<br />SECTION 102800 - TOILET AND BATH ACCESSORIES (CONTINUED)
<br />1.10 iNSTALLA T ION
<br />A. 'VERIFY THAT BLOCKING, BRACING, AND OTHER SUPPORT MEMBERS AND ANCHORAGE HAVE BEENINSTALLED WITHIN
<br />ALIGNMENT TOLERANCES REQUIRED BY TOILET ACCESSORY MANUFACTURER.
<br />B, INSTALL ACCESSORIES ACCORDING TC M.AlvUr-ACTURE>,.S 4VRi TEN INSTRUCTIONS. USING VANDAL -RESISTANT FASTENERS
<br />APPROPRIATE TO SUBSTRATE INDICATED AND RECOMMENDED BY UNIT MANUFACTURER. iNSTALL UNITS LEVEL, PLUMB, AND
<br />FIRMLY ANCHORED IN LOCATIONS AND AT HEIGHTS INDICATED.
<br />C. CRAB BARS: INSTALL TO WITHSTAND A DOWNWARD LOAD OF AT LEAST 250 LSF, WHEN TESTED ACCORDING TO METHOD IN
<br />ASTM F446.
<br />1.15 ADJUSTING AND CLEANING
<br />A. ADJUST ACCESSORIES FOR UNENCUMBERED, SMOOTH OPERATION. REPLACE DAMAGED OR DEFECTIVE ITEMS,
<br />B. REMOVE TEMPORARY LABELS AND PROTECTIVE COATINGS.
<br />C. CLEAN AND POLISH EXPOSED SURFACES ACCORDING TO MANUFACTURER'S WRITTEN RECOMMENDATIONS.
<br />SECTION 104413 - FIRE EXTINGUISHERS AND CABINETS
<br />1.1 SUMMARY
<br />A. SECTION INCLUDES:
<br />1, PORTABLE, HAND -CARRIED FIRE EXTINGUISHERS AND MOUNTING BRACKETS.
<br />2. FIRE -PROTECTION CABINETS AND ACCESSORIES.
<br />1.2 ACTION SUBMITTALS: REFER TO THE REQUIRED SUBMITTAL LOG IN SECTION 013300 - SUBMITTAL PROCEDURES
<br />1.3 CLOSEOUT SUBMITTALS: OPERATION AND MAINTENANCE DATA.
<br />1.4 QUALITY ASSURANCE
<br />A. PROVIDE UNITS CONFORMING WITH NFPA 10 FOR PORTABLE FIRE EXTINGUISHERS.
<br />B. COORDINATE TYPE AND CAPACITY OF FIRE EXTINGUISHERS WITH FIRE -PROTECTION CABINETS TO ENSURE FIT AND
<br />FUNCTION.
<br />C. COORDINATED SIZES AND LOCATIONS OF FIRE -PROTECTION CABINETS WITH WALL DEPTHS.
<br />1.5 WARRANTY
<br />A. SPECIAL WARRANTY: MANUFACTURER'S STANDARD FORM IN WHICH MANUFACTURER AGREES TO REPAIR OR REPLACE FIRE
<br />EXTINGUISHERS THAT FAIL IN MATERIALS OR WORKMANSHIP WITHIN SPECIFIED WARRANTY PERIOD.
<br />1. WARRANTY PERIOD: SIX YEARS FROM DATE OF SUBSTANTIAL COMPLETION.
<br />1.6 PERFORMANCE REQUIREMENTS:
<br />A. FIRE EXTINGUISHERS: LISTED AND LABELED FOR TYPE, RATING, AND CLASSIFICATION BY AN INDEPENDENT TESTING AGENCY
<br />ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION.
<br />1.7 PORTABLE, HAND -CARRIED FIRE EXTINGUISHERS
<br />A. FIRE EXTINGUISHERS: TYPE, SIZE, AND CAPACITY FOR EACH FIRE -PROTECTION CABINET AND MOUNTING BRACKET INDICATED
<br />1. INSTRUCTION LABELS: INCLUDE PICTORIAL. MARKING SYSTEM COMPLYING WITH NFPA 10, APPENDIX B, AND BAR CODING FOR
<br />DOCUMENTING FIRE-EXTINGUISHER LOCATION, INSPECTIONS, MAINTENANCE, AND RECHARGING.
<br />B. MUL T IPURPOSE DRY -CHEMICAL TYPE: UL-RATED EXTINGUISHER UNIT CONTAINING A FLUIDIZED AND SILICONIZED MONO
<br />AMMONIUM PHOSPHATE POWDER; NONCONDUCTIVE AND NONTOXIC.
<br />1. PRODUCT: REFER TO EQUIPMENT SCHEDULE ON LIFE SA'rETY PLAN.
<br />2. CONSTRUCTION: HEAVY DUTY STEEL CYLINDER WITH METAL VALVE AND SIPHON TUBE, O-RING SEAL, REPLACEABLE VALVE
<br />STEM SEAL, VISUAL PRESSURE GAGE, PULL PIN AND UPRIGHT SQUEEZE GRIP.
<br />3. FINISH: FACTORY POWDER -COATED; RED.
<br />4. EFFECTIVENESS (RATING): CLASS A, B, .AND C FIRES.
