My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5338 8th St
Zephyrhills
>
Building Department
>
Building Plans
>
5338 8th St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 9:46:20 AM
Creation date
2/18/2025 3:21:14 PM
Metadata
Fields
Template:
Building Plans
Street #
5338
Location
8th St
Contractor
Crenshaw Consullting Engineers
Building Plans - Permit #
8669
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
o <br />N <br />V <br />ELECTRICAL LEGEND <br />�� <br />260101 BASIC ELECTRICAL REQUIREMENTS <br />' cq n ^m <br />2Voa <br />PL M <br />A- <br />WORKMANSHIP SHALL CONFORM TO NECA INSTALLATION STANDARDS INCLUDING NECA 1. <br />0—v L_ <br />s m o <br />ZEPHYRHILLS CITY HALL <br />5335 8th <br />Street <br />snlleoLssrlowN[;ETowAr:ETOIwDIcnTFNEwDEV OR <br />A <br />INDICATES A DEVICE IS To BE <br />MOUNTED WITH BOTTOM OF BOX <br />B. <br />INSTALLATION SHALL COMPLY WITH NATIONAL ELECTRICAL CODE (NFPA 70), STATE BUILDING CODE, <br />AND ALL REQUIREMENTS OF THE LOCAL INSPECTOR FURNISH INSPECTION CERTIFICATE) WORK <br />(E <br />- nm�� <br />- o o FZ <br />NEwLocarroNsoFExlsnwcDEVICEs sEEUNETVPFLECEN <br />FOR DISTINCTION OF EXISTING DEVICES TO REMIUN AND <br />1 1/2" ABOVE BACKSPLASH UNLESS <br />NOTED OTHERWISE_ <br />-ALL <br />SHALL BE BY LICENSED ELECTRICAL CONTRACTOR. <br />• 4 _ m <br />; a <br />o <br />Zephyrhills, <br />FL 33542 <br />DEMOLITION DEVICES <br />AFF <br />ABOVE FINISHED FLOOR <br />C_ <br />D. <br />CONTACTOR SHALL OBTAIN AND PAY FOR ALL ELECTRICAL PERMITS AND INSPECTION FEES <br />ALL MATERIALS AND EQUIPMENT SHALL BE UL LISTED. <br />A v T <br />HOME RUN TO PANEL / BRANCH CIRCUIT <br />�` <br />AG <br />COMBINATION OF 'A' AND'G' <br />E. <br />AS USED ON THESE DOCUMENTS, THE WORD "PROVIDE" SHALL MEAN TO FURNISH AND INSTALL THE <br />CONNECTION. SHORT CROSS LINES <br />ITEM OR EQUIPMENT AND MAKE THE FINAL CONNECTION AS REQUIRED. <br />= a <br />PROJECT I D. P-002373 <br />�--� REPRESENT PHASE CONDUCTORS, LONG <br />CROSS LINES REPRESENT GROUNDED <br />ARCH <br />ARCHITECT <br />F_ <br />PROVIDE GROUNDING CONDUCTOR FOR ALL CIRCUITS PER N.E C. AND BUILDING GROUND SHALL MEET <br />ALL REQUIREMENTS OF NEC 250. <br />um - E <br />z Ul <br />CONDUCTORS, EQUIPMENT GROUND <br />C <br />INDICATES A DEVICE IS TO BE FLUSH <br />G. <br />THE CONTRACTOO SHALL BRING ALL CONFLICTS BETWEEN THE PLANS AND SPECIFICATIONS TO THE <br />r <br />W/O NUMBER- 53118973 <br />REQUIRED BUT NOT SHOWN. MINIMUM <br />MOUNTED IN CEILING TILE. <br />ATTENTION OF THE ENGINEER FOR RESOLUTION PRIOR TO COMPLETION OF THE WORK <br />�) <br />SIZE PER NEC REQUIREMENTS BASED ON <br />EC <br />ELECTRICAL CONTRACTOR <br />H. <br />COORIDATE LOCATION AND REQUIREMENTS FOR ELECTRICAL SERVICE WITH THE POWER COMPANY. <br />-� <br />CIRCUIT BREAKER / SCHEDULE /VOLTAGE <br />I. <br />ALL CIRCUITS SHALL MEGOHMMETER TESTED (NON-DESTRUCTIVE) PRIOR TO ENERGIZING. <br />DROP TABLE. <br />Ex. <br />EXISTING <br />J. <br />CONTRACTOR IS RESPONSIBLE TO COMPLY WITH ALL REQUIREMENTS OF THE 2018 SOUTH CAROLINA <br />BUILDING CODE, ACCESSIBILITY CODE WHICH ARE APPLICABLE TO THIS PROJECT REGARDLESS OF <br />r $ au DUr'rFXANDaUADRECEPTAC Ess�wuBENFMA520RUNLcsSNaTMOTiERW EXT. EXTERIOR WHETHER ALL DETAILS ARE INDICATED ON PLANS. <br />�r <br />PROJECT <br />CONTACT LIST : <br />DUPLEX RECEPTACLE <br />FA <br />FIE ALARM <br />R <br />260519 LOW -VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLE <br />{ <br />DISCONNECT SWITCH - FUSIBLE <br />FAN <br />FAHRENHEIT <br />SITE HOST: <br />WILLIAM POE JR. CITY MANAGER <br />A. <br />ALL WIRE AND CONDUIT SIZES ARE BASED ON 75" C THHN/THWN COPPER CONDUCTORS UNLESS <br />ELECTRICAL TRANSFORMER <br />FURN <br />FURNITURE <br />OTHERWISE NOTED. ALL CONDUCTORS, TERMINATIONS & DEVICES SHALL BE RATED FOR MINIMUM <br />�Illllti <br />W Oe CI.Ze h rhills.fl.us <br />p @ p y <br />75°C. ALL CONDUCTOR AND CONDUIT SIZES ARE CALCULATED BASED ON INSTALLATION OF NO MORE <br />����G-. ....����i, <br />ELECTRICAL PANEL <br />G <br />INDICATES A DEVICE WITH INTEGRAL <br />THAN 3 CURRENT CARRYING CONDUCTORS PER CONDUIT, NEUTRAL(S) INCLUDED. UNLESS <br />GROUND FAULT INTERRUPTER (CFI) <br />PROTECTION <br />OTHERWISE NOTED, CONTRACTOR SHALL NOT INSTALL MORE THAN 3 CURRENT CARRYING <br />CONDUCTORS PER CONDUIT WITH THE FOLLOWING EXCEPTION: UP TO 9 CURRENT CARRYING <br />�' N :�- <br />GFI <br />SAME AS'G' <br />CONDUCTORS MAY BE USED IN A SINGLE RACEWAY WHERE PERMITTED BY THE NEC WHEN MINIMUM <br />* a o <br />DUKE ENGINEER- <br />DARRYL FOSHEE <br />L/VETYPES <br />#12 AWG (THHN 90-C) IS USED AND WHEN ALL INCLUDED CIRCUITS ARE PROTECTED UPSTREAM BY 20 <br />=� z <br />dar I.foshee duke-ener com <br />ry @ gy <br />HG <br />HOSPITAL GRADE <br />AMP OVERCURRENT DEVICES AND NO OTHER DERATING CONDITIONS EXIST. <br />`\ <br />------ NEW UNDERGROUND OR UNDERSLAB <br />IG <br />DEVICE SHALL HAVE ISOLATED <br />B- <br />C <br />ALL CONDUCTORS SHALL BE U.L.LISTED. <br />ALL CONDUCTORS SHALL BE COPPER RATED 75 DEG. WET/DRY. <br />CONNECTION. EXISTING AND DEMO <br />GROUND AND WILL REQUIRE <br />ISOLATED GROUND CIRCUITRY <br />D <br />ALL CONDUCTORS SHALL BE COPPER TYPE THHN, OR XHHW, SOLID FOR #10 AWG OR #12 AWG, AND <br />UNDERGROUND IS NOTED WITH <br />STRANDED FOR ALL LARGER SIZES. MINIMUM CONDUCTOR SIZE SHALL BE #12. <br />DUKE PROJECT <br />DANIEL ALGOR <br />EXISTING OR DEMO LINETYPE. NEW <br />J B <br />JUNCTION BOX <br />E <br />INSULATION SHALL BE DUAL RATED TYPE THHN/THWN-2 FOR FEEDERS AND BRANC CIRCUITS. <br />.....arw. <br />� F <br />MANAGER: <br />daniel.algor@duke-energy.com <br />CONNECTIONS NOT SPECIFICALLY <br />SHOWN WITH UNDERGROUND <br />MC <br />MC REFERENCING <br />F. <br />G. <br />ALL CONDUCTORS SHALL BE IN CONDUIT. <br />ALL WIRING LUGS SHALL BE RATED FOR USE WITH 75 DEGREE INSULATED CONDUCTORS AT THEIR 75 <br />DANIFL SPRADLING vwu.k <br />ta- awn w i"-n Dour <br />LINETYPE ARE NOT NECESSARILY <br />NEC <br />ICABLE NGMEWH D <br />WIRING METHODS OR TYPE) <br />DEGREE AMPACITY AND SHALL BE SIZED AND SELECTED TO MATCH THE CONDUCTOR SIZE AND <br />6� <br />REQUIRED TO BE