Laserfiche WebLink
PANEL SCHEDULE NOTES: <br />1. CIRCUIT SHALL HAVE LOCK ON TAB. <br />7/16" HIGH LETTERS (TYP) <br />NOTE: <br />*REFER TO LIGHTING CONTROL DIAGRAM FOR <br />A. TIMECLOCK SHALL BE TORK DIGITAL SERIES MODEL <br />CIRCUITS TO BE ROUTED THROUGH <br />EW101 OR APPROVED EQUAL. <br />CONTACTORS <br />2 HOUR TIMED B. CONTACTORS SHALL BE ELECTRICALLY HELD <br />OVERRIDE SWITCH SQUARE D MODEL 8903 WITH POLE QUANTITIES AS <br />(VERIFY LOCATION) INDICATED. INSTALL IN NEMA 1 ENCLOSURE. <br />(CLOSES Cl, C2 C. PHOTOCELL SHALL BE TORK MODEL 2001WITH 1/2" <br />EQ IPMENT DESIGNATION <br />ANDC3) STEM AND SWIVEL. <br />T1 <br />® SYSTEM VOLTAGE ® o <br />Cl <br />H M <br />B-12 SALES LTG <br />SPARE SPARE <br />B-14 SALES LTG <br />FED FROM PANEL 'X' <br />- -SALES LTG <br />B-18 SALES LTG <br />B-20 SALES LTG <br />SPARE SPARE <br />T2 B-22 SALES LTG <br />0'.4" <br />M <br />C2 <br />NOTES: <br />SALES LTG <br />B-45 AQUARIUM LTG <br />1. PROVIDE LAMOCOID NAMEPLATE ENGRAVED WITH WHITE LETTERS. <br />120V, CKT. A-12 B-47 AQUARIUM LTG <br />SPARE SPARE <br />2. NAMEPLATE SHALL BE THE FOLLOWING COLORS: <br />BLACK - NORMAL POWER ON 208/120 VOLT SYSTEM <br />3. SECURE NAMEPLATE TO EQUIPMENT WITH TWO SHEET METAL <br />1 C3 <br />SCREWS. <br />PHOTOCELL MOUNTED A-31 STORE FRONT SIGN (FRONT) <br />4. PROVIDE A NAMEPLATE FOR EVERY MAJOR ELECTRICAL DEVICE OR <br />ON ROOF WITH SPARE SPARE <br />SENSOR FACING SPARE SPARE <br />ELECTRICAL CONTROLS SUCH AS: SWITCHBOARDS, DISTRIBUTION <br />NORTH SPARE SPARE <br />PANELS, PANELBOARDS, LIGHTING CONTROL PANELS, STARTERS, <br />iN <br />DISCONNECT SWITCHES, ETC. (AS APPLICABLE). <br />5. REFER TO ELECTRICAL SPECIFICATIONS FOR FURTHER <br />DESCRIPTION. <br />6. EQUIPMENT DESIGNATION I. <br />F" -PUMP BOARD <br />CONTROL PANEL 'CP-1' CONTROL DIAGRAM <br />ORTYPE OF EQUIPMENT NTT BE SERVED (I.E. PANEL^LPA <br />CWP-1"). <br />SCALE- NONE <br />7. SYSTEM VOLTAGE SHALL INDICATE VOLTAGE AND PHASE SUCH AS: <br />208/120V,30, 208V,10, ETC. <br />8. THE THIRD LINE OF TEXT SHALL INDICATE UPSTREAM POWER <br />SOURCE IDENTIFIED BY ITS NAME, SUCH AS "TRANSFORMER <br />T1", PANEL "LPA", ETC. <br />04 <br />LIGHTING CONTROL DIAGRAM <br />SCALE: N.T.S. <br />NOTE: <br />1. CONTRACTOR SHALL COORDINATE WITH LANDLORD AND BUILDINGS MAIN DISTRIBUTION PANEL, AND <br />DETERMINE IN FIELD IF SERVICE ENTRANCE GROUND IS LOCATED IN "MAIN DISCONNECT" OR IF SERVICE <br />ENTRANCE GROUND MUST ORIGINATE IN PANEL'H-A'. PROVIDE GROUNDING AS REQUIRED PER NEC AND <br />LOCAL JURISDICTION. <br />2. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH LANDLORD FOR MULTI -TENANT <br />METER BANK LOCATION, AND ROUTING OF FEEDERS FROM LOCATION TO SPACE INDICATED HEREIN. REPORT <br />06 <br />NAMEPLATE DETAIL <br />SCALE: N.T.S. <br />ANY DISCREPANCIES TO ENGINEER PRIOR TO ROUGH -IN. CONTRACTOR SHALL DETERMINE AND PROVIDE <br />MAXIMUM DEMAND LOAD OF LANDLORDS SYSTEM TO LOCAL JURISDICTION AND VERIFY NO OVERLOADS ON <br />DOWNSTREAM PANELS OR FEEDERS BEFORE START OF WORK. <br />05 <br />NOT USED <br />SCALE: N.T.S. <br />3#2/0,1#6(G),2"C. 4#500kcmil, #3(G), 1#3(IG), 4"C <br />PROVIDE 175A/3P <br />CIRCUIT BREAKER <br />LANDLORD IS RESPONSIBLE IN PANEL'H-A'. <br />FOR PROVIDING SERVICE TO <br />PANEL'H-A'. PROVIDED SERVICE <br />SHALL BE A MINIMUM OF 480/277 MOUNTED ON <br />VOLTS, 3�, 400 AMPS. PLATFORM <br />CIRCUIT BREAKER <br />ABOVE <br />PANELBOARD <br />XFMR <br />ENCLOSURE <br />UTILITY APPROVED <br />GND <br />PROVIDE COPPER GROUNDING <br />GROUND <br />CT CABINET/METER PER <br />PER NEC <br />BUS AND INSTALL IN SERVICE <br />WIREWAY IN ACCORDANCE WITH 2 (TYPICAL) <br />COORDINATE ALL <br />N.E.C. ARTICLE #250. NEUTRAL <br />REQUIREMENTS WITH THE 112.5KVA <br />WIREWAY <br />LOCAL POWER COMPANY. 