-:E' I :1. . l -- ,. _I 1 _II I 1 11 ! 1 11 - I I 11 1 11 1 _ 1 'I _ I I -1'._ ..-... 1 11'1 '1.. 1 1, l! .,III _.
<br />! I I I I II 111
<br />PROVIDE 4" -- 30 GAGE 5H METAL
<br />EXHAUST DUGT FROM THE
<br />TOILET FAN (MIN. 50 dfm)
<br />THROUGH THE ROOF WITH A
<br />BACK DRAFT DAMPER EXTEND
<br />DUCT b" ABOVE ROOF.
<br />PROVIDE 4" 30 GAGE 5H METAL
<br />EXHAUST DUCT FROM THE
<br />TOILET FAN (MIN. 50 dfm)
<br />THROUGH THE ROOF WITH A _
<br />BACK DRAFT DAMPER EXTEND
<br />DUCT b" ABOVE ROOF.
<br />A/C
<br />nlar.nuuFr.T
<br />ELECTRICAL - DATA - AUDIO LEGEND
<br />SYMBOL
<br />DESCRIPTION
<br />Ceiling Fan
<br />aVentilation
<br />Fans: Ceiling Mounted, Wall Mounted
<br />0 9 (D a
<br />Ceiling Mounted Light Fixtures: Surface/Pendant,
<br />Recessed, Heat Lamp, Low Voltage
<br />®
<br />Wall Mounted Light Fixtures: Flush Mounted,
<br />Wall Sconce
<br />Chandelier Light Fixture
<br />0
<br />Fluorescent Light Fixture
<br />240V Receptacle
<br />Q wP GF°
<br />110V Receptacles: Duplex, Weather Proof, GFCI
<br />$ WP 3` 4$
<br />W$
<br />Switches: Single Pole, Weather Proof, 3-Way, 4-Way
<br />DM
<br />T$
<br />Switches: Dimmer, Timer
<br />A$
<br />Audio Video: Control Panel, Switch
<br />sP sP
<br />Speakers: Ceiling Mounted, Wall Mounted
<br />C5� c5 g I:Fvl
<br />Wall Jacks: CATS, CAT5 + TV, TV/Cable
<br />g
<br />Telephone Jack
<br />g
<br />Intercom
<br />Q
<br />Thermostat
<br />o Q
<br />Door Chime, Door Bell Button
<br />so a
<br />Smoke Detectors: Ceiling Mounted, Wall Mounted
<br />EP
<br />Electrical Breaker Panel
<br />2-2/0 THHN
<br />COPPER WIRE
<br />OR 4/0 AL
<br />1-110 OR 2/0
<br />3-3/0 THAV IN
<br />2"
<br />13MMUIT
<br />200
<br />AWBED
<br />2" 2
<br />DISCONECT
<br />SCRAIIBS
<br />1
<br />METE
<br />TYP
<br />0
<br />R __
<br />FUSES
<br />n
<br />3
<br />A.
<br />#4 CU.
<br />)HIRE
<br />6'
<br />MIN.
<br />GALV. CW
<br />— RQDNG = PIP
<br />TYP.
<br />E
<br />ELECTRICAL RISER DIAGRAM N.T.S.
<br />GENERAL NOTE5:
<br />ELECTRICAL PLAN 15 INTENDED FOR BID PURP05E5 ONLY.
<br />ALL WORK SHALL BE DON IN 5TRICT ACCORDANCE WITH
<br />NATIONAL ELECTRICAL CODE LATE5T EDITION BY A LICENSED
<br />ELECTRICAL CONTRACTOR WHO 5HALL BE RE5PON51BLE FOR
<br />THE IN5TALLATION5 AND 51ZIN6 OF ALL ELECTRICAL EQUIPMENT
<br />WIRING AND ACCE55ORIE5.
<br />- NOTE- - - - -
<br />ALL TELEVISION (RG-b, TELEPHONE (GAT 5E),
<br />AND ETHERNET (GAT 5E) WIRE5 TO BE
<br />TERMINATED IN GARAGE OR DESIGNATED
<br />LOCATIONS.
<br />NOTE
<br />ALL NEW SMOKE/CARBON MONOXIDE DETECTORS
<br />TO BE MOUNTED ON CEILING OR WALL INSIDE
<br />AND OUTSIDE OF EACH 5LEEPIN6 ROOM AND
<br />HARD WIRED FOR COMMON ALARM WITH
<br />BATTERY BACKUP.
<br />DWELLING TO HAVE SMOKE/CARBON MONOXIDE
<br />DETECTORS A5 PER 2005 N.E.G.
<br />ARCH FAULT PROTECTION AND TAMPER PROOF
<br />RECEPTACLES PROVIDED ON ALL NEW
<br />CONSTRUCTION.
<br />ALL ELECTRICAL EQUIPMENT, J-BOXE5, AND
<br />WIRING TO BE INSTALLED ABOVE B.F.E. (IF
<br />APPLICABLE)
<br />SMOKE ALARM:
<br />• All smoke alarms shall be listed and
<br />labeled in
<br />accordance with UL 217 and installed in
<br />accordance
<br />with the provisions of Florida Building Code
<br />7th
<br />Edition (2020) Residential Section-R314 (See
<br />exceptions also) and the household fire
<br />warning
<br />equipment provisions of NFPA 72
<br />• CCO2 detectors are required if fossil fuel
<br />appliances
<br />are installed in the dwelling. Inspectors to
<br />determine
<br />need at the time of the inspection.
