I 11111 II ! It I I I I I I 1 - 1.4t
<br />1 L I 1VVII l .17_.i I - Il 11 S ..11_.. 1 13 1 _ 1J__._ _ t _ .!u --- 11�--�� '-- -- -- I I ---- - --- - I - -- -
<br />Jurisdicl,on Stamp
<br />r— — — — — — — — — — — — — — — —
<br />I
<br />4'-5/8 - 3'-2e 5"
<br />I u
<br />I I
<br />I 115 iV1 I
<br />CL. I
<br />I I
<br />CENTER FLOOR DRAIN
<br />UNDER LAV. TYP.
<br />X
<br />o I w
<br />I
<br />I RESTROOM 1
<br />I e o 2 115
<br />I 104sgft
<br />A413 3
<br />I
<br />I 5 114
<br />I
<br />ALL GENDER
<br />m RESTROOM SIGNAGE, I W1 �/ I Ill — I ci
<br />SEE 1/A003 I 135 sq ft d I N
<br />N 8-3/4'. 11'-101, '� W4 96"'
<br />oo 1 -
<br />�, Y —
<br />o co
<br />w I
<br />w 1131r "ixfM 4x Ox
<br />° I p W1 J I
<br />I Y4 �9 T }Y+N44J 1 j,� 1 w
<br />Iro" �,,�}� �nr ,24 ;j "�°;
<br />a I„. 0 0 2'-1" 41-8„ 2,-6„ cD 1 I
<br />NEW MOP SINK W/ NEW W1 r - LO r
<br />' WATER HEATER ABOVE.
<br />JAN a I
<br />3
<br />° SERV-1��,,,, w C7 z
<br />I W1
<br />113 "
<br />afro a-:` Z w 'd
<br />�. 56 sq ft / \ ®rd ,kb{�{ yt�g ¢ J to (D
<br />SERVER r r " `
<br />0 4P111 16- o ��:�f,, o z
<br />90 sq ft m
<br />w
<br />°
<br />s
<br />�-
<br />T
<br />�-
<br />c6
<br />E
<br />m
<br />L
<br />m
<br />L
<br />ALIGN WALL BUMP -OUTS
<br />W/ EXISTING WINDOWS,
<br />VIF.
<br />a D-
<br />o
<br />E y 1111 203
<br />3 I
<br />o -
<br />$0
<br />� m
<br />M 1 A410 3 o
<br />�N
<br />I
<br />NEW EXTERIOR DOORS
<br />e NEW EXTERIOR DOORS REPLACE INTERIOR WALL 1 POS ® 1 " AND SIDE LITES.
<br />° AND SIDE LITES. -
<br />a ° FINISHES AT EXISTING WALLS r - 00
<br />C 1101 WHERE INDICATED, TYP. U 104 N v
<br />a CIL w N F- 345 sq ft O 1 A412 FIX-2 1031, iv
<br />EXISTING TENANT SPACE NOTES:
<br />00
<br />ALL EXTERIOR GLASS 1. TENANT SPACE WILL NOT BE OCCUPIED DURING
<br />a ALL EXTERIOR CONSTRUCTION. TENANT TO CONFIRM.
<br />Y TO RECEIVE FM-1 GLASS TO
<br />Y N PRIVACY FILM, U.N.O. - RECEIVE FM-1 2. LIFE SAFETY SYSTEMS SHALL REMAIN OPERATIONAL
<br />° PRIVACY FILM, DURING DEMOLITION AND CONSTRUCTION.
<br />- - U.N.O. 3. CONTRACTOR SHALL POST "NO SMOKING" AND "NO OPEN
<br />C L ILL- FLAME" SIGNS FOR THE DURATION OF CONSTRUCTION.
<br />ULI U o CONTRACTOR SHALL PROVIDE AND MAINTAIN CERTIFIED
<br />`" cz7 p J r FIRE EXTINGUISHERS ON SITE FOR THE DURATION OF
<br />y o WORK RM. J M 1— 0 w 1 1 N CONSTRUCTION, APPROVED BY LOCAL AND STATE
<br />.6 w 110 ¢ III — — — — — — — — - Q — — — — — — ca ° JURISDICTION.
