CLEANOUT AND ACCESS
<br />COVER. TOP OF COVER
<br />TO BE FLUSH W/TOP OF
<br />FLOOR FLOOR LINE
<br />1 /8" C.I. BEND —
<br />BALANCE OF PIPING
<br />SAME AS CLEANOUT
<br />TO GRADE
<br />FLOOR CLEANOUT (FCO)
<br />CLEANOUT NOT TO BE LOCATED
<br />IN CARPETED AREA
<br />BRASS CLEANOUT PLUG
<br />W/COUNTERSUNK HEAD
<br />r FINISHED GRADE
<br />""-16" SQUARE CONCRETE PAD
<br />TROWEL SMOOTH AND EDGE
<br />1 /8" C.I. BEND
<br />C.I. WASTE LINE
<br />LENGTH TO SUIT
<br />'* - WASTE LINE
<br />1 /8" BEND IF CLEANOUT
<br />OCCURS AT END OF LINE
<br />CLEANOUT TO GRADE (COTG)
<br />CLEANOUT DETAIL
<br />NO SCALE
<br />MAY EXTEND AS
<br />WASTE OR VENT
<br />WALL
<br />WALLCOVERfr L; PLUGGED TEE
<br />AND SCREW WITH CLEANOUT
<br />FLOOR LINE
<br />1 /8 C.I. BEND
<br />BALANCE OF PIPING SAME
<br />AS FLOOR CLEANOUT
<br />WALL CLEANOUT DETAIL
<br />NO SCALE
<br />ROOF DECK L•: Im :
<br />COPPER OR LEAD SLEEVE
<br />WITH FLANGE
<br />VENT PIPE
<br />ROOF MASTIC
<br />:1 ROOF DECK
<br />PACK W/OAKUM OR EQUAL
<br />MATERIAL TO PREVENT
<br />ASPHALT DRAINAGE
<br />VENT THRU ROOF DETAIL
<br />NO SCALE
<br />WALL MOUNTED WATER HEATER
<br />0
<br />CONTROLLER. LOCATE ON WALL NEAR
<br />WATER HEATER. PROVIDE ALL CONTROL
<br />WIRING PER MANUFACTURER'S
<br />RECOMMENDATIONS. (TYP)
<br />—
<br />ASME RATED TEMPERATURE AND
<br />PRESSURE RELIEF VALVE.
<br />EXTEND FULL-SIZED DISCHARGE
<br />TO SPILL OVER DRAIN (TYP)
<br />INSTANTANEOUS
<br />TANKLESS
<br />WATER HEATER
<br />0 1 o
<br />CONCENTRIC VENT (TYP)
<br />SECURE TO WALL PER
<br />MANUFACTURER'S
<br />RECOMMENDATIONS
<br />f 1 j m Li EXPANSION
<br />[ 1 ] 1 1 TANK
<br />- — ------
<br />WATER HEATER DETAIL
<br />NO SCALE
<br />• ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2017 FLORIDA PLUMBING
<br />CODE (6TH EDITION).
<br />• REVIEW PLANS OF ALL TRADES PRIOR TO BIDDING AND INSTALLATION TO INCLUDE
<br />ALL PLUMBING FOR COMPLETE SYSTEMS SHOWN ON THE PLANS AND AS REQUIRED.
<br />• COORDINATE WITH OTHER TRADES TO PREVENT INTERFERENCE WITH HVAC DUCTS,
<br />STRUCTURE, ELECTRICAL LIGHTING, AND OTHER PIPING IN THE CEILING SPACE.
<br />VENT PIPING AND WATER PIPING SHALL BE HELD EITHER ABOVE OR BELOW HVAC
<br />DUCTWORK AS COORDINATED WITH THE HVAC CONTRACTOR.
<br />• ALL CHANGES SHALL BE APPROVED BY THE ARCHITECT/OWNER.
<br />• COORDINATE WITH ARCHITECTURAL DRAWINGS BEFORE ROUGHING -IN PLUMBING
<br />FIXTURES AND EQUIPMENT SUPPLIES.