<br />1.2 SEMMI-RECESSED FIRE EX!NGUISHER CABINETS
<br />A. CABINET WITH ALUMINUM TRIM AND DOOR: REFER TO EQUIPMENT SCHEDULE ON LIFE SAFETY PLAN.
<br />1. CABINET STYLE: SEMI -RECESSED, 3 INCH ROLLED EDGE.
<br />2. COMPONENTS:
<br />a. TUB: ROLLED STEEL.
<br />b. DOOR AND TRIM CONSTRUCTION: ROLLED STEEL WITH 5/8 INCH DOORSTOP ATTACHED BY CONTINUOUS HINGE WITH ZINC
<br />PLATED HANDLE AND ROLLER CATCH.
<br />c. FINISH: WHITE POWDER COAT FINISH.
<br />d, DOOR STYLE: TYPE V, VERTICAL DUO.
<br />e. DOOR GLAZING: CLEAR TEMPERED.
<br />f. ADDITIONAL OPTIONS:
<br />1) 'VERTICAL LETTERING.
<br />a) TYPE: DECAL LETTERING.
<br />b) TEXT: FIRE EXTINGUISHER.
<br />c) COLOR: RED.
<br />2) DOOR HARDWARE:
<br />a) STANDARD ZINC -PLATED HANDLE.
<br />1.9 MOUNTING BRACKETS - WHERE APPLICABLE
<br />A. MOUNTING BRACKETS: MANUFACTURER'S STANDARD STEEL, DESIGNED TO SECURE FIRE EXTINGUISHER TO WALL OR
<br />STRUCTURE, OF SIZES REQUIRED FOR TYPES AND CAPACITIES OF FIRE EXTINGUISHERS INDICATED, WITH PLATED OR RED
<br />BAKED -ENAMEL FINISH.
<br />B. IDENTIFICATION: LETTERING COMPLYING WITH AUTHORITIES HAVING JURISDICTION FOR LETTER STYLE, SIZE, SPACING, AND
<br />LOCATION. LOCATE AS INDICATED BY FIRE MARSHAL.
<br />SECTION 123661 - SOLID SURFACE COUNTERTOPS
<br />1.1 SUMMARY
<br />A. SECTION INCLUDES:
<br />1, SOLID SURFACE MATERIAL COUNTERTOPS.
<br />2. SOLID SURFACE MATERIAL BACKSPLASHES.
<br />3. SOLID SURFACE MATERIAL END SPLASHES.
<br />4. SOLID SURFACE MATERIAL APRON FRONTS.
<br />5. SOLID SURFACE MATERIAL SINKS.
<br />1.2 ACTION SUBMITTALS
<br />A. REFER TO THE REQUIRED SUBMITTAL LOGIN SECTION 013300 -SUBMITTAL PROCEDURES.
<br />B. PRODUCT DATA: FOR COUNTERTOP MATERIALS AND SINKS.
<br />C. SUSTAINABLE DESIGN SUBMITTALS:
<br />1. FOR ADHESIVES AND COMPOSITE WOOD PRODUCTS, DOCUMENTATION INDICATING THAT PRODUCT CONTAINS NO UREA
<br />FORMALDEHYDE.
<br />2. FOR ADHESIVES AND SEALANTS, DOCUMENTATION INDICATING THAT PRODUCTS COMPLY WITH THE TESTING AND PRODUCT
<br />REQUIREMENTS OF THE CALIFORNIA DEPARTMENT OF HEALTH SERVICES' "STANDARD PRACTICE FOR THE TESTING OF VOLATILE
<br />ORGANIC EMISSIONS FROM VARIOUS SOURCES USING SMALL-SCALE ENVIRONMENTAL CHAMBERS."
<br />3. RECYCLED CONTENT DOCUMENTATION INCLUDING PRE -CONSUMER AND POST -CONSUMER RECYCLED CONTENT,
<br />4. DOCUMENTATION INDICATING THAT MATERIALS ARE REGIONALLY MANUFACTURED AND WITHIN 500 MILES OF THE PROJECT
<br />SITE,
<br />D. CHEMICAL -RESISTANCE DATA.
<br />E. SHOP DRAWINGS: FOR COUNTERTOPS. SHOW MATERIALS, FINISHES, EDGE AND BACKSPLASH PROFILES, METHODS OF
<br />JOINING, AND CUTOUTS FOR PLUMBING FIXTURES.
<br />F. SAMPLES: VERIFY WITH ARCHITECT.
<br />1.3 WARRANTY
<br />A. PROVIDE MANUFACTURER'S WARRANTY AGAINST DEFECTS IN MATERIALS.
<br />1. WARRANTY SHALL PROVIDE MATERIAL AND LABOR TO REPAIR OR REPLACE DEFECTIVE MATERIALS.
<br />2. DAMAGE CAUSED BY PHYSICAL OR CHEMICAL ABUSE OR DAMAGE FROM EXCESSIVE HEAT WILL NOT BE WARRANTED.
<br />B. OPTIONAL INSTALLED WARRANTY
<br />1. TO QUALIFY FOR THE OPTIONAL INSTALLED WARRANTY, FABRICATION AND INSTALLATION MUST BE PERFORMED BY A
<br />MANUFACTURER -CERTIFIED FABRICATION/INSTALLATION SOURCE WHO WILL PROVIDE A BRAND PLATE FOR THE APPLICATION.