<br />NOTE
<br />ALL ELECTRIC, GAS, MECHANICAL, AND
<br />PLUMBING TO BE ABOVE B.F.E.
<br />- WnTF
<br />ALL RECEPTACLES IN KITCHEN AND GARAGE
<br />TO BE GFI/GFCI (TYP.)
<br />ALL EXTERIOR RECEPTACLES TO BE GFI/GFCI
<br />W/ WEATHERPROOF COVERS
<br />ALL NEW INTERIOR RECEPTACLES TO BE AFGI
<br />(TYP.)
<br />PROVIDE SEPARATE NEUTRAL WIRE5 FOR ALL
<br />CIRCUITS; NO COMMON NEUTRAL WIRES SHALL
<br />BEINSTALLED
<br />ALL FIXTURES TO BE CENTERED IN BAYS
<br />BETWEEN STRUCTURAL ELEMENTS, CABINETS,
<br />WALKWAYS, ETC. WHERE CONFLICTS BETWEEN
<br />TRU55E5 AND THE ABILITY TO CENTER
<br />FIXTURES, CONSULT OWNER OR ARCHITECT
<br />PRIOR TO ROUGH -IN.
<br />L L -J
<br />J LED LEDGER LiS.
<br />* ALL ELECTRICAL FIXTURES (LIGHTS)
<br />FURNISHED BY ELECTRICIAN TO
<br />INCLUDE LIGHT BULBS. (GF OR LED, TYP)
<br />* ALL 5WITGHE5 AND RECEPTACLES
<br />TO BE WHITE DECORA EXCEPT
<br />WHERE BROWN, BLACK OR
<br />STAINE55/STEEL 15 REQUIRED.
<br />* ALL CEILING FANS TO BE
<br />WIRED WITH 3 WIRE CONF.
<br />* ALL RECESS LIGHTS TO BE LED
<br />* ALL LIGHTS TO BE ON DIMMER SWITGHE5
<br />ELECTRICAL CONSTRUCTION
<br />NOTE
<br />l . All work shall be in accordance with the
<br />National Electrical Code (NEC), latest edition,
<br />and applicable state and local ordinances.
<br />Each peace of electrical equipment installed
<br />shall bear a U.L label. All work shall be
<br />performed in compliance with the
<br />Occupational Safety and Health Act (osha)
<br />latest edition.
<br />2. The electrical contractor shall arrange and
<br />pay for all permits, fees, inspections, etc,
<br />and carry all insurance as required by law
<br />prior to starting construction (If applicable)
<br />3. The electrical contractor shall provide all
<br />necessary labor, materials, transportation,
<br />rigging, tools, storage, etc. for all work
<br />indicated and required for a complete
<br />installation
<br />4. All electrical equipment, materials, and
<br />workmanship shall be guaranteed for a
<br />period of one (1) year from date of
<br />acceptance.
<br />5. In general, plans are schematic only, and
<br />should not be scaled. Coordinate all
<br />electrical work with other trades, so as not
<br />to conflict in location at performance of
<br />others systems.
<br />6. Necessary, obviously required electrical items
<br />that are not shown on the drawings, does
<br />not relieve the contractor of his
<br />responsibility to install a complete and safe
<br />electrical system.
<br />7. All equipment shall be properly grounded in
<br />all raceways, branch circuits and feeders,
<br />per local electrical codes and the NEC.
<br />K. All lighting fixtures shall be selected by the
<br />owner and installed by the electrical
<br />contractor. (Lighting fixtures indicated on
<br />drawings and schedules are for reference
<br />only, fixtures of equal quality may be used
<br />as directed)
<br />9. All electrical equipment exposed to weather
<br />shall be weatherproof and all conduit
<br />exposed to weather shall be heavy wall
<br />galvanized steel.
<br />WHERE APPLICABLE
<br />1. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS
<br />REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
<br />AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES.
<br />2, PROVIDE AND INSTALL GROUND FAULT CIRCUIT -INTERRUPTERS
<br />(G.FI.) AS REQUIRED BY NATIONAL ELECTRIC CODE (NEC) AND
<br />MEETING THE REQUIREMENTS OF ALL GOVERNING CODES.
<br />3, ALL SMOKE DETECTORS SHALL BE HARD WIRED WITH BATTERY
<br />BACK-UP AND INTERCONNECTED (ON SAME CIRCUIT) PER FRC
<br />R613.2.
<br />4. FOLLOW GUIDELINES OF INDUSTRY STANDARDS
<br />0 I- mtD
<br />W l.n 1 j *-+
<br />-A Ln r-i
<br />� rn Ln0
<br />F- 00
<br />w r^
<br />Cl- —A �
<br />Ln Ln Q
<br />001--aU-
<br />I'1
<br />I
<br />- U Ut
<br />---I
<br />-- Cr
<br />Li
<br />z z
<br />y�)
<br />I �li L1
<br />I
<br />Q U0
<br />b 'U'
<br />SHEET TITLE
<br />ELECTRICAL PLAN
<br />JOB No.
<br />221-22
<br />DATE: 10/29/2020
<br />SCALE: 1/4" = 1'-0"
<br />SHEET No.
<br />El
<br />
|