<br />SECTION 084113 - ALUMINUM -FRAMED ENTRANCES AND STOREFRONTS (CONTINUED)
<br />B. INTERIOR FRAMING MEMBERS.
<br />1, SYSTEM AND FINISH. AS SCHEDULED ON DRAWINGS
<br />2, MANUFACTURER'S EXTRUDED ALUMINUM FRAMING MEMBERS OF THICKNESS REQUil AND REINFORCED AS REQUIRED TO
<br />SUPPORT IMPOSED LOADS.
<br />3, FABRICATION METHOD: FACTORY FABRICATED AND SHIPPED KNOCKDOWN FOR INSTALLATION BY THE GLAZING SUB-
<br />CONTRACTOR.
<br />C. BACKER PLATES: MANUFACTURER'S STANDARD, CONTINUOUS BACKER PLATES FOR FRAMING MEMBERS, IF NOT INTEGRAL,
<br />WHERE FRAMING ABUTS ADJACENT CONSTRUCTION,
<br />D. BRACKETS AND REINFORCEMENTS: MANUFACTURER'S STANDARD HIGH -STRENGTH ALUMINUM WITH NONSTAINING,
<br />NONFERROUS SHIMS FOR ALIGNING SYSTEM COMPONENTS.
<br />E. SILL PLATES AND FLASHINGS: PROVIDE SILL PLATES, FLASHINGS AND FLASHING ACCESSORIES TO ACCOMMODATE POSITIVE
<br />DRAINAGE AND SILL PROTECTION AT GLAZED OPENINGS. REFER TO ARCHITECTURAL DRAWINGS.
<br />F. MATERIALS:
<br />1. ALUMINUM: ALLOY AND TEMPER RECOMMENDED BY MANUFACTURER FOR TYPE OF USE AND FINISH INDICATED.
<br />a. SHEET AND PLATE: ASTM B 209.
<br />b. EXTRUDED BARS, RODS, PROFILES, AND TUBES: ASTM B 221.
<br />c. EXTRUDED STRUCTURAL PIPE AND TUBES: ASTM B 429/13 429M.
<br />d. STRUCTURAL PROFILES: ASTM B 308/B 308M.
<br />2. STEEL REINFORCEMENT: MANUFACTURER'S STANDARD ZINC -RICH, CORROSION -RESISTANT PRIMER COMPLYING WITH SSPC
<br />PS GUIDE NO. 12.00; APPLIED IMMEDIATELY AFTER SURFACE PREPARATION AND PRETREATMENT. SELECT SURFACE
<br />PREPARATION METHODS ACCORDING TO RECOMMENDATIONS IN SSPC-SP COM, AND PREPARE SURFACES ACCORDING TO
<br />APPLICABLE SSPC STANDARD.
<br />a. STRUCTURAL SHAPES, PLATES, AND BARS: ASTM A 36,A 36M.
<br />b. COLD -ROLLED SHEET AND STRIP: ASTM A 1008A 10081\1,
<br />c. HOT -ROILED SHEET AND STRIP: iaSTM A 10??/A 1011Ps.
<br />1.10 ENTRANCE DOUR SYSTEMS
<br />A. MANUFACTURERS FACTURERS STAD R N A : ENTRANCr
<br />E DOOR.
<br />1 BASS OF DESIrNn. S SCHED ON CPAVINCS
<br />.
<br />2. DOOR CONSTRUCTION: 1-314-INCH OVERALL THICKNESS, WITH MINIMUM 0.125-INCH THICK, EXTRUDED -ALUMINUM TUBULAR
<br />RAIL AND STILE MEMBERS. MECHANICALLY FASTEN CORNERSVd{TH REINFORCING BRACKETS THAT ARE DEEPLY PENETRATED
<br />AND FILLET VtfELDED OR THAT INCORPORATE CONCEALED TIE RODS,
<br />3. DOOR. DESIGN:
<br />a. NC-D!UPA STILE; 3-1/ !NCH NOi'AINAL WIDTH.
<br />b. 10 INCH NOMINAL 80TTOM RAIL.
<br />4. GLAZING:
<br />a. INTERIOR LOCATIONS: 3/8 INCH CLEAR TEMPERED GLAZING, UNLESS NCTED EXTERIOR AND VESTIBULE DOORS: 1 INCH
<br />CLEAR INSULATED GLASS UNIT, UNLESS NOTED OTHERWISE.
<br />b, REFER TO SECTION 088000 "GLAZING".
<br />5. GLAZING STOPS AND GASKETS: BEVELED AT THE STILES AND SQUARE AT THE RAILS SNAP -ON, EXTRUDED -ALUMINUM
<br />STOPS AND PREFORMED GASKETS.
<br />a. PROVIDE NON -REMOVABLE GLAZING STOPS ON OUTSIDE OF DOOR.
<br />1.11 ENTRANCE DOOR HARDWARE
<br />A. DOOR HARDWARE: HARDWARE IS SPECIFIED IN SECTION 087100 "DOOR HARDWARE" AND AS SCHEDULED ON THE DRAWINGS.
<br />1. SUBSTITUTIONS NOT PERMITTED.
<br />B. COORDINATION:
<br />1, DAVITA DOOR HARDWARE VENDOR (LOCKNET) TO PROVIDE AUTOMATIC OPERATORS AND PUSH PLATE HARDWARE ONLY,
<br />UNLESS COORDINATED OTHERWISE, INSTALLATION COORDINATED BY GENERAL CONTRACTOR,
<br />2. ALL OTHER HARDWARE TO BE SUPPLIED BY ALUMINUM STOREFRONT MANUFACTURER.
<br />3, COORDINATE ALTERNATIVE DOOR HARDWARE PROVISIONS WITH DAVITA DOOR HARDWARE VENDOR.
<br />C. GENERAL: PROVIDE DOOR HARDWARE INDICATED IN THE'DOOR HARDWARE SCHEDULE" ON DRAWINGS FOR EACH
<br />ENTRANCE DOOR, COMPLY WITH REQUIREMENTS IN THIS SECTION.
<br />1. DOOR HARDWARE SETS: PROVIDE QUANTITY, ITEM, SIZE, FINISH OR COLOR INDICATED, AND NAMED MANUFACTURERS'
<br />PRODUCTS,
<br />2. SEQUENCE OF OPERATION: PROVIDE ELECTRIFIED DOOR HARDWARE FUNCTION, SEQUENCE OF OPERATION, AND
<br />INTERFACE WITH OTHER BUILDING CONTROL SYSTEMS INDICATED.
<br />3, OPENING -FORCE REQUIREMENTS:
<br />a. EGRESS DOORS: NOT MORE THAN 15 LBF TO RELEASE THE LATCH AND NOT MORE THAN 30 LBF TO SET THE DOOR IN MOTION
<br />AND NOT MORE THAN 15 LBF TO OPEN THE DOOR TO ITS MINIMUM REQUIRED WIDTH.
<br />b. ACCESSIBLE INTERIOR DOORS: NOT MORE THAN 5 LBF TO FULLY OPEN DOOR.
<br />D. DESIGNATIONS: REQUIREMENTS FOR DESIGN, GRADE, FUNCTION, FINISH, SIZE, AND OTHER DISTINCTIVE QUALITIES OF EACH
<br />TYPE OF ENTRANCE DOOR HARDWARE ARE INDICATED IN "ENTRANCE DOOR HARDWARE SETS" ARTICLE. PRODUCTS ARE
<br />IDENTIFIED BY USING ENTRANCE DOOR HARDWARE DESIGNATIONS AS FOLLOWS:
<br />1. NAMED MANUFACTURERS' PRODUCTS: MANUFACTURER AND PRODUCT DESIGNATION ARE LISTED FOR EACH DOOR
<br />HARDWARE TYPE REQUIRED FOR THE PURPOSE OF ESTABLISHING MINIMUM REQUIREMENTS. MANUFACTURERS' NAMES ARE
<br />ABBREVIATED IN "ENTRANCE DOOR HARDWARE SETS" ARTICLE.
<br />2 REFERENCES TO BHMA STANDARDS: PROVIDE PRODUCTS COMPLYING WITH THESE STANDARDS AND REQUIREMENTS FOR
<br />DESCRIPTION, QUALITY, AND FUNCTION.
<br />112 GLAZING
<br />A. GLAZING: COMPLY WITH SECTION 038000 "GLAZING."
<br />B. GLAZING GASKETS: MANUFACTURER'S STANDARD SEALED -CORNER PRESSURE -GLAZING SYSTEM( OF BLACK, RESILIENT
<br />ELASTOMERIC GLAZING GASKETS, SETTING BLOCKS, AND SHIMS OR SPACERS.
