Jurisdi(A1011 Stamp
<br />24" RLAM UPPER CABINET W/
<br />WIRE PULLS OVER FRIDGE.
<br />'i '
<br />PROVIDE HOLE IN BOTTOM
<br />/
<br />cL
<br />FIN�7
<br />OF UPPER TO ALLOW
<br />'
<br />DOOR f
<br />MICROWAVE CABLE TO PASS
<br />N
<br />THROUGH.
<br />L
<br />Qi /
<br />Q�
<br />12" RLAM UPPER CABINETS
<br />ih
<br />M�Rpyv�vE
<br />36"COUNTER ILL
<br />DEPTH F�
<br />\Q
<br />W/ WIRE PULLS.
<br />REFRIDGERATOR
<br />N
<br />W/ICEMAKER
<br />p
<br />CONNECTION.
<br />00
<br />FIN-8 N
<br />FAU-2 > ;T
<br />RLAM COUNTER
<br />24" P.LAM BASE CABINETS W/
<br />WIRE PULLS.
<br />c _
<br />N j
<br />TOE KICK ATTACHED TO
<br />DOORS AT SINK FOR
<br />3'-7/8"2'-0" 3'1'-6 WHEELCHAIR ACCESS.
<br />9'-6 7/8"
<br />�7INTERIOR ELEVATTON: Break Room
<br />SCALE:3/8" = V-0"
<br />v
<br />m
<br />a o�
<br />c
<br />a,o
<br />U
<br />UUU (V
<br />Co L
<br />O L U
<br />� N �
<br />O N
<br />y Y
<br />U
<br />O Q O
<br />y f' 0 a
<br />C N
<br />U a
<br />C N
<br />° a�
<br />C 0 N
<br />'y 3 r
<br />0 N c0
<br />Y a
<br />`w c rG
<br />C. r N
<br />Q) 3 0
<br />— m
<br />0. D
<br />oQ
<br />aD
<br />°c' m
<br />0
<br />ar
<br />o .0)`
<br />0
<br />° o
<br />7 O N
<br />U C `1
<br />O
<br />° N
<br />C N
<br />t ° o
<br />u! N
<br />Y
<br />�M
<br />a u1 L
<br />C U 1p
<br />C N C
<br />E
<br />ro 00 `o
<br />`o M 5
<br />N m 0
<br />am
<br />m o.
<br />M o `
<br />o a 3
<br />c c w
<br />O
<br />O
<br />:3 w L
<br />a �Q
<br />m v 0
<br />� ot_
<br />C � O
<br />m `p c
<br />c 3 •�
<br />•-0
<br />c E2
<br />rn
<br />0 O c
<br />U
<br />a �
<br />u n
<br />m E y
<br />a �L
<br />v
<br />cQ
<br />o m
<br />0
<br />U C
<br />L M N
<br />3 o
<br />m N c
<br />c,
<br />O MCI -do)
<br />E `0 0
<br />0 c�
<br />U . p,
<br />C
<br />M 3
<br />0 0
<br />0 c
<br />�r
<br />��
<br />r UN
<br />0
<br />o U Q
<br />U N
<br />t�
<br />C C`=
<br />Z
<br />C U
<br />N
<br />u Q` 0
<br />a r cc)
<br />F c
<br />o z=
<br />w
<br />�g
<br />8 LL.
<br />o°
<br />H
<br />= Z_
<br />1.
<br />Q c
<br />0 0
<br />U zi 9)
<br />M
<br />6" L L V-0" L_ 2'-0" L T-1 1 /4" 7'-2 3/8" L
<br />'1
<br />13'-9 3/4"
<br />INTERIOR ELEVATION: Restroom 1, West
<br />SCALE:3/8" = V-0"
<br />EX CEILING HEIGHT
<br />UNDER STAIRS TO
<br />REMAIN, NEW GWB,
<br />VERIFY HEIGHTS ON
<br />SITE.
<br />INSTALL GRAB BARS
<br />PER LOCAL ADA
<br />REQUIREMENTS,
<br />PROVIDE BACKING AS
<br />NECESSARY
<br />WALL TILE TO ALIGN W/
<br />WINDOW SILL, TYP
<br />FORWARD
<br />APPROACH ADA
<br />CLEARANCES TO BE
<br />MET UNDER SINK.
<br />INSTALL GRAB BARS
<br />PERLOCALADA
<br />REQUIREMENTS,
<br />PROVIDE BACKING AS
<br />NECESSARY
<br />\ GWB
<br />\ SCHLUTER JOLLY
<br />\ NT- TRIM AT EXPOSED
<br />TILE EDGES, TYP.
<br />\ r'
<br />\< GB-3
<br />1142 \ \
<br />/ TTD-1 b
<br />/ s
<br />/ - O
<br />/ N
<br />/ TOI-1
<br />5'-8 1/4" V-5 3/8" V-3" " 2'-0" 1'-0"
<br />11'-7 5/8"
<br />INTERIOR ELEVATION: Restroom 1, South
<br />SCALE:3/8" = V-0"
<br />4 ENLARGED FLOOR PLAN: Break Room
<br />A413 SCALE:3/8" = V-0" PROJECT
<br />NORTH
<br />I, 4'-2 1/8" I, 5'-6" I, 4'-1 5/8" I,
<br />INTERIOR ELEVATION: Restroom 1, East
<br />SCALE:3/8" = V-0"
<br />-
<br />1 V-7 5/8" ,
<br />INTERIOR ELEVATION: Restroom 1, North
<br />SCALE:3/8" = V-0"
<br />1 ENLARGED FLOOR PLAN: Restrooms
<br />SCALE:3/8" = V-0"
<br />SCHLUTER JOLLY
<br />TRIM AT EXPOSED
<br />TILE EDGES, TYP.
