STRUCTURAL STEEL PAINTING STRUCTURAL STEEL ABBREVIATIONS <br />1. <br />UNLESS OTHERWISE NOTED, HOLLOW STRUCTURAL TUBE SHAPE MEMBERS SHALL BE ASTM <br />1. <br />ALL PAINTING SHALL BE COORDINATED WITH THE OWNER'S REPRESENTATIVE AND PERFORMED IN <br />& <br />AND <br />A500 GRADE B. STEEL PLATES AND ANGLES SHALL BE ASTM A36. <br />ACCORDANCE WITH MANUFACTURER'S PRINTED INSTRUCTIONS. THE FINAL SURFACE SHALL BE SMOOTH <br />% <br />PERCENT <br />AND EVEN. DRIPS, RUNS, OR SAGS SHALL NOT BE ACCEPTABLE. <br />± <br />PLUS OR MINUS <br />2. <br />STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED, AND ERECTED IN ACCORDANCE WITH THE <br />ACI <br />AMERICAN CONCRETE INSTITUTE <br />FIFTEENTH EDITION STANDARDS AND SPECIFICATIONS OF THE AMERICAN INSTITUTE OF STEEL <br />2, <br />STRUCTURAL STEEL SHALL BE CLEANED IN COMPLIANCE WITH STEEL STRUCTURES PAINTING COUNCIL <br />AISC <br />AMERICAN INSTITUTE OF STEEL CONSTRUCTION <br />CONSTRUCTION. <br />SP10 (NEAR WHITE METAL BLAST CLEANING). OIL OR GREASE SHALL BE REMOVED BY SOLVENT <br />ASTM <br />AMERICAN SOCIETY FOR TESTING AND MATERIALS <br />CLEANING IN COMPLIANCE WITH SSPC-SP1 PRIOR TO BLAST CLEANING AND AFTERWARDS AS <br />@ <br />AT <br />3. <br />ALL SHARP CORNERS OF STEEL EXPOSED TO PERSONNEL SHALL BE ROUNDED. <br />REQUIRED, ALL WELD FLUX AND SPLATTER SHALL BE COMPLETELY REMOVED IN COMPLIANCE WITH <br />AWS <br />AMERICAN WELDING SOCIETY <br />SSPC-SP3, ALL SHARP EDGES AND PROJECTIONS SHALL BE GROUND SMOOTH. <br />BLDG <br />BUILDING <br />4. <br />STEEL FABRICATOR SHALL FURNISH SHOP DRAWINGS OF ALL STRUCTURAL STEEL TO ENGINEER <br />BM <br />BASE MIX <br />FOR APPROVAL PRIOR TO FABRICATION. <br />3. <br />IMMEDIATELY AFTER SURFACE PREPARATION, ALL STEEL SURFACES SHALL RECEIVE A PRIMER COAT <br />BOT <br />BOTTOM <br />APPROVED BY THE OWNER'S REPRESENTATIVE. IN NO CASE SHALL NEWLY CLEANED STEEL GO <br />B/ <br />BOTTOM OF <br />5. <br />MODIFICATIONS OR CHANGES TO THE STRUCTURAL STEEL AS NOTED ON THESE DRAWINGS CAN <br />UNPRIMED OVERNIGHT. USE THE FOLLOWING PAINT PRIMERS OR APPROVED EQUAL: <br />4. <br />CENTERLINE <br />NOT BE MADE DURING DETAILING, FABRICATION, OR CONSTRUCTION WITHOUT PRIOR WRITTEN <br />CO <br />CLEANOUT <br />APPROVAL BY THE ENGINEER OF RECORD. <br />a. CARBOLINE: CARBOCOAT 2900 (MINIMUM 2 MIL DRY FILM THICKNESS) <br />CLR <br />CLEAR <br />b, SHERWIN WILLIAMS MACROPDXY 646 (MINIMUM 4 MIL DRY FILM THICKNESS) <br />CONT'D <br />CONTINUED <br />6. <br />ERECTOR SHALL PROVIDE ALL TEMPORARY SHORING AND BRACING NEEDED FOR STABILITY <br />CJ <br />CONTROL JOINT <br />UNTIL STRUCTURAL STEEL AND NEW EQUIPMENT IS COMPLETELY INSTALLED. ERECTOR IS <br />4. <br />THE PRIMED SURFACE SHALL RECEIVE AN INTERMEDIATE COAT APPROVED BY THE OWNER'S <br />RESPONSIBLE FOR THE STABILITY OF THE STRUCTURAL FRAMING DURING