- - I I n JT I L- - 1 I -1 III -_ n ! - - -- 1� - - - - -� � �--I--- - - - - � . - - -- - -- <br />a <br />u <br />- - <br />a � <br />SECTION 084113 - ALUMINUM -FRAMED ENTRANCES AND STOREFRONTS (CONTINUED) <br />B. INTERIOR FRAMING MEMBERS. <br />1, SYSTEM AND FINISH. AS SCHEDULED ON DRAWINGS <br />2, MANUFACTURER'S EXTRUDED ALUMINUM FRAMING MEMBERS OF THICKNESS REQUil AND REINFORCED AS REQUIRED TO <br />SUPPORT IMPOSED LOADS. <br />3, FABRICATION METHOD: FACTORY FABRICATED AND SHIPPED KNOCKDOWN FOR INSTALLATION BY THE GLAZING SUB- <br />CONTRACTOR. <br />C. BACKER PLATES: MANUFACTURER'S STANDARD, CONTINUOUS BACKER PLATES FOR FRAMING MEMBERS, IF NOT INTEGRAL, <br />WHERE FRAMING ABUTS ADJACENT CONSTRUCTION, <br />D. BRACKETS AND REINFORCEMENTS: MANUFACTURER'S STANDARD HIGH -STRENGTH ALUMINUM WITH NONSTAINING, <br />NONFERROUS SHIMS FOR ALIGNING SYSTEM COMPONENTS. <br />E. SILL PLATES AND FLASHINGS: PROVIDE SILL PLATES, FLASHINGS AND FLASHING ACCESSORIES TO ACCOMMODATE POSITIVE <br />DRAINAGE AND SILL PROTECTION AT GLAZED OPENINGS. REFER TO ARCHITECTURAL DRAWINGS. <br />F. MATERIALS: <br />1. ALUMINUM: ALLOY AND TEMPER RECOMMENDED BY MANUFACTURER FOR TYPE OF USE AND FINISH INDICATED. <br />a. SHEET AND PLATE: ASTM B 209. <br />b. EXTRUDED BARS, RODS, PROFILES, AND TUBES: ASTM B 221. <br />c. EXTRUDED STRUCTURAL PIPE AND TUBES: ASTM B 429/13 429M. <br />d. STRUCTURAL PROFILES: ASTM B 308/B 308M. <br />2. STEEL REINFORCEMENT: MANUFACTURER'S STANDARD ZINC -RICH, CORROSION -RESISTANT PRIMER COMPLYING WITH SSPC <br />PS GUIDE NO. 12.00; APPLIED IMMEDIATELY AFTER SURFACE PREPARATION AND PRETREATMENT. SELECT SURFACE <br />PREPARATION METHODS ACCORDING TO RECOMMENDATIONS IN SSPC-SP COM, AND PREPARE SURFACES ACCORDING TO <br />APPLICABLE SSPC STANDARD. <br />a. STRUCTURAL SHAPES, PLATES, AND BARS: ASTM A 36,A 36M. <br />b. COLD -ROLLED SHEET AND STRIP: ASTM A 1008A 10081\1, <br />c. HOT -ROILED SHEET AND STRIP: iaSTM A 10??/A 1011Ps. <br />1.10 ENTRANCE DOUR SYSTEMS <br />A. MANUFACTURERS FACTURERS STAD R N A : ENTRANCr <br />E DOOR. <br />1 BASS OF DESIrNn. S SCHED ON CPAVINCS <br />. <br />2. DOOR CONSTRUCTION: 1-314-INCH OVERALL THICKNESS, WITH MINIMUM 0.125-INCH THICK, EXTRUDED -ALUMINUM TUBULAR <br />RAIL AND STILE MEMBERS. MECHANICALLY FASTEN CORNERSVd{TH REINFORCING BRACKETS THAT ARE DEEPLY PENETRATED <br />AND FILLET VtfELDED OR THAT INCORPORATE CONCEALED TIE RODS, <br />3. DOOR. DESIGN: <br />a. NC-D!UPA STILE; 3-1/ !NCH NOi'AINAL WIDTH. <br />b. 10 INCH NOMINAL 80TTOM RAIL. <br />4. GLAZING: <br />a. INTERIOR LOCATIONS: 3/8 INCH CLEAR TEMPERED GLAZING, UNLESS NCTED EXTERIOR AND VESTIBULE DOORS: 1 INCH <br />CLEAR INSULATED GLASS UNIT, UNLESS NOTED OTHERWISE. <br />b, REFER TO SECTION 088000 "GLAZING". <br />5. GLAZING STOPS AND GASKETS: BEVELED AT THE STILES AND SQUARE AT THE RAILS SNAP -ON, EXTRUDED -ALUMINUM <br />STOPS AND PREFORMED GASKETS. <br />a. PROVIDE NON -REMOVABLE GLAZING STOPS ON OUTSIDE OF DOOR. <br />1.11 ENTRANCE DOOR HARDWARE <br />A. DOOR HARDWARE: HARDWARE IS SPECIFIED IN SECTION 087100 "DOOR HARDWARE" AND AS SCHEDULED ON THE DRAWINGS. <br />1. SUBSTITUTIONS NOT PERMITTED. <br />B. COORDINATION: <br />1, DAVITA DOOR HARDWARE VENDOR (LOCKNET) TO PROVIDE AUTOMATIC OPERATORS AND PUSH PLATE HARDWARE ONLY, <br />UNLESS COORDINATED OTHERWISE, INSTALLATION COORDINATED BY GENERAL CONTRACTOR, <br />2. ALL OTHER HARDWARE TO BE SUPPLIED BY ALUMINUM STOREFRONT MANUFACTURER. <br />3, COORDINATE ALTERNATIVE DOOR HARDWARE PROVISIONS WITH DAVITA DOOR HARDWARE VENDOR. <br />C. GENERAL: PROVIDE DOOR HARDWARE INDICATED IN THE'DOOR HARDWARE SCHEDULE" ON DRAWINGS FOR EACH <br />ENTRANCE DOOR, COMPLY WITH REQUIREMENTS IN THIS