APPROVED PRODUCTS LIST
<br />PRODUCT CATEGORY
<br />SUB -CATEGORY
<br />MANUFACTURER
<br />STATE OF FLORIDA
<br />APPROVAL NUMBER
<br />EXPIRATION
<br />DATE
<br />Structural Component
<br />Wood Connector Anchors
<br />Simpson Strong Tie Co.
<br />FL9589.5 SDS25200,SDSI/4 X 2
<br />APPROVED
<br />FL10860.6 CB44, CB46, CB48, CB66, CB68
<br />FL10456.3 Hi, HIO, HIOA, HIO-2, HIS, H15-2, H2, H2.5, H2.5A,
<br />H3, H4, H5, H6, H7Z
<br />FLI0860.12 CCQ74-SDS2.5, CCQ76, CCQ77, CCQ78
<br />FL11473.3 HETA12, HETA16, HETA20, HETA24, HETA40
<br />FL11473.4 HETAL12, HETALI6, HETAL20
<br />FL11473.9 META12, META16, METAI8, META20, META22,
<br />META24, META40
<br />FL11473.12 MTSM16, MTSM20, HTSM16, HTSM20
<br />FL10655.1 HGUS26-2, HGUS28-2, HGUS210-2
<br />FL10655.2 HGUS26-3, HGUS28-3, HGUS210-3, HGUS212-3,
<br />HGUS214-3
<br />Structural Component
<br />Concrete Lintel
<br />Cast -Crete Corporation
<br />FL158.1 HIGHT STRENGH CONCRETE LINTELS, 4, 6, 8, 12" W.
<br />APPROVED
<br />Structural Component
<br />Soffits
<br />Ply Gem Siding Group
<br />FL17636.1 VINYL AND ALUMINUM SOFFITS
<br />APPROVED
<br />Doors
<br />Exterior Doors (Swinging Door)
<br />Therma-tru Corp.
<br />FL7728.1 GLAZED STEEL DOOR (IMPACT)
<br />APPROVED
<br />FL7586.1 GLAZED STEEL DOOR (IMPACT)
<br />FL5891.1 OPAQUE FIBERGLASS (IMPACT)
<br />FL6993.1 OPAQUE FIBERGLASS 8' (IMPACT)
<br />FL7347.4 GLAZED FIBERGLASS DOUBLE (IMPACT)
<br />FL8871.6 OPAQUE FIBERGLASS (IMPACT)
<br />Exterior Doors
<br />Garage Doors
<br />Clopay Bldg Products
<br />FL5684.2 STEEL PAN, UP TO 9'
<br />APPROVED
<br />FL5684.3 STEEL PAN, 9'-2" TO 16'-2"
<br />FL5684.4 STEEL PAN, 16'-4" TO 18'-2"
<br />Exterior Doors
<br />Garage Doors
<br />Overhead Door Corporation
<br />FL14170,9 SERIES 170-175, 177, 180-185, 187 (16' MAX. WIDTH)
<br />APPROVED
<br />Doors
<br />Exterior Doors
<br />Marvin Windows & Doors
<br />FL4939.1 CLAD SLIDING DOOR (NON -IMPACT)
<br />APPROVED
<br />Doors
<br />Exterior Doors
<br />Jeld-Wen
<br />FL10976.1 VINYL BYPASS PATIO DOOR (NON -IMPACT)
<br />APPROVED
<br />FLI1109.1 ALUMINUM SLIDING DOOR (NON -IMPACT)
<br />Doors
<br />Exterior Doors
<br />PGT Industries
<br />FL253.3 ALUMINUM FRENCH DOOR (IMPACT)
<br />APPROVED
<br />Exterior Doors
<br />Roll -Up Exterior Doors Assemblies
<br />Janus International Corporation
<br />FL12765.9 SERIES 850-S, 26 GAUGE DOOR ASSEMBLY
<br />APPROVED
<br />Windows
<br />Single Hung
<br />Jeld-Wen
<br />FL14095.1 VINYL SINGLE HUNG (IMPACT)
<br />FL14095.2 VINYL SINGLE HUNG (NON -IMPACT)
<br />FL10970.1 ALUMINUM SINGLE HUNG (NON -IMPACT)
<br />FL11120.1 ALUMINUM SINGLE HUNG (IMPACT)
<br />Windows
<br />Single Hung
<br />PGT Industries
<br />FL239.2 SH-500 WINGUARD VINYL SINGLE HUNG (IMPACT)
<br />APPROVED
<br />FL239.3 SH-600 ALUMINUM SINGLE HUNG (NON -IMPACT)
<br />FL239.4 SH-700 ALUMINUM SINGLE HUNG (IMPACT)
<br />Windows
<br />Fixed
<br />PGT Industries
<br />FL243.2 CA-740 ALUMINUM FIXED WINDOW (IMPACT)
<br />APPROVED
<br />FL243.8 PW-2720 VINYL FIXED WINDOW (IMPACT)
<br />Roofing
<br />Asphalt Shingles
<br />GAF
<br />FL10124.1 FIBERGLASS REINFORCED 3-TAB,
<br />LAMINATED, 5-TAB AND HIP/RIDGE ASPHALT
<br />SHINGLES.