480V-3t -3W PRI <br />EQUIP. GND. BUS <br />208Y/120V-3f-4W <br />INCOMING CONDUIT GROUND <br />(TYPICAL OF 3) 3 <br />SEC — <br />O 4#3/0, 1#6(G), 1#6(IG), 3"C. <br />4#500MCM, <br />5 <br />1#3(G),1#3(IG) , <br />EQUIP. GND. BUS VERIFY EXISTING GROUNDING SYSTEM IS COMPLIANT <br />40OA/3F PANEL'H-A' 3 1/2"C. PANEL'A' PANEL'B' <br />WITH LATEST EDITION OF THE N.E.C. AS SHOWN AND <br />480/277V <br />4 NOTED HERE. INFORM CONSTRUCTION MANAGER & <br />30, 4W <br />UNDERGROUND METAL WATER ENGINEER OF ANY DEFICIENCIES. <br />NEMA 3R 400A 208Y/120V 208Y/120V <br />LINE IN DIRECT CONTACT WITH 1 <br />MAIN 480/277V 3�-4W 3�-4W <br />EARTH FOR AT LEAST 10'. <br />SERVICE 30, 4W 400/3 225A <br />SERVICE GROUNDING SYSTEM WIRING DIAGRAM NOTES: <br />DISCONNEC M.C.B. MCB MLO <br />O THE GROUNDING ELECTRODE CONDUCTORS SHALL BE <br />SOURCE M SIZED PER TABLE 250-66 OF THE NEC. MINIMUM #110 CU. <br />PROVIDE NEUTRAUGROUND <br />O GROUND CONDUCTORS TO OTHER POINTS AND <br />BONDING, IF REQUIRED. <br />GROUNDING JUMPER EQUIPMENT, AS REQUIRED BY NEC ARTICLE 250. <br />VERIFY SERVICE GROUND <br />AROUND METER AND <br />LOCATION IN FIELD. <br />ANY NON-METALLIC PIPE O SERVICE ENTRANCE CONDUCTORS WITH GROUNDED <br />SECTIONS (TYPICAL) <br />(NEUTRAL) CONDUCTOR AND EQUIPMENT <br />480/277V OPTION <br />PROVIDE DRIVEN GROUND(S) EFFECTIVELY O LOCATION OF PERMITTED CONNECTION POINT FOR <br />ROD WITH A MINIMUM OF <br />GROUNDED BUILDING INTERSYSTEM BONDING AND GROUNDING CONDUCTOR IN <br />10'-0" OF COVER <br />STEEL COLUMN ACCORDANCE WITH N.E.C. ARTICLE #250.94. PROVIDE <br />TERMINAL, BONDING BAR, ETC. LISTED FOR USE AS <br />GROUNDING AND BONDING EQUIPMENT. <br />SERVICE GROUNDING SYSTEM WIRING DIAGRAM <br />GROUND PER NEC <br />NO SCALE O GROUND CONDUCTOR(S) TO ALL OTHER SYSTEMS PER <br />_ ARTICLE 250. <br />N.E.C.250. <br />4#500MCM, 3 1/2"C. <br />TO UTILITY TRANSFORMER. <br />COORDINATE ALL <br />REQUIREMENTS WITH THE <br />LOCAL POWER COMPANY. <br />03 <br />NOT USED <br />SCALE: N.T.S. <br />02 <br />SERVICE GROUNDING SYSTEM WIRING DIAGRAM <br />SCALE: N.T.S. <br />01 <br />SINGLE LINE POWER RISER DIAGRAM <br />SCALE: N.T.S. <br />ENTECH <br />ENGINEERING INC. <br />5301 VIRGINIA WAY SUITE 140 <br />BRENTWOOD, TN 37027 <br />v. 615.3 73.2 640 1. 615.3 73.483 7 <br />email®entechtn.com entechtn.com <br />O <br />H <br />a <br />U <br />U) <br />w <br />a <br />w <br />Q <br />0 <br />; <br />w <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I I <br />•'�t�►AN. <br />m►�e cr • <br />!� <br />:� ••�''•MOR10. '• • <br />Room Ross •• <br />3�15J� <br />>9 <br />a <br />N <br />_j <br />i ch QWJ <br />j< <br />Q W <br />~wD <br />W� JUG <br />N a W Cn z <br />W Q <br />N <br />ISSUED FOR: <br />PERMIT 03.14.19 <br />BID 03.14.19 <br />CONSTRUCTION - <br />REVIEW SET - <br />PROJECT MANAGER DESIGNER <br />JOB NO. <br />18390 <br />E3mO <br />