RUN OVERHEAD <br />Mc <br />MECHANICAL CONTRACTOR (WHEN <br />MATERIAL. <br />UNLESS NOTED AS SUCH. <br />NOT REFERENCING NEC WIRING <br />H. <br />ALL CIRCUITS SHALL MEGOHMMETER TESTED (NON-DESTRUCTIVE) PRIOR TO ENERGIZING. <br />UPA- <br />ROBERTO CRUZ <br />METHODS OR TYPE.) <br />I. <br />GROUND EQUIPMENT PER NEC 250. <br />rcruz@utilitypartners.com <br />MECLI <br />MECHANICAL CONTRACTOR <br />260534 CONDUITS <br />(864) 498-2425 <br />NTS <br />NOT TO SCALE <br />A- <br />ALL BRANCH CIRCUITS SHALL BE IN 3/4" MINIMUM ZINC -COATED EMT, IMC, OR RMC AS PERMITTED OR <br />OC <br />ON CENTER <br />REQUIRED BY THE NATIONAL ELECTRICAL CODE. LFMC (OR FMC AS PERMITTED) SHALL BE USED FOR <br />FINAL CONNECTIONS TO EQUIPMENT SUBJECT TO VIBRATION. <br />r <br />CRENSHAW <br />JIM SLICE <br />PC <br />PLUMBING CONTRACTOR <br />B. <br />SCHEDULE 40 PVC CONDUIT MAY BE USED FOR UNDERGROUND FEEDERS AND BRANCH CIRCUITS OR <br />_ <br />y <br />UNDERGROUND LOW VOLTAGE SYSTEM CONDUITS LOCATED BELOW THE FLOOR SLAB ON GRADE OR <br />` <br />CONSULTING <br />(864) 275-5343 <br />PLUMB <br />PLUMBING CONTRACTOR <br />BURIED ON THE EXTERIOR OF THE BUILDING, OR IN CONCRETE BLOCK WALLS. <br />ENGINEERS: <br />jim.slice@crenshawconsulting.com <br />PROV <br />PROVIDED BY <br />C. <br />PVC SCHEDULE 80 CONDUIT MAY BE USED ON THE BUILDING EXTERIOR WHERE PERMITTED. <br />CONTRACTOR SHALL INCLUDE COST OF PAINTING ALL EXPOSED CONDUITS IN FINISHED AREAS <br />S <br />INDICATES DEVICE IS TO BE <br />SUBJECT TO PUBLIC VIEW. <br />SURFACE MOUNTED. <br />D. <br />CONDUIT SIZES NOTED ON THESE PLANS ARE BASED ON EMT CONDUIT. WHERE OTHER PERMITTED <br />RACEWAY TYPES ARE USED, CONTRACTOR SHALL ADJUST CONDUIT SIZES AS NECESSARY BASED ON <br />I <br />TAMPER RESISTANT DEVICE. DEVICE <br />SHALL BE APPROVED FOR USE IN <br />RACEWAY TYPE TO BE USED AND ALLOWABLE FILL. PROVIDE PULL WIRE IN ALL EMPTY CONDUIT. <br />AREA SHOWN (CHILD CARE ETC.) <br />JUNCTION BOX COVERS SHALL_ BE PERMANENTLY LABELED AND CONDUIT SHALL BE LABELED EVERY <br />10'. <br />INDICATES COMBINATION USB <br />E. <br />ALL EXTERIOR BOXES SHALL BE NEMA 3R. <br />DUPLEX RECEPTACLE <br />260553 <br />IDENTIFICATION FOR ELECTRICAL SYSTEMS <br />W/ <br />WITH <br />WP <br />INDICATES A DEVICE THAT RATED <br />A. <br />PROVIDE UV RESISTAN WEATHERPROOF PLASTIC ADHESIVE LABELS FOR ALL ELECTRICAL EQUIPMENT <br />s <br />FOR EXTERIOR TEMPERATURES AND <br />SUPPLIED FOR THE PROJECT, INCLUDING WIRING, SAFEY SWITCHES, PANELBAORDS, ETC. NAMEPLATE <br />IS WEATHERPROOF OR WEATHER <br />SHALL INDICATE THE DEVICE NAME, SYSTEM VOLTAGE AND UPSTREAM DEVICE AND CIRCUIT. <br />Y, <br />RESISTANT WITH AN APPROVED <br />(IN -USE) WEATHERPROOF COVER <br />262413 AND 262416 SWITCHBOARDS AND PANELBOARDS <br />J N <br />J �- <br />w <br />Q <br />w <br />DRAWING <br />INDEX <br />A. <br />WI <br />ALL PANELS AND SWITCHBOARDS / STCHGEAR SHALL BE COMMERCIAL GRADE FROM A REPUTABLE <br />NATIONAL MANUFACTURER SUCH AS SQUARE'D', G.E., SIEMENS AND EATON. <br />M <br />w # <br />SHEET NUMBER <br />SHEET