<br />C. GLAZING SEALANTS: AS RECOMMENDED BY MANUFACTLiRER.
<br />D. SEALANTS USED INSIDE THE WEATHERPROOFING SYSTEM SHALL HAVE A VOO CONTENT OF 250 GIL.
<br />1.13 FABRICATION
<br />A. FABRICATION OF MATERIAL APJD SYSTEM TO 3E BY MAtdL;F,= CrURER.
<br />B. FORM OR EXTRUDE ALUMINUM SHAPES BEFORE ! IN!SHING.
<br />C. WELL) IN CONCEALED LOCATIONS TO GREATEST EXTENT POSSIBLE TO AMMiZE DISTORTION OR DISCOLORATION OF FINISH.
<br />REMOVE WELD SPATTER AiND WELDING OXIDES FROM EXPOSED SURFACES BY DESCALING OR GRINDING.
<br />D. FABRICATE COMPONENTS THAT, WHEN ASSEMBLED, HAVE THE FOLLOV'IiNG CHARACTERISTICS:
<br />1. PROF iLEES THAT ARE SHARP, STRA.IGHT.AND FREE OF DEFECTS OR DEFORMATIONS.
<br />2. ACCURATELY FITTED JOINTS WITH ENDS COPED OR MITERED.
<br />3. PHYSICAL AND THERMAL ISOLATION OF GLAZING FROM FRAMING MEMBERS.
<br />4. ACCOMMODATIONS FOR THERMAL AND MECHANICAL MOVEMENTS OF GLAZING AND FRAMING TO MAINTAIN REQUIRED
<br />GLAZING EDGE CLEARANCES.
<br />5. PROVISIONS FOR FIELD REPLACEMENT OF GLAZING FROM EXTERIOR.
<br />6. FAST, ENERS, ANCHORS, AND CONNECTION DEVICES THAT ARE CONCEALED FROM VIEWTO GREATEST EXTENT POSSIBLE.
<br />E. MECI-lAMCALLY GLAZED FRAMING MIEMBERS: FABRICATE FOR FLUSH GLAZING WITHOUT PROJECTING STOPS.
<br />F. ENTRANCE DOOR FRAMES: REINFORCE AS REQUIRED TO SUPPORT LOADS IMPOSED BY DOOR OPERATION AND FOR
<br />INSTALLING ENTRANCE DOOR HARDWARE.
<br />G. ENTRANCE DOORS: REINFORCE DOORS AS REQUIRED FOR INSTALLING ENTRANCE DOOR HARDWARE.
<br />H. ENTRANCE DOOR HARDWARE INSTALLATION: FACTORY INSTALL ENTRANCE DOOR HARDWARE TO THE GREATEST EXTENT
<br />POSSIBLE, CUT, DRILL, AND TAP FOR FACTORY -INSTALLED ENTRANCE DOOR HARDWARE BEFORE APPLYING FINISHES.
<br />I. AFTER FABRICATION, CLEARLY MARK COMPONENTS TO IDENTIFY THEIR LOCATIONS IN PROJECT ACCORDING TO SHOP
<br />DRAWINGS.
<br />1.14 ALUMINUM FINISHES
<br />A. CLASS 1 CLEAR ANODIC FINISH: EXTERIOR STOREFRONT FRAMING AND ACCESSORIES.
<br />B. CLASS 2 CLEAR ANODIC FINISH: INTERIOR STOREFRONT FRAMING.
<br />1.15 INSTALLATION
<br />A. GENERAL:
<br />1, COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
<br />2. DO NOT INSTALL DAMAGED COMPONENTS.
<br />3. FIT JOINTS TO PRODUCE HAIRLINE JOINTS FREE OF BURRS AND DISTORTION.
<br />4. RIGIDLY SECURE NON -MOVEMENT JOINTS.
<br />5. INSTALL ANCHORS WITH SEPARATORS AND ISOLATORS TO PREVENT METAL CORROSION AND ELECTROLYTIC
<br />DETERIORATION AND TO PREVENT IMPEDING MOVEMENT OF MOVING JOINTS.
<br />6. SEAL PERIMETER AND OTHER JOINTS WATERTIGHT UNLESS OTHERWISE INDICATED.
<br />B. METAL PROTECTION:
<br />1. WHERE ALUMINUM IS IN CONTACT WITH DISSIMILAR METALS, PROTECT AGAINST GA.LVA,NIC ACTION 8Y PAINTING CONTACT
<br />SURFACES WITH MATERIALS RECOMMENDED BY MAMJFACTt1RER FOR THIS PURPOSE OR SY INSTALLING NONCONDUCTIVE
<br />SPACERS.
<br />2, INHERE .ALUMINUPP IS !N CONTACT WITH CONCRETE OR MASONRY, PROTECT AGAINST CORROSION By PAINTING CONTACT
<br />SURFACES WITH BITUMINOUS PAINT.
<br />C. USE CCNJTRNUOUS, FULL DEPTH AUJPJiP>IUMISILLS WITH VERTICAL LEG AT INTERIOR FACE AND P,NGLED DRIP EDGE AT
<br />EXTERIOR.
<br />1, SET SILL MEMBERS AND FLASHING IN FULL SEALA14T BED AS SPECIFIED IN SECTION 079200 "JOINT SEALANTS" TO PRODUCE
<br />WE.ATHERTIGHT INSTALLATION.
<br />D. INSTALL COMPONENTS PLUMB AND TRUE IN ALIGNMENT WITH ESTABLISHED LINES AND GRADES.
<br />E. INSTALL GLAZING AS SPECIFIED IN SECTION 088000 "GLAZING."
<br />F ENTRANCE DOORS: INSTALL DOORS TO PRODUCE SMOOTH OPERATION Al TIGHT FIT AT CONTACT POINTS.
<br />i. EXTERIOR DOORS: iNSTA.LL TO PRODUCE VVEA. T HER T iGHT EPNCLOSIRE .AND TIGHT FIT AT WEATHER STRIPPING
<br />2. INTERIOR DOORS: INSTALL CONTINUOUS SILENCERS ALONG FRAME.
<br />3. FIELD -INSTALLED ENTRANCE DOOR HARDWARE: INSTALL SURFACE -MOUNTED ENTRANCE DOOR HARDWARE ACCORDING TO
<br />ENTRANCE DOOR HARDWARE MANUFACTURERS' WRITTEN INSTRUCTIONS USING CONCEALED FASTENERS TO GREATEST
<br />EXTENT POSSIBLE.
<br />SECTION 087100 - DOOR HARDWARE
<br />1.1 SUMMARY
<br />A. THIS SECTION INCLUDES COMMERCIAL DOOR HARDWARE FOR SWINGING DOORS,
<br />B. DOOR HARDWARE INCLUDES, BUT IS NOT NECESSARILY LIMITED TO, THE FOLLOWING:
<br />1. MECHANICAL DOOR HARDWARE.
<br />2. ELECTROMECHANICAL DOOR HARDWARE, POWER SUPPLIES, BACK-UPS AND SURGE PROTECTION.
<br />3. AUTOMATIC OPERATORS.
<br />4. CYLINDERS SPECIFIED FOR DOORS IN OTHER SECTIONS.
<br />C. RELATED SECTIONS
<br />1. DIVISION 08 SECTION "HOLLOW METAL DOORS AND FRAMES".
<br />2. DIVISION 08 SECTION "ALUMINUM -FRAMED ENTRANCES AND STOREFRONTS".
<br />3. DIVISION 08 SECTION "CLAD WOOD DOORS".
<br />D. STANDARDS: ALL HARDWARE SPECIFIED HEREIN SHALL COMPLY WITH THE FOLLOWING INDUSTRY STANDARDS:
<br />1. ANSI/BHMA CERTIFIED PRODUCT STANDARDS - A156 SERIES
<br />2. UL10C - POSITIVE PRESSURE FIRE TESTS OF DOOR ASSEMBLIES
<br />1.2 SUBMITTALS
<br />A. REFER TO SECTION 013300 FOR SUBMITTAL REQUIREMENTS.
<br />B. PRODUCT DATA: MANUFACTURER'S PRODUCT DATA SHEETS INCLUDING INSTALLATION DETAILS, MATERIAL DESCRIPTIONS,
<br />DIMENSIONS OF INDIVIDUAL COMPONENTS AND PROFILES, OPERATIONAL DESCRIPTIONS AND FINISHES.
<br />C. DOOR HARDWARE SCHEDULE: PREPARED BY OR UNDER THE SUPERVISION OF SUPPLIER, DETAILING FABRICATION AND
<br />ASSEMBLY OF DOOR HARDWARE, AS WELL AS PROCEDURES AND DIAGRAMS, COORDINATE THE FINAL DOOR HARDWARE
<br />SCHEDULE WITH DOORS, FRAMES, AND RELATED WORK TO ENSURE PROPER SIZE, THICKNESS, HAND, FUNCTION, AND FINISH
<br />OF DOOR HARDWARE.
