITS, INSPECTION REPORTS <br />AND CERTIFICATES ISSUED BY JURISDICTIONAL <br />GOVERNMENT AGENCIES. <br />• OPERATIONAL AND MAINTENANCE INFORMATION FOR ALL <br />MATERIALS AND EQUIPMENT PURCHASED UNDER THIS <br />CONTRACT. <br />23. ALL PENETRATIONS THROUGH WALLS, FLOORS, CEILINGS <br />AND/OR PARTITIONS OF ANY TYPE MUST BE TIGHTLY <br />SEALED. PENETRATIONS THROUGH FIRE RATED <br />CONSTRUCTION INCLUDING BUT NOT LIMITED TO WALLS, <br />FLOORS, CEILINGS, ETC MUST BE SEALED TO MAINTAIN <br />THE SAME FIRE RATING AS THE ITEM BEING PENETRATED. <br />24. ALL CONSTRUCTION SHALL CONFORM TO THE LATEST <br />VERSION OF THE NESTLE WATERS NORTH AMERICA - <br />FACILITIES DESIGN GUIDELINES. <br />STANDARD ABBREVIATIONS <br />SYMBOL <br />DESCRIPTION <br />SYMBOL <br />DESCRIPTION <br />SYMBOL IDESCRIPTION <br />SYMBOL <br />DESCRIPTION <br />SYMBOL <br />DESCRIPTION <br />SYMBOL <br />DESCRIPTION <br />SYMBOL <br />DESCRIPTION <br />A/C <br />Air Conditioning <br />CJ <br />Control Joint <br />EXH <br />Exhaust <br />HW <br />Hot Water <br />MP <br />Moveable Partition <br />RE <br />Refer <br />T/ <br />Top of <br />A/V <br />Audio -Visual <br />CL <br />Center Line <br />EXST <br />Existing <br />HWH <br />Hot Water Heater <br />MRB <br />Marble <br />RECEP <br />Reception <br />TA <br />Table <br />ABV <br />Above <br />CLG <br />Ceiling <br />EXT <br />Exterior <br />ID <br />Inside Diameter <br />MTD <br />Mounted <br />RECPT <br />Receptacle <br />TS <br />Tackboard <br />ACC <br />Accessories <br />ICLO <br />Closet <br />EXTD <br />Extruded <br />IN <br />Inch <br />MTG <br />Mounting <br />REFG <br />Refrigeration/Refrigerator <br />TELE <br />Telephone <br />ACOUST <br />Acoustical <br />CLR <br />Clear <br />FA <br />Fabric <br />INCAND <br />Incandescent <br />MTL <br />Metal <br />REFL <br />Reflected <br />TEMP <br />Temporary <br />ACP <br />Acoustical Ceiling Panel <br />CMU <br />Concrete Masonry Unit <br />FAB <br />Fabrication <br />INCL <br />Include(d)(ng) <br />MULL <br />Mullion <br />REINF <br />Reinforce(d)(ing)(ment) <br />THK <br />Thick, Thickness <br />ACT <br />Acoustical Ceiling Tile <br />CNR <br />Counter <br />FC <br />File Cabinet (Metal) <br />INFO <br />Information <br />MW <br />Millwork <br />READ <br />Required <br />THRES <br />Threshold <br />ADA <br />Americans with Disabilities Act <br />COL <br />Column <br />FD <br />Floor Drain <br />INSUL <br />Insulation <br />N <br />North <br />REV <br />Revise, Revision <br />THRU <br />Through <br />ADH <br />Adhesive <br />COMB <br />Combination <br />FE <br />Fire Extinguisher <br />INT <br />Interior <br />N/A <br />Not Applicable <br />RF <br />Resilent Flooring <br />TOF <br />Top of Footing <br />ADJ <br />Adjust/Adjustable <br />COMPR <br />Compress/Compressible <br />FEC <br />Fire Extinguisher Cabinet <br />JAN <br />Janitor <br />NIC <br />Not in Contract <br />RH <br />Right Hand <br />TOS <br />Top of Steel <br />AFF <br />Above Finished Floor <br />CONIC <br />Concrete <br />FF <br />Finished Floor <br />J-BOX <br />Junction Box <br />NOM <br />Nominal <br />RM <br />Room <br />TYP <br />Typical <br />AGG <br />Aggregate <br />CONF <br />Conference <br />FHV <br />Fire Hose Valve <br />JT <br />Joint <br />NRC <br />Noise Reduction Coefficient <br />RND <br />Round <br />UC <br />Undercut <br />AHU <br />Air Handling Unit <br />CONST <br />Construction <br />FIN <br />Finish(ed) <br />KIT <br />Kitchen, Kitchenette <br />NTS <br />Not to Scale <br />RO <br />Rough Opening <br />UL <br />Underwriters' Laboratories <br />ALT <br />Alternate <br />CONT <br />Continued, Continuous <br />FIXT <br />Fixture <br />KO <br />Knock Out <br />NUM <br />Number <br />RUB <br />Rubber <br />UNFN <br />Unfinished <br />ALUM <br />Aluminum <br />CONTR <br />Contractor <br />FLMTD <br />Floor Mounted <br />KP <br />Kick Plate <br />OA <br />Overall <br />S <br />South <br />UNIF <br />Uniform <br />ANOD <br />Anodized <br />CPT <br />Carpet <br />FLR <br />Floor <br />L <br />Length, Angle <br />OC <br />On Center <br />SA <br />Supply Air <br />UNO <br />Unless Noted Otherwise <br />APA <br />American Plywood Association <br />ICIR <br />Credenza <br />FLUOR <br />Fluorescent <br />LAB <br />Laboratory <br />OD <br />Outside Diameter <br />SAN <br />Sanitary <br />UTIL <br />Utility <br />APPD <br />Approved <br />CT <br />Ceramic Tile <br />FP -I <br />Fire Proofing -Intumescent <br />LACQ <br />Lacquer <br />OF <br />Outside Face <br />Sc <br />Solid Core <br />VAR <br />Varies/Varied <br />APPROX <br />Approximate111) <br />Depth/Deep <br />FP-S <br />Fire Proofing -Sprayed <br />LAM <br />Laminate(d) <br />OFF <br />Office <br />SCHED <br />Schedule(d) <br />VAT <br />Vinyl Asbestos Tile <br />ARCH <br />Architect, Architecture, Architectural <br />DEPT <br />Department <br />FT <br />Feet, Foot <br />LAV <br />Lavatory <br />OH <br />Overhead <br />SECT <br />Section <br />VAV <br />Variable Air Volume <br />ASTM <br />American Society for Testing and Materials <br />DIET <br />Detail <br />FTP <br />Fabric Tack Panel <br />LB <br />Pound <br />OPHD <br />Opposite Hand <br />SERV <br />Service <br />VB <br />Vapor Barrier <br />ASYM <br />Asymmetrical <br />DF <br />Drinking Fountain <br />FUT <br />Future <br />LBL <br />Label <br />OPNG <br />Opening <br />SF <br />Square Foot (Feet) <br />VCT <br />Vinyl Composition Tile <br />AUTO <br />Automatic <br />DIA <br />Diameter <br />FWC <br />Fabric Wall Covering <br />LE <br />Leather <br />OPP <br />Opposite <br />SHT <br />Sheet <br />VERT <br />Vertical <br />AUX <br />Auxiliary <br />DIM <br />Dimension <br />GA <br />Gauge <br />LF <br />Lineal Feet <br />PED <br />Pedestal/Stand <br />SIM <br />Similar <br />VEST <br />Vestibule <br />AVG <br />Average <br />DISP <br />Dispenser <br />GALV <br />Galvanized/Zinc Coated <br />LH <br />Left Hand <br />PL <br />Plant/Planter <br />SMD <br />Smoke Damper <br />VIF <br />Verify In Field <br />AWT <br />Acoustical Wall Treatment <br />DISTR <br />Distribution <br />GC <br />General Contractor <br />LK <br />Locker <br />PLAM <br />Plastic Laminate <br />SNT <br />Sealant <br />VNR <br />Veneer <br />AXF <br />Access Flooring <br />DIV <br />Division <br />GFI <br />Ground Fault Interrupter <br />LPLAM <br />Low Pressure Laminate <br />PLAS <br />Plaster <br />SO <br />Sofa <br />VWC <br />Vinyl Wall Covering <br />AXP <br />Access Panel <br />DK <br />Desk <br />GL <br />Glass <br />LS <br />Library Shelving <br />PLYWD <br />Plywood <br />SPEC <br />Specification <br />W <br />West <br />B/ <br />Bottom of <br />DN <br />Down <br />GND <br />Ground <br />LT <br />Light <br />PNL <br />Panel <br />SQ <br />Square <br />W <br />Wide/Width <br />BC <br />Bookcase <br />DR <br />Door <br />GIRT <br />Grout <br />LTG <br />Lighting <br />PNT <br />Paint <br />SS <br />Stainless Steel <br />W/ <br />With <br />BD <br />Board <br />DW <br />Dishwasher <br />GT <br />Glass Tile <br />LTWT <br />Lightweight <br />POL <br />Polished <br />SSM <br />Solid Surface Material <br />W/O <br />Without <br />BET <br />Between <br />DWG(S) <br />Drawing(s) <br />GYP <br />Gypsum <br />MAS <br />Masonry <br />PSI <br />Pound per Square Inch <br />ST <br />Stone <br />W/W <br />Wall to Wall <br />BLDG <br />Building <br />E <br />East <br />HC <br />Hollow Core <br />MATL <br />Material <br />PTD <br />Painted <br />STC <br />Sound Transmission Class <br />WAP <br />Waterproof <br />BLKG <br />Blocking <br />EA <br />Each <br />HCP <br />Handicapped <br />MAX <br />Maximum <br />PTN <br />Partition <br />STD <br />Standard <br />WC <br />Water Closet <br />BLW <br />Below <br />EF <br />Exhaust Fan <br />HD <br />Head <br />MECH <br />Mechanical <br />PTR <br />Printer <br />STL <br />Steel <br />WD <br />Wood <br />BN <br />Bench <br />EJ <br />Expansion Joint <br />HDF <br />High Density Fiberboard <br />MEZZ <br />Mezzanine <br />PVC <br />Polyvinyl Chloride <br />STOR <br />Storage <br />WDB <br />Wood Base <br />BOT <br />Bottom <br />EL <br />Elevation <br />HDWD <br />Hardwood <br />MFR <br />Manufacturer <br />QT <br />Quarry Tile <br />STRUCT <br />Structural/Structure <br />WDW <br />Window <br />BQ <br />Banquette <br />ELEC <br />Electrical <br />HDWR <br />Hardware <br />MID <br />Middle <br />QTY <br />Quantity <br />SUPT <br />Support <br />WEP <br />Weatherproof <br />BRKT <br />lBracket <br />ELEV <br />Elevator <br />HEX <br />Hexagoiri <br />MIN <br />Minimum <br />R <br />Radius <br />SURF <br />Surface <br />WSA <br />Work Station <br />BS <br />I Both Sides <br />EM <br />Emergency <br />HM <br />I Hollow Metal <br />MISC <br />Miscellaneous <br />R <br />Riser(s) <br />SUSP <br />Suspended <br />WT <br />Weight <br />BVL <br />I Beveled <br />ENCL <br />Enclose/Enclosure <br />HORZ <br />lHorizontal <br />ML <br />Match Line <br />RA <br />Return Air <br />SW <br />ISwitch <br />WT <br />Window Treatment <br />STANDARD ABBREVIATIONS <br />MEP / FP Engineer <br />EPSTEIN <br />600 West Fulton <br />Chicago, IL 60661 <br />312.454.9100 <br />Design Architect <br />EPSTEIN <br />600 West Fulton <br />Chicago, IL 60661 <br />312.454.9100 <br />Nestle Waters North America <br />Nestle Waters North America <br />4330 20th Street <br />Zephyrhills, Florida 33542-6703 <br />972.462.3663 <br />4 <br />3 <br />09.18.2013 <br />09.11.2013 <br />ISSUE FOR PERMIT <br />ISSUE FOR BIDS <br />2 <br />1 <br />NO. <br />09.03.2013 <br />08.16.2013 <br />DATE <br />CD REVIEW PACKAGE <br />DID REVIEW PACKAGE <br />REVISIONSASSUANCES <br />� P S T E I N <br />Architecture <br />Chicago <br />Interiors <br />New York <br />Engineering <br />Bucharest <br />Construction <br />Warsaw <br />600 W. Fulton Street <br />Chicago, IL 60661-1259 <br />T 312.454.9100 <br />www.epsteinglobal.com <br />PROJECT NUMBER: <br />12386 <br />PROJECT MANAGER: <br />JK <br />ARCH/ENG: <br />LK <br />SCALE: <br />AS NOTED <br />DRAWN BY: <br />JK <br />CHECKED BY: <br />LK <br />PROJECT INFORMATION <br />CA-001 <br />A. Epstein and Sons International, Inc. All rights reserved. <br />