Laserfiche WebLink
NAILING SCHEDULE <br />TABLE 2304.9.1 <br />FASTENING SCHEDULE <br />CONNECTION <br />FASTENING" <br />LOCATION <br />- <br />1. Joist to sill or girder <br />3 - 8d common <br />-3-3 " x 0.131" nails <br />toenail <br />3 - 3" 14 gage staples <br />2. Bridging to joist <br />2 - 8d common <br />2 . 3" v 0,1.31" nails <br />toenail each end <br />2 - 3"14 -age staples <br />3. 1" x 6" subfloor or less to each joist <br />2.8d common <br />face nail <br />4. Wider than I" x 6" subfloor to each joist <br />3 - 8d common <br />face nail <br />5. 2" subfloor to joist or girder <br />2 - l6d common <br />blind and face nail <br />6. Sole plate to joist or blocking <br />16d at I6" o.c. <br />3' x 0.131"nails at 8' o.c. <br />typical face nail <br />3" 14 gage staples at 12" o.c. <br />Sole plate to joist or blocking at hraced <br />3 - 16d at 16' <br />wall panel <br />4 - 3" x 0.131" nails at 16" <br />braced wall panels <br />4 - 3" 14 gage staples per 16" <br />7. Top plate to stud <br />2 - 16d common <br />3 - 3" x 0.131"nails <br />end nail <br />3 - 3" 14 gage staples <br />8. Stud to sole plate <br />4 - 8d common <br />toenail <br />4 - 3" x 0.131" nails <br />3 - 3" 14 gage staples <br />2 - I6d common <br />3- 3" x 0.131" nails <br />end nail <br />3 - 3" 14 gage staples <br />9. Double studs <br />16d at 24" o.c. <br />3" x 0.131" nail at 8" o.c. <br />face nail <br />3" 14 gage staple at 8" o.c. <br />10. Double top plates <br />16d at IC o.c. <br />3" x 0.131"nail at 12" o.c. <br />typical face nail <br />3" 14 gage staple at 12' ox, <br />Double top plates <br />8.164 common <br />12 - 3" x 0.131" nails <br />lap splice <br />12 - 3" 14 a e staples tical face nail <br />11. Blocking between joists or rafters to top plate <br />3 - 8d common <br />3 - 3" x C.131"nails <br />toenail <br />3 - 3" 14 gage staples <br />12. Rim joist to top plate <br />8d at 6" (152 mm) o.c. <br />3" x 0.131" nail at 6" o.c. <br />toenail <br />3" 14 gage staple at 6" o.c. <br />13. Top plates, laps and intersectinnt <br />2 - 16d common <br />3 - 3" x C.131" nails <br />face nail <br />3 - 3" 14 gage staples <br />14. Continuous header, two pieces <br />16d common <br />16' o.c. along edge <br />15. Ceiling joists to plate <br />3 - 8d common <br />5 - 3" x 0.131" nails toenail <br />5 - 3" 14 gage staples <br />16. Continuuus header to stud <br />4 - 8d common toenail <br />CONNECTION <br />FASTENING',' <br />LOCATION <br />l7. Ceiling joists, laps over partitions <br />3 - 16d common minimum. Table 2308.10.4.1 <br />(see Section 2308.10.4 1, Table 2308.10.4.1) <br />4 - 3" x 0.131" nails <br />face nail <br />4 - 3" 14 gage staples <br />18. Ceiling joists to parallel rafters <br />3 - 16d common minimum. Table 2308.10.4.1 <br />(see Section 2308.10.4.1. Table 2308. 10.4. 1) <br />4 - 3" x 0.131"nails <br />face nail <br />4 - 3" 14 gage staffs <br />19. Rafter to plate <br />3 - 8d common <br />(see Section 2308.10.1, Table 2308.10.1) <br />3 - 3" x 0.131" nails <br />toenail <br />3 - 3" 14 gage staples <br />20. 1" diagonal brace to each stud and plate <br />2 - 8d common <br />2.3" x 0.131" nails <br />face nail <br />2 - 3" 14 gage staples face nail <br />21. 1" x 8" sheathing to each bearing wall <br />2 - 8d common <br />face nail <br />22. Wider than 1 "x 8" sheathing to each bearing <br />3 - 8d common <br />face nail <br />23. Built-up corner studs <br />16d common <br />24" o.c. <br />3" x 0.131- nails <br />16" o.c. <br />3" 14 gage staples <br />16' o.c. <br />24. Built-up girder and beams <br />20d common 32" o.e, <br />face nail top and bottom staggered <br />3" x 0.131" nail at 24' o.c. <br />it <br />on opposite sides <br />3" 14 gage staple at 2e o.c. <br />2 - 20d ccmmxm <br />3-3" x 0 131" nails <br />face nail at ends and at each splice <br />3 - 3" 14 ape. staples <br />25. 