<br />D. OPERATING AND MAINTENANCE MANUALS: PROVIDE MANUFACTURERS OPERATING AND MAINTENANCE MANUALS FOR EACH
<br />ITEM COMPRISING THE COMPLETE DOOR HARDWARE INSTALLATION IN QUANTITY AS REQUIRED IN DIVISION 01, CLOSEOUT
<br />SUBMITTALS. THE IVANUAL TO INCLUDE THE NAME, ADDRESS, AND CONTACT INFORMATION OF THE MANUFACTURERS
<br />PROVIDING THE HARDWARE AND THEIR NEAREST SERVICE REPRESENTATIVES. THE FINAL COPIES DELIVERED AFTER
<br />COMPLETION OF THE INSTALLATION TEST TO INCLUDE "AS BUILT" MODIFICATIONS MADE DURING INSTALLATION, CHECKOUT,
<br />D
<br />.AND ACCEPTANCE
<br />TANCE
<br />E. WARRANTIES AND MAINTENANCE: SPECIAL WARRANTIES AND MAINTENANCE AGREEMENTS SPECIFIED IN THIS SECTION.
<br />1.3 QUALITY ASSURANCE
<br />A. MANUFACTURERS QUALIFICATIONS: ENGAGE QUALIFIED MANUFACTURERS WITH A MINIMUM 5 YEARS OF DOCUMENTED
<br />EXPERIENCE IN PRODUCING HARDWARE AND EQUIPMENT SIMILAR TO THAT INDICATED FOR THIS PROJECT AND THAT HAVE A
<br />PROVEN RECORD OF SUCCESSFUL IN-SERVICE PERFORMANCE.
<br />B. INSTALLER QUALIFICATIONS: INSTALLERS, TRAINED BY THE PRIMARY PRODUCT MANUFACTURERS, WITH A MINIMUM 3
<br />YEARS DOCUMENTED EXPERIENCE INSTALLING BOTH STANDARD AND ELECTRIFIED BUILDERS HARDWARE SIMILAR IN
<br />MATERIAL, DESIGN, AND EXTENT TO THAT INDICATED FOR THIS PROJECT AND WHOSE WORK HAS RESULTED IN CONSTRUCTION
<br />WITH A RECORD OF SUCCESSFUL IN-SERVICE PERFORMANCE.
<br />C. SOURCE LIMITATIONS: OBTAIN EACH TYPE AND VARIETY OF DOOR HARDWARE SPECIFIED IN THIS SECTION FROM A SINGLE
<br />SOURCE, QUALIFIED SUPPLIER UNLESS OTHERWISE INDICATED.
<br />D. REGULATORY REQUIREMENTS: COMPLY WITH NFPA 70, NFPA 8Q NFPA 101 AND ANSI A117.1 REQUIREMENTS AND
<br />GUIDELINES AS DIRECTED IN THE MODEL BUILDING CODE.
<br />E. EACH UNIT TO BEAR THIRD PARTY PERMANENT LABEL DEMONSTRATING COMPLIANCE WITH THE REFERENCED STANDARDS.
<br />F. KEYING: GC TO COORDINATE KEYING WITH OWNER.
<br />G. PRE -SUBMITTAL CONFERENCE CALL: AS REQUIRED, CONDUCT COORDINATION CONFERENCE CALL WITH ATTENDANCE BY
<br />REPRESENTATIVES OF SUPPLIER(S), INSTALLER(S), AND CONTRACTOR(S) TO REVIEW PROPER METHODS AND THE
<br />PROCEDURES FOR RECEIVING, HANDLING, AND INSTALLING DOOR HARDWARE.
<br />H. AT COMPLETION OF INSTALLATION, PROVIDE WRITTEN DOCUMENTATION THAT COMPONENTS WERE APPLIED TO
<br />MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS AND ACCORDING TO APPROVED SCHEDULE.
<br />1.4 DELIVERY, STORAGE, AND HANDLING
<br />A. INVENTORY DOOR HARDWARE ON RECEIPT AND PROVIDE SECURE LOCK -UP AND SHELVING FOR DOOR HARDWARE
<br />DELIVERED TO PROJECT SITE. DO NOT STORE ELECTRONIC ACCESS CONTROL HARDWARE, SOFTWARE OR ACCESSORIES AT
<br />PROJECT SITE WITHOUT PRIOR AUTHORIZATION.
<br />B. TAG EACH ITEM OR PACKAGE SEPARATELY WITH IDENTIFICATION RELATED TO THE FINAL DOOR HARDWARE SCHEDULE,
<br />AND INCLUDE BASIC INSTALLATION INSTRUCTIONS WITH EACH ITEM OR PACKAGE.
<br />C. DELIVER, AS APPLICABLE, PERMANENT KEYS, CYLINDERS, CORES, ACCESS CONTROL CREDENTIALS, SOFTWARE AND
<br />RELATED ACCESSORIES DIRECTLY TO OWNER VIA REGISTERED MAIL OR OVERNIGHT PACKAGE SERVICE. INSTRUCTIONS FOR
<br />DELIVERY TO THE OWNER SHALL BE ESTABLISHED AT THE "KEYING CONFERENCE".
<br />15 COORDINATION
<br />A. TEMPLATES: OBTAIN AND DISTRIBUTE TO THE PARTIES INVOLVED TEMPLATES FOR DOORS, FRAMES, AND OTHER WORK
<br />SPECIFIED TO BE FACTORY PREPARED FOR INSTALLING STANDARD AND ELECTRIFIED HARDWARE. CHECK SHOP DRAWINGS OF
<br />OTHER WORK TO CONFIRM THAT ADEQUATE PROVISIONS ARE MADE FOR LOCATING AND INSTALLING HARDWARE TO COMPLY
<br />WITH INDICATED REQUIREMENTS.
<br />S. DOOR HARDWARE AND ELECTRICAL CONNECTIONS: COORDINATE THE LAYOUT AND INSTALLATION OF SCHEDULED
<br />ELECTRIFIED DOOR HARDWARE AND RELATED ACCESS CONTROL EQUIPMENT WITH REQUIRED CONNECTIONS TO SOURCE
<br />POWER JUNCTION BOXES, LOW VOLTAGE POWER SUPPLIES, DETECTION AND MONITORING HARDWARE, AND FIRE AND
<br />DETECTION ALARM SYSTEMS.
<br />C. DOOR AND FRAME PREPARATION: RELATED DIVISION 08 SECTIONS (STEEL, ALUMINUM AND WOOD) DOORS AND
<br />CORRESPONDING FRAMES ARE TO BE PREPARED, REINFORCED AND PRE -WIRED (IF APPLICABLE) TO RECEIVE THE
<br />INSTALLATION OF THE SPECIFIED ELECTRIFIED, MONITORING, SIGNALING AND ACCESS CONTROL SYSTEM HARDWARE WITHOUT
<br />ADDITIONAL IN -FIELD MODIFICATIONS.
<br />1.6 WARRANTY
<br />A. GENERAL WARRANTY: REFERENCE DIVISION Ot, GENERAL REQUIREMENTS. SPECIAL WARRANTIES SPECIFIED IN THIS
<br />ARTICLE SHALL NOT DEPRIVE OWNER OF OTHER RIGHTS OWNER MAY HAVE UNDER OTHER PROVISIONS OF THE CONTRACT
<br />DOCUMENTS AND SHALL BE IN ADDITION TO, AND RUN CONCURRENT WITH, OTHER WARRANTIES MADE BY CONTRACTOR LINDER
<br />REQUIREMENTS OF THE CONTRACT DOCUMENTS.
<br />B WARRANTY PERIOD: WRITTEN WARRANTY, EXECUTED BY MANUFACTURER(S), AGREEING TO REPAIR OR REPLACE
<br />COMPONENTS OF STANDARD AND ELECTRIFIED DOOR HARDWARE THAT FAILS IN MATERIALS OR WORKMANSHIP WITHIN
<br />SPECIFIED WARRANTY PERIOD AFTER FINAL ACCEPTANCE BY THE OWNER. FAILURES INCLUDE, BUT ARE NOT LIMITED TO, THE
<br />FOLLOWING:
<br />1. STRUCTURAL FAILURES INCLUDING EXCESSIVE DEFLECTION, CRACKING, OR BREAKAGE.
<br />2. FAULTY OPERATION OF THE HARDWARE.