<br />2. THIS WARRANTY COVERS ALL FABRICATION AND INSTALLATION PERFORMED BY THE CERTIFIED/APPROVED SOURCE SUBJECT
<br />TO THE SPECIFIC WORDING CONTAINED IN THE INSTALLED WARRANTY CARD.
<br />C. MANUFACTURER'S WARRANTY PERIOD:
<br />1. TEN YEARS FROM DATE OF SUBSTANTIAL COMPLETION.
<br />1.4 MAINTENANCE: PROVIDE MAINTENANCE REQUIREMENTS AS SPECIFIED BY THE MANUFACTURER
<br />1.5 SOLID SURFACE COUNTERTOP COMPONENTS
<br />A. CONFIGURATION: PROVIDE COUNTERTOPS WITH THE FOLLOWING FRONT AND BACKSPLASH STYLE:
<br />1. FRONT:
<br />a. SLIGHTLY EASED AT EXPOSED EDGES WITH 1-1/2" HIGH FACE
<br />b. NO -DRIP PROFILE AT TOP EDGE WITH 1-1/2" HIGH FACE, UNLESS NOTED OTHERWISE ON DRAWINGS.
<br />2. BACKSPLASH AND SIDESPLASH:
<br />a. SLIGHTLY EASED AT EXPOSED CORNERS AND EDGES.
<br />B. COUNTERTOPS: 1/2-INCH THICK, SOLID SURFACE MATERIAL LAMINATED TO 3/4-INCH THICK PARTICLEBOARD WITH EXPOSED
<br />EDGES BUILT UP WITH 1/2-INCH THICK, SOLID SURFACE MATERIAL.
<br />C. BACKSPLASHES: 3/4-INCH THICK, SOLID SURFACE MATERIAL.
<br />1.6 MATERIALS
<br />A. CERTIFIED WOOD MATERIALS: FABRICATE COUNTERTOPS WITH WOOD AND WOOD -BASED PRODUCTS PRODUCED FROM WOOD
<br />OBTAINED FROM FORESTS CERTIFIED BY AN FSC-ACCREDITED CERTIFICATION BODY TO COMPLY WITH FSC STD-01-001, "FSC
<br />PRINCIPLES AND CRITERIA FOR FOREST STEWARDSHIP."
<br />B. COMPOSITE WOOD AND AGRIFIBER PRODUCTS: PROVIDE PRODUCTS THAT COMPLY WITH THE TESTING AND PRODUCT
<br />REQUIREMENTS OF THE CALIFORNIA DEPARTMENT OF HEALTH SERVICES""STANDARD PRACTICE FOR THE TESTING OF VOLATILE
<br />ORGANIC EMISSIONS FROM VARIOUS SOURCES USING SMALL-SCALE ENVIRONMENTAL CHAMBERS," INCLUDING 2004 ADDENDA.
<br />C. PARTICLEBOARD: ANSI A208.1, GRADE M-2, MADE WITH BINDER CONTAINING NO UREA FORMALDEHYDE.
<br />D. ADHESIVES: ADHESIVES SHALL COMPLY WITH THE TESTING AND PRODUCT REQUIREMENTS OF THE CALIFORNIA DEPARTMENT
<br />OF HEALTH SERVICES' "STANDARD PRACTICE FOR THE TESTING OF VOLATILE ORGANIC EMISSIONS FROM VARIOUS SOURCES
<br />USING SMALL-SCALE ENVIRONMENTAL CHAMBERS."
<br />1. JOINT ADHESIVE: MANUFACTURER'S STANDARD ONE- OR TWO-PART ADHESIVE KIT TO CREATE INCONSPICUOUS, NONPOROUS
<br />JOINTS.
<br />2. SEALANT: MANUFACTURER'S STANDARD MILDEW -RESISTANT, FDA -COMPLIANT, NSF 51-COMPLIANT (FOOD ZONE -ANY TYPE),
<br />UL-LISTED SILICONE SEALANT IN COLORS MATCHING COMPONENTS.
<br />3. SINK MOUNTING HARDWARE: MANUFACTURER'S STANDARD BOWL CLIPS, PANEL INSERTS AND FASTENERS FOR ATTACHMENT
<br />OF UNDERMOUNT SINKS.
<br />E. SOLID SURFACE MATERIAL: HOMOGENEOUS -FILLED PLASTIC RESIN COMPLYING WITH ICPA SS-1.
<br />1. MANUFACTURER: REFER TO FINISH SCHEDULE ON DRAWINGS.
<br />2. INTEGRAL SINK BOWLS: COMPLY WITH ISSFA-2 AND ANSI Z124.3, TYPE 5 OR TYPE 6, WITHOUT A PRECOATED FINISH.
<br />a. MODEL: REFER TO FINISH SCHEDULE ON DRAWINGS.
<br />3. COLOR AND PATTERNS:
<br />a. COUNTERTOPS: REFER TO FINISH SCHEDULE ON DRAWINGS.
<br />b. INTEGRAL SINKS: REFER TO FINISH SCHEDULE ON DRAWINGS.