2 LlaAs <br />16d common <br />at each bearing <br />26. Collar tie to rafter <br />3 - I Od common <br />4 - 3" x 0 131" nails <br />face nail <br />4 - 3" 14 gage staples face nail <br />27. Jack rafter to hip <br />3 - 10d common <br />4 - 3" x 0 13l "nails <br />toenail <br />4 - 3" 14 gage staples <br />2 - 16d common <br />3 - 3" x 0 131" nails <br />face nail <br />3 - 3" 14 gage staples <br />28. Roof ratter to 2-by ridge beam <br />2 - l6d cannon <br />3 - 3" x 0.131" nails <br />toenail <br />3 - 3" 14 gage staples <br />2 - I (A common <br />3-3" x 0,131" nails <br />face nail <br />3 - 3" 14 age staples <br />29. Joist to band joist <br />3 . 16d common <br />5 - 3" x 0.131" nails <br />face nail <br />5 - 3' 14 gage sta les <br />COMMERICAL PROJECT DESCRIPTION <br />CODES IN EFFECT FOR THIS RENOVATION TO AN EXISTING BUILDING: <br />2017 FLORIDA FIRE PREVENTION CODE, GT" EDITION <br />2017 FLORIDA BUILDING CODE, 6"' EDITION <br />2017 FLORIDA MECHANICAL CODE <br />2017 FLORIDA PLUMBING CODE <br />2017 FLORIDA ENERGY CODE <br />2017 FLORIDA ACCESSIBILITY CODE <br />2014 NATIONAL ELECTRICAL CODE <br />ADDRESS: <br />WIND BORNE DEBRIS AREA: This property IS LOCATED outside the 140 mph wind borne debris <br />area. <br />ASCE 7-10 WINDSPEED RISK CATEGORY II: 138 mph as interpolated by the ATC Council. <br />OCCUPANCY: RESIDENTIAL, GROUP R-2 (4 apartments within a former two story masonry <br />church facility) <br />TYPE OF CONSTRUCTION: Type III-B, Unsprinklered Construction <br />LEVEL OF RENOVATION WORK CLASSIFICATION: New Construction <br />ALLOWABLE AREA: Unlimited <br />ACTUAL AREA, each floor: 1,600 S.F. <br />ALLOWABLE HEIGHT: 4 stories <br />ACTUAL HEIGHT: Two stories, approximately 22" front tower height <br />TENANT OCCUPANT LOAD: Residential - 200 SF/gross : 32' x 50' each floor: <br />1,600 SF x2 firs = 3,200 SF total/200 SF = 16 persons <br />MAXIMUM TRAVEL DISTANCE WITHOUT SPRINKLERS, Table 1016.2: 200' <br />Table 1015.1 Spaces with one exit or exit access doorway, R2 occupancy: 49 persons maximum. <br />TERMITE PROTECTION <br />FOUNDATION INSPECTION REQUIRED: A foundation survey shall be performed & a copy of the survey <br />shall be on the site for the building inspector's use, or all property markers shall be exposed & a string <br />stretched from marker to marker to verify required setbacks. <br />FRAMING INSPECTION: All plumbing, electrical, and mechanical rough -ins must be complete, inspected <br />and approved before requesting the framing inspection. <br />FLORIDA BUILDING CODE 2017, 6" Edition <br />TERMITE TREATMENT PROTECTION SECTIONS: <br />105.1 1: Notice of termite protection note. <br />1503.7: Condensate & roof downspouts discharge note. <br />2304.1 1: Protection against decay & termites. Adhere to all applicable sub -sections within <br />this section as a part of this project. <br />2304.13: Preparation of building site & removal of debris note. <br />All of the above Florida Building Code sections are to be implemented for this project. <br />STRUCTURAL DESIGN & MATERIALS CRITERIA <br />1 . Basic Wind Speed: 138 mph <br />2. Wind Importance Factor: 2 <br />3. Building Exposure Category- B <br />4. Wind Exposure- 1 <br />S. Applicable internal pressure coefficient: +-.18 psf <br />6. Components & Cladding wind design pressure: 10 psf <br />This building is designed in accordance & compliance with the current edition of the Florida Building <br />Code 2017, 61" Edition, including Section 1609.3 Wind Loads Design Criteria; American Society of Civil <br />Engineers Standard 7-93, Minimum Design Loads for Buildings & Other