My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5203 17th St
Zephyrhills
>
Building Department
>
Building Plans
>
5203 17th St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 8:52:19 AM
Creation date
2/18/2025 3:20:41 PM
Metadata
Fields
Template:
Building Plans
Street #
5203
Location
17th St
Contractor
Kerns Family
Building Plans - Permit #
19911
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br />2-4-1-0 <br />Framing„ Lavout Notes: <br />a' - o'' 81- o'' 5' - o'' <br />1 Framing layatt drawn by Denial M. Ossman UraftV Serves, kw-- is a schetnabc <br />5 Truss design drawings shall be prepared in accordance to and with section <br />t 1 <br />i spewion only. It is the responsibility of the General Contactor to make a field <br />R802.1.6.1. These documents stwA be provided by the truss mar iscluore at time of truss <br />inspection to verify "ALL" existing field conditions including accuracy in dimensions with <br />delivery and approved by the budding official prior to the installation of the roof truss.% <br />• <br />proposed plans. Gerieral Contractor VUST" certify in writing (the tune and date) that <br />(See code section items 1-13). <br />this field inspection was conducted on and submitted to truss manufacture. If this field <br />"NOT" <br />6 This plan as indicated is diagrammatical in nature for permit and contract purposes only. <br />C4 <br />inspection was done prior to giving said plans to the truss manufacture, then the <br />"GENERAL <br />Any revisions as required by the truss company's engineer as indk ted on truss company's <br />CONTRACTOR WILL BE HELD LIABLE FOR ALL COST OF ANY / ALL <br />seated drawings shall superseded this drawing. This also includes truss company's <br />I <br />I <br />MISTAKES" on trusses that are constructed for said project. Daniel M. <br />Ossnrtan Draittrrg Service, Inc. "VNLL NOT HELD LIABLE' far errors made on arrttr <br />specified hurricane and other anchors supersede one shown on this drawing. <br />I Indicates 1 - #5 vert rebar in a <br />conc. masonry block cell filled and I <br />framing (floor or roof) truss layouts. <br />MUST with section 905.2.2, 905.2.4.1 and <br />7 if shingles are being used, shingles comply <br />tamped Solid with conc., hooked I <br />( f <br />2 Upon receivi said plans from the General Contractor the truss roan skxAure <br />ng <br />table R - 905.2.6.1 for wind resistance, FBC residential code 6th edition (2017) residential. <br />into the bond beam above and the <br />"MUST" make a their "OVYW field � to "DOUBLE CHECK" all exisift field <br />8 CONTRACTOR, MUST COORDN�AT>E WITH TRUSS MANUFACTURE FOR ALL VAULTED, TRAY, <br />v <br />I I minconcla (a splice �kwv with a 25„ <br />p I <br />cam, roof slopes, overhangs, and dimensions prior to the manufiactt" of any / all <br />FLAT AND OR OTHER C�MMi TYPES. CONTRACTOR M 1N19% � FOR THE <br />� <br />I <br />trusses. Truss "MUST' certify (the time and dale) that this field insiection <br />EXTERIOR WALL CONSTRUCTION METHOD WHERE A GABLE END M CONSTRUCTED. <br />I I <br />was conducted on by their company. This certification must be given to the General <br />ALL EXTERIOR WALLS MUST COMPLY WITH THE FBC RESIDENTIAL CODE STH EDITION <br />- <br />I <br />Contractor in westing prior to the manufacturing of any / all trusses on said project. <br />. <br />(2017) RESIDENTIAL, CHAPTER S, FOR WALL CONSTRUCTION METHODS. SEE ADDITIONAL <br />Q <br />I <br />3 All thickened slabs /footing on foundation plan are located according to the schematic <br />ATTACHED STRUCTURAL SHEETS FOR GABLE END BRACING <br />RACG DETAILS. DAIBEL M. OSSMAN <br />DRAFTING SERVICE AND ARCHITECT WHO SIGNED I SEALED THE PLANS, ASSUMES NO <br />.. ' <br />— Pour new 4" concrete slab with min. 3,000 p.s.i ( I <br />fibermesh or 11 Opt/1 4,1 conc. slab w/ 6 x 6 x 10 x 10 <br />truss layout drawn by Daniel M. Ossman Drafting Service, Inc. Only truss manufacture <br />RESPONSIBILITY DUE TO NEGLIGENCE OF THE CONTRACTORS FAILURE TO FOLLOW <br />N <br />w.w.m. over 6 mil. vapor barrier over termite <br />can change these locations due to truss bearing points and "MUST' notify General <br />THE BUILDING CODE FOR GABLE END CONSTRUCTION. <br />I treated and compacted clean fill. <br />Contractor of these changes as soon as possible. <br />ge poss <br />I <br />4 All hurricane truss straps specified un on said project are to be used less otherwise <br />"Simpson <br />specified by truss manufacture. All hurricane straps specified are Strong Tie" <br />0 <br />l I I <br />( or equal ), unless noted otherwise. Only truss manufacture can change any / or all <br />buss straps that are specified on truss layout drawn by Daniel M. Ossman Drafting <br />I I <br />Service, Inc. Truss manufacture must first notify General Contractor in writing of these <br />Indicated either a door or window <br />changes as soon as possible. <br />I location (typ).L <br />I <br />0 <br />81- 0'' a'- o" ' air 00 <br />N1 <br />241. 011 <br />It is the responsible of the General Contractor to make a field <br />inspection to verify all existing field conditions and measurements <br />with proposed plans for accuracy, before distributing plans to any <br />and all trades. General Contractor will be held liable if these <br />inaccuracies are "NOT" submitted in writing to Daniel M. Ossman <br />Drafting Service, Inc. before the distribution of plans. Daniel M. <br />Ossman Drafting Service, Inc. "WILL NOT" be held liable for any <br />inaccuracies in dimensions with existing field conditions or other <br />trades on proposed plans. <br />FOUNDATION PLAN <br />0 <br />10" x 20" conc. ftg. w/ <br />3 - #5 rebars cont. w/ a <br />8" x 8" x16" conc block <br />stemwall above or "opt." <br />20" x 2011 mono ftg. w/ <br />3 - #5 rebars cant. <br />ct' <br />N <br />SCALE: 1/4" = 1' - 0' <br />wing- r.ItrrVIP- D <br />24' 0 ,. <br />FLOOR FRAMING LAYOUT <br />� EFL�T'(,C�OG <br />P j <br />SCALE: 1 /4" = 1' - 0" <br />REVISIONS <br />NO I DATE I DESCRIPTION <br />o e <br />P V <br />a <br />! a <br />G v <br />�•' 1 � a a <br />rz <br />v <br />v <br />O U �- <br />a w <br />•=1 A <br />4)m <br />T== <br />v- <br />_ O <br />C <br />2L'o �+ <br />Cc kU 2 M <br />M CO W 004 <br />p C CD <br />i*-' M O <br />C k4 O (0 'a � tp <br />C U++ E < m <br />C U 6 M <br />m <br />t0 .0 C tj) "0 o <br />N LL. <br />C Co L 1 `p <br />'+.- <br />t3 t3 <br />E C-r--5'o m E <br />V o 0- <br />2 (D Cn <br />>4 >Q0 <br />L <br />o 2:, 7 � _ ED 1 <br />SEE t2 (" <br />aD <br />��0'o Moro <br />t <br />a1 C L r C I-- O <br />r=0 N 6.i va <br />N <br />LO <br />CM <br />Z VJ <br />Q •0 <br />CL <br />LL <br />r� C,e) L <br />V L <br />Z �� <br />0 Lid N <br />J <br />D <br />m <br />c� <br />00 <br />Q <br />JOB NO. <br />5203 17TH STREET <br />DATE <br />APRIL 28, 2018 <br />DRAWN BY <br />Daniel M. Ossman <br />SHEET NO. <br />A-8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.