<br />RECESSED PAPER
<br />TOWEL DISPENSER /
<br />TRASH, INSTALL PER
<br />MANUF. SPEC.
<br />PROJECT
<br />NORTH
<br />INTERIOR ELEVATION NOTES:
<br />1. GENERAL CONTRACTOR TO VERIFY ALL APPLIANCE /
<br />MILLWORK COORDINATION.
<br />2. CONTRACTOR AND ARCHITECT TO REVIEW & APPROVE
<br />CHALK LINES OF PARTITION LAYOUT PRIOR TO
<br />COMMENCEMENT OF PARTITION CONSTRUCTION.
<br />3. EXTEND ALL STUDS AND WALL MATERIALS TO
<br />CONSTRUCTION ABOVE, UNLESS OTHERWISE INDICATED.
<br />4. DOOR OPENINGS IN PARTITIONS NOT DIMENSIONED ARE TO
<br />BE LOCATED WITHIN 4" OF ADJACENT PERPENDICULAR
<br />PARTITION, TYPICAL.
<br />5. ALL MILLWORK SHALL CONFORM TO AWMAC "CUSTOM
<br />GRADE" WOODWORKING STANDARDS UNLESS OTHERWISE
<br />NOTED.
<br />6. FIELD MEASURE AS REQUIRED FOR ALL MILLWORK
<br />CONDITIONS PRIOR TO FABRICATION.
<br />7. PROVIDE AND INSTALL ALL NECESSARY WALL BACKING,
<br />STIFFENERS, BRACING, BACK-UP PLATES AND / OR
<br />SUPPORTING BRACKETS AS REQUIRED FOR THE INSTALLATION
<br />OF WALL -MOUNTED OR SUSPENDED EQUIPMENT OR BUILT-IN
<br />ITEMS. VERIFY REQUIREMENTS WITH MANUFACTURERS PRIOR
<br />TO INSTALLATION. SUPPLY CATALOG CUT SHEETS FOR
<br />ARCHITECT'S APPROVAL.
<br />8. PROVIDE AND INSTALL ALL NECESSARY ELECTRICAL
<br />CONNECTIONS AND PLUMBING SUPPLY, FITTINGS &
<br />CONNECTORS TO COMPLETE INSTALLATION OF APPLIANCES &
<br />EQUIPMENT INDICATED ON PLAN. VERIFY REQUIREMENTS
<br />WITH MANUFACTURERS PRIOR TO INSTALLATION. SUPPLY
<br />CATALOG CUT SHEETS FOR ARCHITECT'S APPROVAL.
<br />9. PREPARE ALL FLOOR SURFACES AS REQUIRED TO
<br />RECEIVED FINISHES AS NOTED ON FINISH PLAN, ENLARGED
<br />FINISH PLANS & FINISH LEGEND.
<br />10. UNLESS OTHERWISE NOTED, ALL GYPSUM BOARD
<br />SURFACES, WALLS, AND CEILINGS SHALL BE TAPED, SANDED
<br />SMOOTH TO A "LEVEL 4" FINISH, SO AS TO RECEIVE PAINT OR
<br />WALL COVERING MATERIAL,
<br />11. FINAL LOCATION OF COAT HOOKS, GRAB BARS, TOILET
<br />PAPER HOLDERS, AND TOILET CONTROLS TO BE
<br />COORDINATED AND APPROVED BY ARCHITECT.
<br />12. GC TO PROVIDE BACKING AND MOUNTING BRACKETS AS
<br />NEEDED FOR ALL WALL MOUNTED MILLWORK, FIXTURES, &
<br />EQUIPMENT.
<br />client
<br />PLANTS OF RUSKIN LLC
<br />JOHN TIPTON
<br />PO BOX 126
<br />RUSKIN, FL 33575
<br />john.tipton@altmed.com
<br />electrical engineer
<br />JEWITT ENGINEERING INC.
<br />623 BAYSIDE DR.
<br />FORT MEYERS, FL 33919
<br />239-432-1550
<br />jjjewitt@comcast.net
<br />mechanical / plumbing engineer
<br />KEVATRON ENGINEERING, INC.
<br />2324 CORAL POINT DRIVE
<br />CAPE CORAL, FL
<br />KEVIN ADAMS
<br />kevatron60@gmail.com
<br />239-242-7367
<br />drawing releases
<br />02 15 APR, 2022 SSUED FOR PERMIT
<br />01 13 APR, 2022 ISSUED FOR CLIENT REVIEW
<br />issue date issued for
<br />architect
<br />collectiveoffice
<br />ARCHITECTURE
<br />INTERIORS
<br />DESIGN STRATEGY
<br />9 east 24th st., chicago, illinois 60616
<br />1-312-818-2006 1 www.collectiveoffice.com
<br />I hereby certify that these plans were prepared under my direction
<br />and to the the best of my knowledge conform to the State and Local
<br />Building Codes and Ordinances.
<br />of FLO
<br />Co: F KLYMS0/y
<br />AR10 89
<br />�E6D
<br />Project
<br />MUV LZEPHYRHILLS, FL
<br />Location 5230 6TH ST
<br />ZEPHYR HILLS, FL
<br />Drawing Title
<br />INTERIOR ELEVATIONS
<br />Drawing No. A413
<br />Issued For Job No.
<br />22013.0
<br />Date
<br />Permit 04-15-2022
<br />
|