<br />F. SHAPES MEET OR EXCEED THE ANSI Z124.3 AND ANSI Z124.6 STANDARDS FOR PLASTIC SINKS AND LAVATORIES.
<br />1.7 EXAMINATION
<br />A. EXAMINE SUBSTRATES AND CONDITIONS, WITH FABRICATOR PRESENT FOR COMPLIANCE WITH REQUIREMENTS FOR
<br />INSTALLATION TOLERANCES AND OTHER CONDITIONS AFFECTING PERFORMANCE OF WORK.
<br />B. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED.
<br />1.8 INSTALLATION
<br />A. INSTALL COMPONENTS PLUMB, LEVEL AND RIGID, SCRIBED TO ADJACENT FINISHES, IN ACCORDANCE WITH APPROVED SHOP
<br />DRAWINGS AND PRODUCT DATA.
<br />1. PROVIDE PRODUCT IN THE LARGEST PIECES AVAILABLE.
<br />2, FORM FIELD JOINTS USING MANUFACTURER'S RECOMMENDED ADHESIVE, WITH JOINTS INCONSPICUOUS IN FINISHED WORK.
<br />a. EXPOSED JOINTS/SEAMS SHALL NOT BE ALLOWED.
<br />3. REINFORCE FIELD JOINTS WITH SOLID SURFACE STRIPS EXTENDING A MINIMUM OF 1 INCH ON EITHER SIDE OF THE SEAM WITH
<br />THE STRIP BEING THE SAME THICKNESS AS THE TOP.
<br />4. CUT AND FINISH COMPONENT EDGES WITH CLEAN, SHARP RETURNS.
<br />5. ROUT RADII AND CONTOURS TO TEMPLATE.
<br />6, ANCHOR SECURELY TO BASE CABINETS OR OTHER SUPPORTS.
<br />7. ALIGN ADJACENT COUNTERTOPS AND FORM SEAMS TO COMPLY WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS USING
<br />ADHESIVE IN COLOR TO MATCH COUNTERTOP,
<br />8. CAREFULLY DRESS JOINTS SMOOTH, REMOVE SURFACE SCRATCHES AND CLEAN ENTIRE SURFACE.
<br />9. INSTALL COUNTERTOPS WITH NO MORE THAN 1/8-INCH (3 MM) SAG, BOW OR OTHER VARIATION FROM A STRAIGHT LINE.
<br />B. APPLIED BACKSPLASHES AND SIDESPLASHES:
<br />1. INSTALL APPLIED SIDESPLASHES USING MANUFACTURER'S STANDARD COLOR -MATCHED SILICONE SEALANT,
<br />2. ADHERE APPLIED SIDESPLASHES TO COUNTERTOPS USING MANUFACTURER'S STANDARD COLORMATCHED SILICONE
<br />SEALANT. C. INTEGRAL SINKS:
<br />3, PROVIDE SOLID SURFACE MATERIALS BOWLS AND/OR LAVATORIES SINKS WITH OVERFLOWS IN LOCATIONS SHOWN ON THE
<br />DRAWINGS.
<br />4. SECURE SINKS AND LAVATORY BOWLS TO TOPS USING MANUFACTURER'S RECOMMENDED SEALANT, ADHESIVE AND
<br />MOUNTING HARDWARE TO MAINTAIN WARRANTY.
<br />1.9 REPAIR
<br />A. REPAIR OR REPLACE DAMAGED WORK WHICH CANNOT BE REPAIRED TO ARCHITECT'S SATISFACTION.
<br />1.10 CLEANING AND PROTECTION
<br />A. KEEP COMPONENTS CLEAN DURING INSTALLATION.
<br />B. REMOVE ADHESIVES, SEALANTS AND OTHER STAINS.
<br />s
<br />e� 10 Ras
<br />s m>
<br />170E if " ' Drive
<br />6 :3 ¢
<br />Tampa, #{'lipt-".3'P �.;'`,�`�0•,
<br />°AA333
<br />A!! reproduction & inteliectua6 property
<br />rights reserved 2017
<br />Project
<br />Fiavita
<br />ZEI!►` _ -
<br />FL 33542
<br />Prepared for
<br />DAVITA MEDICAL GROUP
<br />In Assoriat!Cn with.
<br />CONTACT: KARL HEES
<br />1381 51 H ST
<br />SARASOTA, FL 34236
<br />PHONE: 941.955.4555
<br />GENESIS ENGINEER GROUP, LLC
<br />CONTACT: MIKE HANEY
<br />1000 N. ASH. LEY CJR. #9001
<br />TAMPA, FL
<br />PHONE: 813,523,6455
<br />GENESIS ENGINEER GROUP, LLC
<br />CONTACT. MICE ;-IANEY
<br />1000 N. ASHLEY DR. #90-01 FL
<br />PHONE: 813,523.6455
<br />��Andrew J. Dohmen, A:=- # 12.11012_10 18
<br />15605 11:22:44 AM
<br />No. Revision Description Date
<br />1 PERMIT AND BID SET 12/10/2018
<br />No. Revision Desortstlon Date
<br />Draw i By: ,+nu; Checked By: ;'?C
<br />('noiect Number:
<br />Sheet Titie
<br />Orlgina', drawing is 24 x 36 Dc not
<br />scale curitefits of drawing
<br />Sheet Number
<br />SECTION 102800 - TOILET AND BATH ACCESSORIES (CONTINUED)
<br />1.10 iNSTALLA T ION
<br />A. 'VERIFY THAT BLOCKING, BRACING, AND OTHER SUPPORT MEMBERS AND ANCHORAGE HAVE BEENINSTALLED WITHIN
<br />ALIGNMENT TOLERANCES REQUIRED BY TOILET ACCESSORY MANUFACTURER.
