My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
4912 & 4916 8th St
Zephyrhills
>
Building Department
>
Building Plans
>
4912 & 4916 8th St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 9:45:13 AM
Creation date
2/18/2025 3:20:29 PM
Metadata
Fields
Template:
Building Plans
Street #
4912 & 4916
Location
8th St
Contractor
J Bryant Construction Inc
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
— /0 <br />......... ... ................... . ......... ....... ....................................... <br />..................... ............................................................ <br />ELECTRICAL NOTES <br />1.', ALL CIRCUITS AND EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH THE APPROPRIATE <br />ARTICLES OF THE NATIONAL ELECTRICAL CODES (NEC). <br />2A WHEN LIGHT FIXTURES ARE INSTALLED IN CLOSETS THEY SHALL BE SURFACE MOUNTED OR RECESSED. <br />,INCANDESCENT FIXTURES SHALL HAVE COMPLETELY ENCLOSED LAMPS. SURFACE MOUNTED <br />INCANDESCENT FIXTURES SHALL HAVE A MINIMUM CLEARANCE OF 12 INCHES AND ALL OTHER FIXTURES <br />SHALL HAVE A MINIMUM CLEARANCE OF 6 INCHES FROM " STORAGE AREA" AS DEFINED BY NEC 410-8 (a) <br />3. WHEN WATER HEATERS ARE INSTALLED THEY SHALL BE PROVIDED WITH READILY ACCESSIBLE <br />DISCONNECTS ADJACENT TO THE WATER HEATERS SERVED. THE BRANCH CIRCUIT SWITCH OR CIRCUIT <br />BREAKER SHALL BE PERMITTED TO SERVE AS THE DISCONNECTING MEANS ONLY WHERE THE SWITCH <br />OR CIRCUIT BREAKER IS WITHIN SIGHT FROM THE WATER HEATER OR IS CAPABLE OF BEING LOCKED <br />IN THE OPEN POISON. <br />4. HVAC EQUIPMENT SHALL BE PROVIDED WITH READILY ACCESSIBLE DISCONNECTS ADJACENT TO THE <br />EQUIPMENT SERVED. A UNIT SWITCH WITH A MARKED " OFF " POSITION THAT IS A PART OF THE HVAC <br />EQUIPMENT AND DISCONNECTS ALL UNGROUNDED CONDUCTORS SHALL BE PERMITTED AS THE <br />DISCONNECTING MEANS WHERE OTHER DISCONNECTING MEANS ARE ALSO PROVIDED BY A READILY <br />ACCESSIBLE CIRCUIT BREAKER. <br />5. PRIOR TO ENERGIZING THE ELECTRICAL SYSTEM THE INTERRUPTING RATING OF THE MAIN BREAKER <br />MUST BE DESIGNED AND VERIFIED AS BEING IN COMPLIANCE WITH SECTION 110-9 OF THE NEC BY <br />LOCAL ELECTRICAL CONSULTANT. <br />6. EXTERIOR LIGHTS NOT INTENDED FOR 24 HOUR USE AND SHALL BE CONNECTED TO A PHOTOCELL OR <br />TIMER. <br />7. ALL RECEPTACLES INSTALLED IN WET LOCATIONS (EXTERIOR) SHALL BE IN WEATHER PROOF (W.P.) <br />ENCLOSURES. THE INTEGRITY OF WHICH IS NOT AFFECTED WHEN AN ATTACHMENT PLUG CAP IS <br />INSERTED OR REMOVED. <br />8. WHEN NOT SHOWN ON THE PLANS PROVISIONS FOR EXIT DISCHARGE LIGHTING (INCLUDING EXIT <br />DISCHARGE EMERGENCY LIGHTING) ARE DESIGNED BY OTHERS AND THE RESPONSIBILITY OF THE <br />BUILDINGS OWNER AND SUBJECT TO LOCAL JURISDICTION APPROVAL. <br />SM <br />OKE ALARM NOTES <br />NOTE: SMOKE ALARMS SHALL NOT BE INSTALLED IN THE FOLLOWING LOCATIONS UNLESS THIS WOULD PREVENT <br />PLACEMENT OF A SMOKE ALARM IN A LOCATION REQUIRED BY SECTION 907.2.11.1 OR 907.2.11.2: <br />1. IONIZATION SMOKE ALARMS SHALL NOT BE INSTALLED LESS THAN 20 FEET HORIZONTALLY FROM A <br />PERMANENTLY INSTALLED COOKING APPLIANCES. <br />2. IONIZATION SMOKE ALARMS WITH AN ALARM -SILENCING SWITCH SHALL NOT BE INSTALLED LESS THAN 10 <br />FEET HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. <br />3. PHOTOELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED LESS THAN 6 FEET HORIZONTALLY FROM A <br />PERMANENTLY INSTALLED COOKING APPLIANCE. <br />NOTE: ALL SMOKE ALARMS WITHIN THE SLEEPING UNIT OR DWELLING UNIT IN GROUP R OR I-1 OCCUPANCIES SHALL <br />BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE OTHER <br />ALARMS IN THE INDIVIDUAL UNIT. PHYSICAL CONNECTION OF SMOKE ALARMS SHALL NOT BE