Laserfiche WebLink
I <br />1. SPECIFICATION5 <br />1. 1. <br />CONSTRUCTION : <br />1. 1.1. <br />AGI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE <br />1. 1.2. <br />AGI 530/A5GE 5/TM5 402-16 SPECIFICATIONS FOR MASONRY STRUCTURES. <br />1. 1. 3. <br />A5TM C210, C416, C210 AND Gq0 SPECIFICATIONS FOR MA50NRY STRUCTURES <br />1. 1. 4. <br />NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION 1 qq1 EDITION AND <br />ALL ACCOMPANYING SUPPLEMENTS. <br />1. 1. 5. <br />ASTM Gg26 SPECIFICATIONS FOR ARCHITECTURAL FINISH. <br />1. 1. 6. <br />2020 FLORIDA BUILDING CODE (A5GE 1.16). <br />1.2. <br />DESIGN: <br />1. 2.1. <br />AGI 316-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE <br />1. 2.2. <br />AC I 530/A5CE 5/TM5402-16 SPECIFICATIONS FOR MASONRY STRUCTURES. <br />1. 2.3. <br />ASTM SPECIFICATIONS FOR MASONRY STRUCTURES <br />1. 2. 4. <br />NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION 1ggl EDITION AND <br />ALL ACCOMPANYING SUPPLEMENTS. <br />1. 2. 5. <br />PLYWOOD DESIGN SPECIFICATIONS <br />1. 2. 6. <br />2020 FLORIDA BUILDING CODE (A5GE 1-16). <br />1.3. <br />GEOMETRIC CONTROL: <br />1. 3. 1. <br />ELEVATIONS ARE BASED ON NAVD 1 q88 <br />1.4. <br />SHOP ORAWING5: <br />1. 4. 1. <br />THERE SHALL NOT BE ANY DEVIATIONS FROM THESE <br />DESIGN PLANS BY OTHERS DURING THE PREPARATION <br />OF SHOP DRANING5 WITHOUT WRITTEN APPROVAL <br />FROM THE ENGINEER OF RECORD. <br />1.4. 2. <br />ALL SHOP DRAWINGS ARE TO BE SUBMITTED TO THE <br />ENGINEER OF RECORD PRIOR TO THE <br />COMMENCEMENT OF CONSTRUCTION. <br />1. 4. 3. <br />ALL ROOF AND FLOOR TRUSS SHOP DRAWINGS ARE <br />TO BE SIGNED AND SEALED AND SHALL INCLUDE; <br />DRAWINGS AND CALCULATIONS, REACTIONS AND <br />BEARING POINTS, BRAUN6 REQUIREMENTS, LIFTING <br />LOCATIONS, AND CONNECTIONS TO SUPPORTING <br />TRUSS MEMBERS. <br />2. DESIGN LOAD5 <br />DEADLOADS: <br />2. 1. 1. <br />UNIT WEIGHT OF SOIL, COMPACTED: 120 PGF <br />2. 1. 2. <br />UNIT WEIGHT OF REINFORCED CONCRETE: 150 PGF <br />2. 1. 3. <br />UNIT WEIGHT OF 8" G.M.U. BLOCK: 55 P5F <br />2. 1. 4. <br />15T FLOOR SUPERIMPOSED LOAD: 20 PSF <br />2. 1.5. <br />UNITNEI6HT OF 2x4 PARTITION YVALL5 : b PSF <br />2. 1. 6. <br />UNIT WW EIGHT OF 2xb BEARING ALLS : 12 PSF <br />2.1.11. 1. <br />2ND FLOOR SELF NF16HT : 8 P5F <br />2. 1. 8. <br />2ND FLOOR 5UPERIMP05ED LOAD: 20 PSF <br />2. 1. q. <br />ROOF SELF WEIGHT: 20 PSF <br />2. 1. 10. <br />ROOF SUPERIMPOSED LOAD: 20 PSF <br />2. 1. 