<br />B, INSTALL ACCESSORIES ACCORDING TC M.AlvUr-ACTURE>,.S 4VRi TEN INSTRUCTIONS. USING VANDAL -RESISTANT FASTENERS
<br />APPROPRIATE TO SUBSTRATE INDICATED AND RECOMMENDED BY UNIT MANUFACTURER. iNSTALL UNITS LEVEL, PLUMB, AND
<br />FIRMLY ANCHORED IN LOCATIONS AND AT HEIGHTS INDICATED.
<br />C. CRAB BARS: INSTALL TO WITHSTAND A DOWNWARD LOAD OF AT LEAST 250 LSF, WHEN TESTED ACCORDING TO METHOD IN
<br />ASTM F446.
<br />1.15 ADJUSTING AND CLEANING
<br />A. ADJUST ACCESSORIES FOR UNENCUMBERED, SMOOTH OPERATION. REPLACE DAMAGED OR DEFECTIVE ITEMS,
<br />B. REMOVE TEMPORARY LABELS AND PROTECTIVE COATINGS.
<br />C. CLEAN AND POLISH EXPOSED SURFACES ACCORDING TO MANUFACTURER'S WRITTEN RECOMMENDATIONS.
<br />SECTION 104413 - FIRE EXTINGUISHERS AND CABINETS
<br />1.1 SUMMARY
<br />A. SECTION INCLUDES:
<br />1, PORTABLE, HAND -CARRIED FIRE EXTINGUISHERS AND MOUNTING BRACKETS.
<br />2. FIRE -PROTECTION CABINETS AND ACCESSORIES.
<br />1.2 ACTION SUBMITTALS: REFER TO THE REQUIRED SUBMITTAL LOG IN SECTION 013300 - SUBMITTAL PROCEDURES
<br />1.3 CLOSEOUT SUBMITTALS: OPERATION AND MAINTENANCE DATA.
<br />1.4 QUALITY ASSURANCE
<br />A. PROVIDE UNITS CONFORMING WITH NFPA 10 FOR PORTABLE FIRE EXTINGUISHERS.
<br />B. COORDINATE TYPE AND CAPACITY OF FIRE EXTINGUISHERS WITH FIRE -PROTECTION CABINETS TO ENSURE FIT AND
<br />FUNCTION.
<br />C. COORDINATED SIZES AND LOCATIONS OF FIRE -PROTECTION CABINETS WITH WALL DEPTHS.
<br />1.5 WARRANTY
<br />A. SPECIAL WARRANTY: MANUFACTURER'S STANDARD FORM IN WHICH MANUFACTURER AGREES TO REPAIR OR REPLACE FIRE
<br />EXTINGUISHERS THAT FAIL IN MATERIALS OR WORKMANSHIP WITHIN SPECIFIED WARRANTY PERIOD.
<br />1. WARRANTY PERIOD: SIX YEARS FROM DATE OF SUBSTANTIAL COMPLETION.
<br />1.6 PERFORMANCE REQUIREMENTS:
<br />A. FIRE EXTINGUISHERS: LISTED AND LABELED FOR TYPE, RATING, AND CLASSIFICATION BY AN INDEPENDENT TESTING AGENCY
<br />ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION.
<br />1.7 PORTABLE, HAND -CARRIED FIRE EXTINGUISHERS
<br />A. FIRE EXTINGUISHERS: TYPE, SIZE, AND CAPACITY FOR EACH FIRE -PROTECTION CABINET AND MOUNTING BRACKET INDICATED
<br />1. INSTRUCTION LABELS: INCLUDE PICTORIAL. MARKING SYSTEM COMPLYING WITH NFPA 10, APPENDIX B, AND BAR CODING FOR
<br />DOCUMENTING FIRE-EXTINGUISHER LOCATION, INSPECTIONS, MAINTENANCE, AND RECHARGING.
<br />B. MUL T IPURPOSE DRY -CHEMICAL TYPE: UL-RATED EXTINGUISHER UNIT CONTAINING A FLUIDIZED AND SILICONIZED MONO
<br />AMMONIUM PHOSPHATE POWDER; NONCONDUCTIVE AND NONTOXIC.
<br />1. PRODUCT: REFER TO EQUIPMENT SCHEDULE ON LIFE SA'rETY PLAN.
<br />2. CONSTRUCTION: HEAVY DUTY STEEL CYLINDER WITH METAL VALVE AND SIPHON TUBE, O-RING SEAL, REPLACEABLE VALVE
<br />STEM SEAL, VISUAL PRESSURE GAGE, PULL PIN AND UPRIGHT SQUEEZE GRIP.
<br />3. FINISH: FACTORY POWDER -COATED; RED.
<br />4. EFFECTIVENESS (RATING): CLASS A, B, .AND C FIRES.