Structures. Residential projects <br />are designed in accordance with the Florida Residential Building Code 2017, 6"' Edition. <br />DESIGN LOADS: Roof Live Loads: 20 roof <br />Wind Speed: 138 mph as interpolated by the Applied Technology <br />Council <br />Warning: The structural integrity of the building shown on these drawings is dependent on completion <br />according to these documents. Structural members are not self-supporting. and during construction <br />require temporary bracing until permanently affixed to the structure as directed/designed. All <br />structures are designed as stable & permanent units after all components are in place. All persons <br />responsible for the erection of these structures shall provide all necessary shoring & bracing to insure <br />stability & safety during construction. The Architect assumes no liability for the failure of others to <br />provide the necessary shoring & bracing. <br />SITE WORK: <br />See civil drawings <br />CONCRETE: <br />See civil drawings for new sidewalks <br />MASONRY: <br />l . No masonry work will be required as a part of this project <br />WOOD: <br />1 . Follow all requirements of the current edition of the Florida Building Code 2017, 61" Edition, for <br />all wood framing including, but not limited to, connections, bracing, nailing & bridging. Follow all <br />guidelines contained in the Southern Pine Joist & Rafter Construction Guide. <br />2. All wall stud & miscellaneous rough framing lumber 2x4" or larger as shown on the dwgs shall be <br />grade -stamped Southern Pine No 2 KD or better. Sizes indicated are nominal mill size, unless <br />noted otherwise. <br />3. Minimum allowable stresses: Fb: 1,250 psi; E: 1,600,000 psi; Fv: 10S ps <br />4. Unless otherwise noted, all framing connectors & fasteners are SIMPSON products & components. <br />FLORIDA PRODUCT APPROVAL <br />ANDERSEN lee SERIES CASEMENT WINDOWS, ALUMINUM, FL-15'be&ll -R4, <br />121ero12017 <br />ALL WORK SHALL COMPLY WITH <br />NFFA CODES AND STANDARDS <br />REVIEW DA I a <br />CITY OF ZE ILL `� <br />FIRE AND LIFE SAFELY � R`__ <br />M E <br />INDEX OF DRAWINGS <br />40 00 M <br />C5 PROJECT INFORMATION, CODE AND EXISTING SITE LOCATION c0 E <br />Mr.-. <br />Al EXISTING FLOOR PLANS V 0 <br />A2 EXISTING EXTERIOR ELEVATIONS / PROPOSED MODIFICATIONS <br />A3 FROP05ED FLOOR PLANS a� <br />A4 TYPICAL PARTITION 5ECTION5 +� <br />El ELECTRICAL PLAN <br />E <br />s <br />P1 PLUMBING PLAN �■I■� M/ <br />V co E <br />M O <br />H1 HVAC SCHEDULES 0 tf <br />H2 HVAC FIRST FLOOR PLAN W o <br />H3 HVAC SECOND FLOOR PLAN Q <br />H4 HVAC TABULATION PLAN <br />V <br />A <br />APPROXIMATE AREAS : (J? <br />APT. 1: 141 S.F. lam, <br />APT. 2: 143 5. F. <br />APT. 3: -141 S.F. <br />APT. 4: 74e S.F. ° <br />WEST ENTRY: 91 S.F. <br />TOTAL BLDG.: 3,ero& S.F. <br />PROPOSED SITE PLAN WAS PRODUCED BY <br />OTHERS AND APPROVED 5Y THE CITY OF <br />ZEPHYRHILL5 <br />PROJECT LOCATION: NORTH WEST <br />CORNER OF 9TH AVENUE AND 11 TH <br />STREET <br />r <br />PROJECT LOCATION <br />WITH Pa�VAILINO <br />ALL W OP'Y' ALL COM Y BUILDING 20Zo <br />CODES FLORy ELECTRIC CODECODE, MAC 2 9 <br />NATIONAL ELE T C CODZF-PHY' ILLS <br />A1141) -THE CITY ORDINANCES REV1Ew ZE �YFtHI <br />G� E <br />PLN <br />Xp�Il1N�� <br />le•rrt `����' <br />COVER SHEET <br />LtA <br />yV <br />4-2-A <br />un4-10 <br />Z U) W �t <br />Z <br />m � <br />=W W O <br />Z) X <br />2 <br />U Q <br />WJ <br />ofQ I- 0 <br />0 W UJ EE <br />ILL W w ° <br />ow w LL <br />LLI <br />U) J_ <br />W Q 1--fY <br />}_ <br />OLL <br />� O N <br />/o 3_ <br />U ? to N <br />II1111111� <br />CS <br />W-.\BT-19 16 SOUTHERN SKIES APARTMENT HOUSE\CAD FILES\BT 19 16 PLAN SET.dwg, COVER SHEET, 10/29/2019 9:54:37 AM, <br />Bill <br />