My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5919 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
5919 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 12:17:17 PM
Creation date
2/18/2025 3:22:55 PM
Metadata
Fields
Template:
Building Plans
Street #
5919
Location
Gall Blvd
Contractor
Vari Construction
Building Plans - Permit #
21147
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MECHANICAL SYMBOL LEGEND <br />CODED NOTES Q <br />GENERAL NOTES <br />TURNING VANES <br />AIR EXTRACTOR <br />OPPOSED BLADE VOLUME DAMPER <br />SUPPLY DUCT <br />RETURN OR EXHAUST DUCT <br />FLEXIBLE DUCT CONNECTION <br />LINED DUCTWORK <br />DUCT SMOKE DETECTOR TO SHUT <br />- <br />DOWN UNIT UNDER ALARM. <br />I: <br />LOUVERED DOOR (BY G.C.) <br />UCD <br />UNDERCUT DOOR (BY G.C.) <br />® <br />CONNECT TO EXISTING <br />SUPPLY DUCTWORK <br />- — - — - — - — <br />RETURN DUCTWORK <br />- — — — — <br />EXHAUST DUCTWORK <br />SR <br />RG <br />SA <br />RA <br />VD <br />FD <br />GC <br />MC <br />PC <br />EC <br />A.F.F. <br />(EX) <br />N <br />SUPPLY REGISTER <br />RETURN GRILLE <br />SUPPLY AIR <br />RETURN AIR <br />VOLUME DAMPER <br />FIRE DAMER <br />GENERAL CONTRACTOR <br />MECHANICAL CONTRACTOR <br />PLUMBING CONTRACTOR <br />ELECTRICAL CONTRACTOR <br />ABOVE FINSHED FLOOR <br />EXISTING TO REMAIN <br />THERMOSTAT <br />SENSOR <br />SMOKE DETECTOR TEST STATION <br />SMOKE DETECTOR TEST STATION <br />1. MECHANICAL CONTRACTOR TO PROVIDE, INSTALL AND WIRE NEW 7-DAY <br />PROGRAMMABLE THERMOSTAT WITH REMOTE SENSOR FOR EACH HVAC UNIT. <br />SENSOR SHALL BE LOCATED ON COLUMN OR CORNER OF WALL AND THERMOSTAT <br />TO BE LOCATED IN OFFICE. MOUNT TEMPERATURE SENSOR ON COLUMN OR WALL AT <br />8'-0" ABOVE FINISHED FLOOR WITH LOCKED, VENTED, METAL OR PLASTIC <br />ENCLOSURE. MECHANICAL CONTRACTOR SHALL LABEL ALL THERMOSTATS AND <br />SENSOR WITH RESPECTIVE RTU. COORDINATE EXACT LOCATION WITH ARCHITECT <br />AND OWNER PRIOR TO ROUGH —IN. PROVIDE CONTROL WIRING AS REQUIRED. <br />2. FACTORY MOUNTED SMOKE DETECTOR IN RETURN AIR. MECHANICAL CONTRACTOR <br />TO COORDINATE FINAL CONNECTION HVAC UNIT WITH ELECTRICAL CONTRACTOR. <br />WIRING BY ELECTRICAL CONTRACTOR TO SHUT DOWN CORRESPONDING AIR <br />HANDLING UNIT UNDER ALARM CONDITIONS. ALL WIRING SHALL BE IN CONDUIT PER <br />N.E.C. SMOKE DETECTOR SHALL BE COMPATIBLE WITH FIRE ALARM SYSTEM (VERIFY <br />WITH E.C. PRIOR TO ORDERING). <br />3. MECHANICAL CONTRACTOR TO PROVIDE AND MOUNT SMOKE DETECTOR REMOTE <br />KEY STATUS AND TEST STATIONS (WITH AUDIO AND VISUAL ALARM) NEXT TO UNIT <br />THERMOSTAT. M.C. TO LABEL