11. <br />FLOOR TRU55 <br />TOP CHORD MINIMUM 25 PSF <br />BOTTOM CHORD MINIMUM 5 PSF <br />2. 1. 12. <br />ROOF TRUSS <br />TOP CHORD MINIMUM 10 PSF <br />BOTTOM CHORD MINIMUM 10 P5F <br />2.2. <br />LIVE LOADS <br />2. 2. 1. <br />SIDEWALK AND DRIVEWAY LOAD: 200 P51, <br />2.2.2. <br />GARA6E LOADS: 50 P5F <br />2.2.3. <br />CORRIDORS AND BATHROOMS: 80 PSF <br />2.2.4. <br />PARTITIONED ROOMS 40 PSF <br />2. 2. 5. <br />BALCONY AND DECKS: 40 P5F <br />2. 2. 6. <br />STAIRWAYS AND LANDINGS: 100 PSF <br />2. 2. 1. <br />ROOF: 30 P5F <br />2.2.8. <br />FLOOR TRUSS <br />TOP CHORD MINIMUM: 40 PSF <br />BOTTOM CHORD MINIMUM: 10 PSF <br />2 2 q• <br />ROOF TRUSS <br />TOP CHORD MINIMUM: 20 PSF <br />BOTTOM CHORD MINIMUM: 0 PSF <br />2 3 <br />RAILING LOADS: <br />2. 3. 1 . <br />ALL RAILING AND GUARD RAIL SYSTEMS ARE TO BE <br />DESIGNED TO WITHSTAND A CONCENTRATED LOAD OF <br />200 POUNDS APPLIED AT ANY POINT AND IN ANY <br />DIRECTION AND 50 POUNDS/LIN. FT. <br />2.4. <br />NIND LOA05 : <br />2. 4. 1. <br />WIND DESIGN TO BE CONDUCTED IN ACCORDANCE WITH THE 2020 FLORIDA BUILDING <br />CODE (A5GE 1-16) AND BASED ON NIND SPEED NOTED ON COVER SHEET. <br />2. 4. 2. <br />UPLIFT VALUES ARE SHONN ON THE DESIGN DRAWINGS OR ON THE TRUSS <br />MANUFACTURER'5 CERTIFIED DRANING5 <br />2.5. <br />THERMALFORCE5: <br />2. 5. 1. <br />SEASONAL VARIATION FOR DESIGN AND <br />CONSTRUCTION : 10 F <br />MEDIAN TEMPERATURE: 25 F <br />TEMPERATURE RISE: 35 F <br />TEMPERATURE FALL: <br />2. 5. 2. <br />MEDIAN RELATIVE HUMIDITY: 15 % <br />2.6. <br />CREEP AND <br />SHRINKAGE : <br />2. 6. 1. <br />ALL LOSSES IN ACCORDANCE WITH AU 31b-16 <br />2.1. <br />SEISMIC LOADS: <br />2. T. 1. <br />SEISMIC PERFORMANCE CATEGORY'A' <br />2. b. <br />DEFLECTIONS: <br />2. 8. 1. <br />FLOOR TRUSSES SHALL LIMIT DEFLECTION TO 1 /360 <br />TIMES THE SPAN FOR LIVE LOADS AND 1/240 TIMES <br />THE SPAN FOR TOTAL LOAD. <br />GENERAL <br />3. DE516N METHOD <br />3.3. LOAD FACTOR <br />DESIGN <br />1' 3.1. <br />THE LOAD FACTOR DESIGN METHOD I NAS USED TO <br />1. <br />DESIGN: <br />CAST -IN -PLACE CONCRETE SLABS AND <br />FOOTINGS <br />3.2. 5ERVIGE <br />LOAD DESIGN: <br />3.2. 1. <br />THE SERVICE LOAD DESIGN METHOD WAS USED TO <br />DESIGN: <br />MASONRY Y IALL5 AND LINTELS <br />INTERIOR AND EXTERIOR WOOD FRAMING AND <br />SHEATHING STAIRS AND FLOOR FRAMING <br />ROOF FRAMING, SHEATHING AND UP LIFT <br />3.3. LOAD FACTORS <br />AND COMBINATIONS <br />3.3. 