Laserfiche WebLink
GENERAL NOTES: <br />THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2011 FLORIDA BUILDING CODE <br />6TH EDITION AND THE 2011 FLORIDA BUILDING CODE - RESIDENTIAL 6TH EDITION. <br />T.L. HANSON A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL ENGINEERING <br />COMPANY: HAS APPLIED "RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN OF THIS STRUCTURE. <br />THE BUILDING (INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE <br />FOLLOWING SUPERIMPOSED LOADS: <br />SLAB: <br />LIVE LOAD - 50 P.S.F. <br />DEAD LOAD - 10 P.S.F. <br />ROOF: <br />LIVE LOAD (TRUSS TOP CHORD) - 20 P.S.F. <br />DEAD LOAD (TRUSS TOP CHORD) - 10 P.S.F. (15 P.S.F. WHEN TILE ROOFING IS INSTALLED) <br />DEAD LOAD (TRUSS BOTTOM CHORD) - 10 P.S.F. <br />ASSUMED TRUSS SELF WEIGHT (DEAD LOAD) - 1 P.S.F. <br />WIND: <br />BUILDING IS DESIGNED TO CONFORM TO ASCE 1-10, CHAPTERS 26 THRU 31. PER 2011 FLORIDA <br />BUILDING CODE, RESIDENTIAL 6TH EDITION- SECTION R301.2.1.1. AND 2011 FLORIDA BUILDING CODE <br />6TH EDITION SECTION 160E <br />COMPONENT t CLADDING WIND LOADS <br />WIND DESIGN ASSUMPTIONS: ALL OTHER <br />BUILDING EXPOSURE - B BUILDING ROOF OVERHANG COMPONENT <br />BUILDING RISK CATEGORY - II ZONE LOADS LOADS <br />MEAN ROOF HEIGHT 30' OR LESS <br />HEIGHT 4 EXPOSURE ADJUSTMENT I N/A +32.3/-35.3 <br />COEFFICIENT - 1.0 <br />ENCLOSED BUILDING <br />INTERNAL PRESSURE COEFFICIENT . +/- 0,18 2 -65.1 +32.3/-56.2 <br />WIND SPEED SHOWN AT THE BOTTOM RIGHT 3 <br />CORNER OF THIS SHEET -I10.6 +32,3/-89.0 <br />ALL STRUCTURAL ELEMENTS, EXTERIOR 4 N/A +35.3/-38.2 <br />WALLS AND INTERIOR WALLS SHALL BE <br />TYPE V CONSTRUCTION PER FBC 602.5 5 N/A +35.3/41,2 <br />SOIL BEARING 4 COMPACTION: <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 P.S.F. <br />(MINIMUM). THE CONTRACTOR/PROPERTY OWNER ARE RESPONSIBLE FOR VERIFYING THAT THE SOIL <br />ON THE SITE IS PROPERLY PREPARED 4 COMPACTED SUCH THAT IT CAN SUPPORT A 2,000 P.S.F. <br />FOUNDATION LOADING. <br />T.L. HANSON; A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL <br />ENGINEERING COMPANY: DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION SITE <br />NOR PERFORMING ANY SOIL TESTING. <br />T.L. HANSON SHALL NOT BE RESPONISIBLE FOR THE SITE SOILS ABILITY TO SUPPORT <br />THE BUILDING LOADS. <br />FOUNDATIONS 4 SLAB -ON -GRADE: <br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS WITHIN THE BUILDING AREA. <br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED <br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2,000 P.S.F. FOUNDATION LOADING. <br />SLAB SHALL BE PLACED OVER A 6 MIL VAPOR BARRIER ON CLEAN, ADEQUATELY <br />COMPACTED AND TERMITE POISONED SOIL, <br />CONCRETE UTILIZED IN THE FOUNDATIONS AND SLABS SHALL HAVE A MINIMUM 28 DAY <br />COMPRESSIVE STRENGTH OF 2,500 P.S.I. <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" <br />FOR 05 REBAR, 30" FOR •6 REBAR 4 35" FOR 01 REBAR. <br />PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES (AFTER <br />FINAL SITE GRADING). THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE <br />EXACT STEMWALL HEIGHT BASED UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION <br />AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSES ARE REQUIRED. <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE <br />SITE FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND <br />A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY THE REQUIRED BUILDING SETBACKS. <br />MASONRY WALLS: <br />CONCRETE MASONRY UNITS SHALL BE HOLLOW UNIT MASONRY IN ACCORDANCE WITH ASTM C-90 <br />AND SHALL HAVE A MINIMUM F'M OF 1,500 P.S.I. <br />MORTAR SHALL CONFORM TO ASTM C-210 AND SHALL BE EITHER TYPE M OR S. <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" <br />FOR •5 REBAR, 30" FOR 06 REBAR 4 35" FOR •1 REBAR. <br />GROUT FOR THE POURED CELLS AND LINTELS SHALL HAVE A MAXIMUM COURSE AGGREGATE SIZE <br />OF 3/8", PLACED AT AN 8 TO II INCH SLUMP AND HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH <br />OF 2,500 P.S.I. (WHEN TESTED PER ASTM C-1019). <br />PROVIDE CLEAN -OUT OPENINGS (12 SO, IN.) IN CELLS CONTAINING SPLICED REINFORCEMENT, WHEN <br />THE GROUT POUR EXCEEDS 5 FEET IN HEIGHT. <br />TIMBER MATERIALS: <br />ALL TIMBER MATERIALS SHALL BE AS FOLLOWS: <br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH -INS MUST BE COMPLETE, INSPECTED AND APPROVED <br />PRIOR TO REQUESTING THE FRAMING INSPECTION. <br />IF DESIRED, EQUIVALENT CONNECTORS MADE BY ANOTHER SUPPLIER MAY BE USED IN PLACE OF THE <br />"USP" OR "SIMPSON" CONNECTORS SHOWN. <br />ALL LUMBER IN CONTACT WITH MASONRY WILL BE PRESSURE TREATED <br />MATERIALS <br />INTERIOR STUD WALLS TO BE OF 2 X 4 02 SPRUCE OR BETTER WITH SINGLE 2 X 4 P.T. <br />PINE BOTTOM PLATE AND SINGLE 2 X 4 02 SPRUCE TOP PLATE WITH STUDS SPACED <br />MAXIMUM 24" OC. WALLS TO HAVE 1/2" GYPSUM BOARD EACH SIDE, WITH WALLS AT <br />GARAGE TO HAVE MINIMUM R-11 INSULATION <br />ATTIC ACCESS: <br />ATTIC ACCESS SHALL BE PROVIDED TO ATTIC AREAS EXCEEDING 30 SQ. FT, AND HAVING MINIMUM <br />30 INCHES OF VERTICAL HEIGHT, ROUGH -FRAMED OPENING NOT TO BE LESS THAN 22 X 30 INCHES. <br />WHEN MECHANICAL EQUIPMENT IS LOCATED IN THE ATTIC, IT SHALL BE INSTALLED IN ACCORDANCE <br />WITH THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION M1305.1.3 <br />TRUSSES: <br />IF THE CONTRACTOR, TRUSS MANUFACTURER OR ANY OTHER DESIGN PROFESSIONALS REVISE THE <br />TRUSS SYSTEM LAYOUT FROM THOSE SHOWN ON THESE PLANS T. L. HANSON 4 ASSOCIATES IS <br />REQUIRED TO REVIEW ALL FINAL CONSTRUCTION DOCUMENTS FOR COMPLIANCE WITH THE DESIGN <br />INTENT PRIOR TO COMMENCEMENT OF THE PROJECT, <br />EXTERIOR WINDOWS 4 DOOR ASSEMBLIES: <br />ALL EXTERIOR WINDOW 4 GLASS DOORS SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA <br />101/162 STANDARDS AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, <br />PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY. <br />ALL MULLIONS AND ADJACENT DOOR/WINDOW ASSEMBLIES SHALL BE TESTED OR ENGINEERED TO <br />TRANSFER 1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE. <br />INSTALL ALL WINDOW 4 DOOR ASSEMBLIES PER THE MANUFACTURERS ANCHORING RECOMMENDATIONS <br />TO ACHEIVE THE DESIGN PRESSURES SPECIFIED. <br />ELECTRICAL, PLUMBING 4 MECHANICAL: <br />IN ACCORDANCE WITH CHAPTER 411.003(2XI) OF THE FLORIDA ADMINISTRATIVE CODE: ELECTRICAL, <br />PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTORS TO <br />MEET ALL APPLICABLE CODES. THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HEREON <br />ARE BASED UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS. <br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, GARAGE AND AT <br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND -FAULT INTERRUPTER "GFI" CIRCUIT. <br />ALL ELECTRICAL OUTLETS IN HABITABLE SPACES SHALL BE WIRED INTO AN ARC -FAULT INTERRUPTER <br />SAFETY GLAZING: <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF <br />GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308: <br />(1) GLAZING IN SWINGING DOORS, FIXED AND SLIDING PANELS OF SLIDING DOOR <br />ASSEMBLIES. <br />(2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM <br />ROOMS, BATHTUBS, AND SHOWERS, GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS <br />THAN 60 INCHES ABOVE THE DRAIN INLET. <br />(3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE <br />THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR IN A <br />CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE <br />FINISHED FLOOR OR WALKING SURFACE. <br />(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS <br />DESCRIBED IN ITEMS (2) AND (3) ABOVE. THAT MEETS ALL OF THE FOLLOWING <br />CONDITIONS: <br />A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SO. FT. <br />B) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. <br />C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. <br />D) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE <br />PLANE OF THE GLAZING. <br />REFER TO THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308 FOR ADDITIONAL AREAS <br />TWAT MAY BE CONSIDERED A HAZARDOUS LOCATION FOR THE PURPOSE OF GLAZING. <br />DRAFTSTOPPING: <br />IN SINGLE FAMILY DWELLINGS, DRAFTSTOPPING SHALL BE PROVIDED (PARALLEL TO THE MAIN <br />FRAMIMG MEMBERS) IN FLOOR/CEILING ASSEMBLIES SEPARATING USEABLE SPACES. DRAFTSTOPPING <br />SHALL BE CONSTUCTED SUCH THAT THE FLOOR/CEILING ASSEMBLY IS BROKEN UP INTO TWO OR <br />MORE APPROXIMATE AREAS WITH NO AREA GREATER THAN 1000 SO, FT. <br />APPROVED PRODUCT LIST <br />PRODUCT CATEGORY SUB CATEGORY MANUFACTURER <br />STRUCTURAL COMPONENT <br />STRUCTURAL COMPONENT <br />ROOFING <br />ROOFING <br />WINDOWS <br />SOFFIT 4 FASCIA TRIM <br />HIO <br />HETA20 <br />ASPHALT <br />UNDERLAYMENT <br />SIMPSON <br />SIMPSON <br />GAF SINGLES ALL <br />GAF <br />EXISTING WOOD WINDOWS APPROVED BY <br />CITY OF ZEPHYRHILLS DUE TO HISTORIC HOME <br />SOFFIT WOOD TO MATCH EXISTING <br />DUE TO HISTORIC HOME <br />EXTERIOR DOORS SINGLE SWINGING PLAET PRO <br />WALL SIDING EXTERIOR WOOD TO MATCH EXISTING <br />DUE TO HISTORIC HOME <br />THE CLIENT UNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE <br />AGREES TO HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOSSES AND <br />EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT OF OR RESULTING FROM THE <br />PROJECT. THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION <br />DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR COST OF <br />REPAIRS OR DELAY TO THE CONSTRUCTION <br />STATE OF FL, <br />APPROVAL M <br />FL 10446 <br />FL 114-13 <br />FL 10124.1 <br />FL 10626.1 <br />N/A <br />N/A <br />FL 15221.1 <br />N/A <br />I <br />::r 5i1 I <br />/llr till <br />1 1 r�r A z all 1 <br />I <br />E/XIST/ING/HOU/SE', -- - -� <br />r Z Z Z Z 1111.