SECTION. <br />1. DOOR HARDWARE SETS: PROVIDE QUANTITY, ITEM, SIZE, FINISH OR COLOR INDICATED, AND NAMED MANUFACTURERS' <br />PRODUCTS, <br />2. SEQUENCE OF OPERATION: PROVIDE ELECTRIFIED DOOR HARDWARE FUNCTION, SEQUENCE OF OPERATION, AND <br />INTERFACE WITH OTHER BUILDING CONTROL SYSTEMS INDICATED. <br />3, OPENING -FORCE REQUIREMENTS: <br />a. EGRESS DOORS: NOT MORE THAN 15 LBF TO RELEASE THE LATCH AND NOT MORE THAN 30 LBF TO SET THE DOOR IN MOTION <br />AND NOT MORE THAN 15 LBF TO OPEN THE DOOR TO ITS MINIMUM REQUIRED WIDTH. <br />b. ACCESSIBLE INTERIOR DOORS: NOT MORE THAN 5 LBF TO FULLY OPEN DOOR. <br />D. DESIGNATIONS: REQUIREMENTS FOR DESIGN, GRADE, FUNCTION, FINISH, SIZE, AND OTHER DISTINCTIVE QUALITIES OF EACH <br />TYPE OF ENTRANCE DOOR HARDWARE ARE INDICATED IN "ENTRANCE DOOR HARDWARE SETS" ARTICLE. PRODUCTS ARE <br />IDENTIFIED BY USING ENTRANCE DOOR HARDWARE DESIGNATIONS AS FOLLOWS: <br />1. NAMED MANUFACTURERS' PRODUCTS: MANUFACTURER AND PRODUCT DESIGNATION ARE LISTED FOR EACH DOOR <br />HARDWARE TYPE REQUIRED FOR THE PURPOSE OF ESTABLISHING MINIMUM REQUIREMENTS. MANUFACTURERS' NAMES ARE <br />ABBREVIATED IN "ENTRANCE DOOR HARDWARE SETS" ARTICLE. <br />2 REFERENCES TO BHMA STANDARDS: PROVIDE PRODUCTS COMPLYING WITH THESE STANDARDS AND REQUIREMENTS FOR <br />DESCRIPTION, QUALITY, AND FUNCTION. <br />112 GLAZING <br />A. GLAZING: COMPLY WITH SECTION 038000 "GLAZING." <br />B. GLAZING GASKETS: MANUFACTURER'S STANDARD SEALED -CORNER PRESSURE -GLAZING SYSTEM( OF BLACK, RESILIENT <br />ELASTOMERIC GLAZING GASKETS, SETTING BLOCKS, AND SHIMS OR SPACERS. <br />C. GLAZING SEALANTS: AS RECOMMENDED BY MANUFACTLiRER. <br />D. SEALANTS USED INSIDE THE WEATHERPROOFING SYSTEM SHALL HAVE A VOO CONTENT OF 250 GIL. <br />1.13 FABRICATION <br />A. FABRICATION OF MATERIAL APJD SYSTEM TO 3E BY MAtdL;F,= CrURER. <br />B. FORM OR EXTRUDE ALUMINUM SHAPES BEFORE ! IN!SHING. <br />C. WELL) IN CONCEALED LOCATIONS TO GREATEST EXTENT POSSIBLE TO AMMiZE DISTORTION OR DISCOLORATION OF FINISH. <br />REMOVE WELD SPATTER AiND WELDING OXIDES FROM EXPOSED SURFACES BY DESCALING OR GRINDING. <br />D. FABRICATE COMPONENTS THAT, WHEN ASSEMBLED, HAVE THE FOLLOV'IiNG CHARACTERISTICS: <br />1. PROF iLEES THAT ARE SHARP, STRA.IGHT.AND FREE OF DEFECTS OR DEFORMATIONS. <br />2. ACCURATELY FITTED JOINTS WITH ENDS COPED OR MITERED. <br />3. PHYSICAL AND THERMAL ISOLATION OF GLAZING FROM FRAMING MEMBERS. <br />4. ACCOMMODATIONS FOR THERMAL AND MECHANICAL MOVEMENTS OF GLAZING AND FRAMING TO MAINTAIN REQUIRED <br />GLAZING EDGE CLEARANCES. <br />5. PROVISIONS FOR FIELD REPLACEMENT OF GLAZING FROM EXTERIOR. <br />6. FAST, ENERS, ANCHORS, AND CONNECTION DEVICES THAT ARE CONCEALED FROM VIEWTO GREATEST EXTENT POSSIBLE. <br />E. MECI-lAMCALLY GLAZED FRAMING MIEMBERS: FABRICATE FOR FLUSH GLAZING WITHOUT PROJECTING STOPS. <br />F. ENTRANCE DOOR FRAMES: REINFORCE AS REQUIRED TO SUPPORT LOADS IMPOSED BY DOOR OPERATION AND FOR <br />INSTALLING ENTRANCE DOOR HARDWARE. <br />G. ENTRANCE DOORS: REINFORCE DOORS AS REQUIRED FOR INSTALLING ENTRANCE DOOR HARDWARE. <br />H. ENTRANCE DOOR HARDWARE INSTALLATION: FACTORY INSTALL ENTRANCE DOOR HARDWARE TO THE GREATEST EXTENT <br />POSSIBLE, CUT, DRILL, AND TAP FOR FACTORY -INSTALLED ENTRANCE DOOR HARDWARE BEFORE APPLYING FINISHES. <br />I. AFTER FABRICATION, CLEARLY MARK COMPONENTS TO IDENTIFY THEIR LOCATIONS IN PROJECT ACCORDING TO SHOP <br />DRAWINGS. <br />1.14 ALUMINUM FINISHES <br />A. CLASS 1 CLEAR ANODIC FINISH: EXTERIOR STOREFRONT FRAMING AND ACCESSORIES. <br />B. CLASS 2 CLEAR ANODIC FINISH: INTERIOR STOREFRONT FRAMING. <br />1.15 INSTALLATION <br />A. GENERAL: <br />1, COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. <br />2. DO NOT INSTALL DAMAGED COMPONENTS. <br />3. FIT JOINTS TO PRODUCE HAIRLINE JOINTS FREE OF BURRS AND DISTORTION. <br />4. RIGIDLY SECURE NON -MOVEMENT JOINTS. <br />5. INSTALL ANCHORS WITH SEPARATORS AND ISOLATORS TO PREVENT METAL CORROSION AND ELECTROLYTIC <br />DETERIORATION AND TO PREVENT IMPEDING MOVEMENT OF MOVING JOINTS. <br />6. SEAL PERIMETER AND OTHER JOINTS WATERTIGHT UNLESS OTHERWISE INDICATED. <br />B. METAL PROTECTION: <br />1. WHERE ALUMINUM IS IN CONTACT WITH DISSIMILAR METALS, PROTECT AGAINST GA.LVA,NIC ACTION 8Y PAINTING CONTACT <br />SURFACES WITH MATERIALS RECOMMENDED BY MAMJFACTt1RER FOR THIS PURPOSE OR SY INSTALLING NONCONDUCTIVE <br />SPACERS. <br />2, INHERE .ALUMINUPP IS !N CONTACT WITH CONCRETE OR MASONRY, PROTECT AGAINST CORROSION By PAINTING CONTACT <br />SURFACES WITH BITUMINOUS PAINT. <br />C. USE CCNJTRNUOUS, FULL DEPTH AUJPJiP>IUMISILLS WITH VERTICAL LEG AT INTERIOR FACE AND P,NGLED DRIP EDGE AT <br />EXTERIOR. <br />1, SET SILL MEMBERS AND FLASHING IN FULL SEALA14T BED AS SPECIFIED IN SECTION 079200 "JOINT SEALANTS" TO PRODUCE <br />WE.ATHERTIGHT INSTALLATION. <br />D. INSTALL COMPONENTS PLUMB AND TRUE IN ALIGNMENT WITH ESTABLISHED LINES AND GRADES. <br />E. INSTALL GLAZING AS SPECIFIED IN SECTION 088000 "GLAZING." <br />F ENTRANCE DOORS: INSTALL DOORS TO PRODUCE SMOOTH OPERATION Al TIGHT FIT AT CONTACT POINTS. <br />i. EXTERIOR DOORS: iNSTA.LL TO PRODUCE VVEA. T HER T iGHT EPNCLOSIRE .AND TIGHT FIT AT WEATHER STRIPPING <br />2. INTERIOR DOORS: INSTALL CONTINUOUS SILENCERS ALONG FRAME. <br />3. FIELD -INSTALLED ENTRANCE DOOR HARDWARE: INSTALL SURFACE -MOUNTED ENTRANCE DOOR HARDWARE ACCORDING TO <br />ENTRANCE DOOR HARDWARE MANUFACTURERS' WRITTEN INSTRUCTIONS USING CONCEALED FASTENERS TO GREATEST <br />EXTENT POSSIBLE. <br />SECTION 087100 - DOOR HARDWARE <br />1.1 SUMMARY <br />A. THIS SECTION INCLUDES COMMERCIAL DOOR HARDWARE FOR SWINGING DOORS, <br />B. DOOR HARDWARE INCLUDES, BUT IS NOT NECESSARILY LIMITED TO, THE FOLLOWING: <br />1. MECHANICAL DOOR HARDWARE. <br />2. ELECTROMECHANICAL DOOR HARDWARE, POWER SUPPLIES, BACK-UPS AND SURGE PROTECTION. <br />3. AUTOMATIC OPERATORS. <br />4. CYLINDERS SPECIFIED FOR DOORS IN OTHER SECTIONS. <br />C. RELATED SECTIONS <br />1. DIVISION 08 SECTION "HOLLOW METAL DOORS AND FRAMES". <br />2. DIVISION 08 SECTION "ALUMINUM -FRAMED ENTRANCES AND STOREFRONTS". <br />3. DIVISION 08 SECTION "CLAD WOOD DOORS". <br />D. STANDARDS: ALL HARDWARE SPECIFIED HEREIN SHALL COMPLY WITH THE FOLLOWING INDUSTRY STANDARDS: <br />1. ANSI/BHMA CERTIFIED PRODUCT STANDARDS - A156 SERIES <br />2. UL10C - POSITIVE PRESSURE FIRE TESTS OF DOOR ASSEMBLIES <br />1.2 SUBMITTALS <br />A. REFER TO SECTION 013300 FOR SUBMITTAL REQUIREMENTS. <br />B. PRODUCT DATA: MANUFACTURER'S PRODUCT DATA SHEETS INCLUDING INSTALLATION DETAILS, MATERIAL DESCRIPTIONS, <br />DIMENSIONS OF INDIVIDUAL COMPONENTS AND PROFILES, OPERATIONAL DESCRIPTIONS AND FINISHES. <br />C. DOOR HARDWARE SCHEDULE: PREPARED BY OR UNDER THE SUPERVISION OF SUPPLIER, DETAILING FABRICATION AND <br />ASSEMBLY OF DOOR HARDWARE, AS WELL AS PROCEDURES AND DIAGRAMS, COORDINATE THE FINAL DOOR HARDWARE <br />SCHEDULE WITH DOORS, FRAMES, AND RELATED WORK TO ENSURE PROPER SIZE, THICKNESS, HAND, FUNCTION, AND FINISH <br />OF DOOR HARDWARE. <br />D. OPERATING AND MAINTENANCE MANUALS: PROVIDE MANUFACTURERS OPERATING AND MAINTENANCE MANUALS FOR EACH <br />ITEM COMPRISING THE COMPLETE DOOR HARDWARE INSTALLATION IN QUANTITY AS REQUIRED IN DIVISION 01, CLOSEOUT <br />SUBMITTALS. THE IVANUAL TO INCLUDE THE NAME, ADDRESS, AND CONTACT INFORMATION OF THE MANUFACTURERS <br />PROVIDING THE HARDWARE AND THEIR NEAREST SERVICE REPRESENTATIVES. THE FINAL