Laserfiche WebLink
CLEANOUT AND ACCESS <br />COVER. TOP OF COVER <br />TO BE FLUSH W/TOP OF <br />FLOOR FLOOR LINE <br />1 /8" C.I. BEND — <br />BALANCE OF PIPING <br />SAME AS CLEANOUT <br />TO GRADE <br />FLOOR CLEANOUT (FCO) <br />CLEANOUT NOT TO BE LOCATED <br />IN CARPETED AREA <br />BRASS CLEANOUT PLUG <br />W/COUNTERSUNK HEAD <br />r FINISHED GRADE <br />""-16" SQUARE CONCRETE PAD <br />TROWEL SMOOTH AND EDGE <br />1 /8" C.I. BEND <br />C.I. WASTE LINE <br />LENGTH TO SUIT <br />'* - WASTE LINE <br />1 /8" BEND IF CLEANOUT <br />OCCURS AT END OF LINE <br />CLEANOUT TO GRADE (COTG) <br />CLEANOUT DETAIL <br />NO SCALE <br />MAY EXTEND AS <br />WASTE OR VENT <br />WALL <br />WALLCOVERfr L; PLUGGED TEE <br />AND SCREW WITH CLEANOUT <br />FLOOR LINE <br />1 /8 C.I. BEND <br />BALANCE OF PIPING SAME <br />AS FLOOR CLEANOUT <br />WALL CLEANOUT DETAIL <br />NO SCALE <br />ROOF DECK L•: Im : <br />COPPER OR LEAD SLEEVE <br />WITH FLANGE <br />VENT PIPE <br />ROOF MASTIC <br />:1 ROOF DECK <br />PACK W/OAKUM OR EQUAL <br />MATERIAL TO PREVENT <br />ASPHALT DRAINAGE <br />VENT THRU ROOF DETAIL <br />NO SCALE <br />WALL MOUNTED WATER HEATER <br />0 <br />CONTROLLER. LOCATE ON WALL NEAR <br />WATER HEATER. PROVIDE ALL CONTROL <br />WIRING PER MANUFACTURER'S <br />RECOMMENDATIONS. (TYP) <br />— <br />ASME RATED TEMPERATURE AND <br />PRESSURE RELIEF VALVE. <br />EXTEND FULL-SIZED DISCHARGE <br />TO SPILL OVER DRAIN (TYP) <br />INSTANTANEOUS <br />TANKLESS <br />WATER HEATER <br />0 1 o <br />CONCENTRIC VENT (TYP) <br />SECURE TO WALL PER <br />MANUFACTURER'S <br />RECOMMENDATIONS <br />f 1 j m Li EXPANSION <br />[ 1 ] 1 1 TANK <br />- — ------ <br />WATER HEATER DETAIL <br />NO SCALE <br />• ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2017 FLORIDA PLUMBING <br />CODE (6TH EDITION). <br />• REVIEW PLANS OF ALL TRADES PRIOR TO BIDDING AND INSTALLATION TO INCLUDE <br />ALL PLUMBING FOR COMPLETE SYSTEMS SHOWN ON THE PLANS AND AS REQUIRED. <br />• COORDINATE WITH OTHER TRADES TO PREVENT INTERFERENCE WITH HVAC DUCTS, <br />STRUCTURE, ELECTRICAL LIGHTING, AND OTHER PIPING IN THE CEILING SPACE. <br />VENT PIPING AND WATER PIPING SHALL BE HELD EITHER ABOVE OR BELOW HVAC <br />DUCTWORK AS COORDINATED WITH THE HVAC CONTRACTOR. <br />• ALL CHANGES SHALL BE APPROVED BY THE ARCHITECT/OWNER. <br />• COORDINATE WITH ARCHITECTURAL DRAWINGS BEFORE ROUGHING -IN PLUMBING <br />FIXTURES AND EQUIPMENT SUPPLIES. <br />• THE PLUMBING SUBCONTRACTOR SHALL FURNISH AND INSTALL ALL PLUMBING <br />FIXTURES, AS IDENTIFIED ON PLUMBING FIXTURE SCHEDULE. <br />• VERIFY MOUNTING HEIGHT AND WATER CONNECTION SIZES TO ALL PLUMBING <br />FIXTURES PRIOR TO ROUGH -IN. FURNISH CUT-OUT TEMPLATES, FOR PLUMBING <br />FIXTURES TO BE INSTALLED IN MILLWORK, TO THE GENERAL CONTRACTOR. <br />• MAKE PROPER HOT AND COLD WATER, WASTE AND VENT PIPING CONNECTIONS TO <br />ALL FIXTURES AND EQUIPMENT EVEN THOUGH ALL FITTINGS AND CONNECTIONS <br />ARE NOT SHOWN. <br />• VERIFY LOCATION OF EXISTING WATER SERVICE AND THE LOCATION/INVERTS OF <br />SANITARY PIPING PRIOR TO INSTALLATION. <br />• ALL PLUMBING VENTS IN EXTERIOR WALLS SHALL BE OFF -SET A MINIMUM OF <br />3'-0" BEFORE ROOF PENETRATION. <br />• INSTALL WATER HAMMER ARRESTERS WHERE WATER PRESSURES ARE EXCESSIVE <br />OR WHERE REQUIRED TO ELIMINATE WATER HAMMER OR WHEN DEEMED <br />NECESSARY BY LOCAL AUTHORITIES. LOCATE AND SIZE AS RECOMMENDED BY THE <br />AMERICAN SOCIETY OF PLUMBING ENGINEERS. <br />• IT IS IN THE INTENT OF THESE DRAWINGS TO COVER ALL WORK AND MATERIAL FOR <br />A FIRST CLASS INSTALLATION. ANY EQUIPMENT, PLUMBING