DETECTOR SERVING RESPECTIVE ROOFTOP UNIT. ALL <br />WIRING SHALL BE BY ELECTRICAL CONTRACTOR IN CONDUIT PER N.E.C. REMOTE <br />STATION SHALL BE A SYSTEM SENSOR MODEL SSK451 OR EQUAL. <br />4. ROOF MOUNTED EXHAUST FAN. SEE DETAIL AND SCHEDULE FOR REQUIREMENTS. <br />5. NOT USED. <br />6. UNDERCUT DOOR 3/4" FOR MAKE UP AIR. COORDINATE WITH DOOR SCHEDULE ON <br />SHEET A9.0. <br />7. MANUAL VOLUME CONTROL DAMPERS SHALL BE LOCK —TYPE (TYPICAL FOR ALL). <br />8. EXHAUST FAN LOCATED ON CEILING. SEE ELECTRICAL DRAWINGS FOR EXACT <br />LOCATION. <br />9. 8"0 EXHAUST AIR DUCT UP THRU ROOF. TERMINATE ON ROOF WITH GOOSE NECK <br />AND BIRD SCREEN. <br />10. 26x20 RETURN AIR OPENING ON TOP OF RETURN AIR DUCT. SEE DETAIL ON M2.0 FOR <br />MORE INFO. <br />11. 14x14 RETURN AIR OPENING ON TOP OF RETURN AIR DUCT. SEE DETAIL ON M2.0 FOR <br />MORE INFO. <br />12. NOT USED. <br />13. MOUNT CARBON DIOXIDE SENSOR AT 5'-0" A.F.F. ONE SENSOR SHALL CONTROL <br />OUTDOOR AIR FLOW FROM RTU-1 AND RTU-2. <br />14. NOT USED. <br />15. DUCT MOUNTED EXHAUST GRILLE SHALL BE CENTERED ABOVE SHELVING UNIT FOR <br />FEEDER MICE. <br />16. PROVIDE TRANSFER DUCT THRU WALL FROM RETURN AIR PLENUM. PROVIDE GRILLE <br />ON FINISHED SIDE. TRANSFER GRILLE SHALL BE INSTALLED 13'-0" A.F.F. <br />17. DUCTWORK SHALL BE CENTERED BETWEEN SALES FLOOR LIGHT FIXTURES. <br />18. ROUTE RIGID ALUMINUM DRYER VENT FROM DRYER UP WALL AND TERMINATE THRU <br />ROOF WITH DRYER VENT HOOD. PROVIDE DRYER VENT HOOD WITH BIRD SCREEN AT <br />TERMINATION. MAINTAIN A MINIMUM OF 10'-0" FROM ANY FRESH AIR OPENINGS. <br />19. PROVIDE 2 TRANSFER GRILLES ON PUBLIC PET WASH SIDE OF WALL. MOUNT 1 <br />GRILLE AT 12" AFF, AND 1 AT 13'— 6" AFF W/BLADES POINTED UP. GRILLES ARE TO BE <br />LOCATED IN THE SPACE BETWEEN 2 WALL STUDS, SUCH THAT AIR MAY BE <br />TRANSFERRED BETWEEN THEM. FIELD COORDINATE THE EXACT LOCATION OF THE <br />GRILLES AND ENSURE THAT THERE IS TO BE NO HORIZONTAL FRAMING, OR OTHER <br />OBSTRUCTIONS IN THE STUD SPACE. <br />k <br />k <br />E <br />t <br />1 <br />i <br />i <br />k r---— <br />i i <br />It 7 t � fI <br />n c��l'l t'\'[ 1[1�t/ �. L a\ua qua♦u a..a\yf♦� r\1 C\'{C\ f♦ r'l'C\� 1�\'�'l'�r\S [\�\'\C\'�C'�C Z�\r♦'lC\t\�c\Z'n�♦ZC♦�\'lc♦tC1C\tcA'[�'lc♦�rr\�t1!\'l [1�C�r\'['f1!\'t n'C \'�r\'[t'\c ZC\�\"lC'♦�'C\C\'[l\�\'lC♦`KX'\C\�c�.�\'lC♦T\'1C\'C'C'♦r\"lC'\'C♦1 C�"C C'♦ce^l C\Ct-1 Y\'[\'l C\'l T\ <br />460OFt- <br />600R, <br />D s 00f <br />ea <br />E- <br />Ca 24X12 200 <br />8?i <br />C' �E � <br />RTU-3 , ` F I <br />B 8"0 <br />low <br />200 <br />15 _ <br />�a 8X10 ;E i, ( ,1 I I 3 1 <br />t� 24X12. �E ; -�- I6 <br />8 C 610 <br />i F 8.0 v 1 50 <br />120 "' 18X12 ! I - <br />P'f A I 8"ti Y/— C 6"0 <br />Aa 12 eE <br />D s "t ! 