1. <br />THE FOLLOWING LOAD COMBINATIONS WERE DESIGNED <br />FOR: <br />TOTAL DL + FLOOR LL + ROOF LL <br />TOTAL DL + FLOOR LL + VIL <br />TOTAL DL + NL <br />3.3.2. <br />IN THE CASE OF WIND LOADS, AN ALLOWABLE OVER <br />STRESS OF 125 % CAN BE CONSIDERED. <br />3. 3. 3. <br />ALL ROOF AND FLOOR TRUSSES SHALL BE DESIGNED <br />TO RESIST THE NOR5T LOAD COMBINATION <br />RESULTING IN THE MAXIMUM 5TRE55E5 PLACED ON <br />THAT COMPONENT. BOTH PARTIAL, FULL, AND <br />ALTERNATING SPAN LOADING ARE TO BE <br />CONSIDERED. <br />3.4. DE516N <br />ASSUMPTIONS : <br />3. 4. 1. <br />FOUNDATIONS ARE DESIGNED BASED ON A <br />PRESUMPTIVE BEARING CAPACITY AS NOTED ON <br />THE COVER SHEET, ON UNDISTURBED SOIL OR ROCK. <br />3. 4. 2. <br />ALL FOUNDATIONS ARE CENTERED UNDER SUPPORTED <br />COLUMNS AND HALLS UNLE55 5HONN OTHERN15E IN <br />THE DESIGN PLANS. <br />4. MATERIALS <br />4. 1. REINFORCING STEEL: <br />4. <br />4. 1. 1. <br />REINFORCING STEEL SHALL BE ASTM A615 GRADE <br />40, N - 40 Ksi <br />4. 1. 2. <br />REINFORCING LAP SPLICES SHALL BE 40 BAR <br />DIAMETERS IN LENGTH UNLESS OTHERWISE NOTED. <br />4. 1. 3. <br />ALL DIMENSIONS PERTAINING TO THE LOCATION OF <br />REINFORCING ARE TO THE CENTERLINE OF EACH BAR <br />EXCEPT WHERE THE COVER DIMENSION 15 5HONN TO <br />THE FACE Of THE CONCRETE, <br />4. 1. 4. <br />REINFORCING DETAIL DIMENSIONS ARE OUT TO OUT <br />OF BARS. <br />4. 1. 5. <br />REINFORCING MECHANICAL COUPLERS ARE TO <br />DEVELOP 125 % OF THE REQUIRED YIELD 5TREN&TH <br />OF THE BAR AND ARE TO BE APPROVED BY THE <br />ENGINEER OF RECORD. <br />4. 1. 6. <br />DES16N COVER REQUIREMENTS: <br />C-I-P CONCRETE FORMED AGAINST EARTH: <br />3 <br />C-I-P CONCRETE FXF05ED TO EXTERIOR: <br />2 <br />C-I-P CONCRETE NOT EXPOSED: <br />1 1/2" <br />GROUT FILLED MASONRY: <br />3/4" <br />PRE STRESSED CONCRETE LINTELS: <br />1 112" <br />PRE CAST GROUT FILLED LINTELS : <br />1 1/2" <br />4. 2. CONCRETE <br />4.2. 1. G-I-P CONCRETE <br />G-I-P GROUT <br />PRE CAST CONCRETE. LINTELS <br />PRE STRESSED CONCRETE LINTELS <br />MIN.28 <br />I;A*IGN <br />MODULUS <br />STICIT <br />500 Psi <br />§, 00 Ksl <br />2,500 Psi <br />2,500 Ksl <br />3 000 Psl <br />400011 <br />5 000 Psi <br />3,200 Ksi <br />4.12. CONCRETE SHALL CONSIST OF 1" MAXIMUM <br />AGGREGATE CONCRETE MIX WITH SLUMP BETWEEN <br />b"ANDT"AT TIME OF PLACEMENT. SEE <br />SPECIFICATIONS FOR ADDITIONAL CRITERIA. <br />4 2 3 GROUT SHALL CON515T OF PEA ROCK (316" <br />MAXIMUM AGGREGATE) CONCRETE MIX NITH SLUMP <br />BETWEEN 8" AND 10" AT TIME OF PLACEMENT. <br />SEE SPECIFICATIONS FOR ADDITIONAL CRITERIA. <br />4.2.4. CONSTRUCTION JOINTS HILL BE PERMITTED ONLY <br />AT THE LOCATIONS INDICATED ON THE PLANS. <br />ADDITIONAL CONSTRUCTION JOINTS OR <br />ALTERATIONS TO THOSE SHONN SHALL REQUIRE <br />WRITTEN APPROVAL FROM THE ENGINEER OF <br />RECORD. <br />4.2. 