My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5919 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
5919 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 12:17:17 PM
Creation date
2/18/2025 3:22:55 PM
Metadata
Fields
Template:
Building Plans
Street #
5919
Location
Gall Blvd
Contractor
Vari Construction
Building Plans - Permit #
21147
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
05 1 NOT USED <br />05 1 NOT USED <br />ROOF GENERAL NOTES <br />A. PAINT ALL NEW AND EXISTING GAS PIPING ON ROOF. <br />B. PROVIDE CRICKETS ON BACKWATER SIDE OF ALL NEW ROOFTOP EQUIPMENT <br />CURBS. <br />C. PATCH ALL RUSTED ROOF DECKING WITH NEW ROOF DECKING TO MATCH <br />EXISTING. PREP DECKING FOR NEW PAINTED FINISH. <br />D. PATCH ALL ABANDONED ROOF DECK OPENINGS (I.E. REMOVED RTU'S, EXHAUST <br />SYSTEMS, ETC.) WITH NEW ROOF DECKING TO MATCH EXISTING. NO ROOF <br />OPENINGS ARE PERMITTED. <br />GENERAL NOTES <br />A. REFER TO ELECTRICAL DRAWINGS FOR LIGHT FIXTURE SCHEDULE. <br />B. REFER TO FINISH SCHEDULE FOR CEILING TYPES. <br />C. ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR ALL LOCAL CODE <br />REQUIREMENTS CONCERNING SEISMIC BRACING AND LATERAL SUPPORT <br />REQUIREMENTS. <br />D. COORDINATE EXIT SIGNS LOCATIONS/HEIGHTS WITH LOCAL FIRE MARSHAL. <br />G.C. TO VERIFY THAT EXIT SIGNS WILL NOT INTERFERE WITH TENANTS <br />INTERIOR GRAPHICS OR LIGHTING. <br />E. G.C. IS RESPONSIBLE FOR STRAIGHTENING/RE-ALIGNING LIGHTING ROWS <br />AFTER FIXTURES INSTALLATION IS COMPLETED. <br />F. ROUTE ALL WATER, GAS, VENT PIPING IN JOIST SPACE OR TO IMMEDIATE <br />UNDERSIDE OF JOIST. MODIFY ANY EXISTING UTILITIES AS REQUIRED.. <br />G. CEILING, LIGHTING, ETC. SUPPORTING SYSTEMS SHALL ATTACH TO <br />STRUCTURAL MEMBERS ONLY, ARE NOT PERMITTED TO BE ATTACHED TO <br />ROOF DECKING, BRIDGING OR WIND BRACING, AND SHALL COMPLY WITH <br />SEISMIC ZONING BRACING REQUIREMENTS. DESIGN OF THE SUPPORTING <br />SYSTEM IS TO FOLLOW THE MANUFACTURERS INSTALLATION REQUIREMENTS <br />AND IS THE CONTRACTORS RESPONSIBILITY. <br />H. ANY EXISTING CEILING ITEMS THAT ARE TO REMAIN IN OPERATION (FOR <br />EXAMPLE: EXISTING ROOF DRAINAGE PIPING, EXISTING GENERAL PIPING, <br />EXISTING CONDUITS, EXISTING DUCT WORK OR ANY OTHER EXISTING BUILDING <br />SYSTEM ELEMENTS) ARE TO BE RAISED AS REQUIRED FOR LIGHT FIXTURE <br />INSTALLATION. G.C. TO COORDINATE AS REQUIRED. <br />M/11114 1 CC JrLIIiC <br />4NNEL <br />CODED NOTES <br />1. OPEN TO STRUCTURE ABOVE. PAINT EXPOSED STRUCTURE, CONDUIT, PIPING <br />HANGERS, DUCTWORK, ETC. ACCORDING TO FINISH SCHEDULE. ALL NEW EXPOSED <br />DUCTWORK TO BE PROVIDED WITH PAINT GRIP FINISH. <br />2. OPEN TO STRUCTURE ABOVE. <br />3. GYPSUM BOARD CEILING @ 8'-0" AFF. 5/8" MOISTURE RESISTANT GYPSUM BOARD <br />OVER DRYWALL SUSPENSION SYSTEM - USG OR EQUAL. PAINT ACCORDING TO <br />FINISH SCHEDULE. <br />4. ACOUSTIC TILE CEILING & GRID ACT-1 @ 10'-0" A.F.F. <br />5. EXIT SIGN WITH EXTERIOR REMOTE EMERGENCY HEAD. <br />6. MOISTURE RESISTANT ACOUSTIC TILE CEILING & GRID ACT-2 @ 10'-0" A.F.F. <br />7. LED STRIP LIGHT SUSPENDED AT 1 V-6" A.F.F. USING GRIPPLE LOOP WITH EXPRESS <br />FASTENER CABLE SYSTEM. REFER TO ELECTRICAL DRAWINGS FOR DETAILS. <br />8. LED STRIP LIGHT SUSPENDED