REQUIRED WHERE <br />LISTED WIRELESS ALARMS ARE INSTALLED AND ALL ALARMS SOUND UPON ACTIVATION OF ONE ALARM. THE ALARM <br />SHALL BE CLEARLY AUDIBLE IN ALL BEDROOMS OVER BACKGROUND NOISE LEVELS WITH ALL INTERVENING DOORS <br />CLOSED. (FBC 907.2.11.5) <br />NOTE: SINGLE OR MULTI -STATION SMOKE ALARMS SHALL BE INSTALLED AND MAINTAINED AT ALL OF THE FOLLOWING <br />LOCATIONS: <br />1.ON THE CEILING OR WALL OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF <br />BEDROOMS.. <br />2.IN EACH ROOM USED FOR SLEEPING PURPOSES. <br />3.IN EACH STORY WITHIN A DWELLING UNIT, INCLUDING BASEMENTS BUT NOT INCLUDING CRAWL SPACES AND <br />UNINHABITABLE ATTICS. IN DWELLINGS OR DWELLING UNITS WITH SPLIT LEVELS AND WITHOUT AN INTERVENING <br />DOOR BETWEEN THE ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR <br />THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE FULL STORY BELOW THE <br />UPPER LEVEL. (FBC 907.2.9.2) (FBC 907.2.11.2) <br />ELECTRICAL LEGEND <br />IQ <br />DUPLEX RECEPT @ 16" A.F.F. <br />DUPLEX RECEPT @ 42" A.F.F. <br />QUAD RECEPT @ 16" A.F.F. <br />220 VOLT RECEPTACLE <br />®G.F.I. <br />DUPLEX RECEPTACLE <br />W/ WEATHERPROOF COVER <br />Q <br />PHONE JACK @ 16" A.F.F. <br />PHONE JACK @ 42" A.F.F. <br />V <br />DATA OUTLET @ 16" A.F.F. <br />® <br />24"x24" SUPPLY AIR REGISTER <br />® <br />24"x24" RETURN AIR <br />WALL MOUNTED SWITCH <br />® <br />OCCUPANCY SENSOR <br />Oo O <br />EEMAX WATER HEATER <br />sD <br />SMOKE DETECTOR <br />HD <br />AT DETECTOR HE <br />ccry <br />SEC CCTV CAMERA <br />0 CEILING MOUNT EXHAUST FAN <br />® EXHAUST FAN / LIGHT COMBO <br />EMERGENCY LIGHTING <br />4® EXIT SIGNAGE - DIRECTIONAL <br />WATER PROOF PORCH LIGHT 60W. <br />MAXIMUM WITH PHOTO CELL <br />4&A EMERGENCY LIGHT/ EXIT COMBO <br />INCANDESCENT LIGHT 15/25W MAX <br />® FLUORESCENT FIXTURE <br />J❑ ELECTRICAL JUNCTION BOX <br />QT WALL MOUNTED THERMOSTAT <br />® FIRE ALARM STROBE <br />FIRE ALARM HORN STROBE <br />FIRE ALARM PULL STATION <br />® MONOXIDE DETECTOR <br />MD <br />SEC MOTION DETECTOR <br />R <br />C <br />KF SEC KEY FOB ENTRY <br />w <br />0 2 <br />0 <br />J <br />LL <br />z (ii p _N <br />o 0 a0 <br />M <br />Q N LJL <br />W S <br />ao <br />"l �Z�Zul <br />N <br />° M <br />W Q W ao <br />_D J N <br />Uj co <br />Lo <br />Z <br />L U <br />LU <br />wU_UL <br />N Z <br />C� <br />rYM <br />�Q <br />Q Z <br />LLI <br />0 J <br />Q LL <br />0o <br />CD <br />OZ <br />CD <br />co <br />F— <br />¢ <br />I— <br />::) <br />W <br />ZL]Ij W <br />Z <br />W <br />m � <br />0Q <br />L1_I _3 <br />110 <br />a <br />OU) <br />w <br />L0 <br />O <br />N <br />1..� <br />w <br />z <br />J <br />Z <br />pWLO <br />N <br />O <br />I-WMa <br />0O <br />� <br />U <br />�� <br />F- <br />W=JW <br />z <br />00 <br />OO <br />U0.) <br />. <br />=W <br />O <br />O <br />Z <br />W <br />z <br />JWO <br />N <br />O_ <br />O <br />O <br />ann"yn <br />Oe'-'StSTE'q <br />w ' 24575 i ¢ <br />9 t5 STATE OF £ W a <br />f� pGOR��� <br />'AL <br />L <br />igitally signed by <br />R bert'T Haug i <br />Da 2021.06.10 <br />16:35: - ° <br />W N m aD <br />w u') O LLI o <br />Z (� � M 2 N <br />Z 2Q* (6 W <br />W O W O <br />�FpU) <br />Z <br />LL w wOU <br />J m <br />0 0 LLl Z Y <br />W <br />W <br />U <br />z a F w ro <br />Ov o o U O <br />SHEET NO. <br />1001 <br />........................ ......._................ .................................. _.................... ............ __............................_.__.._........................._....._ ......... . <br />O <br />U) © COPYRIGHT 2021 - ELEMENT ARCHITECTURAL VISUALIZATION <br />
The URL can be used to link to this page
Your browser does not support the video tag.