My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5919 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
5919 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 12:17:17 PM
Creation date
2/18/2025 3:22:55 PM
Metadata
Fields
Template:
Building Plans
Street #
5919
Location
Gall Blvd
Contractor
Vari Construction
Building Plans - Permit #
21147
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REDUCED PRESSURE BACKFLOW PREVENTER SCHEDULE <br />DESIGNATION QUANTITY SERVING G.P.M. P.D. (psig) MANUFACTURER MODEL NUMBER REMARKS <br />RPBP-1 1 PSP 27 10 WATTS LF909QT 1Y2" SIZE <br />ENTECH <br />ENGINEERING INC. <br />v '= <br />s <br />ya <br />e- <br />IN <br />NOTE: ALL PIPING TO BE RIGIDLY SUPPORTED. <br />1l/" WATER SERVICE —i <br />SEE SHEEP P1.1 <br />FOR CONT. <br />PRESSURE GAUG <br />(TYP.) <br />FULL LINE SIZE WYE <br />STRAINER WITH l2" <br />BLOWDOWN <br />FINISHED FLOOR <br />4'- 6" MAX. <br />ABOVE FLOOR <br />1 S2" C.W. TO BLDG. <br />DOMESTIC WATER SYSTEM <br />I X" REDUCED <br />PRESSURE BACKFLOW <br />PREVENTER <br />FULL SIZE DRAIN <br />PORT CONNECTION <br />RPBP-1 DRAIN <br />SPILL TO MOP BASIN <br />NOTE: RPBP-1 MANUFACTURER AND INSTALLATION SHALL BE AS APPROVED BY LOCAL & STATE <br />AUTHORITIES. <br />10 1 REDUCED PRESSURE BACKFLOW PREVENTER DETAIL (RPBP-1) <br />QUARTER TURN SHUT OFF <br />VALVE. LOCATE IN <br />ACCESSIBLE LOCATION. <br />TYPICAL <br />CLOSE UP <br />PARTS & <br />INSTALLATION <br />1/2" X 1/2" DROP-EARRED • <br />ELBOW FASTENED TO A I <br />WOODEN SUPPORT IN WALL • <br />CONNECT THE DROP-EARRED <br />ELBOW IN WALL TO A 4" 1/2" <br />BRASS NIPPLE. <br />PROVIDE A CHROME PIPE 0 <br />ESCUTCHEON, TIGHT TO WALL <br />CONNECT THE BRASS NIPPLE <br />TO A 900 BRASS STREET <br />ELBOW. <br />CONNECT STREET ELBOW TO <br />A 1/2" X 3/4" BRASS BUSHING <br />CONNECT BRASS BUSHING TO Q <br />A CHROME PLATED VACUUM <br />BREAKER <br />CONNECT VACUUM BREAKER <br />TO HIGH PRESSURE PET WASH <br />HOSE & SPRAYER ASSEMBLY <br />SELF -SERVE <br />PET WASH <br />WATER SUPPLY LINE <br />OUTLET TO HIGH PRESSURE <br />SPRAYER. <br />SEE CLOSE UP OF PARTS & <br />INSTALLATION FOR <br />ADDITIONAL INFORMATION <br />WATER TEMPERATURE <br />CONTROL LEVER(TMV-1). <br />SET DISCHARGE <br />TEMPERATURE AT 900F. <br />FLOW FRI <br />POTABLE <br />WATER <br />RISER <br />TRAP — <br />PRIMER <br />12" MINIMUM TO <br />HORIZONTAL RUN IN PIPE <br />SCALE: N.T.S. <br />WALL <br />KARP ACCESS <br />DOOR <br />CHROME <br />ESCUTCHEON <br />PLATE <br />FLOW TO <br />FIXTURE <br />AIR GAP VACUUM <br />FLOOR