<br />3 DETERIORATION OF METALS, METAL FINISHES, AND OTHER MATERIALS BEYOND NORMAL WEATHERING,
<br />4. ELECTRICAL COMPONENT D AND FAILURES WITHIN THE SYSTEMS OPERATION.
<br />E T DEFECTS A
<br />C. S T ANDARD WARRANTY PERIOD: YEAR FROM DATE OF SUBSTANTIAL COMPLETION UNLESS OTHERWISE INDICATED.
<br />0 ONE
<br />D. SPECIAL WARRANTY PERIODS:
<br />1. TEN YEARS F . OR MORTISE LOCKS AND LATHES.
<br />2. FIVE YEARS FOR EXIT HARDWARE.
<br />3. TWENTY FIVE YEARS FOR MANUAL SURFACE DOOR CLOSERS.
<br />4. TWO YEARS FOR ELECTROMECHANICAL DOOR HARDWARE.
<br />1.7 MAINTENANCE SERVICE
<br />A. MAINTENANCE TOOLS AND INSTRUCTIONS: FURNISH A COMPLETE SET OF SPECIALIZED TOOLS AND MAINTENANCE
<br />INSTRUCTIONS AS NEEDED FOR OWNER'S CONTINUED ADJUSTMENT, MAINTENANCE, AND REMOVAL AND REPLACEMENT OF
<br />DOOR HARDWARE.
<br />B. CONTINUING SERVICE: BEGINNING AT SUBSTANTIAL COMPLETION, AND RUNNING CONCURRENT WITH THE SPECIFIED
<br />WARRANTY PERIOD, PROVIDE CONTINUOUS (6) MONTHS FULL MAINTENANCE INCLUDING REPAIR AND REPLACEMENT OF WORN
<br />OR DEFECTIVE COMPONENTS, LUBRICATION, CLEANING, AND ADJUSTING AS REQUIRED FOR PROPER DOOR OPENING
<br />OPERATION. PROVIDE PARTS AND SUPPLIES AS USED IN THE MANUFACTURE AND INSTALLATION OF ORIGINAL PRODUCTS.
<br />1.8 SCHEDULED DOOR HARDWARE
<br />A. GENERAL: PROVIDE DOOR HARDWARE FOR EACH DOOR TO COMPLY WITH REQUIREMENTS IN DOOR HARDWARE SETS AND
<br />EACH REFERENCED SECTION THAT PRODUCTS ARE TO BE SUPPLIED UNDER.
<br />1. DESIGNATIONS: REQUIREMENTS FOR QUANTITY, ITEM, SIZE, FINISH OR COLOR, GRADE, FUNCTION, AND OTHER DISTINCTIVE
<br />QUALITIES OF EACH TYPE OF DOOR HARDWARE ARE INDICATED IN THE DOOR HARDWARE SETS. PRODUCTS ARE IDENTIFIED BY
<br />USING DOOR HARDWARE DESIGNATIONS.
<br />B. NAMED MANUFACTURER'S PRODUCTS: PRODUCT DESIGNATION AND MANUFACTURER ARE LISTED FOR EACH DOOR
<br />HARDWARE TYPE REQUIRED FOR THE PURPOSE OF ESTABLISHING REQUIREMENTS. MANUFACTURERS' NAMES ARE
<br />ABBREVIATED IN THE DOOR HARDWARE SCHEDULE.
<br />1. ACCEPTABLE PRODUCTS/MANUFACTURERS: REFER TO DOOR HARDWARE SCHEDULE ON DRAWINGS.
<br />1.9 HANGING DEVICES
<br />A HINGES: ANSI/BHMP, A156.1 CERTIFIED BUTT HINGES WITH NUMBER OF HINGE KNUCKLES AS SPECIFIED IN THE DOOR
<br />HARDWARE SETS.
<br />B. CONTINUOUS GEARED HINGES: ANSI/BHMA A156.26 CERTIFIED CONTINUOUS GEARED HINGE WITH MINIMUM 0.120-INCH THICK
<br />EXTRUDED 6060 T6 ALUMINUM ALLOY HINGE LEAVES AND A MINIMUM OVERALL WIDTH OF 4 INCHES.
<br />1.10 DOOROPER.ATINGTRIM
<br />A. FLUSH BOLTS AND SURFACE BOLTS: ANSI/BHMA A156.3 AND A156.16, GRADE 1, CERTIFIED AUTOMA71iC, SELF -LATCHING, AND
<br />MANUAL FLUSH BOLTS AND SURFACE BOLTS.
<br />1.11 CYLINDERS AND KEYING
<br />A. GENERAL: CYLINDER MANUFACTURER TO HAVE MINIMUM (10) YEARS OF EXPERIENCE DESIGNING SECURED MASTER KEY
<br />SYSTEMS AND HAVE ON RECORD A PUBLISHED SECURITY KEYING SYSTEM POLICY.
<br />B. SOURCE LIMITATIONS: OBTAIN EACH TYPE OF KEYED CYLINDER AND KEYS FROM THE SAME SOURCE MANUFACTURER AS
<br />LOCKSETS AND EXIT DEVICES, UNLESS OTHERWISE INDICATED.
<br />C. CYLINDERS: ORIGINAL MANUFACTURER CYLINDERS COMPLYING WITH THE FOLLOWING:
<br />1. MORTISE TYPE: THREADED CYLINDERS WITH RINGS AND STRAIGHT- OR CLOVER -TYPE CAM.
<br />2, RIM TYPE: CYLINDERS WITH BACK PLATE, FLAT -TYPE VERTICAL OR HORIZONTAL TAILPIECE, AND RAISED TRIM RING.
<br />3. BORED -LOCK TYPE: CYLINDERS WITH TAILPIECES TO SUIT LOCKS.
<br />4. MORTISE AND RIM CYLINDER COLLARS TO BE SOLID AND RECESSED TO ALLOW THE CYLINDER FACE TO BE FLUSH AND BE
<br />FREE SPINNING WITH MATCHING FINISHES.
<br />5. KEYWAY: MANUFACTURER'S STANDARD.
<br />D. KEYING SYSTEM: EACH TYPE OF LOCK AND CYLINDERS TO BE FACTORY KEYED. COORDINATE KEYING WITH OWNER.
<br />E. KEY QUANTITY: VERIFY QUANTITY WITH OWNER.
<br />SECTION 087100 - DOOR HARDWARE (CONTINUED)
<br />F. CONSTRUCTION KEYING: PROVIDE CONSTRUCTION MASTER KEYED CYLINDERS OR TEMPORARY KEYED
<br />CONSTRUCTION CORES WHERE SPECIFIED. PROVIDE CONSTRUCTION MASTER KEYS IN QUANTITY AS REQUIRED
<br />BY PROJECT CONTRACTOR. REPLACE CONSTRUCTION CORES WITH PERMANENT CORES, FURNISH PERMANENT
<br />CORES FOR INSTALLATION AS DIRECTED BY OWNER.
<br />G. KEY REGISTRATION LIST: PROVIDE KEYING TRANSCRIPT LIST TO OWNER'S REPRESENTATIVE IN THE PROPER
<br />FORMAT FOR IMPORTING INTO KEY CONTROL SOFTWARE.
<br />H. KEY CONTROL SOFTWARE: PROVIDE ONE NETWORK VERSION OF "KEY WIZARD" BRANDED KEY MANAGEMENT
<br />SOFTWARE PACKAGE THAT INCLUDES ONE YEAR OF TECHNICAL SUPPORT AND UPGRADES TO SOFTWARE AT NO
<br />CHARGE. PROVIDE FACTORY KEY SYSTEM FORMATTED FOR IMPORTING INTO "KEY WIZARD" SOFTWARE.
<br />1,12 MECHANICAL LOCKS AND LATCHING DEVICES
<br />A. MORTISE LOCKSETS, GRADE 1 (HEAVY DUTY): ANSI/BHMA A156.13, SERIES 1000, OPERATIONAL GRADE 1 CERTIFIED MORTISE
<br />LOCKSETS FURNISHED IN THE FUNCTIONS AS SPECIFIED IN THE HARDWARE SEES. l
<br />B. CYLINDRICAL LOCKSETS, GRADE 1 (COMMERCIAL DUTY): ANSI/BHMA A156.2, SERIES 4000, GRADE 1 CERTIFIED CYLINDRICAL
<br />(BORED) LOCKSETS FURNISHED IN THE FUNCTIONS AS SPECIFIED IN THE HARDWARE SETS.
<br />C. LOCK TRIM DESIGN: AS SPECIFIED IN HARDWARE SETS.