5. METHOD OF CONCRETE FORMING, PLACEMENT AND <br />CURING SHALL BE CONDUCTED IN ACCORDANCE <br />WITH THE SPECIFICATIONS AS STATED. <br />4. 2. 6. AFTER EXCAVATION FOR FOUNDATIONS, EXISTING <br />SOILS SHALL BE COMPACTED TO A DEPTH OF 24" <br />MIN. BELON PROPOSED BOTTOM OF FOOTINGS TO A <br />MINIMUM DENSITY OF q5% MODIFIED PROCTOR. <br />UPPER SOILS (NITHIN 8" BELOW SLABS, FOUNDATIONS <br />OR PAVEMENTS) SHALL BE COMPACTED TO A <br />MINIMUM OF q8% MODIFIED PROCTOR. <br />4.2. 1. FILL MATERIALS BROUGHT ONTO 517E SHALL HAVE <br />,TARGET MINIMUM DRY DENSITY OF q5 PGF <br />GREATER AND SHALL BE GLEAN OF ALL DEBRIS <br />AiROANIC <br />MATTER. <br />4.2.8, AFTER COMPACTION, ALL 501LS TO BE COVERED BY <br />FOUNDATIONS, SLABS, OR PAVEMENT NITHIN 5' OF <br />BUILDING SHALL BE TERMITE TREATED IN <br />ACCORDANCE WITH FBG SECTION 1516. <br />MIN. 28 DAY <br />TYPE <br />F'm <br />1, q00 Psi <br />II <br />F', <br />s <br />4.3. CONCRETE MA50NRY: 21 <br />4. 3. 1. <br />LOAD BEARING CONCRETE MA50NRY BLOCK <br />MORTAR: ASTM G210 <br />4. 3. 2. <br />LOAD BEARING CONCRETE MASONRY BLOCK SHALL BE <br />A5TM CqO, TYPE II NON-MO15TURE CONTROLLED. <br />4. 3. 3. <br />ADMIXTURES ARE NOT TO BE ADDED TO THE MORTAR <br />WITHOUT WRITTEN APPROVAL FROM THE ENGINEER <br />OF RECORD. <br />4.3.4. <br />THE AGGREGATE STRENGTH OF THE BLOCK AND <br />MORTAR SHALL BE F'm - 1,g00 PSI MINIMUM. <br />4. 3. 5. <br />METHOD OF CONCRETE MASONRY PLACEMENT AND <br />CONSTRUCTION SHALL BE CONDUCTED IN <br />ACCORDANCE WITH THE SPECIFICATIONS AS STATED, <br />4. 3. 6. <br />JOINT REINFORCING SHALL CONSIST OFW <br />"LADDER -TYPE" BY DURO-ALL OR EQUAL WITH <br />ASTM A641, GLASS 1 GALVANIZED COATING. PLACE <br />AT 16" O.G. VERTICALLY, FULLY EMBEDDED IN <br />MORTAR JOINT. LAP 8" MINIMUM AT MASONRY <br />WALL CORNERS AND INTERSECTIONS. PROVIDE <br />FABRICATED ELL5, TEES OR BENDS OF <br />DISCONTINUOUS WIRES TO PROVIDE 3" HOOK AT <br />OUTSIDE OF CORNERS. EMBED REINFORCING b" <br />MINIMUM INTO TIE COLUMNS AT CORNERS AND END <br />W OF ALLS. CONTINUE REINFORCING THROUGH TIE <br />COLUMNS AWAY FROM WALL ENDS (COMMERCIAL <br />APPLICATION ONLY). <br />4. STRUCTURAL LUMBER: <br />4. <br />4. 4. 