8 ¢ s 3400 s <br />ADJACENT 300 ^i EF-3 _ _ I 6 <br />TENAN 18 4H/ I 6 9 <br />F 6"0 2 <br />"a 16 1 1 X <br />i F 6'0 100 17 RTU-2 17 RTU-1 <br />t: 75 Wl I 1 8.0 0 B 8"0 m co <br />A i i D'cH <br />a B 0" �; �w 12X10 _ 200 0 cn <br />0 <br />OL <br />n i 200 p v BATHIN plv P UA F 8"� 17 <br />Ca hE <br />80r 19 - - 100 <br />F o" 1� yj o I€ I --- 13 10 10 <br />w "0 i I X/ <br />ny $0_= S <br />� <br />i a R TU- <br />- - RTU-2 <br />,10" <br />E <br />1fi 0"0 I 7 l <br />a 1 <br />er U J <br />E E <br />=� -- -- - - - - -- --- - -' _� - _ - _ _-\�\te♦cl r♦trc\ e♦c\1e src♦t r\e♦�e\e ♦�e♦t c\-�e\t \ti c♦ c\c♦-r r♦c \Z c♦e r♦c\-e c�c \�c\c _ - _,. _=�=,= - -c\-♦ <br />_ ` .. E ate... ....�......a.�...a.��.aua.�...a....L...,.a................,.a..,...a...�.i.... E t - <br />' I F O' AC-1 I <br />E E E <br />E I <br />i I i <br />EE I I <br />I <br />E t I <br />_________________________________________L-_}'. 3____________-_______.___________________-______I":c...�1___________________-___________________________l_..-,•1______________-________________________________!:a•.. _____-___-_ .� ____ _____ _ _______________________________________________t_ <br />IE <br />3 E r'--------y 1 <br />-------------------------------------------------------------------------------------------------------!-----------------------------__!_ __ _-------------------- <br />01 1 MECHANICAL PLAN <br />A. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING PROCESS AND BE FAMILIAR <br />WITH THE SCOPE OF WORK. <br />B. MECHANICAL CONTRACTOR SHALL DISCONNECT, DISASSEMBLE, AND REMOVE <br />EXISTING EQUIPMENT, ASSOCIATED DUCTWORK, DIFFUSERS, GRILLES, SUPPORTS, <br />PIPING, AND ASSOCIATED CONTROLS, ETC., NOT OTHERWISE INDICATED TO BE <br />REUSED ON DRAWINGS. ALL OPENINGS IN PIPING AND DUCTS THAT REMAIN SHALL <br />BE PLUGGED/CAPPED AND PROPERLY SECURED. ANY EQUIPMENT DESIGNATED BY <br />OWNER TO BE SALVAGED SHALL BE PROTECTED DURING DEMOLITION AND <br />DELIVERED TO OWNER ON SITE; OTHERWISE, CONTRACTOR SHALL DISPOSE OF <br />LEGALLY AS DIRECTED BY OWNER. <br />C. MECHANICAL CONTRACTOR SHALL TAKE ALL INTERFERENCES INTO <br />CONSIDERATION. PROVIDE ALL NECESSARY OFFSETS OR TRANSITIONS WITH <br />EQUIVALENT AREAS TO MATCH DUCT SIZES AS INDICATED ON DRAWINGS. <br />D. CONTRACTOR SHALL BE FAMILIAR WITH OWNER'S STANDARDS, RULES AND <br />REGULATIONS. ALL OWNER'S CRITERIA SHALL BE COMPLIED WITH AND INCLUDED <br />IN THIS BID. <br />E. ALL DUCTWORK SHALL