� <br />CONTRACTOR OR OWNER TO VERIFY ROOF PITCH <br />AND HEEL HEIGHT ON EXISTING HOUSE TO MATCH <br />RIDGE VENT <br />_ _ WALL HEIGHT S 9' 1" <br />_ - _ _FINISH FLOOR V <br />APPROXIMATE GRADE O' O" <br />PINE NOVELTY SIDING / <br />TO MATCH EXISTING <br />PROPOSED SOUTH ELEVATION 1/411 = If O'I <br />PROPOSED EAST ELEVATION 1/4" = 11 O" <br />RIDGE VENT <br />\ PINE NOVELTY SIDING <br />TO MATCH EXISTING <br />PROPOSED NORTH ELEVATION 1/4" = 1 � O'I <br />m <br />N <br />in <br />Z <br />M <br />z <br />o <br />� <br />O <br />Iw4 <br />0 <br />;L F <br />Lnz <br />' <br />0 N <br />ill <br />Z <br />V <br />N <br />w <br />Z <br />u- <br />�o <br />NJ <br />Ly111 <br />z <br />r <br />m <br />Q <br />ill <br />U <br />z <br />Z <br />Nd) <br />Ww <br />UM m <br />m� a <br />s`` <br />to <br />cn <br />Zz <br />5;, Z <br />Z <br />Lu <br />Z� <br />` <br />-.6.4 <br />Q <br />O <br />zz <br />L <br />i <br />5 <br />H <br />Q <br />ZZ <br />lz� <br />� <br />O llJ <br />N <br />� N <br />Ln <br />m <br />CONTRACTOR OR OWNER TO VERIFY ROOF PITCH <br />AND HEEL HEIGHT ON EXISTING HOUSE TO MATCH 1d1 <br />FOR NEW ADDITION. TRUSS MANUFACTURE TO VERIFY O <br />12 WITH OWNER PRIOR TO MANUFACTURING TRUSSES <br />z O <br />1/2" CDX ROOF SHEATHING NAILED PER W z <br />ROOF SHEATHING DETAIL WITH SD NAILS, <br />USE STEEL PLYCLIPS, GAF UNDERLAYMENT <br />ENGINEERED ROOF TRUSSES AND GAF SHINGLES Q Q O <br />R-30 INSULATION IN ATTIC AREAS <br />(:) (-) n r-) C) C) r) %r) C) c� C:) C) c� <br />1/2" CEILING GYPSUM BOARD DBL 2X4 02 SPRUCE TOP PLATE WOOD 2X4 FASCIA WITH <br />WOOD SOFFIT TO MATCH <br />DBL 2X10 02 PINE WITH I/2" PLYWOOD EXISTING zO ^ <br />FILLERS OVER ALL OPENINGS WITH DBL u <br />STUD PACK UNDER BEAM AT EACH END. <br />STRAP HEADER TO STUD PACK WITH ,w n) <br />SIMPSON LSTAIB STRAPS AND FILL NAIL l VJ O O <br />HOLES WITH IODXI 1/2" NAILS 1/2" CDX PLYWOOD WALL SHEATHING LAP DOWN O L <br />OVER RIM BEAMS AND NAILED 311 OC ON ALL <br />WOOD WINDOWS PLATES AND 4" OC ON STUDS WITH 8D NAILS Z Ul <br />COVER WITH TYVEK HOUSE WRAP AND INSTALL LU <br />WOOD SIDING TO MATCH EXISTING <br />1/2 LE.- <br />GYPSUM WALL BOARD O <br />c Owf-(/ <br />2X4 02 SPRUCE ® 16" OC SIMPSON MSTA30 STRAP AT EACH SIDE OF uj <br />n O i�- <br />R-13 INSULATION IN WALLS ALL OPENINGS, EACH CORNER AND AT END �!' �- <br />OF NEW WALLS AND SPACED MAXIMUM 32" OC O }— *t 3: <br />DOWN ON FACE OF FLOOR JOIST AND STUD IN SGL 2X4 02 SPRUCE BOTTOM PLATE 1�- <br />WALL. FILL NAIL HOLES WITH IODXI 1/2 V NAILS O <br />N , n uj <br />3/4 T4G PLYWOOD GLUED AND `� �-► I <br />NAILED WITH 10D NAILS 6" OC (2) 2X8 PT <br />(4) 2X8 PT <br />1211XI2" BLOCK PIER WITH (2) VERTICAL 05 REBAR <br />IN CENTER FROM 24"X24"X12" FOOTING PAD WITH <br />(3) •5 REBAR EACH WAY. POUR PAD AND FILL <br />SECURE JOIST TO BEAMS WITH 2X8 PT JOIST s 19," OC PIER WITH MINIMUM 2500 PSI CONCRETE <br />SIMPSON U26 HANGERS. FILL <br />NAIL HOLES WITH IODXI 1/2" GRADE <br />NAILS SECURE ALL BEAMS TO TOP OF PIERS WITH �, <br />0 (1) SIMPSON HEAT20 STRAP POURED IN TOP \��®1 s y4 <br />OF PIER AND FILL NAIL HOLES WITH IODXI 1/2" `�� .Z► •0410 ems° <br />NAILS ♦ .1 0 6 <br />2' 0" 2' 0" <br />R T.L, HANWIN-16,1E. If EiE NO. 38654 <br />BOTTOM OF FOUNDATION B:)TTOM OF FOUNDA ION ® • P. OX1128, DY, FL 33526 <br />MIN MUM 12" BELOW GRADE MINIMUM 12" BELOW GRADE MOO i ATE .ow <br />IERE Y THTH '�4ANS AND SPECIFICATIONS <br />11 �R MY DIRECT SUPERVISION <br />}''� I I I t DETAIL <br />� t /� ARE I e " " I ER 16, SECTION 1609 OF THE <br />IBU I LD I I V G C lei I SECTION D E I A I L FLORIDA 6TH ADDITION AND ASCE 1-10 2 OF 4 <br />FOR 139 MP F ( ISK CATEGORY If AND THE ENTIRE <br />NOT TO SCALE 2011 BUILDING CODE RESIDENTIAL 6TH ADDITION <br />