AT 13'-0" A.F.F. USING GRIPPLE LOOP WITH EXPRESS <br />FASTENER CABLE SYSTEM WITH WRAP AROUND LENS. REFER TO ELECTRICAL <br />DRAWINGS FOR DETAILS. <br />9. SURFACE MOUNTED LED LIGHT FIXTURE INSTALLED WITH 2" SPACERS AND WRAP <br />AROUND LENS. REFER TO ELECTRICAL DRAWINGS FOR DETAILS. <br />10. SURFACE MOUNTED LED LIGHT FIXTURE INSTALLED WITH 2" SPACERS. REFER TO <br />ELECTRICAL DRAWINGS FOR DETAILS. <br />11. EXHAUST FAN. TYPICAL FOR BOTH RESTROOMS. <br />12. NOT USED. <br />13. APPROXIMATE LOCATION OF EXISTING ROOFTOP UNIT THAT WILL BE REPLACED <br />WITH NEW RTU. REFER TO MECHANICAL DRAWINGS FOR SPECS ON NEW RTU'S. <br />14. NEW DUCTWORK INSTALLED AT MAX. HEIGHT IN SALES AND BACK ROOM. EXPOSED <br />TO VIEW DUCTWORK TO BE FABRICATED WITH PAINT GRIP FINISH. PAINT ALL <br />EXPOSED DUCTWORK INCLUDING SUPPLY AND RETURN DROPS PER THE FINISH <br />SCHEDULE. REFER TO MECHANICAL DRAWINGS FOR DETAILS. NEW DUCTWORK <br />ABOVE LAY -IN CEILING IN ALL ROOMS WITH CEILINGS. COORDINATE DUCTWORK <br />ON SHEET M1.0 WITH LIGHTING PLAN. <br />15. REFER TO GENERAL NOTES REGARDING EXISTING OR NEW SPRINKLER SYSTEM. <br />16. NOT USED. <br />17. 24"X24" ACCESS PANEL TO BE INSTALLED AT EXTERIOR SOFFIT TO GAIN ACCESS <br />TO BUILDING SIGNAGE. COORDINATE WITH LANDLORD FOR EXACT LOCATION. <br />18. NOT USED. <br />19. VANITY LIGHTING REFER TO ELECTRICAL DRAWINGS FOR DETAILS. <br />20. EXISTING LIGHTS UNDER CANOPY TO REMAIN - GC TO CONFIRM ALL ARE IN GOOD <br />CONDITION AND OPERATING. <br />21. APPROXIMATE LOCATION OF NEW ROOFTOP UNIT. REFER TO MECHANICAL <br />DRAWINGS FOR SPECS ON NEW RTU'S. <br />SCALE: N.T.S. <br />04 <br />NOT <br />USED <br />SCALE: N.T.S. <br />03 <br />DRYWALL SUSPENSION SYSTEM CROSS CHANNEL <br />DETAL <br />SCALE: 1" = V-0" <br />BOTTOM OF DUCT <br />=12'-0" (+-) <br />BOTTOM OF SPRINKLER =N/A <br />:. ;.� .. <br />�:''"•�"' ------------------------------ <br />� <br />BOTTOM OF LIGHTS <br />IN SALES AREA <br />=11'-6" <br />= �•.! y' cl� <br />--WOOD RAMP <br />j 5 —� I <br />14 2 o <br />49i <br />M <br />0 <br />I- <br />4 OFFICE <br />BACK ROOM r - -j 10 <br />INEW I SALES <br />RTU _ 4 7 iv <br />LtATIO <br />SCALE: N.T.S. I 3 11. 1 <br />15 <br />_yw1gl5 . <br />EQ. 6'-0" EQ. - _ - <br />3 11 2;-0„ EQ. EQ. 2,_6„ iv <br />T RT 19 ••� •:• L <br />lhili <br />RTU RTU <br />t1NISEX �OCATIO" I[OCATIO" <br />I6 6 ,3 13 J <br />CROSS CHANNEL ANGLE MOLDING PUBLIC <br />PET <br />WASH <br />O�O <br />I <br />6 9 <br />`J GROOMING <br />W i <br />GYPSUM BOAR SCREW INTO <br />CEILING PANEL MOLDING AT I RH CAT-/ <br />PERIMETER <br />ADOPT <br />I 17 20 <br />I <br />0 <br />I` <br />0 <br />Z <br />O <br />H <br />a <br />U) <br />w <br />0 <br />W <br />Q <br />W <br />Z <br />Q <br />_j <br />0- <br />V <br />Z <br />W <br />U <br />0 <br />W <br />U <br />W <br />J <br />LL <br />W <br />w <br />ISSUED FOR: <br />PERMIT <br />03.14.19 <br />BID <br />03.14.19 <br />CONSTRUCTION <br />00.00.00 <br />REVIEW SET <br />03.14.19 <br />JOB NO. <br />18390 <br />I OZ I DRYWALL SUSPENSION SYSTEM I SCALE:1"=1'-0" 101 I REFLECTED CEILING PLAN I SCALE: 1/8"=V-0" I <br />PERIMETER DETAIL <br />A300 <br />
The URL can be used to link to this page
Your browser does not support the video tag.