<br />1.13 STAND ALONE ACCESS CONTROL LOCKING DEVICES
<br />A. STAND ALONE INTEGRATED ACCESS CONTROL LOCKETS: INTERNAL, BATTERY -POWERED, SELF-CONTAINED ANSI GRADE 1
<br />MORTISE OR CYLINDRICAL LOCK CONSISTING OF ELECTRONICALLY MOTOR DRIVEN LOCKING MECHANISM, INTEGRATED
<br />KEYPAD, PROXIMITY CARD READER, OR KEYPAD/PROXIMITY CARD READER COMBINATION, AND SPECIFIED ELECTRONIC
<br />PROGRAMMING ACCESSORIES.
<br />1.14 LOCK AND LATCH STRIKES
<br />A. STRIKES: PROVIDE MANUFACTURER'S STANDARD STRIKE WITH STRIKE BOX FOR EACH LATCH OR LOCK BOLT, WITH CURVED
<br />LIP EXTENDED TO PROTECT FRAME, FINISHED TO MATCH DOOR HARDWARE SET, UNLESS OTHERWISE INDICATED, AND AS
<br />FOLLOWS:
<br />p T' N
<br />1. FLAT -LIP STRIKES: FOR LOCKS WITH THREE-PIECE ANTIFRICTION LATCHBOLTS AS RECOMMENDED BY MANUFACTURER.
<br />2, ALUMINUM -FRAME STRIKE BOX: PROVIDE MANUFACTURER'S SPECIAL STRIKE BOX FABRICATED FOR ALUMINUM FRAMING.
<br />B. STANDARDS: COMPLY WITH THE FOLLOWING:
<br />1. STRIKES FOR MORTISE LOCKS AND LATCHES: BHMA A156.13.
<br />2. STRIKES FOR BORED LOCKS AND LATCHES: BHMA A156.2.
<br />3. STRIKES FOR AUXILIARY DEADLOCKS: BHP""AA156.5.
<br />4. DUSTPROOF STRIKEC: BHMA A156.16.
<br />1.15 CONVENTIONAL EXIT DEVICES
<br />A. GENERAL REQUIREMENTS: ALL EXIT DEVICES SPECIFIED HEREIN SHALL MEET OR EXCEED THE FOLLOWING CRITERIA:
<br />1. AT DOORS NOT REQUIRING AFIRE RATING, PROVIDE DEVICES COMPLYING WITH NFPA 101 AND LISTED AND LABELED FOR
<br />"PANIC HARDWARE" ACCORDING TO UI.305. PROVIDE PROPER FASTENERS AS REQUIRED BY MANUFACTURER INCLUDING SEX
<br />NUTS AND BOLTS AT OPENINGS SPECIFIED IN THE HARDWARE SETS.
<br />2. WHERE EXIT DEVICES ARE REQUIRED ON FIRE RATED DOORS, PROVIDE DEVICES COMPLYING WITH NFPA 80 AND WITH UL
<br />LABELING INDICATING "FIRE EXIT HARDWARE". PROVIDE DEVICES WITH THE PROPER FASTENERS FOR INSTALLATION AS
<br />TESTED AND LISTED BY UL. CONSULT MANUFACTURER'S CATALOG AND TEMPLATE BOOK FOR SPECIFIC REQUIREMENTS.
<br />a. FIRE EXIT REMOVABLE MULLIONS: PROVIDE KEYED REMOVABLE MULLIONS FOR USE WITH FIRE EXIT DEVICES COMPLYING
<br />WITH NFPA 80 THAT ARE LISTED AND LABELED BY A TESTING AND INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING
<br />JURISDICTION, FOR FIRE AND PANIC PROTECTION, BASED ON TESTING ACCORDING TO UL 305 AND NFPA 252. MULLIONS TO BE
<br />USED ONLY WITH EXIT DEVICES FOR WHICH THEY HAVE BEEN TESTED.
<br />3. EXCEPT ON FIRE RATED DOORS, PROVIDE EXIT DEVICES WITH HEX KEY DOGGING DEVICE TO HOLD THE PUSHBAR AND
<br />LATCH IN A RETRACTED POSITION. PROVIDE OPTIONAL KEYED CYLINDER DOGGING ON DEVICES WHERE SPECIFIED IN
<br />HARDWARE SETS.
<br />4. FLUSH END CAPS: PROVIDE HEAVY WEIGHT IMPACT RESISTANT FLUSH END CAPS MADE OF ARCHITECTURAL METAL IN THE
<br />SAME FINISH AS THE DEVICES AS IN THE HARDWARE SETS. PLASTIC END CAPS WILL NOT BE ACCEPTABLE.
<br />5. LEVER OPERATING TRIM: WHERE EXIT DEVICES REQUIRE LEVER TRIM, FURNISH MANUFACTURER'S HEAVY DUTY TRIM WITH
<br />COLD FORGED ESCUTCHEONS, BEVELED EDGES, AND FOUR THREADED STUDS FOR THRU-BOLTS.
<br />a. LOCK TRIM DESIGN: AS INDICATED IN HARDWARE SETS, PROVIDE FINISHES AND DESIGNS TO MATCH THAT OF THE
<br />SPECIFIED LOCKSETS. PROVIDED FREE -WHEELING TYPE TRIM WHERE INDICATED.
<br />b. WHERE FUNCTION OF EXIT DEVICE REQUIRES A CYLINDER, PROVIDE AN INTERCHANGEABLE CORE TYPE KEYED CYLINDER
<br />(RIM OR MORTISE) AS SPECIFIED IN HARDWARE SETS.
<br />0. VERTICAL ROD EXIT DEVICES: PROVIDE AND INSTALL INTERIOR SURFACE AND CONCEALED VERTICAL ROD EXIT DEVICES AS
<br />LESS BOTTOM ROD (LBR) UNLESS OTHERWISE INDICATED.
<br />7. NARROW STILE APPLICATIONS: AT DOORS CONSTRUCTED WITH NARROW STILES. OR AS SPECIFIED IN HARDWARE SETS,
<br />PROVIDE DEVICES DESIGNED FOR MAXIMUM 2" WIDE STILES,
<br />8. DUMMY PUSH BAR: NONFUNCTiONING PUSH BAR MATCHING FUNCTIONAL PUSH BAR.
<br />9. RAIL SIZING: PROVIDE EXIT DEVICE RAILS FACTORY SIZED FOR PROPER DOOR WIDTH APPLICATION.
<br />10. THROUGH BOLT INSTALLATION: FOR EXIT DEVICES AND TRIM AS INDICATED IN DOOR HARDWARE SETS,
<br />B. CONVENTIONAL PUSH RAIL EXIT DEVICES (HEAVY DUTY): ANSI/BHMA A156.3, GRADE 1 CERTIFIED PANIC AND FIRE EXIT
<br />HARDWARE DEVICES FURNISHED IN THE FUNCTIONS SPECIFIED IN THE HARDWARE SETS. MOUNTING RAILS TO BE FORMED
<br />FROM SMOOTH STAINLESS STEEL, BRASS OR BRONZE ARCHITECTURAL MATERIALS NO LESS THAN 0.072" THICK, WITH PUSH
<br />RAILS A, MINIMUM OF 0.062" THICKNESS. PAINTED OR ALUMINUM METAL RAILS ARE NOT ACCEPTABLE. EXIT DEVICE LATCH TO BE
<br />INVESTMENT CAST S T AIMLESS STEEL, PULLMAN TYPE, WITH DEADLOCK FEATURE.
<br />1.16 DOOR CLOSERS
<br />A. DOOR CLOSERS, SURFACE MOUNTED (LARGE BODY CAST IRON): ANSI/BHMA A156.4, GRADE 1 SURFACE MOUNTED, HEAVY
<br />DUTY DOOR CLOSERS WITH COMPLETE SPRING POWER ADJUSTMENT, SIZES 1 THRU 6; AND FULLY OPERATIONAL ADJUSTABLE
<br />ACCORDING TO DOOR SIZE, FREQUENCY OF USE, AND OPENING FORCE.
<br />B. DOOR CLOSERS, SURFACE MOUNTED (HEAVY DUTY): ANSI/BHMA A156.4, GRADE 1 SURFACE MOUNTED, HEAVY DUTY DOOR
<br />CLOSERS WITH COMPLETE SPRING POWER ADJUSTMENT, SIZES 1 THRU 6; AND FULLY OPERATIONAL ADJUSTABLE ACCORDING
<br />TO DOOR SIZE. FREQUENCY OF USE, AND OPENING FORCE.
<br />C. DOOR CLOSERS, SURFACE MOUNTED (COMMERCIAL DUTY): ANSI/BHMA 156.4, GRADE 1 CERTIFIED SURFACE MOUNTED,
<br />INSTITUTIONAL_ GRADE D.^.OR CLOSERS WITH COMPLETE SPRING POWER ADJUSTMENT, SIZES 1 THRU 6; AND FULLY
<br />OPERATIONAL ADJUSTABLE ACCORDING TO DOOR SIZE, FREQUENCY OF USE, AND OPENING FORCE.