BE INSTALLED TIGHT TO UNDERSIDE OF STRUCTURE OR AS <br />HIGH AS POSSIBLE ABOVE FINISHED CEILING TO AVOID OBSTRUCTIONS. <br />F. MAINTAIN ALL MANUFACTURER'S RECOMMENDED SERVICE CLEARANCES FOR ALL <br />EQUIPMENT. <br />G. HVAC DUCTWORK SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH <br />ASHRAE AND LATEST SMACNA STANDARDS. PROVIDE TURNING VANES ON ALL <br />ELBOWS. <br />H. ALL SUPPLY AND EXHAUST BRANCH DUCTWORK SHALL HAVE MANUAL VOLUME <br />DAMPERS IN CORRESPONDING RUNOUTS NEAR CONNECTION TO MAIN DUCT. <br />I. NO THERMOSTATS OR SENSOR ARE TO BE LOCATED OVER HEAT PRODUCING <br />EQUIPMENT. <br />J. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, <br />DOCUMENTS AND SERVICES RELATED TO INSTALLATION OF WORK. <br />K. CONDUIT IN EXPOSED TO VIEW AREAS TO BE PAINTED TO MATCH ROOF DECK <br />AND/OR WALL COLOR. <br />L. MECHANICAL CONTRACTOR SHALL PATCH ALL OPENINGS IN EXISTING WALLS, <br />FLOORS, AND CEILINGS REMAINING AFTER COMPLETION OF ALL DEMOLITION <br />WORK FOR PROJECT. CONTRACTOR SHALL PATCH ALL OPENINGS TO MATCH <br />SURROUNDING SURFACE FINISHES. <br />M. FILTERS FOR ALL HVAC UNITS ARE TO BE REPLACED AT THE END OF <br />CONSTRUCTION, CONTRACTOR SHALL SUPPLY (1) ADDITIONAL SET OF FILTERS <br />LABELED FOR THE RESPECTIVE HVAC UNIT TO OWNER AT THE END OF <br />CONSTRUCTION. <br />N. ALL ROOF WORK TO BE DONE BY LANDLORD APPROVED ROOFING CONTRACTOR <br />TO MAINTAIN ROOF WARRANTY. <br />O. ANY EXISTING CEILING ITEMS THAT ARE TO REMAIN (FOR EXAMPLE: EXISTING <br />DUCTWORK OR ANY OTHER EXISTING BUILDING SYSTEM ELEMENTS) ARE TO BE <br />RAISED AS REQUIRED FOR LIGHT FIXTURE INSTALLATION. G.C. TO COORDINATE AS <br />REQUIRED. <br />P. MECHANICAL CONTRACTOR TO PERFORM COMPLETE TEST AND BALANCE OF NEW <br />OR UPDATED HVAC SYSTEM AND SUBMIT TO GC AND BUILDING OFFICIAL IF <br />REQUIRED. <br />Q. COMPLY WITH APPLICABLE REQUIREMENTS OF THE FLORIDA ENERGY CONSERVATION <br />CODE. <br />i � t <br />SCALE: 1/8" = 1'-0" <br />Aoe=lk <br />-AM00,011 <br />ENTECH <br />ENGINEERING INC. <br />5301'ARGINIA WAY SUITE 140 <br />BRENTWOOD, TN 37027 <br />v.615.373.2640 f.615.373.4837 <br />email®entechtn.com entechtn.com <br />Z <br />O <br />H <br />U) <br />W <br />0 <br />W <br />H <br />Q <br />W <br />N <br />LO <br />tM <br />CIO <br />LL <br />5. J_ <br />W� <br />NZ <br />W <br />N <br />U_ <br />Z Z <br />a� <br />U� <br />W <br />2 <br />ISSUED FOR: <br />PERMIT 03.14.19 <br />BID 03.14.19 <br />CONSTRUCTION - <br />REVIEW SET - <br />PROJECT MANAGER DESIGNER <br />JOB NO. <br />18390 <br />mi 00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.