<br />APPROVED
<br />Roofing
<br />Barrel Tile
<br />Hanson Roof Tile
<br />FL3505.1 HACIENDA, LOW/ MEDIUM PROFILE CONCRETE
<br />APPROVED
<br />FL3505.2 HANSON FLAT, FLAT PROFILE CONCRETE
<br />FL3505.3 REGAL, HIGH PROFILE CONCRETE
<br />Roofing
<br />Built Up Roof
<br />GAF
<br />FL11946.1 CONVENTIONAL, FIBERGLASS BUR SYSTEMS
<br />APPROVED
<br />Roofing
<br />Underlayment
<br />GAF
<br />FL10626.1, FOR SLOPED ROOF SYSTEMS
<br />APPROVED
<br />FLI5487.1 SYMTHETIC ROOF UNDERLAYMENTS
<br />Roofing
<br />Ridge Vents
<br />GAF
<br />FL6267.1 LOW PROFILE ROOF RIDGE VENTS
<br />APPROVED
<br />Roofing
<br />Metal Roofing
<br />Metal Sales Manufacturing Corporation
<br />FL14645.4 5V-CRIMP, MIN. 26 GA
<br />APPROVED
<br />FL14645.5 ALUMINUM CLASSIC RIB, NOM. 0.032 THICK
<br />Panel Wall
<br />Glass Block
<br />Pittsburgh Coming Corp.
<br />FL1363.1 GLASS BLOCK MORTAR SYSTEM,GLASS BLOCK
<br />INSTALLED WITH MORTAR
<br />APPROVED
<br />ELECTRICAL
<br />KEY
<br />DUPLEX OUTLET ON THE FLOOR
<br />DUPLEX CONVENIENCE OUTLET
<br />-�
<br />TELEPHONE (OPTIONAL)
<br />DUPLEX OUTLET ABOVE COUNTER
<br />7
<br />TELEVISION (OPTIONAL)
<br />A.F.
<br />ARC -FAULT OULET
<br />OT
<br />THERMOSTAT
<br />W.P.
<br />WEATHERPROOF DUPLEX OUTLET
<br />g E,M,
<br />ELECTRIC METER
<br />&OFI
<br />GROUND FAULT INTERRUPTER DUPLEX OUTLET
<br />®BP
<br />ELECTRIC PANEL
<br />GROUND FAULT & WEATHERPROOF INT. DUPLEX OUTLET
<br />p—i
<br />DISCONECT SWITCH
<br />F.I. W.P
<br />/
<br />HALF SWITCH DUPLEX OUTLET
<br />�
<br />� SPEAKER (OPTIONAL)
<br />®-
<br />SPECIAL PURPOSE OUTLET
<br />ROUGH -IN FOR OPT. CEILING FAN
<br />DUPLEX OUTLET IN FLOOR
<br />220 VOLT OUTLET
<br />CEILING MOUNTED INCANDESCENT LIGHT FIXTURE
<br />WALL SWITCH
<br />W/ ROGH - IN FOR OPT. CEILING FAN
<br />$3
<br />THREE-WAY SWTCH
<br />�►/�
<br />4
<br />FOUR-WAY SWITCH
<br />J(�I
<br />V
<br />FLOOD LIGHT
<br />RHEOSTAT SWITCH
<br />WR
<br />�-
<br />DOOR BELL
<br />CEILING MOUNTED INCANDESCENT LIGHT FIXTURE
<br />I
<br />WALL MOUNTED INCANDESCENT LIGHT FIXTURE
<br />THEATRIAL LIGHTS
<br />'
<br />RECESSED INCANDESCENT LIGHT FIXTURE
<br />0P.C.
<br />LIGHT FIXTURE WITH PULL CHAIN
<br />PUSHBUTTQM FOR
<br />GARAGE DOOR OPPENER
<br />1
<br />TRACK LIGHT
<br />O
<br />OPT. SPEAKERS
<br />®
<br />FLUORESCENT LIGHT FIXTURE 0 UNIT)
<br />®
<br />FLUORESCENT LIGHT FIXTURE (2 UNITS)
<br />IRRIGATION OULET
<br />EXHAUST FAN
<br />A'
<br />EXHAUST FAN/LIGHT COMBINATION
<br />UNDER COUNTER OULET
<br />®
<br />ELECTRIC DOOR OPERATOR (OPTIONAL)
<br />INTERCOM CONTROL
<br />CH
<br />CHIMES (OPTIONAL)
<br />0
<br />19
<br />PUSHBUTTON SWITCH (OPTIONAL)
<br />TJ� W
<br />INTERCOM CONTROL
<br />SD
<br />SMOKE DETECTOR
<br />NOTES
<br />(.PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS
<br />REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION ( NFPA)
<br />AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES.
