Laserfiche WebLink
I <br />SEE PLAN <br />SCHEDULED RESINOUS FLOORING <br />AFF <br />SCHEDULED SUSPENDED <br />ACT CEILING SYSTEM <br />ARMSTRONG VTO TRANSITION STRIP <br />EXISTING CARPET <br />SCHEDULED PARTITION <br />SAWCUT EXISTING SLAB AT TRANSITIONS TO <br />PROVIDE MIN Y" THICK BY 1 X" WIDE <br />TAPERED EDGE FOR RESINUOUS FLOORING. <br />6 <br />CEILING TERMINATION DETAIL <br />3 <br />FLOOR TRANSITION DETAIL <br />SCALE 3" 1'-0" <br />somm Ir 10—G" <br />EXISTING WINDOW AND <br />FRAME <br />NEW FURRING PARTITION <br />TYPE B. <br />EXISTING CONCRETE BLOCK <br />EXISTING CONCRETE <br />FLOOR. <br />WALL <br />SCHEDULED RESINOUS <br />FLOORING. <br />Al .: <br />SAWCLIT EXISTING SLAB AT TRANSITIONS TO <br />PROVIDE MIN Y" THICK BY 1 V WIDE <br />TAPERED EDGE FOR RESINUOUS FLOORING. <br />5 <br />SILL/HEAD DETAIL <br />2 <br />LOOR TRANSITION DETAIL <br />NOTE: <br />1 HOUR RATING TO UNDERSIDE OF NON—COMBUSTIBLE CEILING. <br />AT FIRE RATED PARTITIONS, UL RATED ANCHORS AND HOLLOW METAL FRAMES ARE TO BE USED. <br />LINE OF <br />LINE OF STRUCTURE ABOVE <br />STRUCTURE ABOVE <br />% r <br />CONTINUOUS ARE RATED SEALANT, TYP. <br />FIRESTOP ALL VOIDS AT STRUCTURAL <br />CONTINUOUS <br />DECK AND AT ALL PENETRATIONS. <br />RUNNER, TYP. <br />CONTINUOUS STEEL RUNNER FASTENED <br />TO DECK ABOVE, TYP. <br />CID <br />SCHEDULED CEILING <br />F <br />FINISHED CEILING <br />r WHERE SPECIFIED <br />j <br />NOTE: STC RATING SHALL NOT BE <br />COMPROMISED BY DUCT WORK OR <br />ANY OTHER PARTITION PENETRATIONS <br />-' EXISTING CONCRETE <br />BLOCK PARTITION <br />METAL STUDS <br />METAL STUDS <br />/ <br />>G FIRE —RETARDANT TREATED BLOCKING <br />IN WALL, COORDINATE LOCATIONS <br />WITH FURNITURE AND A/V <br />ONE LAYER 5/8" TYPE <br />id X MOISTURE RESISTANT <br />i ONE LAYER 5/8" TYPE "X" <br />MOISTURE <br />RESISTANT GYP. BD. EACH <br />GYP. BD. <br />SIDE <br />/ > SCHEDULED BASE <br />SCHEDULED BASE <br />CONTINUOUS <br />RUNNER, TYP. <br />CONTINUOUS STEEL RUNNER FASTENED <br />CONTINUOUS SEALANT, <br />TYP' <br />TO FLOOR STRUCTURE, TYP. <br />i <br />CONTINUOUS FIRE RATED SEALANT, <br />TYP./ <br />SCHEDULED <br />FLOOR FINISH <br />SCHEDULED FLOOR FINISH <br />T SLABAmmmum_N <br />T SLAB <br />p <br />MARK <br />STUD SIZE <br />STUD GAUGE <br />STUD SPACING <br />WALL <br />THICKNESS <br />INSULATION <br />THICKNESS <br />FIRE RATING/ <br />UL DESIGN NO. <br />STC RATING <br />MARK <br />STUD SIZE <br />STUD GAUGE <br />STUD SPACING <br />WALL <br />THICKNESS <br />INSULATION <br />THICKNESS <br />FIRE RATING/ <br />UL DESIGN NO. <br />STC RATING <br />2-1/2" <br />25 <br />16" O.C. <br />3 1 /8" <br />— <br />_ <br />— <br />3-5/8" <br />25 <br />16" O.C. <br />4-7/8" <br />3" <br />1 HR <br />50 <br />2 <br />- <br />- <br />- <br />2 <br />3 <br />3 <br />4 <br />4 <br />PARTITON TYPE 'B' SCALE:3._1.