COPIES DELIVERED AFTER <br />COMPLETION OF THE INSTALLATION TEST TO INCLUDE "AS BUILT" MODIFICATIONS MADE DURING INSTALLATION, CHECKOUT, <br />D <br />.AND ACCEPTANCE <br />TANCE <br />E. WARRANTIES AND MAINTENANCE: SPECIAL WARRANTIES AND MAINTENANCE AGREEMENTS SPECIFIED IN THIS SECTION. <br />1.3 QUALITY ASSURANCE <br />A. MANUFACTURERS QUALIFICATIONS: ENGAGE QUALIFIED MANUFACTURERS WITH A MINIMUM 5 YEARS OF DOCUMENTED <br />EXPERIENCE IN PRODUCING HARDWARE AND EQUIPMENT SIMILAR TO THAT INDICATED FOR THIS PROJECT AND THAT HAVE A <br />PROVEN RECORD OF SUCCESSFUL IN-SERVICE PERFORMANCE. <br />B. INSTALLER QUALIFICATIONS: INSTALLERS, TRAINED BY THE PRIMARY PRODUCT MANUFACTURERS, WITH A MINIMUM 3 <br />YEARS DOCUMENTED EXPERIENCE INSTALLING BOTH STANDARD AND ELECTRIFIED BUILDERS HARDWARE SIMILAR IN <br />MATERIAL, DESIGN, AND EXTENT TO THAT INDICATED FOR THIS PROJECT AND WHOSE WORK HAS RESULTED IN CONSTRUCTION <br />WITH A RECORD OF SUCCESSFUL IN-SERVICE PERFORMANCE. <br />C. SOURCE LIMITATIONS: OBTAIN EACH TYPE AND VARIETY OF DOOR HARDWARE SPECIFIED IN THIS SECTION FROM A SINGLE <br />SOURCE, QUALIFIED SUPPLIER UNLESS OTHERWISE INDICATED. <br />D. REGULATORY REQUIREMENTS: COMPLY WITH NFPA 70, NFPA 8Q NFPA 101 AND ANSI A117.1 REQUIREMENTS AND <br />GUIDELINES AS DIRECTED IN THE MODEL BUILDING CODE. <br />E. EACH UNIT TO BEAR THIRD PARTY PERMANENT LABEL DEMONSTRATING COMPLIANCE WITH THE REFERENCED STANDARDS. <br />F. KEYING: GC TO COORDINATE KEYING WITH OWNER. <br />G. PRE -SUBMITTAL CONFERENCE CALL: AS REQUIRED, CONDUCT COORDINATION CONFERENCE CALL WITH ATTENDANCE BY <br />REPRESENTATIVES OF SUPPLIER(S), INSTALLER(S), AND CONTRACTOR(S) TO REVIEW PROPER METHODS AND THE <br />PROCEDURES FOR RECEIVING, HANDLING, AND INSTALLING DOOR HARDWARE. <br />H. AT COMPLETION OF INSTALLATION, PROVIDE WRITTEN DOCUMENTATION THAT COMPONENTS WERE APPLIED TO <br />MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS AND ACCORDING TO APPROVED SCHEDULE. <br />1.4 DELIVERY, STORAGE, AND HANDLING <br />A. INVENTORY DOOR HARDWARE ON RECEIPT AND PROVIDE SECURE LOCK -UP AND SHELVING FOR DOOR HARDWARE <br />DELIVERED TO PROJECT SITE. DO NOT STORE ELECTRONIC ACCESS CONTROL HARDWARE, SOFTWARE OR ACCESSORIES AT <br />PROJECT SITE WITHOUT PRIOR AUTHORIZATION. <br />B. TAG EACH ITEM OR PACKAGE SEPARATELY WITH IDENTIFICATION RELATED TO THE FINAL DOOR HARDWARE SCHEDULE, <br />AND INCLUDE BASIC INSTALLATION INSTRUCTIONS WITH EACH ITEM OR PACKAGE. <br />C. DELIVER, AS APPLICABLE, PERMANENT KEYS, CYLINDERS, CORES, ACCESS CONTROL CREDENTIALS, SOFTWARE AND <br />RELATED ACCESSORIES DIRECTLY TO OWNER VIA REGISTERED MAIL OR OVERNIGHT PACKAGE SERVICE. INSTRUCTIONS FOR <br />DELIVERY TO THE OWNER SHALL BE ESTABLISHED AT THE "KEYING CONFERENCE". <br />15 COORDINATION <br />A. TEMPLATES: OBTAIN AND DISTRIBUTE TO THE PARTIES INVOLVED TEMPLATES FOR DOORS, FRAMES, AND OTHER WORK <br />SPECIFIED TO BE FACTORY PREPARED FOR INSTALLING STANDARD AND ELECTRIFIED HARDWARE. CHECK SHOP DRAWINGS OF <br />OTHER WORK TO CONFIRM THAT ADEQUATE PROVISIONS ARE MADE FOR LOCATING AND INSTALLING HARDWARE TO COMPLY <br />WITH INDICATED REQUIREMENTS. <br />S. DOOR HARDWARE AND ELECTRICAL CONNECTIONS: COORDINATE THE LAYOUT AND INSTALLATION OF SCHEDULED <br />ELECTRIFIED DOOR HARDWARE AND RELATED ACCESS CONTROL EQUIPMENT WITH REQUIRED CONNECTIONS TO SOURCE <br />POWER JUNCTION BOXES, LOW VOLTAGE POWER SUPPLIES, DETECTION AND MONITORING HARDWARE, AND FIRE AND <br />DETECTION ALARM SYSTEMS. <br />C. DOOR AND FRAME PREPARATION: RELATED DIVISION 08 SECTIONS (STEEL, ALUMINUM AND WOOD) DOORS AND <br />CORRESPONDING FRAMES ARE TO BE PREPARED, REINFORCED AND PRE -WIRED (IF APPLICABLE) TO RECEIVE THE <br />INSTALLATION OF THE SPECIFIED ELECTRIFIED, MONITORING, SIGNALING AND ACCESS CONTROL SYSTEM HARDWARE WITHOUT <br />ADDITIONAL IN -FIELD MODIFICATIONS. <br />1.6 WARRANTY <br />A. GENERAL WARRANTY: REFERENCE DIVISION Ot, GENERAL REQUIREMENTS. SPECIAL WARRANTIES SPECIFIED IN THIS <br />ARTICLE SHALL NOT DEPRIVE OWNER OF OTHER RIGHTS OWNER MAY HAVE UNDER OTHER PROVISIONS OF THE CONTRACT <br />DOCUMENTS AND SHALL BE IN ADDITION TO, AND RUN CONCURRENT WITH, OTHER WARRANTIES MADE BY CONTRACTOR LINDER <br />REQUIREMENTS OF THE CONTRACT DOCUMENTS. <br />B WARRANTY PERIOD: WRITTEN WARRANTY, EXECUTED BY MANUFACTURER(S), AGREEING TO REPAIR OR REPLACE <br />COMPONENTS OF STANDARD AND ELECTRIFIED DOOR HARDWARE THAT FAILS IN MATERIALS OR WORKMANSHIP WITHIN <br />SPECIFIED WARRANTY PERIOD AFTER FINAL ACCEPTANCE BY THE OWNER. FAILURES INCLUDE, BUT ARE NOT LIMITED TO, THE <br />FOLLOWING: <br />1. STRUCTURAL FAILURES INCLUDING EXCESSIVE DEFLECTION, CRACKING, OR BREAKAGE. <br />2. FAULTY OPERATION OF THE HARDWARE. <br />3 DETERIORATION OF METALS, METAL FINISHES, AND OTHER MATERIALS BEYOND NORMAL WEATHERING, <br />4. ELECTRICAL COMPONENT D AND FAILURES WITHIN THE SYSTEMS OPERATION. <br />E T DEFECTS A <br />C. S T ANDARD WARRANTY PERIOD: YEAR FROM DATE OF SUBSTANTIAL COMPLETION UNLESS OTHERWISE INDICATED. <br />0 ONE <br />D. SPECIAL WARRANTY PERIODS: <br />1. TEN YEARS F . OR MORTISE LOCKS AND LATHES. <br />2. FIVE YEARS FOR EXIT HARDWARE. <br />3. TWENTY FIVE YEARS FOR MANUAL SURFACE DOOR CLOSERS. <br />4. TWO YEARS FOR ELECTROMECHANICAL DOOR HARDWARE. <br />1.7 MAINTENANCE SERVICE <br />A. MAINTENANCE TOOLS AND INSTRUCTIONS: FURNISH A COMPLETE SET OF SPECIALIZED TOOLS AND MAINTENANCE <br />INSTRUCTIONS AS NEEDED FOR OWNER'S CONTINUED ADJUSTMENT, MAINTENANCE, AND REMOVAL AND REPLACEMENT OF <br />DOOR HARDWARE. <br />B. CONTINUING SERVICE: BEGINNING AT SUBSTANTIAL COMPLETION, AND RUNNING CONCURRENT WITH THE SPECIFIED <br />WARRANTY PERIOD, PROVIDE CONTINUOUS (6) MONTHS FULL MAINTENANCE INCLUDING REPAIR AND REPLACEMENT OF WORN <br />OR DEFECTIVE COMPONENTS, LUBRICATION, CLEANING, AND ADJUSTING AS REQUIRED FOR PROPER DOOR OPENING <br />OPERATION. PROVIDE PARTS AND SUPPLIES AS USED IN THE MANUFACTURE AND INSTALLATION OF ORIGINAL PRODUCTS. <br />1.8 SCHEDULED DOOR HARDWARE <br />A. GENERAL: PROVIDE DOOR HARDWARE FOR EACH DOOR TO COMPLY WITH REQUIREMENTS IN DOOR HARDWARE SETS AND <br />EACH REFERENCED SECTION THAT PRODUCTS ARE TO BE SUPPLIED UNDER. <br />1. DESIGNATIONS: REQUIREMENTS FOR QUANTITY, ITEM, SIZE, FINISH OR COLOR, GRADE, FUNCTION, AND OTHER DISTINCTIVE <br />QUALITIES OF EACH TYPE OF DOOR HARDWARE ARE INDICATED IN THE DOOR HARDWARE SETS. PRODUCTS ARE IDENTIFIED BY <br />USING DOOR HARDWARE DESIGNATIONS. <br />B. NAMED MANUFACTURER'S PRODUCTS: PRODUCT DESIGNATION AND MANUFACTURER ARE LISTED FOR EACH DOOR <br />HARDWARE TYPE REQUIRED FOR THE PURPOSE OF ESTABLISHING REQUIREMENTS. MANUFACTURERS' NAMES ARE <br />ABBREVIATED IN THE DOOR HARDWARE SCHEDULE. <br />1. ACCEPTABLE PRODUCTS/MANUFACTURERS: REFER TO DOOR HARDWARE SCHEDULE ON DRAWINGS. <br />1.9 HANGING DEVICES <br />A HINGES: ANSI/BHMP, A156.1 CERTIFIED BUTT HINGES WITH NUMBER OF HINGE KNUCKLES AS SPECIFIED IN THE DOOR <br />HARDWARE SETS. <br />B. CONTINUOUS GEARED HINGES: ANSI/BHMA A156.26 CERTIFIED CONTINUOUS GEARED HINGE WITH MINIMUM 0.120-INCH THICK <br />EXTRUDED 6060 T6 ALUMINUM ALLOY HINGE LEAVES AND A MINIMUM OVERALL WIDTH OF 4 INCHES. <br />1.10 DOOROPER.ATINGTRIM <br />A. FLUSH BOLTS AND SURFACE BOLTS: ANSI/BHMA A156.3 AND A156.16, GRADE 1, CERTIFIED AUTOMA71iC, SELF -LATCHING, AND <br />MANUAL FLUSH BOLTS AND SURFACE BOLTS. <br />1.11 CYLINDERS AND KEYING <br />A. GENERAL: CYLINDER