<br />359 sq ft a 0 (D in - - o
<br />U C < J J N 1 1 FLOOR PLAN NOTES:
<br />0 0 ¢ ¢
<br />¢ 101 Q
<br />Lo
<br />1. CONTRACTOR AND OWNER TO REVIEW & APPROVE CHALK
<br />y y W3 �vr` LINES OF PARTITION LAYOUT PRIOR TO COMMENCEMENT OF
<br />20'-10 7/8" 1 1 6 0 2 5 1/2 -5 1/2" PARTITION CONSTRUCTION.
<br />Y 0
<br />2. EXTEND ALL STUDS AND WALL MATERIALS TO
<br />N A201 SALES I a sr1 CONSTRUCTION ABOVE, UNLESS OTHERWISE INDICATED.
<br />0 3 103
<br />r_ t0 I 847 S ft I 3. DOOR OPENINGS IN PARTITIONS NOT DIMENSIONED ARE TO
<br />m I A411 1 q I BE LOCATED WITHIN 6" OF ADJACENT PERPENDICULAR
<br />E I I 1 PARTITION, TYPICAL UNLESS OTHERWISE NOTED.
<br />8 I I A200
<br />I 1081 1091 2 I 4. USE WATER RESISTANT GYPSUM BOARD AT ALL AREAS
<br />ow
<br />° I - --- 1 -- - - - I SUBJECT TO MOISTURE AND CEMENT BOARD WHERE TILE IS
<br />-
<br />I I zt TO BE USED.
<br />a I FIX-2 FIX-2 I ci
<br />° o I ��� I 5. ALL MILLWORK SHALL CONFORM TO AWMAC "CUSTOM
<br />I �"Li
<br />3 � \ w I r,l?OnF" to/nnn1A/nPI<IKIr CTANnORnC I Inn FCC nTHFRtA/ICF
<br />C N
<br />NOTED.
<br />L I REPLACE INTERIOR WALL
<br />a I FINISHES AT EXISTING WALLS I 6. FIELD MEASURE AS REQUIRED FOR ALL MILLWORK
<br />a I EX. VAULT WHERE INDICATED, TYP. CONDITIONS PRIOR TO FABRICATION.
<br />° M I 109
<br />3
<br />7. PROVIDE AND INSTALL ALL NECESSARY WALL BACKING,
<br />194 sq ft 5'-8 1/4" 17'-4" 6'-2" I STIFFENERS, BRACING, BACK-UP PLATES AND / OR
<br />$ ---
<br />0 0 I I SUPPORTING BRACKETS AS REQUIRED FOR THE INSTALLATION
<br />I I OF WALL -MOUNTED OR SUSPENDED EQUIPMENT OR BUILT-IN
<br />FIX-1 FIX-1 FIX-1 I ITEMS. VERIFY REQUIREMENTS WITH MANUFACTURERS PRIOR
<br />a ° I eo 00 I TO INSTALLATION. SUPPLY CATALOG CUT SHEETS FOR
<br />E I — I ARCHITECT'S APPROVAL.
<br />0 L I 1031 I
<br />8. PROVIDE AND INSTALL ALL NECESSARY ELECTRICAL
<br />o i 1061 DRIVE THRU 1 LO EX. MECH. 24CONNECTIONS AND PLUMBING SUPPLY, FITTINGS &
<br />" DEEP FIN-8 P-LAM COUNTER
<br />I 108 106 I ON CONCEALED BRACKETS. CONNECTORS TO COMPLETE INSTALLATION OF APPLIANCES &
<br />° I 176 sq ft CONSULT I HEIGHT TO MATCH EXISTING, EQUIPMENT INDICATED ON PLANS. VERIFY REQUIREMENTS
<br />0 olw<
<br />102 sq ft WITH MANUFACTURERS PRIOR TO INSTALLATION. SUPPLY
<br />o I A500 A500 105 w i COUNTER TO INTERFACE WITH CATALOG CUT SHEETS FOR ARCHITECT'S APPROVAL.