<br />• THE PLUMBING SUBCONTRACTOR SHALL FURNISH AND INSTALL ALL PLUMBING
<br />FIXTURES, AS IDENTIFIED ON PLUMBING FIXTURE SCHEDULE.
<br />• VERIFY MOUNTING HEIGHT AND WATER CONNECTION SIZES TO ALL PLUMBING
<br />FIXTURES PRIOR TO ROUGH -IN. FURNISH CUT-OUT TEMPLATES, FOR PLUMBING
<br />FIXTURES TO BE INSTALLED IN MILLWORK, TO THE GENERAL CONTRACTOR.
<br />• MAKE PROPER HOT AND COLD WATER, WASTE AND VENT PIPING CONNECTIONS TO
<br />ALL FIXTURES AND EQUIPMENT EVEN THOUGH ALL FITTINGS AND CONNECTIONS
<br />ARE NOT SHOWN.
<br />• VERIFY LOCATION OF EXISTING WATER SERVICE AND THE LOCATION/INVERTS OF
<br />SANITARY PIPING PRIOR TO INSTALLATION.
<br />• ALL PLUMBING VENTS IN EXTERIOR WALLS SHALL BE OFF -SET A MINIMUM OF
<br />3'-0" BEFORE ROOF PENETRATION.
<br />• INSTALL WATER HAMMER ARRESTERS WHERE WATER PRESSURES ARE EXCESSIVE
<br />OR WHERE REQUIRED TO ELIMINATE WATER HAMMER OR WHEN DEEMED
<br />NECESSARY BY LOCAL AUTHORITIES. LOCATE AND SIZE AS RECOMMENDED BY THE
<br />AMERICAN SOCIETY OF PLUMBING ENGINEERS.
<br />• IT IS IN THE INTENT OF THESE DRAWINGS TO COVER ALL WORK AND MATERIAL FOR
<br />A FIRST CLASS INSTALLATION. ANY EQUIPMENT, PLUMBING FIXTURE, TRIM
<br />HARDWARE AND/OR DEVICES USUALLY UTILIZED IN THE CLASS OF WORK, THOUGH
<br />NOT SPECIFICALLY MENTIONED OR SHOWN ON THESE DRAWINGS, BUT WHICH MAY BE
<br />NECESSARY FOR THE SATISFACTORY COMPLETION OF THE WORK (AS DETERMINED
<br />BY THE ARCHITECT) SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR AS
<br />PART OF HIS TOTAL WORK.
<br />• ALL WORK, BOTH MATERIAL AND INSTALLATION, SHALL BE GUARANTEED FOR A
<br />PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE BY THE OWNER.
<br />• CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ENGINEER REVIEW.
<br />WC-1: WATER CLOSET - AMERICAN STANDARD 2876.016.020, WHITE, YORKVILLE 1.6 GPF
<br />BACK OUTLET TOILET.
<br />WC-2: WATER CLOSET - ADA - PROFLO NO. PF143T LOW CONSUMPTION, TWO PIECE,
<br />VITREOUS CHINA, GRAVITY FED, ENLONGATED. 1.1-1.6 GPF. BOTTOM OUTLET TOILET.
<br />LAV-1: LAVATORY - PROVIDE CONSTRUCTOR CENTERSET 2-HANDLE BATHROOM FAUCET
<br />IN CHROME, MODEL # F512105CP. VANITY CABINET PROVIDED BY OWNER.
<br />KS-1: KITCHEN SINK - PROFLO PFUC308A STAINLESS STEEL, UNDERMOUNT. PROVIDE
<br />MOEN NO. 7423 SINGLE HANDLE FAUCET. 1.5 GPM. PROVIDE STOPS, SUPPLIES
<br />AND TRAP TO MAKE A COMPLETE INSTALLATION.
<br />SH-1: SHOWER, ADA - MOEN TL182EP. SINGLE FUNCTION SHOWER HEAD. 1.75 GPM.