DESCRIPTION ISSUE DATE <br />B. <br />PANELS SHALL BE RATED AS INDICATED ON PANEL SCHEDULES. <br />(LJ <br />r . <br />C. <br />BUS AMPACITY SHALL BE FULLY RATED TO THE VALUE INDICATED FOR THE BUS, LUGS OR MAIN <br />J <br />(� <br />"° I* <br />BREAKER INDICATED FOR THE PANEL I BUS. WHERE SELECTIVE OVERCURRENT COORDINATION IS <br />REQUIRED BY THE APPLICABLE CODES THE GEAR SUPPLIER SHALL INCLUDE ALL NECESSARY <br />( > <br />F--•I <br />U <br />r .. <br />0 E001 COVER SHEET 23SEPT2024 <br />EQUIPMENT AND DEVICES (INCLUDING ANY SUPPLEMENTARY EQUIPMENT NOT SHOWN ON THE PLANS) <br />�+ <br />! �A <br />0 E101 RISER DIAGRAM & PANEL SCHEDULES 23SEPT2024 <br />WITH ALL NECESSARY OPTIONS, FEATURES AND SETTINGS TO ACHIEVE THE REQUIRED <br />U E201 SITE <br />POWER PLAN 23SEPT2024 <br />COORDINATION UNDER THE BASE BID. <br />J —� <br />D. <br />PROVIDE SERVICE ENTRANCE LABEL FOR SERVICE PANELBOARDS. <br />00 <br />0 E202 DEMOLITION <br />PLAN 23SEPT2024 <br />E. <br />PROVIDE A TYPED CIRCUIT DIRECTORY FOR EACH PANEL BOARD PER NEC 408.4. <br />0 E301 EQUIPMENT DETAILS 23SEPT2024 <br />F. <br />ALL MULTIWIRE BRANCH CIRCUITS SHALL HAVE MULTIPOLE BREAKERS AS REQUIRED BY NEC 210.7. <br />Ln <br />M i- <br />� <br />0 E401 DETAILS 23SEPT2024 <br />GENERAL REQUIREMENTS <br />Ln <br />uj LLJ <br />ELECTRICAL <br />COORDINATION WITH OTHER TRADES AND EQUIPMENT PROVIDE BY OTHERS: <br />N <br />A <br />THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NECESSARY DISCONNECTS, SWITCHES, AND <br />RECEPTACLES UNDER THE ELECTRICAL BID AND SHALL INCLUDE ALL NECESSARY CIRCUITS TO AND <br />FINAL CONNECTIONS TO THE EQUIPMENT PROVIDED BY ALL SUPPLIERS, UNLESS NOTED OTHERWISE <br />BY OTHER DISCIPLINES. COORDINATE CLOSELY. <br />B. <br />E C. SHALL PROVIDE ROUGH -INS FOR ALL E.C. PROVIDED EQUIPMENT (INCLUDING SUB -CONTRACTED <br />EQUIPMENT AS APPLICABLE) AND DEVICES LOCATED ON THESE PLANS IN ACCORDANCE WITH NEC, <br />NFPA, AND MANUFACTURER REQUIREMENTS. UNLESS OTHERWISE NOTED, BOX PROVIDED SHALL BE <br />SUITABLE FOR AND SIZED FOR THE PURPOSE, WITH A MINIMUM 3/4" CONDUIT TO ACCESSIBLE <br />LOCATION ABOVE CEILING OR CONDUIT SIZED AS APPROPRIATE FOR THE DEVICE IN QUESTION <br />C. <br />ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED SO THAT ALL CODE -REQUIRED AND <br />MANUFACTURER -RECOMMENDED SERVICING CLEARANCES ARE MAINTAINED. INSTALLATIONS SHALL <br />FULLY COMPLY WITH NEC 110.26 AND NEC 408.18 FOR CLEARANCE REQUIREMENTS. <br />SITE CONDITIONS <br />A. <br />THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY DISPOSING OF ALL WASTE MATERIALS, DEMO <br />MATERIALS AND OTHER TRASH. THIS INCLUDES BUT IS NOT LIMITED TO PROPER DISPOSAL OF <br />MERCURY CONTAINING LAMPS, RECYCLABLE MATERIALS ETC. <br />CODES AND STANDARDS <br />• <br />FLORIDA BUILDING CODE (FBC) - 2023 <br />• <br />NATIONAL ELECTRICAL CODE (NEC) / NFPA 70 - 2020 <br />REVISIONS: <br />NO. <br />DATE <br />I DESCRIPTION <br />DATE: <br />SEPTEMBER 23, 2024 <br />CONTENTS <br />ELECTRICAL <br />COVER SHEET <br />SHEET <br />E=001 <br />I <br />