DRAIN <br />BREAKER POINTS <br />VACUUM RELIEF VALVE OR <br />DIP TUBE CONNECTION <br />THERMOMETER <br />HOT WATER TO SYSTEM---\ <br />A.S.M.E. RELIEF VALVE PIPE <br />FULL SIZE TO JAN SINK <br />OR F.D. <br />GALVANIZED NIPPLE (TYPICAL)---,. <br />CHECK VALVE (TYP.) <br />INSTALL IN HORIZONTAL POSITION <br />TYPICAL BALL VALVE <br />COLD WATER TO HEATER <br />AMTROL ST-5 <br />EXPANSION TANK <br />ch I <br />COORDINATE ELECTRICAL <br />CONNECTION REQUIREMENTS <br />WITH ELECTRICIAN WATER DIELECT. UNION (TYPICAL) <br />HEATER <br />DRAIN VALVE, PIPE CONNECTION <br />FINISH FLOOR LINE SIZE TO FLOOR DRAIN <br />NOTE: COORDINATE INSTALLATION WITH WATER HEATER MANUFACTURER'S RECOMMENDATIONS, <br />STATE AND LOCAL CODES. <br />09 1 ELECTRIC WATER HEATER No.1 DETAIL (WH-1) <br />VENT IN WALL UP TO OVERHEAD VENT. <br />REFER TO 2/P2.1 FOR ROUTING. <br />WALL <br />I HOLDING/BATHING <br />TUB <br />WASH TUB LEG <br />DISCHARGE FROM <br />INTERCEPTOR TO BE CUT <br />AT 45° ANGLE <br />FINISH FLOOR <br />LAVATORY SINK <br />TEMPERED HW SUPPLY <br />THERMOSTATIC TEMPERING <br />VALVE, POWER <br />HYDROGUARD SERIE' <br />LFLM495, ASSE 10A <br />HW SUPPLN <br />SCALE: N.T.S. <br />V SUPPLY <br />I'OP VALVE <br />FINISH FLOOR <br />SOLIDS <br />II III ` INTERCEPTOR NOTE: <br />,:: ; :• __ t. TRAP PRIMER TRENCH DRAIN A. INSULATE ALL EXPOSED WASTE AND SUPPLY PIPING <br />. '` ''"• +. •' CONNECTION UNDER LAVATORIES WITH THE HANDI-LAV GUARD <br />•. , '' SANITARY WASTE INSULATION KIT BY TRUEBRO OR EQUAL. <br />PIPING <br />08 PUBLIC PET WASH PIPING DETAIL IN HALF HEIGHT WALL SCALE: N.T.S. 07 TRAP PRIMER DETAIL SCALE: N.T.S. 06 HOLDING/BATHING TUB WITH HAIR SCALE: N.T.S. 05 LAVATORY TEMPERING SCALE: N.T.S. <br />INTERCEPTOR DETAIL VALVE DETAIL <br />r-------------------------- I ---- <br />FILTER BY AQUARIUM t <br />VENDOR. ALL OTHER WOOD RAMP <br />WORK BY P.C. ' TEMPERED WATER SUPPLY VENT IN WALL UP TO OVERHEAD VENT. <br />FULL PORT BALL ..... �cr�e�ce�e�l csc- - - --X� ..cr...... �- - - - c�D � PIPING WITH VACUUM REFER TO 2/P2.1 FOR ROUTING. <br />VALVE 4' x 31" 4' x 31" E t, 3m. 3ma "" '^ F R TIERIs coM ,+�+ BREAKER TO THREADED <br />FO D REPT 2/4i2i1 0 HOSE CONNECTION FOR <br />U HOSE WITH HIGH <br />v WATER TEMPERATURE CONTROL <br />�,,) � � PRESSURE SPRAYER. VALVE WITH CHROME TRIM <br />TEMPERED WATER IN FLEXIBLE WATTS MODEL FS-1 REFER TO PLUMBING RISER <br />HOSE TO GROOMING BATHING LF007 DOUBLE M DRAIN MUST BE DIAGRAM FOR PIPING LEVER <br />TUB. CONNECT TO TUB HOSE CHECK VALVE CLOSE TO WALL, SIZES. 