<br />WHITE PREFABRICATED SHOWER PROVIDED BY OWNER.
<br />BT-1: TUB, ADA - MOEN 82537. INCLUDES VALVE, TUB SPOUT, SHOWER HEAD. 1.75 GPM.
<br />SINGLE LEVER HANDLE. BATHTUB PROVIDED BY OWNER.
<br />WB-1: WASHER BOX - IPS WATER TITE WASHER BOX NO. W4700 (82064). PROVIDE
<br />WASH MACHINE DRAIN PAN WITH 2" LIP, SIZED TO WASHER. CONNECT DRAIN TO
<br />2" DRAIN PIPE IN WALL.
<br />LS-1: LIFT STATION - 500 GALLON DUPLEX FIBERGLASS PUMP STATION MATH (2) 1.0 HP
<br />SEWAGE EJECTOR PUMPS AND ALTERNATING DUPLEX CONTROL PANEL #5OA506.
<br />ITEM #: 500FPT-10SDUP, MANUFACTURER: SEPTIC SOLUTIONS. 170 GPM 015FT OF
<br />HEAD, SHUT OFF: 48FT OF HEAD. 230VAC, 13.3A, 60 HZ, 1 PHASE. SPI SDC12B
<br />DUPLEX CONTROL PANEL WITH ALARM. CONTACT (877)-925-5132.
<br />HB-1: HOSE BIB, MILD CLIMATE - EVERBILT - 1/2 IN. BRASS 1/4 TURN MPT X MHT
<br />HOSE BIB. 3/4 IN. HOSE THREAD OUTLET. MODEL #VHBQTCC3EB. PROVIDE
<br />VACUUM BREAKER.
<br />GD-1: GARBAGE DISPOSER, CORDED - GE APPLIANCES NO. GFC525V, 1 /2 HP, WALL
<br />SWITCH WITH SINK STOPPER.
<br />FCO: FLOOR CLEAN OUT - ZURN NO. Z-1444, POLISHED BRONZE ACCESS COVER,
<br />DURA COATED CAST IRON BODY. MATCH TO PIPE SIZE.
<br />WCO: WALL CLEAN -OUT - ZURN, #Z-1441, SMOOTH STAINLESS STEEL ACCESS
<br />COVER, DURA-COATED CAST IRON BODY. MATCH TO PIPE SIZE.
<br />SA: SHOCK ABSORBER- SHALL BE J.R.SMITH 5005 THRU 5050 AND SIZED AS
<br />RECOMMENDED BY MANUFACTURER.
<br />WH-1: WATER HEATER - RHEEM - ELECTRIC - TANKLESS, MODEL RTEX-13, 54 AMP,
<br />24OV, 1 PH, 60 HZ, 13 KW, WALL MOUNTED. 1/2" INLET/OUTLET WHOLE HOUSE.
<br />� T iirrr
<br />t•tE �,'"'0r
<br />a�
<br />I �411111 ilk
<br />Roma EnterpdseA kic.
<br />P.E. # 56067 Ronald R. Renna, P.E.
<br />au7H. # 00008631 Consulting Engineers
<br />3231 Drone Field Road Ph. (863) 646 1258
<br />Lakeland, FI 33811 Fox.(863) 646 8881
<br />tJ1
<br />°'
<br />�
<br />U
<br />N
<br />�
<br />o
<br />N
<br />0
<br />V
<br />00��
<br />a)
<br />,
<br />a)
<br />0
<br />s
<br />cu
<br />c>s
<br />m0
<br />rn
<br />o
<br />�
<br />W
<br />o
<br />-0
<br />u
<br />z
<br />m
<br />=WWO
<br />Z) cr
<br />U Q
<br />W —j
<br />Q
<br />ir F_ 0
<br />o W W Of
<br />LL0 W X w°
<br />LL
<br />w W
<br />o� Ix c/) J
<br />U) _ _
<br />W LL Q
<br />0OON
<br />U Z tA < � N
<br />01 NOV 2019
<br />P2
<br />
|