<br />1.2 SEMMI-RECESSED FIRE EX!NGUISHER CABINETS
<br />A. CABINET WITH ALUMINUM TRIM AND DOOR: REFER TO EQUIPMENT SCHEDULE ON LIFE SAFETY PLAN.
<br />1. CABINET STYLE: SEMI -RECESSED, 3 INCH ROLLED EDGE.
<br />2. COMPONENTS:
<br />a. TUB: ROLLED STEEL.
<br />b. DOOR AND TRIM CONSTRUCTION: ROLLED STEEL WITH 5/8 INCH DOORSTOP ATTACHED BY CONTINUOUS HINGE WITH ZINC
<br />PLATED HANDLE AND ROLLER CATCH.
<br />c. FINISH: WHITE POWDER COAT FINISH.
<br />d, DOOR STYLE: TYPE V, VERTICAL DUO.
<br />e. DOOR GLAZING: CLEAR TEMPERED.
<br />f. ADDITIONAL OPTIONS:
<br />1) 'VERTICAL LETTERING.
<br />a) TYPE: DECAL LETTERING.
<br />b) TEXT: FIRE EXTINGUISHER.
<br />c) COLOR: RED.
<br />2) DOOR HARDWARE:
<br />a) STANDARD ZINC -PLATED HANDLE.
<br />1.9 MOUNTING BRACKETS - WHERE APPLICABLE
<br />A. MOUNTING BRACKETS: MANUFACTURER'S STANDARD STEEL, DESIGNED TO SECURE FIRE EXTINGUISHER TO WALL OR
<br />STRUCTURE, OF SIZES REQUIRED FOR TYPES AND CAPACITIES OF FIRE EXTINGUISHERS INDICATED, WITH PLATED OR RED
<br />BAKED -ENAMEL FINISH.
<br />B. IDENTIFICATION: LETTERING COMPLYING WITH AUTHORITIES HAVING JURISDICTION FOR LETTER STYLE, SIZE, SPACING, AND
<br />LOCATION. LOCATE AS INDICATED BY FIRE MARSHAL.
<br />SECTION 123661 - SOLID SURFACE COUNTERTOPS
<br />1.1 SUMMARY
<br />A. SECTION INCLUDES:
<br />1, SOLID SURFACE MATERIAL COUNTERTOPS.
<br />2. SOLID SURFACE MATERIAL BACKSPLASHES.
<br />3. SOLID SURFACE MATERIAL END SPLASHES.
<br />4. SOLID SURFACE MATERIAL APRON FRONTS.
<br />5. SOLID SURFACE MATERIAL SINKS.
<br />1.2 ACTION SUBMITTALS
<br />A. REFER TO THE REQUIRED SUBMITTAL LOGIN SECTION 013300 -SUBMITTAL PROCEDURES.
<br />B. PRODUCT DATA: FOR COUNTERTOP MATERIALS AND SINKS.
<br />C. SUSTAINABLE DESIGN SUBMITTALS:
<br />1. FOR ADHESIVES AND COMPOSITE WOOD PRODUCTS, DOCUMENTATION INDICATING THAT PRODUCT CONTAINS NO UREA
<br />FORMALDEHYDE.
<br />2. FOR ADHESIVES AND SEALANTS, DOCUMENTATION INDICATING THAT PRODUCTS COMPLY WITH THE TESTING AND PRODUCT
<br />REQUIREMENTS OF THE CALIFORNIA DEPARTMENT OF HEALTH SERVICES' "STANDARD PRACTICE FOR THE TESTING OF VOLATILE
<br />ORGANIC EMISSIONS FROM VARIOUS SOURCES USING SMALL-SCALE ENVIRONMENTAL CHAMBERS."
<br />3. RECYCLED CONTENT DOCUMENTATION INCLUDING PRE -CONSUMER AND POST -CONSUMER RECYCLED CONTENT,
<br />4. DOCUMENTATION INDICATING THAT MATERIALS ARE REGIONALLY MANUFACTURED AND WITHIN 500 MILES OF THE PROJECT
<br />SITE,
<br />D. CHEMICAL -RESISTANCE DATA.
<br />E. SHOP DRAWINGS: FOR COUNTERTOPS. SHOW MATERIALS, FINISHES, EDGE AND BACKSPLASH PROFILES, METHODS OF
<br />JOINING, AND CUTOUTS FOR PLUMBING FIXTURES.
<br />F. SAMPLES: VERIFY WITH ARCHITECT.
<br />1.3 WARRANTY
<br />A. PROVIDE MANUFACTURER'S WARRANTY AGAINST DEFECTS IN MATERIALS.
<br />1. WARRANTY SHALL PROVIDE MATERIAL AND LABOR TO REPAIR OR REPLACE DEFECTIVE MATERIALS.
<br />2. DAMAGE CAUSED BY PHYSICAL OR CHEMICAL ABUSE OR DAMAGE FROM EXCESSIVE HEAT WILL NOT BE WARRANTED.
<br />B. OPTIONAL INSTALLED WARRANTY
<br />1. TO QUALIFY FOR THE OPTIONAL INSTALLED WARRANTY, FABRICATION AND INSTALLATION MUST BE PERFORMED BY A
<br />MANUFACTURER -CERTIFIED FABRICATION/INSTALLATION SOURCE WHO WILL PROVIDE A BRAND PLATE FOR THE APPLICATION.