<br />1.17 AUTOMATIC DOOR OPERATORS
<br />A. GENERAL: PROVIDE OPERATORS OF SIZE RECOMMENDED BY MANUFACTURER FOR DOOR SIZE, WEIGHT, AND MOVEMENT;
<br />FOR CONDITION OF EXPOSURE; AND FOR COMPLIANCE WITH UL 325. COORDINATE OPERATOR MECHANISMS WITH DOOR
<br />OPERATION, HINGES. AND ACTIVATION DEVICES.
<br />1. FIRE -RATED DOORS: PROVIDE DOOR OPERATORS FOR FIRE -RATED DOOR ASSEMBLIES THAT COMPLY WITH NFPA 80 FOR
<br />IRE -RATED DOOR COMPONENTS AND ARE LISTED AND LABELED
<br />FN DBY A QUALIFIED TESTING AGENCY.
<br />�^
<br />B. ELECTROMECHANICAL DOOR OPERATORS: SELF-CONTAINED UNIT POWERED BY PERMANENT MAGNET DC MOTOR WITH
<br />C S
<br />CLOSING SPEED CONTROLLED MECHANICALLY BY GEAR TRAIN, CONNECTIONS FOR POWER, ACTIVATION AND SAFETY DEVICE
<br />WIRING, AND MANUAL OPERATiON INCLUDING SPRING CLOSING WHEN POWER IS OFF.
<br />C. ELECTROHYDRAULIC DOOR OPERATORS: SELF-CONTAINED LOW-PRESSURE UNITS WITH RACK AND PINION DESIGN
<br />CONTAINED WITHIN A CAST ALUMINUM HOUSING. DOOR CLOSING SPEED CONTROLLED BY INDEPENDENT HYDRAULIC
<br />ADJUSTMENT VALVES IN THE SWEEP AND LATCH RANGE OF THE CLOSING CYCLE. OPERATOR IS TO PROVIDE CONVENTIONAL
<br />DOOR CLOSER OPENING AND CLOSING FORCES UNLESS THE POWER OPERATOR MOTOR IS ACTIVATED. UNIT IS TO INCLUDE AN
<br />ADJUSTABLE HYDRAULIC BACKCHECK VALVE TO CUSHION THE DOOR SPEED IF OPENED VIOLENTLY. NON -HANDED UNITS FOR
<br />BOTH PUSH AND PULL SIDE APPLICATIONS.
<br />D. BRACKETS AND REINFORCEMENTS: MANUFACTURER'S STANDARD, FABRICATED FROM ALUMINUM WITH NONFERROUS SHIMS
<br />FOR ALIGNING SYSTEM COMPONENTS. E. STANDARD: CERTIFIED ANSI/BHMA A156.19.
<br />1. PERFORMANCE REQUIREMENTS:
<br />a. OPENING FORCE IF POWER FAILS: NOT MORE THAN 15 LBF REQUIRED TO RELEASE A LATCH IF PROVIDED, NOT MORE THAN
<br />30 LBF REQUIRED TO MANUALLY SET DOOR IN MOTION, AND NOT MORE THAN 15 LBF REQUIRED TO FULLY OPEN DOOR.
<br />b. ENTRAPMENT PROTECTION: NOT MORE THAN 15 LBF REQUIRED TO PREVENT STOPPED DOOR FROM CLOSING OR OPENING.
<br />F. CONFIGURATION: SURFACE MOUNTED. DOOR OPERATORS TO CONTROL SINGLE SWINGING AND PAIR OF SWINGING DOORS.
<br />G. OPERATION: POWER OPENING AND SPRING CLOSING OPERATION CAPABLE OF MEETING ANSI A117.1 ACCESSIBILITY
<br />GUIDELINE. PROVIDE TIME DELAY FOR DOOR TO REMAIN OPEN BEFORE INITIATING CLOSING CYCLE AS REQUIRED BY
<br />ANSI/BHMA A156.19. WHEN NOT IN AUTOMATIC MODE, DOOR OPERATOR TO FUNCTION AS MANUAL DOOR CLOSER WITH FULLY
<br />ADJUSTABLE OPENING AND CLOSING FORCES, WITH OR WITHOUT ELECTRICAL POWER.
<br />1. ON -OFF SWITCH TO CONTROL POWER TO BE KEY SWITCH OPERATED.
<br />H. FEATURES: OPERATOR UNITS TO HAVE FULL FEATURE ADJUSTMENTS FOR DOOR OPENING AND CLOSING FORCE AND
<br />SPEED, BACKCHECK, MOTOR ASSIST ACCELERATION FROM 0 TO 30 SECONDS, TIME DELAY, VESTIBULE INTERFACE DELAY,
<br />OBSTRUCTION RECYCLE, AND HOLD OPEN TIME FROM 0 UP TO 30 SECONDS.
<br />I. PROVIDE OUTPUTS AND RELAYS ON BOARD THE OPERATOR TO ALLOW FOR COORDINATION OF EXIT DEVICE LATCH
<br />RETRACTION, ELECTRIC STRIKES, MAGNETIC LOCKS, CARD READERS, SAFETY AND MOTION SENSORS AND SPECIFIED
<br />AUXILIARY CONTACTS,
<br />J. ACTIVATION DEVICES: PROVIDE ACTIVATION DEVICES IN ACCORDANCE WITH ANSI/BHMA A156.19 STANDARD, FOR CONDITION
<br />OF EXPOSURE INDICATED AND FOR LONG TERM, MAINTENANCE FREE OPERATION UNDER NORMAL TRAFFIC LOAD OPERATION.
<br />COORDINATE ACTIVATION CONTROL WITH ELECTRIFIED HARDWARE AND ACCESS CONTROL INTERFACES. ACTIVATION
<br />SWITCHES ARE STANDARD SPST, WITH OPTIONAL DPDT AVAILABILITY.
<br />K. SIGNAGE: AS REQUIRED BY CITED ANSI!BHMA A156.19 STANDARD FOR THE TYPE OF OPERATOR.
<br />1.18 ARCHITECTURAL TRIM
<br />A. DOOR PROTECTIVE TRIM
<br />1. GENERAL: DOOR PROTECTIVE TRIM UNITS TO BE OF TYPE AND DESIGN AS SPECIFIED BELOW OR IN THE HARDWARE SETS.
<br />2. SIZE: FABRICATE PROTECTION PLATES (KICK, ARMOR, OR MOP) NOT MORE THAN 2" LESS THAN DOOR WIDTH (LDW) ON STOP
<br />SIDE OF SINGLE DOORS Al" LDW ON STOP SIDE OF PAIRS OF DOORS, AND NOT MORE THAN 1" LESS THAN DOOR WIDTH ON
<br />PULL SIDE. COORDNA T E AND PROVIDE PROPER WIDTH AND HEIGHT AS REQUIRED WHERE CONFLICTING HARDWARE DICTATES.
<br />HEIGHT TO BE AS SPECIFIED IN THE HARDWARE SETS.
<br />3. METAL PROTECTION PLATES: ANSI/BHMA A156.6 CERTIFIED METAL PROTECTION PLATES (KICK, ARMOR, OR MOP), BEVELED
<br />ON FOUR EDGES (B4E), FABRICATED FROM THE FOLLOWING.
<br />a. STAINLESS STEEL. 050-INCH THICK, WITH COUNTERSUNK SCREW HOLES (CSK).
<br />4. FASTENERS: PROVIDEMANUFACTURER'S DESIGNATED FASTENER TYPE AS SPECIFIED IN THE HARDWARE SETS.
<br />5, METAL DOOR EDGING: DOOR PROTECTION EDGING FABRICATED FROM A MINIMUM .050-INCH THICK METAL SHEET, FORMED
<br />INTO AN ANGLE OR "U" CAP SHAPES, SURFACE OR MORTISED MOUNTED ONTO EDGE OF DOOR. PROVIDE APPROPRIATE LEG
<br />OVERLAP TO ACCOUNT FOR PROTECTION PLATES AS REQUIRED. HEIGHT TO BE AS SPECIFIED IN THE HARDWARE SETS.
<br />SECTION 087100 - DOOR HARDWARE (CONTINUED)
<br />1.19 DOORSTOPS AND HOLDERS
<br />A. DOORSTOPS AND BUMPERS: ANSI/BHMA A156.16, GRADE 1 CERTIFIED DOORSTOPS AND WALL BUMPERS.