MANUFACTURER TO HAVE MINIMUM (10) YEARS OF EXPERIENCE DESIGNING SECURED MASTER KEY <br />SYSTEMS AND HAVE ON RECORD A PUBLISHED SECURITY KEYING SYSTEM POLICY. <br />B. SOURCE LIMITATIONS: OBTAIN EACH TYPE OF KEYED CYLINDER AND KEYS FROM THE SAME SOURCE MANUFACTURER AS <br />LOCKSETS AND EXIT DEVICES, UNLESS OTHERWISE INDICATED. <br />C. CYLINDERS: ORIGINAL MANUFACTURER CYLINDERS COMPLYING WITH THE FOLLOWING: <br />1. MORTISE TYPE: THREADED CYLINDERS WITH RINGS AND STRAIGHT- OR CLOVER -TYPE CAM. <br />2, RIM TYPE: CYLINDERS WITH BACK PLATE, FLAT -TYPE VERTICAL OR HORIZONTAL TAILPIECE, AND RAISED TRIM RING. <br />3. BORED -LOCK TYPE: CYLINDERS WITH TAILPIECES TO SUIT LOCKS. <br />4. MORTISE AND RIM CYLINDER COLLARS TO BE SOLID AND RECESSED TO ALLOW THE CYLINDER FACE TO BE FLUSH AND BE <br />FREE SPINNING WITH MATCHING FINISHES. <br />5. KEYWAY: MANUFACTURER'S STANDARD. <br />D. KEYING SYSTEM: EACH TYPE OF LOCK AND CYLINDERS TO BE FACTORY KEYED. COORDINATE KEYING WITH OWNER. <br />E. KEY QUANTITY: VERIFY QUANTITY WITH OWNER. <br />SECTION 087100 - DOOR HARDWARE (CONTINUED) <br />F. CONSTRUCTION KEYING: PROVIDE CONSTRUCTION MASTER KEYED CYLINDERS OR TEMPORARY KEYED <br />CONSTRUCTION CORES WHERE SPECIFIED. PROVIDE CONSTRUCTION MASTER KEYS IN QUANTITY AS REQUIRED <br />BY PROJECT CONTRACTOR. REPLACE CONSTRUCTION CORES WITH PERMANENT CORES, FURNISH PERMANENT <br />CORES FOR INSTALLATION AS DIRECTED BY OWNER. <br />G. KEY REGISTRATION LIST: PROVIDE KEYING TRANSCRIPT LIST TO OWNER'S REPRESENTATIVE IN THE PROPER <br />FORMAT FOR IMPORTING INTO KEY CONTROL SOFTWARE. <br />H. KEY CONTROL SOFTWARE: PROVIDE ONE NETWORK VERSION OF "KEY WIZARD" BRANDED KEY MANAGEMENT <br />SOFTWARE PACKAGE THAT INCLUDES ONE YEAR OF TECHNICAL SUPPORT AND UPGRADES TO SOFTWARE AT NO <br />CHARGE. PROVIDE FACTORY KEY SYSTEM FORMATTED FOR IMPORTING INTO "KEY WIZARD" SOFTWARE. <br />1,12 MECHANICAL LOCKS AND LATCHING DEVICES <br />A. MORTISE LOCKSETS, GRADE 1 (HEAVY DUTY): ANSI/BHMA A156.13, SERIES 1000, OPERATIONAL GRADE 1 CERTIFIED MORTISE <br />LOCKSETS FURNISHED IN THE FUNCTIONS AS SPECIFIED IN THE HARDWARE SEES. l <br />B. CYLINDRICAL LOCKSETS, GRADE 1 (COMMERCIAL DUTY): ANSI/BHMA A156.2, SERIES 4000, GRADE 1 CERTIFIED CYLINDRICAL <br />(BORED) LOCKSETS FURNISHED IN THE FUNCTIONS AS SPECIFIED IN THE HARDWARE SETS. <br />C. LOCK TRIM DESIGN: AS SPECIFIED IN HARDWARE SETS. <br />1.13 STAND ALONE ACCESS CONTROL LOCKING DEVICES <br />A. STAND ALONE INTEGRATED ACCESS CONTROL LOCKETS: INTERNAL, BATTERY -POWERED, SELF-CONTAINED ANSI GRADE 1 <br />MORTISE OR CYLINDRICAL LOCK CONSISTING OF ELECTRONICALLY MOTOR DRIVEN LOCKING MECHANISM, INTEGRATED <br />KEYPAD, PROXIMITY CARD READER, OR KEYPAD/PROXIMITY CARD READER COMBINATION, AND SPECIFIED ELECTRONIC <br />PROGRAMMING ACCESSORIES. <br />1.14 LOCK AND LATCH STRIKES <br />A. STRIKES: PROVIDE MANUFACTURER'S STANDARD STRIKE WITH STRIKE BOX FOR EACH LATCH OR LOCK BOLT, WITH CURVED <br />LIP EXTENDED TO PROTECT FRAME, FINISHED TO MATCH DOOR HARDWARE SET, UNLESS OTHERWISE INDICATED, AND AS <br />FOLLOWS: <br />p T' N <br />1. FLAT -LIP STRIKES: FOR LOCKS WITH THREE-PIECE ANTIFRICTION LATCHBOLTS AS RECOMMENDED BY MANUFACTURER. <br />2, ALUMINUM -FRAME STRIKE BOX: PROVIDE MANUFACTURER'S SPECIAL STRIKE BOX FABRICATED FOR ALUMINUM FRAMING. <br />B. STANDARDS: COMPLY WITH THE FOLLOWING: <br />1. STRIKES FOR MORTISE LOCKS AND LATCHES: BHMA A156.13. <br />2. STRIKES FOR BORED LOCKS AND LATCHES: BHMA A156.2. <br />3. STRIKES FOR AUXILIARY DEADLOCKS: BHP""AA156.5. <br />4. DUSTPROOF STRIKEC: BHMA A156.16. <br />1.15 CONVENTIONAL EXIT DEVICES <br />A. GENERAL REQUIREMENTS: ALL EXIT DEVICES SPECIFIED HEREIN SHALL MEET OR EXCEED THE