1. <br />4. <br />S. <br />MAXIMUM DESIGN VALUES <br />MODULUS <br />ELASTICITY <br />BENDING <br />TENSION <br />SHEAR <br />1,500 Psi <br />825 Psi <br />q0 P51 <br />1,600 Ksi <br />1,200 Psi <br />650 PSI <br />110 Psi <br />1,600 Ksl <br />1 300 Psi <br />25 Psi <br />CIO Psi <br />1,100 Ksl <br />INTERIOR FRAMING 2x(4) <br />EXTERIOR FRAMING 2x(6 AND 8) <br />FLOOR FRAMING 2x(8 AND 10) <br />4. 4. 2. ALL PLYWOOD USED FOR EXTERIOR <br />APPLICATIONS SHALL CONFORM TO VOLUNTARY <br />PRODUCT STANDARD P5 1-83 AND SHALL BE APA <br />RATED 5HEATHIN6 EXP 3. <br />4. 4. 3. ALL PLYWOOD USED FOR INTERIOR APPLICATIONS <br />SUCH AS SUB FLOORING AND SHEAR HALLS SHALL <br />CONFORM TO VOLUNTARY PRODUCT STANDARD <br />PS 1-83 AND SHALL BE APA RATED SHEATHING EXP <br />1 OR 2. <br />4. 4. 4. IF 05B BOARD 15 TO BE USED IN PLACE OF <br />PLYWOOD 15 TO HAVE 51MILAR SECTION <br />PROPERTIES, <br />4. 4. 5. ONLY STRUCTURAL LUMBER TO BE USED FOR AN <br />EXTERIOR APPLICATION AND IN CONTACT WITH <br />CONCRETE 15 TO RECEIVE A STANDARD GRADE <br />PRESSURE TREATING. <br />4. 4. 6. PRESSURE TREATED STRUCTURAL LUMBER 15 NOT <br />TO BE USED FOR ANY INTERIOR FRAMING EXCEPT BELON <br />FLOOD PLANE FOR ANY LUMBER ATTACHED TO CONCRETE <br />4. 4. 1. WHEN PRE ENGINEERED TRUSSES AND JOISTS ARE <br />GALLED FOR ON THE PLANS THE MANUFACTURER <br />15 TO SUBMIT SHOP DRANING5 TO THE ENGINEER <br />OF RECORD. <br />FASTENERS AND TIE DOWNS: <br />FASTENERS AND TIE 00NN5 SHALL CON515T OF <br />BUT ARE NOT LIMITED TO: <br />SHAPES, ANGLES, CHANNELS: ASTM A36 Fy - <br />36 Ks' <br />ROUND METAL PIPE: ASTM A53, GRADE B Fy <br />- 35 Ksi <br />SQUARE METAL TUBING: ASTM A500, GRADE <br />B Fy - 46Ksl <br />H16H STRENGTH BOLTS: ASTM A325 <br />MACHINE BOLTS: GALVANIZED ASTM A301 <br />4. 5. 2. SHEET METAL ACCE55ORIE5 SHALL CONFORM TO: <br />ASTM A446 OR ASTM A526 Fy = 33 Ksi KITH Gq0 <br />GALVANIZED COATING IN ACCORDANCE KITH <br />A5TM A525. <br />4. 5. 3. NAILS SHALL CONSIST OF: COMMON WIRE NAILS <br />WITH MINIMUM DIAMETER AS FOLLOW5 : bd = <br />0.113", 8d = 0.113", 10d - 0.113", 1 bd = 0.113". <br />4. 5. 4. ALL FASTENERS AND TIE DOWNS EMBEDDED IN <br />CONCRETE OR USED IN AN EXTERIOR <br />APPLICATION OR USED IN P.T. WOOD ARE TO RECEIVE AN <br />ANTI -CORROSIVE COATING PRIOR TO <br />INSTALLATION. <br />4. 5. 5. <br />ALL FASTENERS AND TIE DOWNS ARE TO <br />PROVIDE THE UPLIFT CAPACITY GALLED FOR IN <br />THE PLANS A5 A MINIMUM. <br />4. 5. 