<br />B. OVERHEAD DOORSTOPS AND HOLDERS: ANSI/BHMA A156.6, GRADE! CERTIFIED OVERHEAD STOPS AND HOLDERS TO BE
<br />SURFACE OR CONCEALED TYPES.
<br />1.20 ARCHITECTURAL SEALS
<br />A. GENERAL: THRESHOLDS, WEATHERSTRIPPING, AND GASKET SEALS TO BE OF TYPE AND DESIGN AS SPECIFIED BELOW OR
<br />IN THE HARDWARE SETS. PROVIDE CONTINUOUS WEATHERSTRIP GASKETING ON EXTERIOR DOORS AND PROVIDE SMOKE,
<br />LIGHT, OR SOUND GASKETING ON INTERIOR DOORS WHERE INDICATED. AT EXTERIOR APPLICATIONS PROVIDE NON-
<br />CORROSIVE FASTENERS AND ELSEWHERE WHERE INDICATED.
<br />B. SMOKE LABELED GASKETING: ASSEMBLIES COMPLYING WITH NFPA 105 THAT ARE LISTED AND LABELED BY A TESTING
<br />AND INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, FOR SMOKE CONTROL RATINGS INDICATED,
<br />BASED ON TESTING ACCORDING TO UL 17$4.
<br />1. PROVIDE SMOKE LABELED PERIMETER GASKETING AT ALL SMOKE LABELED OPENINGS.
<br />C. FIRE LABELED GASKETING: ASSEMBLIES COMPLYING WITH NFPA 80 THAT ARE LISTED AND LABELED BY .A TESTING AND
<br />INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. FOR ril RATINGS INDICATED, BASED ON
<br />TESTING ACCORDING TO UL-10C,
<br />1. PROVIDE INTUMESCENT SEALS AS INDICATED TO MEET UL10C STANDARD FOP, POSITIVE PRESSURE FIRE TESTS OF GC0,
<br />ASSEMBLIES, AND UBC 7-2, FIRE TESTS OF DOOR ASSEMBLIES.
<br />D. SOUND -RATED GASKETING: ASSEMBLIES THAT ARE LISTED AND LABELED 811, A TESTINNG .AI`d0 INSPECTif�(. t::tNC'r, F-"-
<br />SOUND RATINGS INDICATED, BASED ON TESTING ACCORDING TO ASTV. E 1408.
<br />E. REPLACEABLE SEAL STRIPS: PROVIDE ONLY THOSE UNITS'NHERE RESILIENT OR FLEXIBLE SEAL,--; RirS AF2 EAS:LY
<br />REPLACEABLE AND READILY AVAILABLE FROM STOCKS MAiNTAtiVED BY Pv1.ANUFk,'TUR4R.
<br />1.21 ELECTRONIC ACCESSORIES
<br />A. PUSH-BUTTON SWITCHES: INDUSTRIAL GRADc P610PAENTARY OR .ALTERi J,aTE CONT;,%C, 6;=.CK-LICK'"ED r: ISH sUTTC�NS
<br />WITH STAINLESS -STEEL SWITCH ENCLOSURES, 12124 VDC B!-COLOR iLLU?."NATIOti si:iTABL.E FOR E! iFHER i=L1:Si-I CR.
<br />SURFACE MOUNTING.
<br />T .,r. _
<br />Y
<br />7 i ,
<br />F TESTING , v) B. POWER SUPPLIES: PROVIDE NATIONALLY RECOGNIZED ES v� LABC4AT CRY � „ tD I< < � GT: �a. JC ,�L_
<br />SELECTABLE) FILTERED AND REGULATED POWER SUPPLIES, INCLUDE Ba. I ERY BACKUP �� Jh-H
<br />F.r_.PA.R rI
<br />EFT
<br />CHARGING CAPABILITY IN ADDITION TO OPERATING THE DC LOAD IN EVENT OF LINE VOLTAGE FAILURE. PROVIDE THE LEAST
<br />NUMBER OF UNITS, AT THE APPROPRIATE AMPERAGE LEVEL, SUFFICIENT TO EXCEED THE REQUIRED TOTAL DRAW FOR THE
<br />SPECIFIED ELECTRIFIED HARDWARE AND ACCESS CONTROL EQUIPMENT
<br />1.22 FABRICATION
<br />A. FASTENERS: PROVIDE DOOR HARDWARE MANUFACTURED TO COMPLY °VITH PUBLISHED TLE MP+_ATES GENERALLY
<br />PREPARED FOR MACHINE, WOOD, AND SHEET METAL SCREWS. PROVIDE SCREV'v5 ACCORDING TO 111~,NUFACTURERS
<br />RECOGNIZED INSTALLATION STANDARDS FOR APPL (CATION INTENDED,
<br />1.23 FINISHES
<br />A. STANDARD: DESIGNATIONS USED IN THE HARDWARE SETS AND ELSEWHERE !NDICATE HARDWARE FINISHES COMPLYING
<br />WITH ANSI/BHMA A156.14, INCLUDING COORDINATION WITH TRADITIONAL U.S. FiN{SHES INDICATED BY CER T AIN
<br />MANUFACTURERS FOR THEIR PRODUCTS.
<br />B. PROVIDE QUALITY OF FINISH, INCLUDING THICKNESS OF PLATING OR COATING fIF ANY), C OMPOSI?ION, HA.PF)l AND
<br />OTHER QUALITIES COMPLYING WITH MANUFACTURER'S STANDARDS, BUT IN NO CASE LESS THAN SPECIFIED B'(
<br />REFERENCED STANDARDS FOR THE APPLICABLE UNITS OF HARDWARE.
<br />C. PROTECT MECHANICAL FINISHES ON EXPOSED SURFACES FROM DAMAGE BY APPLYING A STRIPPABLE, TEMPORARY
<br />PROTECTIVE COVERING BEFORE SHIPPING.
<br />1.24 EXAMINATION
<br />A. EXAMINE SCHEDULED OPENINGS, WITH INSTALLER PRESENT. FOR COMPLIANCE WITH REQUIREMENTS FOR INSTALLATION
<br />TOLERANCES, LABELED FIRE DOOR ASSEMBLY CONSTRUCTION, WALL AND FLOOR CONSTRUCTION, AND OTHER CONDITIONS
<br />AFFECTING PERFORMANCE.
<br />B. NOTIFY ARCHITECT OF ANY DISCREPANCIES OR CONFLICTS BETWEEN THE DCOR SCHEDULE. DOOR TYPES, DRAWINGS
<br />AND SCHEDULED HARDWARE. PROCEED ONLY AFTER SUCH DISCREPANCIES OR CONFLICTS HAVE BEEN RESOLVED IN
<br />WRITING.
<br />1.25 PREPARATION
<br />A. HOLLOW METAL DOORS AND FRAMES: COMPLY WITH Al A115 SERIES.
<br />B. WOOD DOORS: COMPLY WITH ANSI/DHI A115-W SERIES.
<br />1.26 INSTALLATION
<br />A. INSTALL EACH ITEM OF MECHANICAL AND ELECTROMECHANICAL HARDWARE AND ACCESS CONTROL EQUIPMENT TC
<br />COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND ACCORDING TO SPECIFICATIONS.
<br />1. INSTALLERS ARE TO BE TRAINED AND CERTIFIED BY THE MANUFACTURER ON TH: PROPER INST„LATIU.J "dJD
<br />ADJUSTMENT OF FIRE, LIFE SAFETY, AND SECURITY PRODUCTS !NCLUDI.\iG: HANNGING DE''!ICES; LOCKING'OC\+iCES: CLOSING
<br />DEVICES; AND SEALS.
<br />B. MOUNTING HEIGHTS: MOUNT DOOR HARDWARE UNITS AT HEIGHTS INDICATED IN FOLLCV'lING APPLiCABLE !'tJ6LICAT1010!3,
<br />UNLESS SPECIFICALLY INDICATED OR REQUIRED TO COMPLY Y'viTH G, I_RPv ... REGULATIONS: i,. NS. i. STf„NDAh(D 6 , ELL uiVVhJ
<br />AND FRAMES: DHI'S "RECOMMENDED LOCATIONS FOR ARCHITECTURAL PARl FCR STAPDARD ST`E.EL DC11-)iZS AND
<br />FRAMES."
<br />1. WOOD DOORS: DHI WDHS.3, "RECOMMENDED LOCATIONS FOR AP,CH!TECTLIRAL HARD'r1'ArRE FOR WOOD R.US;', DOORC "
<br />2. WHERE INDICATED TO COMPLY WITH ACCESSIBILITY REQUIREMENTS. COk".9 � WiTH ANSI ,1,1'.71 "ACCESS-9iLITY
<br />GUIDELINES FOR BUILDINGS AND FACILITIES."