FOLLOWING CRITERIA: <br />1. AT DOORS NOT REQUIRING AFIRE RATING, PROVIDE DEVICES COMPLYING WITH NFPA 101 AND LISTED AND LABELED FOR <br />"PANIC HARDWARE" ACCORDING TO UI.305. PROVIDE PROPER FASTENERS AS REQUIRED BY MANUFACTURER INCLUDING SEX <br />NUTS AND BOLTS AT OPENINGS SPECIFIED IN THE HARDWARE SETS. <br />2. WHERE EXIT DEVICES ARE REQUIRED ON FIRE RATED DOORS, PROVIDE DEVICES COMPLYING WITH NFPA 80 AND WITH UL <br />LABELING INDICATING "FIRE EXIT HARDWARE". PROVIDE DEVICES WITH THE PROPER FASTENERS FOR INSTALLATION AS <br />TESTED AND LISTED BY UL. CONSULT MANUFACTURER'S CATALOG AND TEMPLATE BOOK FOR SPECIFIC REQUIREMENTS. <br />a. FIRE EXIT REMOVABLE MULLIONS: PROVIDE KEYED REMOVABLE MULLIONS FOR USE WITH FIRE EXIT DEVICES COMPLYING <br />WITH NFPA 80 THAT ARE LISTED AND LABELED BY A TESTING AND INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING <br />JURISDICTION, FOR FIRE AND PANIC PROTECTION, BASED ON TESTING ACCORDING TO UL 305 AND NFPA 252. MULLIONS TO BE <br />USED ONLY WITH EXIT DEVICES FOR WHICH THEY HAVE BEEN TESTED. <br />3. EXCEPT ON FIRE RATED DOORS, PROVIDE EXIT DEVICES WITH HEX KEY DOGGING DEVICE TO HOLD THE PUSHBAR AND <br />LATCH IN A RETRACTED POSITION. PROVIDE OPTIONAL KEYED CYLINDER DOGGING ON DEVICES WHERE SPECIFIED IN <br />HARDWARE SETS. <br />4. FLUSH END CAPS: PROVIDE HEAVY WEIGHT IMPACT RESISTANT FLUSH END CAPS MADE OF ARCHITECTURAL METAL IN THE <br />SAME FINISH AS THE DEVICES AS IN THE HARDWARE SETS. PLASTIC END CAPS WILL NOT BE ACCEPTABLE. <br />5. LEVER OPERATING TRIM: WHERE EXIT DEVICES REQUIRE LEVER TRIM, FURNISH MANUFACTURER'S HEAVY DUTY TRIM WITH <br />COLD FORGED ESCUTCHEONS, BEVELED EDGES, AND FOUR THREADED STUDS FOR THRU-BOLTS. <br />a. LOCK TRIM DESIGN: AS INDICATED IN HARDWARE SETS, PROVIDE FINISHES AND DESIGNS TO MATCH THAT OF THE <br />SPECIFIED LOCKSETS. PROVIDED FREE -WHEELING TYPE TRIM WHERE INDICATED. <br />b. WHERE FUNCTION OF EXIT DEVICE REQUIRES A CYLINDER, PROVIDE AN INTERCHANGEABLE CORE TYPE KEYED CYLINDER <br />(RIM OR MORTISE) AS SPECIFIED IN HARDWARE SETS. <br />0. VERTICAL ROD EXIT DEVICES: PROVIDE AND INSTALL INTERIOR SURFACE AND CONCEALED VERTICAL ROD EXIT DEVICES AS <br />LESS BOTTOM ROD (LBR) UNLESS OTHERWISE INDICATED. <br />7. NARROW STILE APPLICATIONS: AT DOORS CONSTRUCTED WITH NARROW STILES. OR AS SPECIFIED IN HARDWARE SETS, <br />PROVIDE DEVICES DESIGNED FOR MAXIMUM 2" WIDE STILES, <br />8. DUMMY PUSH BAR: NONFUNCTiONING PUSH BAR MATCHING FUNCTIONAL PUSH BAR. <br />9. RAIL SIZING: PROVIDE EXIT DEVICE RAILS FACTORY SIZED FOR PROPER DOOR WIDTH APPLICATION. <br />10. THROUGH BOLT INSTALLATION: FOR EXIT DEVICES AND TRIM AS INDICATED IN DOOR HARDWARE SETS, <br />B. CONVENTIONAL PUSH RAIL EXIT DEVICES (HEAVY DUTY): ANSI/BHMA A156.3, GRADE 1 CERTIFIED PANIC AND FIRE EXIT <br />HARDWARE DEVICES FURNISHED IN THE FUNCTIONS SPECIFIED IN THE HARDWARE SETS. MOUNTING RAILS TO BE FORMED <br />FROM SMOOTH STAINLESS STEEL, BRASS OR BRONZE ARCHITECTURAL MATERIALS NO LESS THAN 0.072" THICK, WITH PUSH <br />RAILS A, MINIMUM OF 0.062" THICKNESS. PAINTED OR ALUMINUM METAL RAILS ARE NOT ACCEPTABLE. EXIT DEVICE LATCH TO BE <br />INVESTMENT CAST S T AIMLESS STEEL, PULLMAN TYPE, WITH DEADLOCK FEATURE. <br />1.16 DOOR CLOSERS <br />A. DOOR CLOSERS, SURFACE MOUNTED (LARGE BODY CAST IRON): ANSI/BHMA A156.4, GRADE 1 SURFACE MOUNTED, HEAVY <br />DUTY DOOR CLOSERS WITH COMPLETE SPRING POWER ADJUSTMENT, SIZES 1 THRU 6; AND FULLY OPERATIONAL ADJUSTABLE <br />ACCORDING TO DOOR SIZE, FREQUENCY OF USE, AND OPENING FORCE. <br />B. DOOR CLOSERS, SURFACE MOUNTED (HEAVY DUTY): ANSI/BHMA A156.4, GRADE 1 SURFACE MOUNTED, HEAVY DUTY DOOR <br />CLOSERS WITH COMPLETE SPRING POWER ADJUSTMENT, SIZES 1 THRU 6; AND FULLY OPERATIONAL ADJUSTABLE ACCORDING <br />TO DOOR SIZE. FREQUENCY OF USE, AND OPENING FORCE. <br />C. DOOR CLOSERS, SURFACE MOUNTED (COMMERCIAL DUTY): ANSI/BHMA 156.4, GRADE 1 CERTIFIED SURFACE MOUNTED, <br />INSTITUTIONAL_ GRADE D.