FIXTURE, TRIM <br />HARDWARE AND/OR DEVICES USUALLY UTILIZED IN THE CLASS OF WORK, THOUGH <br />NOT SPECIFICALLY MENTIONED OR SHOWN ON THESE DRAWINGS, BUT WHICH MAY BE <br />NECESSARY FOR THE SATISFACTORY COMPLETION OF THE WORK (AS DETERMINED <br />BY THE ARCHITECT) SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR AS <br />PART OF HIS TOTAL WORK. <br />• ALL WORK, BOTH MATERIAL AND INSTALLATION, SHALL BE GUARANTEED FOR A <br />PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE BY THE OWNER. <br />• CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ENGINEER REVIEW. <br />WC-1: WATER CLOSET - AMERICAN STANDARD 2876.016.020, WHITE, YORKVILLE 1.6 GPF <br />BACK OUTLET TOILET. <br />WC-2: WATER CLOSET - ADA - PROFLO NO. PF143T LOW CONSUMPTION, TWO PIECE, <br />VITREOUS CHINA, GRAVITY FED, ENLONGATED. 1.1-1.6 GPF. BOTTOM OUTLET TOILET. <br />LAV-1: LAVATORY - PROVIDE CONSTRUCTOR CENTERSET 2-HANDLE BATHROOM FAUCET <br />IN CHROME, MODEL # F512105CP. VANITY CABINET PROVIDED BY OWNER. <br />KS-1: KITCHEN SINK - PROFLO PFUC308A STAINLESS STEEL, UNDERMOUNT. PROVIDE <br />MOEN NO. 7423 SINGLE HANDLE FAUCET. 1.5 GPM. PROVIDE STOPS, SUPPLIES <br />AND TRAP TO MAKE A COMPLETE INSTALLATION. <br />SH-1: SHOWER, ADA - MOEN TL182EP. SINGLE FUNCTION SHOWER HEAD. 1.75 GPM. <br />WHITE PREFABRICATED SHOWER PROVIDED BY OWNER. <br />BT-1: TUB, ADA - MOEN 82537. INCLUDES VALVE, TUB SPOUT, SHOWER HEAD. 1.75 GPM. <br />SINGLE LEVER HANDLE. BATHTUB PROVIDED BY OWNER. <br />WB-1: WASHER BOX - IPS WATER TITE WASHER BOX NO. W4700 (82064). PROVIDE <br />WASH MACHINE DRAIN PAN WITH 2" LIP, SIZED TO WASHER. CONNECT DRAIN TO <br />2" DRAIN PIPE IN WALL. <br />LS-1: LIFT STATION - 500 GALLON DUPLEX FIBERGLASS PUMP STATION MATH (2) 1.0 HP <br />SEWAGE EJECTOR PUMPS AND ALTERNATING DUPLEX CONTROL PANEL #5OA506. <br />ITEM #: 500FPT-10SDUP, MANUFACTURER: SEPTIC SOLUTIONS. 170 GPM 015FT OF <br />HEAD, SHUT OFF: 48FT OF HEAD. 230VAC, 13.3A, 60 HZ, 1 PHASE. SPI SDC12B <br />DUPLEX CONTROL PANEL WITH ALARM. CONTACT (877)-925-5132. <br />HB-1: HOSE BIB, MILD CLIMATE - EVERBILT - 1/2 IN. BRASS 1/4 TURN MPT X MHT <br />HOSE BIB. 3/4 IN. HOSE THREAD OUTLET. MODEL #VHBQTCC3EB. PROVIDE <br />VACUUM BREAKER. <br />GD-1: GARBAGE DISPOSER, CORDED - GE APPLIANCES NO. GFC525V, 1 /2 HP, WALL <br />SWITCH WITH SINK STOPPER. <br />FCO: FLOOR CLEAN OUT - ZURN NO. Z-1444, POLISHED BRONZE ACCESS COVER, <br />DURA COATED CAST IRON BODY. MATCH TO PIPE SIZE. <br />WCO: WALL CLEAN -OUT - ZURN, #Z-1441, SMOOTH STAINLESS STEEL ACCESS <br />COVER, DURA-COATED CAST IRON BODY. MATCH TO PIPE SIZE. <br />SA: SHOCK ABSORBER- SHALL BE J.R.SMITH 5005 THRU 5050 AND SIZED AS <br />RECOMMENDED BY MANUFACTURER. <br />WH-1: WATER HEATER - RHEEM - ELECTRIC - TANKLESS, MODEL RTEX-13, 54 AMP, <br />24OV, 1 PH, 60 HZ, 13 KW, WALL MOUNTED. 1/2" INLET/OUTLET WHOLE HOUSE. <br />� T iirrr <br />t•tE �,'"'0r <br />a� <br />I �411111 ilk <br />Roma EnterpdseA kic. <br />P.E. # 56067 Ronald R. Renna, P.E. <br />au7H. # 00008631 Consulting Engineers <br />3231 Drone Field Road Ph. (863) 646 1258 <br />Lakeland, FI 33811 Fox.(863) 646 8881 <br />tJ1 <br />°' <br />� <br />U <br />N <br />� <br />o <br />N <br />0 <br />V <br />00�� <br />a) <br />, <br />a) <br />0 <br />s <br />cu <br />c>s <br />m0 <br />rn <br />o <br />� <br />W <br />o <br />-0 <br />u <br />z <br />m <br />=WWO <br />Z) cr <br />U Q <br />W —j <br />Q <br />ir F_ 0 <br />o W W Of <br />LL0 W X w° <br />LL <br />w W <br />o� Ix c/) J <br />U) _ _ <br />W LL Q <br />0OON <br />U Z tA < � N <br />01 NOV 2019 <br />P2 <br />