6. <br />ALL FASTENER TIE DOWNS, BEAM HANGERS, JOIST <br />HANGERS, AND FLOOR TRUSS STRAPPING ARE TO <br />BE INSTALLED IN ACCORDANCE WITH THE PLANS <br />AND SPECIFICATIONS. <br />4. S. T. <br />CONCRETE EMBEDDED'.' BOLTS USED FOR UPLIFT <br />ARE TO BE WET SET PRIOR TO INITIAL SET OF THE <br />CONCRETE, SPACING AND ALIGNMENT ARE TO BE <br />IN ACCORDANCE WITH THE DESIGN PLANS. <br />CONCRETE EMBEDDED TIE DOWNS USED FOR <br />TRUSS AND HALL UPLIFT ARE TO BE PLACED <br />AROUND EMBEDDED REINFORCING PRIOR TO <br />PLACING GROUT. <br />GENERAL NOTES <br />1. ALL WORK SHALL BE EXECUTED IN ACCORDANCE WITH THE FL, BLDG. CODE AND SHALL FOLLOW ALL LOCAL CODE, RULES, REGULATIONS, AND ORDINANCES. <br />2. ALL WORK SHALL BE COMPLETED IN A NEAT AND CRAFTSMANLIKE MANNER AND UPON COMPLETION SHALL BE INSPECTED BY THE GENERAL CONTRACTOR AND OWNER PRIOR TO FINAL PAYMENT BEING <br />ISSUED. <br />3. ALL SUB -CONTRACTORS SHALL BE RESPONSIBLE FOR THE DISPOSAL OF THEIR RELATED REFUSE; REFUSE SHALL BE RECYCLED TO THE GREATEST EXTENT POSSIBLE. <br />4. ALL CONDITIONS, DRAWINGS, DIMENSIONS, ETC. SHALL BE FIRST VERIFIED BY THE GENERAL BLDG CONTRACTOR AND SUB -CONTRACTORS AND OWNER PRIOR TO THE ORDERING OF MATERIALS <br />AND CONSTRUCTION FOR DELETIONS, ERRORS, AND/OR OMISSIONS. FAILURE TO NOTIFY THE ARCHITECT SHALL RELIEVE THE ARCHITECT FROM RESPONSIBILITY AND CORRECTIVE COSTS. <br />5. ANY ALTERATION OR DEVIATION FROM THESE PLANS SHALL BE MADE WITH THE COMBINED APPROVAL OF THE OWNER AND THE ARCHITECT. ITEMS NOT APPROVED SHALL RELIEVE THE OWNER <br />AND THE ARCHITECT OF RESPONSIBILITY AND ANY COSTS TO CORRECT THE ALTERATION OR DEVIATION. <br />6. ALL FOUNDATIONS AND SLABS SHALL BE CONSTRUCTED ON TERMITE -TREATED SOILS THAT ARE UNDISTURBED OR WELL -COMPACTED TO MIN. 95% (MODIFIED PROCTOR TESTING). <br />7. ALL GLAZING IN WINDOWS AND DOORS SHALL BE IMPACT -RESISTANT GLASS OR PROTECTED. SEE <br />8. NO SURFACE DRAINAGE SHALL DRAIN ONTO ADJACENT PROPERTIES. <br />9. GRADE ELEVATIONS SHOWN ARE BASED UPON 1988 NAVD. <br />10. REINFORCING STEEL SHALL BE ASTM A615, GRADE 40 (fy = 40 KSI), U.O.N. 11. LAP SPLICES FOR REINFORCING STEEL SHALL BE A MINIMUM OF 26" FOR #5 BARS AND 20" FOR #4 BARS (36 BAR DIAMETERS, <br />TYP), <br />11. ALL FOUNDATIONS ARE CENTERED UNDER SUPPORTED COLUMNS AND WALLS, UNLESS SHOWN OTHERWISE BY DIMENSIONS ON THE DRAWINGS. <br />12. PROVIDE THE FOLLOWING COVERAGES ON REINFORCING STEEL IN CONCRETE TYP: <br />a. C-I-P CONCRETE AGAINST EARTH 3" <br />b C-I-P CONCRETE EXPOSED TO WEATHER 2" <br />DRAWING INDEX <br />CODE CONTENT <br />T <br />TITLE PAGE <br />G1 <br />GENERAL SPECIFICATIONS <br />62 <br />GENERAL SPECIFICATIONS <br />Al <br />FLOOR PLAN <br />A2 <br />ELEVATIONS <br />A3 <br />3D VIEWS <br />S1 <br />FOUNDATION PLAN <br />ROOF FRAMING PLAN <br />S2 <br />S3 <br />DETAILS <br />DETAILS <br />D1 <br />D2 <br />DETAILS <br />D3 <br />DETAILS <br />D4 <br />DETAILS <br />E1 <br />ELECTRICAL PLAN <br />SCOPE OF 1NORK <br />NEW HOME TO BE BUILT <br />bh <br />�j( 2h IR <br />- <br />e <br />e <br />GABLE FLAT ROOF5 HIP <br />0 `- 7 !ROOFS -!s 4 <br />0 5 <br />O <br />10 0 20 <br />0�< 7 7 <br />60MP`0NENT5 AND CLADDING PRE55URE ZONES <br />a=4feet <br />e e e <br />T7 <br />- L__ <br />e In r r n e <br />GABLE R001`5 <br />7 0 7S 4 <br />5 <br />I:rT-- <br />7 *0 < 4� <br />5 <br />THE CLIENT UNDERSTANDS THAT THE DE5I6NER CARRIES NO LIABILITY INSURANCE AND <br />THEREFORE AGREES TO HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL <br />CLAIMS, LOSSES, AND EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) AR151NG OUT <br />OF OR RESULTING FROM THE PROJECT. THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO <br />PROVIDE ERROR FREE CONSTRUCTION DOCUMENTS, BUT IN THE EVENT ERRORS OCCUR <br />THE DESIGNER WILL NOT BE LIABLE FOR COST OF REPAIRS OR DELAY TO THE <br />CONSTRUCTION. <br />1/2"c. C-I-P CONCRETE NOT EXPOSED 1 " <br />d. GROUT -FILLED CMU '/." CODES FLORIDA BUILDING CODE, <br />ALL WORK SHALL CnMPI-Y WITH PREVAILING <br />e. PRE -STRESSED CONCRETE LINTELS 1 ' NATIONAL ELECTRIC CODE, <br />1/2"f. PRE -CAST GROUT -FILLED LINTELS 1 1/2" <br />AND THE CITY OF 21=PWRI'IIuL0 <br />ORDINANCES 12 IEW I <br />CODE INFORMATION <br />OCCUPANCY CLA551FICATION: 51N67LE FAMILY HOME <br />TYPE OF CONSTRUCTION: V - UNPROTECTED, UN -SPRINKLER <br />APPLICABLE CODES <br />1th EDITION (2020) FLORIDA BUILDING CODE <br />lth EDITION (2020) FLORIDA BUILDING CODE - RE51DENTIAL <br />lth EDITION (2020) FLORIDA BUILDING CODE - MECHANICAL <br />7th EDITION (2020) FLORIDA BUILDING CODE - PLUMBING <br />lth EDITION (2020) FLORIDA BUILDING CODE - EX15TING <br />7th EDITION (2020) FLORIDA BUILDING CODE - FUEL, 6A5 <br />7th EDITION (2020) FLORIDA BUILDING CODE - ACCE551BILITY <br />7th EDITION (2020) FLORIDA BUILDING CODE - ENERGY CONSERVATION <br />lth EDITION (2020) FLORIDA FIRE PREVENTION CODE <br />2011 NATIONAL ELECTRICAL CODE <br />ALL WITH APPLICABLE LOCAL AND 5TATE AMENDMENTS AND MODIFICATIONS <br />BUILDING DE51GN DATA: <br />TH15 STRUCTURE HA5 BEEN DESIGNED IN ACCORDANCE WITH <br />FLORIDA BUILDING CODE 2020.1tH EDITION. <br />R15K CATEGORY II <br />R15K IMPORTANTANCE FACTOR 1.0 <br />ULTIMATE DESIGN WIND 5PEED (3-5EC GU5T - Vult) 145 mph <br />NOMINAL DESIGN WIND 5PEED (Va5d) 116 mph <br />DO WIND-BORNE DEBR15 PROV15ON5 APPLY YE5 <br />DIRECTIONALITY FACTOR 0.55 <br />WIND EXP05URE/5URFAGE ROUGHNE55 CATEGORY B <br />EXP05URE CLA551FIGATION B <br />INTERNAL PRE55URE COEFFICIENT 0.18 <br />SNOW LOADS N/A <br />HEIGHT & EXP05URE ADJU5TMENT COEFF: 1.00(max.30') <br />[-STRUCTURAL 0E51GN CRITERIA <br />DE5167N FLOOR LIVE LOAD - UNIFORM LOADING = 40 P5F <br />DE5167N FLOOR LIVE LOAD - CONCENTRATED LOADING (4 5a IN) = 300 LB5 <br />DE51ON LIVE LOAD - GAR PORT/DRIVEWAY = 200 P5F <br />DE516N ROOF LIVE LOAD - UNIFORM LOADING = 20 P5F <br />DESIGN LOAD -BEARING VALUE FOR 501L5 (FOUNDATION5) = 2000 P5F <br />DE5167N WIND LOADS - DOOR5, WINOOW5,COMPONENT AND CLADDING DE516N5 <br />ZONE <br />PRE55URE5 (P5F) <br />P051TIVE <br />NEGATIVE <br />HIP ROOF -5LOPE (20",-21") <br />VULT <br />(ZONE 1) <br />+13.1 P.5.F. <br />-20.5 P.5.F. <br />2e.2r,& 3 <br />13.1 P.5.F. <br />-35.5 P.5.F. <br />GABLE ROOF - 5LOPE (20--27") <br />1 & 2a <br />+15 1 P.5.F. <br />-34.6 P.5.F. <br />2n, 2r & 3e <br />+ 18.1 P.5.F. <br />-55.2 P.5.F. <br />3r <br />+15.1 P.5.F. <br />-55.4 P.S.F. <br />WALL5 <br />4 <br />+24.3 P.5.F. <br />-26.3 P.5.F. <br />5 <br />+24.3 P.5.F. <br />- 32.5 P.5.F. <br />ADJUSTED FOR EXP05URE AND HEIGHT <br />h= 26FT. <br />a= 4 FT. <br />SQUARE FOOTAGES <br />LIVING AREA = 1,598 S.F. <br />GARAGE = 418 S.F. <br />FRONT PORCH = 30 S.F. <br />BACK PORCH = 187 S.F. <br />NEW TOTAL = 2,233 S.F. <br />ti <br />} <br />^� > q <br />INJ: 10JS.,t4t.1dt <br />�K2rvervlew.odluvl,Bnnea <br />U ° ;2� <br />Mow4dlen, PE, <br />Mou, dw, PE, <br />emaild,oi-nwnd n®9 <br />men.cm <br />Dee;2022.11,0512:48:33 <br />q <br />^O <br />q <br />V C <br />J V E-Z <br />v� L <br />W <br />W q <br />Lq <br />U <br />:zz t <br />�l [may <br />O <br />O <br />rr^� <br />Ln <br />� <br />q <br />q <br />U � <br />w <br />O <br />cO <br />rV_ <br />I <br />WMSz <br />�W <br />N <br />Q <br />W <br />W <br />ue <br />Ln ­4 <br />_A Ln <br />­4 <br />-1 <br />m M <br />rn O <br />J <br />00 <br />00 <br />Lu <br />LL _ <br />rn <br />Q -4 <br />m <br />rA <br />0c) <br />LnLn <br />11 �_ <br />Q <br />00 <br />1- a <br />LL <br />'i <br />J > <br />W <br />Ln <br />z <br />0 <br />„ <br />Ld <br />Uo <br />Zo <br />OZ <br />U< <br />0 <br />SHEET TITLE <br />TITLE <br />JOB No. <br />221-22 <br />DATE: 10/29/2020 <br />SHEET No. <br />T <br />