<br />3. PROVIDE BLOCKING IN DRYWALL PARTITIONS WHERE WALL STOPS OR OTHER WALL MOUNTED HARDV'''A E_ IS LOCATECI.
<br />C. RETROFITTING: INSTALL DOOR HARDWARE TO COMPLY WITH MANUFACTURER'S PUBLISHED TEMPLATES AND WRITTEN
<br />INSTRUCTIONS. WHERE CUTTING AND FITTING ARE REAL IREU ?0 INSTALL DOOR HARD(^!ARE ONTO ORINTO SURFACES THAT
<br />ARE LATER TO BE PAINTED OR FINISHED IN ANOTHER WAY, COORDINATE REMOVAL, STORAGE, AND RENSTALLATON OF
<br />SURFACE PROTECTIVE TRIM UNITS WITH FINISHING WORK SPECIFIED IN DIViSION 9 SECTIONS. DC NOT INSTALL SURFACE -
<br />MOUNTED ITEMS UNTIL FINISHES HAVE BEEN COMPLETED ON SUBSTRATES INVOLVED.
<br />D. THRESHOLDS: SET THRESHOLDS FOR EXTERIOR AND .ACOUSTICAL DOORS IN FiiLL BED OF SEALANT CO"APL:'(iNG WITH
<br />REQUIREMENTS SPECIFIED IN DIVISION 7 SECTIOtr' "JOINT SEALANTS."
<br />E. STORAGE: PROVIDE A SECURE LOCK UP FOR HARDWARE DELIVERED TO THE PROJECT BUT NOT YET ;..! STALLED
<br />CONTROL THE HANDLING AND INSTALLATION OF HARDWARE !TEEMS SO THAT THE COMPLETION OF THE WORK -ILL NOT BE
<br />DELAYED BY HARDWARE LOSSES BEFORE AND AFTER INSTALLATION,
<br />1.27 ADJUSTING
<br />A. INITIAL ADJUSTMENT: ADJUST AND CHECK EACH OPERATING ITEM OF DOOR HARDWARE AND EACH DOOR TO ENSURE
<br />PROPER OPERATION OR FUNCTION OF EVERY UNIT, REPLACE UNITS THAT CANNOT BE ADJUSTED ?0 OPERATE F AS IN �T
<br />ENDED
<br />ADJUST DOOR CONTROL DEVICES TO COMPENSATE FOR FINAL OPERATION OF HEATING AND VENTILATING EQUIPMENT AND
<br />TO COMPLY WITH REFERENCED ACCESSIBILITY REQUIREMENTS.
<br />1.28 DEMONSTRATION
<br />A. INSTRUCT OWNER'S MAINTENANCE PERSONNEL TO ADJUST, OPERATE, AND MAINTAIN MECHANICAL AND
<br />ELECTROMECHANICAL DOOR HARDWARE.
<br />1.29 DOOR HARDWARE SCHEDULE
<br />A. REFER TO DRAWINGS FOR DOOR SCHEDULE AND HARDWARE SETS.
<br />SECTION 088000 - GLAZING
<br />1.1 SUMMARY
<br />A. SECTION INCLUDES:
<br />1. GLASS FOR INSULATED GLAZING UNITS.
<br />1. SINGLE PANE GLAZING.
<br />2. GLAZING SEALANTS AND ACCESSORIES.
<br />1.2 DEFINITIONS
<br />A. SEALED INSULATING GLASS UNIT SURFACES:
<br />1. SURFACE NO. 1: EXTERIOR SURFACE OF OUTER LITE.
<br />2. SURFACE NO. 2: INTERIOR SURFACE OF OUTER LITE.
<br />3. SURFACE NO. 3: EXTERIOR SURFACE OF INNER LITE,
<br />4. SURFACE NO. 4: INTERIOR SURFACE OF INNER LITE.
<br />B. AIRSPACE: SPACE BETWEEN LITES OF AN INSULATING GLASS UNIT THAT CONTAINS DEHI'DR/ATE'' AIR. OR';'!'ER INERT
<br />SPECIFIED GAS
<br />1.3 COORDINATION
<br />A. COORDINATE GLAZING CHANNEL DIMENSIONS TO PROVIDE NECESSARY SITE ON GUiSS, MN!MUM%I _DrE AND FACZ
<br />CLEARANCES, AND ADEQUATE SEALANT THICKNESSES, WITH REASONABLE TOLERANCES.
<br />1.4 ACTION SUBMITTALS
<br />A. REFER TO SECTION 013300 FOR SUBMITTAL REQUiREMENTS,
<br />B. PRODUCT DATA: FOR EACH TYPE OF PRODUCT.
<br />C. GLASS SAMPLES: AS REQUESTED BY ARCHITECT.
<br />D. GLAZING SCHEDULE: LIST GLASS TYPES AND THICKNESSES FOR EACH SIZE OPENING A1413, LOCATION. USE CAivIE
<br />DESIGNATIONS INDICATED ON DRAWINGS.
<br />E. DELEGATED -DESIGN SUBMITTAL: FOR GLASS INDICATED TO COMPLY WIT H PERFORMANCE REQUiREMENTS AND DESIGN
<br />CRITERIA, INCLUDING ANALYSIS DATA SIGNED AND SEALED BY "T"r!E QUALIFIED PROFESSIONAL ENGINEER RESPONSIBLE F-OR
<br />THEIR PREPARATION.
<br />1.5 INFORMATIONAL SUBMITTALS
<br />A. PRECONSTRUCTION ADHESION AND COMPATIBILiTY TEST REPORT.
<br />1.6 QUALITY ASSURANCE
<br />A. MANUFACTURER'S QUALIFICATIONS: MINIMUM OF 5 YEARS EXPERIENCE MANUFACTURING SOLAR CONTROL COATED
<br />GLASS.
<br />B. FABRICATOR'S QUALIFICATIONS: MINIMUM OF 5 YEARS' EXPERIENCE MANUFACTURING SEALED INSULATING GLASS UNITS
<br />MEETING ASTM E 2190, CLASS CBA AND CERTIFIED BY MANUFA.0 T URER.
<br />D. SEALANT TESTING AGENCY QUALIFICATIONS: AN INDEPENDENT TESTING AGENCY QUALIFIED ACCORDING TO �. 71!0 C 1021
<br />TO CONDUCT THE TESTING INDICATED.
<br />1.7 DELIVERY, STORAGE, AND HANDLING
<br />A. DELIVER, STORE, AND HANDLE IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS.
<br />I - /-% )
<br />p 813 241 5700 f 8 ; 247 3757
<br />#� e• . qr'`i..9, , ; 1.)•f ,.. 1,,J,.. ; ,,.
<br />All Iepl.0urtior& inteliectuai property
<br />rights resented 2017
<br />Project
<br />,-"" ,
<br />. t
<br />..,. aV i c,
<br />D M%G 11=
<br />zE P � � H i k 15 i...Ls
<br />5935 7th Street Zephyrhills,
<br />FL 33542
<br />Prepared for
<br />in Association With:
<br />HEES &ASSOCIATES iNC,.
<br />CO ACT: t ARL HEES
<br />13815TH ST
<br />SARASOTA, `"'_ 34236
<br />PHONE: 941.955.4555
<br />GENESIS ENGINEER Gl LLC
<br />CONTACT: MIKE HANEY
<br />1000 N. ASHLEY DR. #900
<br />TAMPA, FL
<br />H O i•d E: 813.523.6455
<br />GENESIS ENGiNF; lR GRO; P ' Ll'
<br />CONTACT: MI tiANEY
<br />1 0 ti fl Y DR � r!1
<br />00� .. HSh_E , �, .. 9u�
<br />TAMPA, FL
<br />PHONE: 813.523.6455
<br />- -p * _...
<br />Pr "s'sbral Seal �; ',_I,
<br />`7.
<br />.:,
<br />I.
<br />1T
<br />Y
<br />. ,
<br />m , 8
<br />r:1
<br />h
<br />tv I I aNbb s; � �
<br />i
<br />K
<br />gzz-`
<br />i rew J. Dohmen, AR 4 i 2/ 1012013
<br />15805 11:22:42 AM
<br />No. Revision Description) Date
<br />i PERMIT AND BID SET 12/10/2018
<br />`i0. Revision D 6SC' Y+ti " Date
<br />Dram By: V VJ Checked By: SRS
<br />Project Number: 18190
<br />Sheet Title
<br />SPECIFIC; �5 I III Il
<br />Original dravbnny is 24 x 36 Do not
<br />scale contents of urav":ng
<br />Sheet Numbe;
<br />iI ,.: � ,1,
<br />I I
<br />, , �, "-i __ I -
<br />I ,
<br />Lm-q. mb.�.
<br />
|