<br />2. PROVIDE AND INSTALL GROUND FAULT CIRCUIT-INTERUPTERS
<br />(GFI) AS REQUIRED BY NATIONAL ELECTRIC CODE (NEC) AND
<br />MEETING THE REQUIREMENTS OF ALL GOVERNING CODES.
<br />3. UNLESS OTHERWISE INDICATED , INSTALL SWITCHES &
<br />RECEPTACLES AT THE FOLOWING HEIGHTS ABOVE FINISH FLOOR:
<br />SWITCHES- 42'
<br />OUTLETS- 14'
<br />TELEPHONE-14'
<br />TELEVISION- 14"
<br />4. ALL SMOKE DETECTORS SHALL BE WIRED ON (1) CIRCUIT.
<br />5. IT IS THE RESPONSIBILITY OF THE LICENSED ELECTRICIAN TO
<br />INSURE THAT ALL ELECTRICAL WORK IS IN FULL COMPLIANCE WITH
<br />N.E.C, SBCCI - 97, AND ALL APPLICABLE LOCAL STANDARS, CODES,
<br />AND ORDINANCES.
<br />PER SECTION 210-12 ARC -FAULT CIRCUIT INTERRUPTER
<br />PROTECTION.
<br />ALL 120-VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH
<br />CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT
<br />FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS,
<br />LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS,
<br />CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE
<br />PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER,
<br />COMBINATION -TYPE, INSTALLED TO PROVIDE PROTECTION OF
<br />THE BRANCH CIRCUIT.
<br />3
<br />0
<br />16' OVERHANG
<br />ROOF VENT
<br />PER A/C CALC.
<br />METER SOCKET
<br />#4 CU TO COLD
<br />WATER PIPE &
<br />DRIVEN GROUND
<br />ROD
<br />U
<br />I-
<br />5 ✓ 12 PITCH o-
<br />---- L LO
<br />4— — — — — — — — — —
<br />L
<br />I I
<br />I Ir�l
<br />ROOF PLAN
<br />SCALE: 1/8" = V-0"
<br />OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO
<br />A ROOM USED FOR SLEEPING PURPOSES SHALL NOT
<br />BE PERMITTED. OTHER OPENINGS BETWEEN THE
<br />GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH
<br />SOLID WOOD DOORS NOT LESS THAN 13/8 INCHES
<br />IN THICKNESS, SOLID OR HONEYCOMB -CORE STEEL
<br />DOORS NOT LESS THAN 13/8 INCHES THICK, OR
<br />20-MINUTE FIRE -RATED DOORS, EQUIPPED WITH A
<br />SELF -CLOSING DEVICE PER SECTION R302.5.1 OF
<br />FLORIDA BUILDING CODE 5 th EDDITION.
<br />SINGLE PHASE BREAKER
<br />PANEL NEMA 1
<br />30 CIRCUIT
<br />O
<br />1 1/2" RIDGE NIPLE WITH
<br />2 #I AND 1 #3 CU THW
<br />CONDUCTOR
<br />BY POWER COMPANY
<br />ELCTRICAL RISER DIAGRAM
<br />SCALE: NTS
<br />200 AMPS SERVICE
<br />ALL ELECTRICAL WORK SHALL
<br />COMPLY WITH THE CURRENT
<br />NFPA70/NEC 2011 CODE.
<br />ELECTRICAL PLAN
<br />SCALE: 1/4" = V-0"
<br />ra
<br />(I GENERAL NOTES 11
<br />ALL PLUMBING, ELECTRICAL, AND
<br />MECHANICAL ROUGH- INS MUST BE
<br />COMPLETED, INSPECTED AND APRROVED
<br />BEFORE REQUESTING THE FRAMING
<br />INSPECTIONS.
<br />THIS DRAWING AND DESIGN IS VALID
<br />FOR 12 MONTH AFTER THE DATE IT IS
<br />SIGNED AND SEALED.
<br />SIGNED AND SEALED FOR THE
<br />STRUCTURAL PORTION OF THIS
<br />DRAWING ONLY.
<br />Q �j
<br />N
<br />�
<br />N
<br />O
<br />N�
<br />M
<br />a
<br />�
<br />k
<br />M
<br />O
<br />�Ln
<br />N
<br />O
<br />CIO)
<br />�
<br />Rt
<br />N
<br />M
<br />N
<br />CN
<br />N
<br />�
<br />�
<br />00
<br />i-�
<br />U
<br />r'TU
<br />�
<br />O
<br />ro
<br />v
<br />00
<br />O
<br />.-.
<br />0�
<br />CN
<br />.�
<br />�
<br />M
<br />o
<br />W
<br />c°
<br />v
<br />�
<br />U
<br />o,
<br />M
<br />M
<br />H
<br />w
<br />�
<br />z
<br />en
<br />00
<br />Q
<br />SHEET
<br />s of s AS
<br />ELECTRICAL
<br />PLAN
<br />
|