<br />- 4 r - - - DRIVE-THRU TRANSACTION
<br />o I I I co 8W 1/2" 5 s , I HARDWARE, GC VERIFY
<br />m I S AIR I STORAGE NEEDS WITH TENANT. 9. CONTRACTOR TO VERIFY LOCATION OF ALL THERMOSTATS
<br />o WITH ARCHITECT AND OR MECHANICAL ENGINEER PRIOR TO
<br />Y M I UP 28" DEEP FIN-8 P-LAM COUNTER ON INSTALLATION.
<br />°' I I 4 S o N I CONCEALED BRACKETS @ 30" AFF.
<br />0 0 I I I 10. UNLESS OTHERWISE NOTED, ALL GYPSUM
<br />o NI I BOARD SURFACES, WALLS, AND CEILINGS SHALL BE TAPED,
<br />° 3 I I SANDED SMOOTH TO A "LEVEL 5" FINISH, SO AS TO RECEIVE
<br />�° I 4'-10" 10" �, �, 13'-10 1/8" 1071 1 "22'-7.1/4" n_ _ - 5" 6'-2" j PAINT OR WALL COVERING MATERIAL.
<br />49'-6 3/8"
<br />C 1 I 11. PROVIDE SOUND INSULATION AT INTERIOR WALLS, TO
<br />aCREATE AN ACOUSTIC ENVELOPE, UNLESS NOTED
<br />L----------— — — — — — — — — ----------� - ------
<br />OTHERWISE.
<br />C ' I NO PRIVACY FILM AT DRIVE THRU WINDOW.
<br />° a
<br />I I 12. ALL DIMENSIONS TO FINISH MATERIALS, UNLESS
<br />� U
<br />Q o I I GC TO ENGAGE BANK EQUIPMENT
<br />OTHERWISE NOTED.
<br />VENDOR TO EVALUATE CONDITION OF
<br />0
<br />EXISTING DRIVE-THRU TRANSACTION I 13. ALL DOOR HANDLES TO BE LOCATED AT 42" AFF UNO.
<br />I I HARDWARE, REFURBISH OR REPLACE
<br />Z m I I �r r'r"� ���r 14. GC TO PROVIDE BACKING AND MOUNTING BRACKETS AS
<br />0 1 FLOOR PLAN: 1 st Floor NEEDED FOR ALL WALL MOUNTED MILLWORK, FIXTURES, &
<br />cc
<br />y A101 SCALE:1/4" = V-0° EQUIPMENT.
<br />0-0
<br />PROJECT
<br />Z�
<br />client
<br />PLANTS OF RUSKIN LLC
<br />JOHN TIPTON
<br />PO BOX 126
<br />RUSKIN, FL 33575
<br />john.tipton@altmed.com
<br />electrical engineer
<br />JEWITT ENGINEERING INC.
<br />623 BAYSIDE DR.
<br />FORT MEYERS, FL 33919
<br />239-432-1550
<br />jjjewitt@comcast.net
<br />mechanical / plumbing engineer
<br />KEVATRON ENGINEERING, INC.
<br />2324 CORAL POINT DRIVE
<br />CAPE CORAL, FL
<br />KEVIN ADAMS
<br />kevatron60@gmaii.com
<br />239-242-7367
<br />drawing releases
<br />02 15 APR. 2022 ISSUED FOR PERMIT
<br />01 13 APR, 2022 ISSUED FOR CLIENT REVIEW
<br />issue date issued for
<br />architect
<br />collective office
<br />ARCHITECTURE
<br />INTERIORS
<br />DESIGN STRATEGY
<br />9 east 24th st., chicago, Illinois 60616
<br />1-312-818-2006 1 www.collectiveoffice.com
<br />I hereby certify that these plans were prepared under my direction
<br />and to the the best of my knowledge conform to the State and Local
<br />Building Codes and Ordinances.
<br />F�Pill
<br />KL* SON •: 0
<br />� • pR101389 .• C:
<br />c�sr�aE� P�G�
<br />Project
<br />MUV ZEPHYRHILLS, FL
<br />Location 5230 6TH ST
<br />ZEPHYR HILLS, FL
<br />Drawing Title
<br />FLOOR PLAN
<br />Drawing No. A 1 O 1
<br />Issued For Job No.
<br />22013.0
<br />Q c
<br />~ n
<br />Vl
<br />J �
<br />Date
<br />Permit 04-15-2022
<br />111
<br />
|