<br />2. THIS WARRANTY COVERS ALL FABRICATION AND INSTALLATION PERFORMED BY THE CERTIFIED/APPROVED SOURCE SUBJECT
<br />TO THE SPECIFIC WORDING CONTAINED IN THE INSTALLED WARRANTY CARD.
<br />C. MANUFACTURER'S WARRANTY PERIOD:
<br />1. TEN YEARS FROM DATE OF SUBSTANTIAL COMPLETION.
<br />1.4 MAINTENANCE: PROVIDE MAINTENANCE REQUIREMENTS AS SPECIFIED BY THE MANUFACTURER
<br />1.5 SOLID SURFACE COUNTERTOP COMPONENTS
<br />A. CONFIGURATION: PROVIDE COUNTERTOPS WITH THE FOLLOWING FRONT AND BACKSPLASH STYLE:
<br />1. FRONT:
<br />a. SLIGHTLY EASED AT EXPOSED EDGES WITH 1-1/2" HIGH FACE
<br />b. NO -DRIP PROFILE AT TOP EDGE WITH 1-1/2" HIGH FACE, UNLESS NOTED OTHERWISE ON DRAWINGS.
<br />2. BACKSPLASH AND SIDESPLASH:
<br />a. SLIGHTLY EASED AT EXPOSED CORNERS AND EDGES.
<br />B. COUNTERTOPS: 1/2-INCH THICK, SOLID SURFACE MATERIAL LAMINATED TO 3/4-INCH THICK PARTICLEBOARD WITH EXPOSED
<br />EDGES BUILT UP WITH 1/2-INCH THICK, SOLID SURFACE MATERIAL.
<br />C. BACKSPLASHES: 3/4-INCH THICK, SOLID SURFACE MATERIAL.
<br />1.6 MATERIALS
<br />A. CERTIFIED WOOD MATERIALS: FABRICATE COUNTERTOPS WITH WOOD AND WOOD -BASED PRODUCTS PRODUCED FROM WOOD
<br />OBTAINED FROM FORESTS CERTIFIED BY AN FSC-ACCREDITED CERTIFICATION BODY TO COMPLY WITH FSC STD-01-001, "FSC
<br />PRINCIPLES AND CRITERIA FOR FOREST STEWARDSHIP."
<br />B. COMPOSITE WOOD AND AGRIFIBER PRODUCTS: PROVIDE PRODUCTS THAT COMPLY WITH THE TESTING AND PRODUCT
<br />REQUIREMENTS OF THE CALIFORNIA DEPARTMENT OF HEALTH SERVICES""STANDARD PRACTICE FOR THE TESTING OF VOLATILE
<br />ORGANIC EMISSIONS FROM VARIOUS SOURCES USING SMALL-SCALE ENVIRONMENTAL CHAMBERS," INCLUDING 2004 ADDENDA.
<br />C. PARTICLEBOARD: ANSI A208.1, GRADE M-2, MADE WITH BINDER CONTAINING NO UREA FORMALDEHYDE.
<br />D. ADHESIVES: ADHESIVES SHALL COMPLY WITH THE TESTING AND PRODUCT REQUIREMENTS OF THE CALIFORNIA DEPARTMENT
<br />OF HEALTH SERVICES' "STANDARD PRACTICE FOR THE TESTING OF VOLATILE ORGANIC EMISSIONS FROM VARIOUS SOURCES
<br />USING SMALL-SCALE ENVIRONMENTAL CHAMBERS."
<br />1. JOINT ADHESIVE: MANUFACTURER'S STANDARD ONE- OR TWO-PART ADHESIVE KIT TO CREATE INCONSPICUOUS, NONPOROUS
<br />JOINTS.
<br />2. SEALANT: MANUFACTURER'S STANDARD MILDEW -RESISTANT, FDA -COMPLIANT, NSF 51-COMPLIANT (FOOD ZONE -ANY TYPE),
<br />UL-LISTED SILICONE SEALANT IN COLORS MATCHING COMPONENTS.
<br />3. SINK MOUNTING HARDWARE: MANUFACTURER'S STANDARD BOWL CLIPS, PANEL INSERTS AND FASTENERS FOR ATTACHMENT
<br />OF UNDERMOUNT SINKS.
<br />E. SOLID SURFACE MATERIAL: HOMOGENEOUS -FILLED PLASTIC RESIN COMPLYING WITH ICPA SS-1.
<br />1. MANUFACTURER: REFER TO FINISH SCHEDULE ON DRAWINGS.
<br />2. INTEGRAL SINK BOWLS: COMPLY WITH ISSFA-2 AND ANSI Z124.3, TYPE 5 OR TYPE 6, WITHOUT A PRECOATED FINISH.
<br />a. MODEL: REFER TO FINISH SCHEDULE ON DRAWINGS.
<br />3. COLOR AND PATTERNS:
<br />a. COUNTERTOPS: REFER TO FINISH SCHEDULE ON DRAWINGS.
<br />b. INTEGRAL SINKS: REFER TO FINISH SCHEDULE ON DRAWINGS.