-D* <br />4 <br />PARTITON TYPE 'A' SCALE:3•-1'—O' <br />1 <br />PARTITION TYPES <br />9G11.E:3" 1 <br />MEP / FP Engineer <br />EPSTEIN <br />600 West Fulton <br />Chicago, IL 60661 <br />312.454.9100 <br />Design Architect <br />EPSTEIN <br />600 West Fulton <br />Chicago, IL 60661 <br />312.454.9100 <br />Nestle Waters North America <br />Nestle Waters North America <br />4330 20th Street <br />Zephyrhills, Florida 33542-6703 <br />972.462.3663 <br />Fj;e§s-t_1!'7eq7 <br />wmers <br />NORTH AMERICA <br />a <br />PARTITION TYPE NOTES <br />1. WHERE FIRE RATED PARTITIONS ARE SPECIFIED, ALL <br />COMPONENTS OF THE INSTALLATION SHALL BE <br />COMPATIBLE WITH THE FIRE RATING DESIGN SPECIFIED. <br />2. ALL FIRE RATED PARTITIONS AND SMOKE PARTITIONS <br />SHALL BE FULLY SEALED TO THE STRUCTURE ABOVE. <br />ALL PENETRATIONS IN FIRE RATED PARTITIONS AND <br />SMOKE PARTITIONS SHALL BE FULLY FIRE STOPPED <br />WITH UL RATED MATERIALS. <br />3. PARTITION REINFORCING/BLOCKING SHALL BE PROVIDED <br />AT ALL LOCATIONS WHERE WALL MOUNTED MILLWORK, <br />CABINETS, EQUIPMENT, GRAB BARS, CLOSET RODS, AND <br />ACCESSORIES ARE SHOWN ON THE PROJECT DRAWINGS. <br />4. MOISTURE RETARDANT GYPSUM BOARD SHALL BE <br />INSTALLED ON ALL WALLS IN LAB. <br />5. ALL WOOD BLOCKING AND PLYWOOD SHALL BE FIRE <br />RETARDANT TREATED. <br />6. REFER TO THE FLOOR PLANS, ELEVATIONS, FINISH PLAN <br />AND FINISH SCHEDULE FOR PARTITION FINISH <br />TREATMENTS. <br />7. COORDINATE ALL REQUIRED GYP. BD. CONTROL JOINT <br />LOCATIONS WITH ARCHITECT. <br />4 <br />09.18.2013 <br />ISSUE FOR PERMIT <br />3 <br />09.11.2013 <br />ISSUE FOR BIDS <br />2 <br />09.03.2013 <br />CD REVIEW PACKAGE <br />1 <br />08.16.2013 <br />DID REVIEW PACKAGE <br />NO. <br />DATE <br />REVISIONS/ISSUANCES <br />� P S T E I N <br />Architecture <br />Chicago <br />Interiors <br />New York <br />Engineering <br />Bucharest <br />Construction <br />Warsaw <br />600 W. Fulton Street <br />Chicago, IL 60661-1259 <br />T 312.454.9100 <br />www.epsteinglobal.com <br />PROJECT NUMBER: 12386 <br />PROJECT MANAGER: JK <br />ARCH/ENG: <br />SCALE: AS NOTED <br />DRAWN BY: JK <br />CHECKED BY: <br />PARTITION TYPES <br />A-801- <br />A. Epstein and Sons Intemational, Inc. All rights reserved. <br />