2" 0 OUTLET FOR FORCED AIR <br />WITH SELF CONTAINED SPRAY WITH STRAINER LOCATION CRITICAL DRYER HOSE W/ 1-1/2" PVC HOSE <br />NOZZLE AND ANTI -SIPHON WIDE MOUTH CONNECTOR, TYP. REFER TO <br />3 v DEVICE. BY P.C. 8"x8" FLOOR SINK INTERCEPTOR LOCATED ARCHITECTURAL DETAIL 1/A7.0 <br />_ ® TOP OF FLOOR SINK LEVEL IN TUB DISCHARGE. FOR ADDITIONAL INSTALLATION <br />IN BACK ROOM TYPICAL OF 3. o o INFORMATION. <br />MANUAL SHUT OFF BY P.C. WITH FINISHED FLOOR. <br />VALVE, TYPICAL. TYPICAL OF (1) <br />RECESSED DRYER <br />�O QUARTER TURN VALVE TERMINATING SWITCH, TYP. <br />WALL MOUNTED THERMOSTATIC HB-1 MOUNTING IN 3/4" FEMALE THREADS LOCATED PET WASH BASIN. <br />12" AFF CLOSE TO WALL TURNED TYPICAL OF 3, SANITARY WASTE PIPING <br />MIXING VALVE(TMV-2). SET HEIGHT: 24" AFF DOWN (HEIGHT VARIES) <br />4"1 y <br />DISCHARGE TO 90•F. VALVE CONNECTION FROM <br />MUST BE LOCATED TO HOSE BIBB OUTLET NIBCO MTT-585-70 PLUMBED FROM WATER FILTER. <br />FACILITATE ACCESS FOR BY OTHERS TWO PIECE FULL TYPICAL OF (1). FINISH FLOOR FCO <br />TEMPERATURE ADJUSTMENT PORT BALL VALVE, " <br />AND SERVICING. AQUARIUM VENDOR PROVIDE FEMALE WITH FEMALE T STANDARD HOSE BIB 2' AFF CAPABLE 0 0 IN -FLOOR <br />PET WASH SANITARY <br />FILTER EQUIPMENT THREAD ADAPTOR THREAD OF ACCEPTING STANDARD GARDEN HAIR <br />PIPING LOCATED UNDER <br />AND CONNECTIONS TERMINATION. WATER HOSE. PLUMBED FROM CITY COLD FLOOR MOUNTED PET INTERCEPTOR <br />MOUNTING HEIGHT: <br />TO PIPING BY WATER SUPPLY IN BACK ROOM. BACK ROOM FLOOR DRYERS. ACCESSIBLE INTERCEPTOR LOCATED <br />OTHERS 12" AFF TYPICAL OF (1). THRU ACCESS PANEL, TYP. IN BACK ROOM FLOOR <br />04 HOLDING /BATHING AREA VALVE DETAIL SCALE: N.T.S. 03 1 AQUARIUM FILTERED WATER BACKFLOW PREVENTION DETAIL SCALE: N.T.S. 02 DETAIL AQUARIUM PLUMBING PLAN SCALE: N.T.S. 01 PET WASH PLUMBING DETAIL SCALE: N.T.S. <br />5301 VIRGINIA WAY SUITE 140 <br />BRENTWOOD, TN 37027 <br />v.615.373.2640 f.615.373.4837 <br />email®entechtn.com entechtn.com <br />Z <br />_O <br />H <br />a <br />w <br />0 <br />w <br />a <br />0 <br />w <br />N <br />d' <br />G�3Lo <br />� M <br />J <br />J LL <br />~�J <br />2= <br />W>- <br />N= <br />w <br />N <br />() <br />v, <br />r I� <br />v <br />w <br />Z <br />J <br />Q <br />m <br />� <br />w <br />J <br />Z <br />0 <br />U <br />0. <br />Z <br />u) <br />Q <br />ISSUED FOR: <br />PERMIT 03.14.19 <br />BID 03.14.19 <br />CONSTRUCTION - <br />REVIEW SET - <br />PROJECT MANAGER DESIGNER <br />JOB NO. <br />18390 <br />P200 <br />
The URL can be used to link to this page
Your browser does not support the video tag.