<br />F. SHAPES MEET OR EXCEED THE ANSI Z124.3 AND ANSI Z124.6 STANDARDS FOR PLASTIC SINKS AND LAVATORIES.
<br />1.7 EXAMINATION
<br />A. EXAMINE SUBSTRATES AND CONDITIONS, WITH FABRICATOR PRESENT FOR COMPLIANCE WITH REQUIREMENTS FOR
<br />INSTALLATION TOLERANCES AND OTHER CONDITIONS AFFECTING PERFORMANCE OF WORK.
<br />B. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED.
<br />1.8 INSTALLATION
<br />A. INSTALL COMPONENTS PLUMB, LEVEL AND RIGID, SCRIBED TO ADJACENT FINISHES, IN ACCORDANCE WITH APPROVED SHOP
<br />DRAWINGS AND PRODUCT DATA.
<br />1. PROVIDE PRODUCT IN THE LARGEST PIECES AVAILABLE.
<br />2, FORM FIELD JOINTS USING MANUFACTURER'S RECOMMENDED ADHESIVE, WITH JOINTS INCONSPICUOUS IN FINISHED WORK.
<br />a. EXPOSED JOINTS/SEAMS SHALL NOT BE ALLOWED.
<br />3. REINFORCE FIELD JOINTS WITH SOLID SURFACE STRIPS EXTENDING A MINIMUM OF 1 INCH ON EITHER SIDE OF THE SEAM WITH
<br />THE STRIP BEING THE SAME THICKNESS AS THE TOP.
<br />4. CUT AND FINISH COMPONENT EDGES WITH CLEAN, SHARP RETURNS.
<br />5. ROUT RADII AND CONTOURS TO TEMPLATE.
<br />6, ANCHOR SECURELY TO BASE CABINETS OR OTHER SUPPORTS.
<br />7. ALIGN ADJACENT COUNTERTOPS AND FORM SEAMS TO COMPLY WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS USING
<br />ADHESIVE IN COLOR TO MATCH COUNTERTOP,
<br />8. CAREFULLY DRESS JOINTS SMOOTH, REMOVE SURFACE SCRATCHES AND CLEAN ENTIRE SURFACE.
<br />9. INSTALL COUNTERTOPS WITH NO MORE THAN 1/8-INCH (3 MM) SAG, BOW OR OTHER VARIATION FROM A STRAIGHT LINE.
<br />B. APPLIED BACKSPLASHES AND SIDESPLASHES:
<br />1. INSTALL APPLIED SIDESPLASHES USING MANUFACTURER'S STANDARD COLOR -MATCHED SILICONE SEALANT,
<br />2. ADHERE APPLIED SIDESPLASHES TO COUNTERTOPS USING MANUFACTURER'S STANDARD COLORMATCHED SILICONE
<br />SEALANT. C. INTEGRAL SINKS:
<br />3, PROVIDE SOLID SURFACE MATERIALS BOWLS AND/OR LAVATORIES SINKS WITH OVERFLOWS IN LOCATIONS SHOWN ON THE
<br />DRAWINGS.
<br />4. SECURE SINKS AND LAVATORY BOWLS TO TOPS USING MANUFACTURER'S RECOMMENDED SEALANT, ADHESIVE AND
<br />MOUNTING HARDWARE TO MAINTAIN WARRANTY.
<br />1.9 REPAIR
<br />A. REPAIR OR REPLACE DAMAGED WORK WHICH CANNOT BE REPAIRED TO ARCHITECT'S SATISFACTION.
<br />1.10 CLEANING AND PROTECTION
<br />A. KEEP COMPONENTS CLEAN DURING INSTALLATION.
<br />B. REMOVE ADHESIVES, SEALANTS AND OTHER STAINS.
<br />s
<br />e� 10 Ras
<br />s m>
<br />170E if " ' Drive
<br />6 :3 ¢
<br />Tampa, #{'lipt-".3'P �.;'`,�`�0•,
<br />°AA333
<br />A!! reproduction & inteliectua6 property
<br />rights reserved 2017
<br />Project
<br />Fiavita
<br />ZEI!►` _ -
<br />FL 33542
<br />Prepared for
<br />DAVITA MEDICAL GROUP
<br />In Assoriat!Cn with.
<br />CONTACT: KARL HEES
<br />1381 51 H ST
<br />SARASOTA, FL 34236
<br />PHONE: 941.955.4555
<br />GENESIS ENGINEER GROUP, LLC
<br />CONTACT: MIKE HANEY
<br />1000 N. ASH. LEY CJR. #9001
<br />TAMPA, FL
<br />PHONE: 813,523,6455
<br />GENESIS ENGINEER GROUP, LLC
<br />CONTACT. MICE ;-IANEY
<br />1000 N. ASHLEY DR. #90-01 FL
<br />PHONE: 813,523.6455
<br />��Andrew J. Dohmen, A:=- # 12.11012_10 18
<br />15605 11:22:44 AM
<br />No. Revision Description Date
<br />1 PERMIT AND BID SET 12/10/2018
<br />No. Revision Desortstlon Date
<br />Draw i By: ,+nu; Checked By: ;'?C
<br />('noiect Number:
<br />Sheet Titie
<br />Orlgina', drawing is 24 x 36 Dc not
<br />scale curitefits of drawing
<br />Sheet Number
<br />
|