CONSTRUCTION. <br />REPRESENTATIVE. USE THE FOLLOWING PAINT SYSTEMS OR APPROVED EQUAL, <br />LYVINYL CHLORIDE <br />PROPER ERECTION SEQUENCING SHALL BE USED TO ENSURE FRAME STABILITY THROUGHOUT <br />CRS <br />CATIONIC RAPID SET <br />CONSTRUCTION, <br />a. CARBOLINE: CARBOTHANE 133 HB (MINIMUM 5 MIL DRY FILM THICKNESS) <br />CRSI-MSP <br />CONCRETE REINFORCING STEEL INSTITUTE -MANUAL OF STANDARD PRACTICE <br />b. SHERWIN WILLIAMS MACROPDXY 646 (MINIMUM 4 MIL DRY FILM THICKNESS) <br />DEMO <br />DEMOLITION <br />DIA, 0 <br />DIAMETER <br />STRUCTURAL STEEL CONNECTIONS <br />5. <br />THE INTERMEDIATE COAT SHALL RECEIVE A FINAL COAT APPROVED BY THE OWNER'S <br />REPRESENTATIVE. USE THE FOLLOWING PAINT SYSTEMS OR APPROVED EQUAL: <br />DWG <br />DWV <br />DRAWING <br />DRAIN WASTE VENT <br />(E) <br />EXISTING <br />a. CARBOLINE: CARBOTHANE 133 HB (MINIMUM 5 MIL DRY FILM THICKNESS) <br />ETC <br />ETCETERA <br />1. <br />UNLESS OTHERWISE NOTED ON THE DRAWINGS, ALL BEAM CONNECTIONS SHALL BE AISC "SIMPLE <br />(MINIMUM 3 (MMIL DRY FILM <br />b. SHERWIN WILLIAMS 2 N O S IPOLYURETHANE 50 I SO HI -SOLIDS <br />EL <br />EQ <br />ELEVATIONR <br />EQUAL <br />SHEAR CONNECTIONS". THE DETAILER SHALL DESIGN THE CONNECTIONS FOR THE INDICATED <br />THICKNESS) <br />EW <br />EACH WAY <br />SHEAR AND AXIAL LOADS SHOWN ON THE DRAWING, WHERE NO LOADS ARE INDICATED, THE <br />FD <br />FLOOR DRAIN <br />DETAILER SHALL DESIGN BEAM CONNECTIONS PER THE FOLLOWING TABLE: <br />6, <br />STEEL ERECTOR IS RESPONSIBLE FOR TOUCH UP OF ALL PAINT BLEMISHES. BLEMISHES INCLUDE: WELD <br />FIN FLOOR <br />FINISHED FLOOR <br />BURNS, WELD SCARS, ABRASIONS, BOLTS, FRAYING SURFACES AT BOLTED CONNECTIONS, AND <br />DEPTH OF BEAM <br />12-14 <br />DAMAGE DURING SHIPPING. ALL TOUCH UP SURFACES SHALL BE CLEANED IN ACCORDANCE WITH <br />FLR <br />FLOOR <br />SSPC-SP3 (POWER TOOL CLEANING). ALL DAMAGED LAYERS OF PAINT SHALL BE REAPPLIED PER <br />IM <br />INTERMEDIATE MIX <br />ROWS OF BOLTS <br />3 <br />MANUFACTURER'S PRINTED INSTRUCTIONS. <br />INV <br />INVERT <br />SHEAR FORCE IN <br />IPS <br />IRON PIPE SIZE <br />WELDS OR BOLTS (KIPS) <br />63 <br />7. <br />THE VOLATILE ORGANIC COMPOUNDS (VOC) OF ALL PAINT AND PROTECTIVE COATINGS ON THIS <br />KSI <br />KIPS PER SQUARE INCH <br />PROJECT SHALL NOT EXCEED THE AMOUNT OF VOC'S APPROVED BY THE STATE, LOCAL AUTHORITIES, <br />LG <br />LONG <br />2. <br />SHOP CONNECTIONS SHALL BE WELDED UNLESS NOTED OTHERWISE. FIELD CONNECTIONS SHALL <br />AND EPA GUIDELINES WITHIN THE AREA OR ZONE IN WHICH THE COATING IS APPLIED. <br />MAX <br />MIN <br />MAXIMUM <br />MINIMUM <br />BE AS NOTED ON DRAWINGS, FIELD CONNECTIONS TO EXISTING STRUCTURES MAY BE FIELD <br />MPH <br />MILES PER HOUR <br />WELDED. <br />NSF <br />NATIONAL SANITATION FOUNDATION <br />SANITARY <br />SEWER <br />DRAIN <br />NO./# <br />NUMBER <br />3. <br />ALL GUSSET PLATES AND CONNECTION ANGLES SHALL BE MINIMUM %" THICKNESS. <br />OC <br />ON CENTER <br />4. <br />SHOP OR FIELD SPLICES BETWEEN SUPPORTS WILL NOT BE ALLOWED WITHOUT PRIOR <br />1. <br />PIPE SHALL BE MANUFACTURED FROM VIRGIN RIGID CPVC (CHLORINATED POLYVINYL CHLORIDE) VINYL <br />OPP <br />OPPOSITE <br />APPROVAL BY THE ENGINEER. <br />COMPOUNDS WITH A CELL CLASS OF 24448 AS IDENTIFIED IN ASTM D1784. <br />PCF <br />POUNDS PER CUBIC FOOT <br />R <br />PLATE <br />5. <br />3 <br />UNLESS OTHERWISE NOTED, BOLTS SHALL BE DOMESTIC MANUFACTURED /" DIAMETER HIGH <br />2. <br />CPVC SCHEDULE 80 PIPE SHALL BE IRON PIPE SIZE (IPS) CONFORMING TO ASTM F441, <br />PSF <br />PSI <br />POUNDS PER SQUARE FOOT <br />POUNDS PER SQUARE INCH <br />STRENGTH ASTM A325-N (BEARING TYPE) MECHANICALLY DEPOSITED GALVANIZED PER ASTM <br />REF <br />REFERENCE <br />B695. THREADS ARE PERMITTED IN THE SHEAR PLANE, UNLESS OTHERWISE NOTED. <br />3. <br />INJECTION MOLDED CPVC SCHEDULE 80 DWV FITTINGS SHALL CONFORM TO ASTM F439. <br />REQ'D <br />REQUIRED <br />6. <br />BOLT AND NUT ENGAGEMENT SHALL CONFORM TO THE FOLLOWING: <br />4. <br />PIPE AND FITTINGS SHALL CONFORM TO NSF INTERNATIONAL STANDARD 14. <br />RFI <br />REQUEST FOR INFORMATION <br />SAN <br />SANITARY SEWER <br />a. MINIMUM ENGAGEMENT: DEPTH OF NUT PLUS 2 THREADS <br />SCH <br />SCHEDULE <br />b. MAXIMUM ENGAGEMENT: DEPTH OF NUT PLUS Y2" <br />5. <br />INSTALLATION OF CPVC PIPE SHALL COMPLY WITH THE LATEST INSTALLATION INSTRUCTIONS <br />PUBLISHED BY THE MANUFACTURER AND SHALL CONFORM TO ALL APPLICABLE PLUMBING, FIRE, AND <br />SIM <br />SIMILAR <br />7. <br />GALVANIZE NUTS AND WASHERS IN ACCORDANCE WITH ASTM 6695. <br />BUILDING CODE REQUIREMENTS. <br />SS <br />SSPC <br />STAINLESS STEEL <br />SOCIETY FOR PROTECTIVE COATINGS <br />8. <br />ONE SIDED CONNECTIONS MAY NOT BE USED UNLESS SPECIFICALLY SHOWN ON THE DRAWING OR <br />6. <br />BURIED PIPE SHALL BE INSTALLED IN ACCORDANCE WITH ASTM D2321 AND ASTM F1668. <br />STD <br />T/ <br />STANDARD <br />TOP OF <br />APPROVED BY THE ENGINEER, WHERE ECCENTRIC CONNECTIONS ARE USED THE COMPONENTS OF <br />TYP <br />TYPICAL <br />THE CONNECTION SHALL BE DESIGNED FOR ALL ECCENTRIC FORCES. <br />7. <br />SOLVENT CEMENT JOINTS SHALL BE MADE IN A TWO-STEP PROCESS WITH PRIMER CONFORMING TO <br />UNO <br />UNLESS NOTED OTHERWISE <br />ASTM F656 AND SOLVENT CEMENT CONFORMING TO ASTM F493. <br />VDOT <br />VIRGINIA DEPARTMENT OF TRANSPORTATION <br />9. <br />MINIMUM BOLTED CONNECTIONS SHALL BE TWO BOLTS, UNLESS OTHERWISE NOTED. <br />W/ <br />WITH <br />8. <br />THE SYSTEM SHALL BE PROTECTED FROM CHEMICAL AGENTS, FIRE -STOPPING MATERIALS, THREAD <br />10. <br />CONNECTIONS SHALL BE DESIGNED AND DETAILED SO ALL FORCE COMPONENTS WILL BE <br />SEALANT, PLASTICIZED -VINYL PRODUCTS OR OTHER AGGRESSIVE CHEMICAL AGENTS NOT <br />WP <br />WORK POINT <br />TRANSMITTED DIRECTLY THROUGH THE WORK POINTS OF THE INTERSECTING MEMBERS, THE <br />COMPATIBLE WITH CPVC COMPOUNDS. <br />CONNECTIONS SHALL BE DESIGNED FOR ALL RESULTING ECCENTRICITIES. <br />9. <br />THE SYSTEM SHALL BE HYDROSTATICALLY TESTED AFTER INSTALLATION. <br />11. FOR CONNECTIONS OF STEEL MEMBERS NOT SPECIFICALLY ADDRESSED BY THESE GENERAL <br />NOTES OR DRAWINGS, PROVIDE FILLET WELDS AT ALL CONTACT JOINTS BETWEEN STEEL <br />MEMBERS SUFFICIENT TO DEVELOP THE TENSILE STRENGTH OF THE WEAKEST MEMBER AT THE <br />JOINT. <br />12. SHOP AND FIELD WELDING SHALL BE IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY <br />D1.1-11 "STRUCTURAL WELDING CODE - STEEL". ALL WELDING SHALL BE PERFORMED BY AWS <br />QUALIFIED WELDERS. <br />13. ELECTRODES FOR WELDED CONNECTIONS SHALL BE E70XX. <br />14. MINIMUM WELD SIZE SHALL BE 316" UNLESS THINNER PART TO BE JOINED REQUIRES A LARGER <br />WELD SIZE IN ACCORDANCE WITH AISC. TABLE J2.4. <br />15. MINIMUM WELDED CONNECTION SHALL HAVE THE STRENGTH OF A TWO -BOLT CONNECTION. <br />FIELD WELD NOTES: <br />1. SURFACES TO RECEIVE WELDING SHALL BE THOROUGHLY CLEANED OF ALL GREASE, PAINT, <br />RUST, ETC., BY USING GRINDER TO EXPOSE CLEAN BASE METAL FOR A DISTANCE OF 2" FROM <br />EACH SIDE OF THE OUTSIDE LINES OF THE WELD. <br />2. OWNER'S ENGINEER SHALL APPROVE SURFACE PREP PRIOR TO PLACING WELD. <br />3. VISUALLY INSPECT ALL WELDS PER AWS. <br />4. WELDS NOT MEETING AWS STANDARDS SHALL BE CORRECTED PER OWNER'S ENGINEERS <br />DIRECTION AND AT NO EXPENSE TO THE OWNER. <br />\\\\\\¢NANO IT //I 'Professional Certification. I hereby certify that these <br />documents were prepared or approved by me, and that <br />No. 90224 I am a duly licensed professional engineer under the <br />* * *E laws of the <br />yip O D 2\� State of Florida, License No. 90224 <br />1 <br />ADDED ABBREVIATION FOR CONTROL JOINT <br />CDC <br />01/29/21 <br />Nl L ��\\\ Expiration Date: 2-08-23 <br />0 <br />ISSUE FOR CONSTRUCTION <br />CDC <br />01/22/21 <br />I <br />c/J91z/ <br />REV, <br />DESCRIPTION <br />DRWN <br />APPR <br />DATE <br />REV. <br />DESCRIPTION <br />DRWN <br />APPR <br />DATE <br />DRAWING NO, <br />REFERENCE DRAWING <br />DRAWN DATE <br />CDC 01/22/21 <br />CHECKED DATE <br />DEC 01/22/21 <br />,- <br />SUPERVISOR DATE <br />ALLIANCE <br />AJD 01/22/21 <br />Baltimore, MD Newport News, VA <br />(410)636-9555 (757)599-3300 <br />PROJECT ENGINEER DATE <br />LAS 01/22/21 <br />Richmond, VA <br />(804)275-1400 <br />OWNERS APPROVAL DATE <br />SCALE <br />NESTLE WATERS AS NOTED <br />qT PROJECT NO. <br />ZEPHYRHILLS, FL 2002610040 <br />FILENAME <br />STRUCTURAL 21DRAWING 0. REV, <br />GENERAL NOTES <br />2160040-S002 1 <br />