^.OR CLOSERS WITH COMPLETE SPRING POWER ADJUSTMENT, SIZES 1 THRU 6; AND FULLY <br />OPERATIONAL ADJUSTABLE ACCORDING TO DOOR SIZE, FREQUENCY OF USE, AND OPENING FORCE. <br />1.17 AUTOMATIC DOOR OPERATORS <br />A. GENERAL: PROVIDE OPERATORS OF SIZE RECOMMENDED BY MANUFACTURER FOR DOOR SIZE, WEIGHT, AND MOVEMENT; <br />FOR CONDITION OF EXPOSURE; AND FOR COMPLIANCE WITH UL 325. COORDINATE OPERATOR MECHANISMS WITH DOOR <br />OPERATION, HINGES. AND ACTIVATION DEVICES. <br />1. FIRE -RATED DOORS: PROVIDE DOOR OPERATORS FOR FIRE -RATED DOOR ASSEMBLIES THAT COMPLY WITH NFPA 80 FOR <br />IRE -RATED DOOR COMPONENTS AND ARE LISTED AND LABELED <br />FN DBY A QUALIFIED TESTING AGENCY. <br />�^ <br />B. ELECTROMECHANICAL DOOR OPERATORS: SELF-CONTAINED UNIT POWERED BY PERMANENT MAGNET DC MOTOR WITH <br />C S <br />CLOSING SPEED CONTROLLED MECHANICALLY BY GEAR TRAIN, CONNECTIONS FOR POWER, ACTIVATION AND SAFETY DEVICE <br />WIRING, AND MANUAL OPERATiON INCLUDING SPRING CLOSING WHEN POWER IS OFF. <br />C. ELECTROHYDRAULIC DOOR OPERATORS: SELF-CONTAINED LOW-PRESSURE UNITS WITH RACK AND PINION DESIGN <br />CONTAINED WITHIN A CAST ALUMINUM HOUSING. DOOR CLOSING SPEED CONTROLLED BY INDEPENDENT HYDRAULIC <br />ADJUSTMENT VALVES IN THE SWEEP AND LATCH RANGE OF THE CLOSING CYCLE. OPERATOR IS TO PROVIDE CONVENTIONAL <br />DOOR CLOSER OPENING AND CLOSING FORCES UNLESS THE POWER OPERATOR MOTOR IS ACTIVATED. UNIT IS TO INCLUDE AN <br />ADJUSTABLE HYDRAULIC BACKCHECK VALVE TO CUSHION THE DOOR SPEED IF OPENED VIOLENTLY. NON -HANDED UNITS FOR <br />BOTH PUSH AND PULL SIDE APPLICATIONS. <br />D. BRACKETS AND REINFORCEMENTS: MANUFACTURER'S STANDARD, FABRICATED FROM ALUMINUM WITH NONFERROUS SHIMS <br />FOR ALIGNING SYSTEM COMPONENTS. E. STANDARD: CERTIFIED ANSI/BHMA A156.19. <br />1. PERFORMANCE REQUIREMENTS: <br />a. OPENING FORCE IF POWER FAILS: NOT MORE THAN 15 LBF REQUIRED TO RELEASE A LATCH IF PROVIDED, NOT MORE THAN <br />30 LBF REQUIRED TO MANUALLY SET DOOR IN MOTION, AND NOT MORE THAN 15 LBF REQUIRED TO FULLY OPEN DOOR. <br />b. ENTRAPMENT PROTECTION: NOT MORE THAN 15 LBF REQUIRED TO PREVENT STOPPED DOOR FROM CLOSING OR OPENING. <br />F. CONFIGURATION: SURFACE MOUNTED. DOOR OPERATORS TO CONTROL SINGLE SWINGING AND PAIR OF SWINGING DOORS. <br />G. OPERATION: POWER OPENING AND SPRING CLOSING OPERATION CAPABLE OF MEETING ANSI A117.1 ACCESSIBILITY <br />GUIDELINE. PROVIDE TIME DELAY FOR DOOR TO REMAIN OPEN BEFORE INITIATING CLOSING CYCLE AS REQUIRED BY <br />ANSI/BHMA A156.19. WHEN NOT IN AUTOMATIC MODE, DOOR OPERATOR TO FUNCTION AS MANUAL DOOR CLOSER WITH FULLY <br />ADJUSTABLE OPENING AND CLOSING FORCES, WITH OR WITHOUT ELECTRICAL POWER. <br />1. ON -OFF SWITCH TO CONTROL POWER TO BE KEY SWITCH OPERATED. <br />H. FEATURES: OPERATOR UNITS TO HAVE FULL FEATURE ADJUSTMENTS FOR DOOR OPENING AND CLOSING FORCE AND <br />SPEED, BACKCHECK, MOTOR ASSIST ACCELERATION FROM 0 TO 30 SECONDS, TIME DELAY, VESTIBULE INTERFACE DELAY, <br />OBSTRUCTION RECYCLE, AND HOLD OPEN TIME FROM 0 UP TO 30 SECONDS. <br />I. PROVIDE OUTPUTS AND RELAYS ON BOARD THE OPERATOR TO ALLOW FOR COORDINATION OF EXIT DEVICE LATCH <br />RETRACTION, ELECTRIC STRIKES, MAGNETIC LOCKS, CARD READERS, SAFETY AND MOTION SENSORS AND SPECIFIED <br />AUXILIARY CONTACTS, <br />J. ACTIVATION DEVICES: PROVIDE ACTIVATION DEVICES IN ACCORDANCE WITH ANSI/BHMA A156.19 STANDARD, FOR CONDITION <br />OF EXPOSURE INDICATED AND FOR LONG TERM, MAINTENANCE FREE OPERATION UNDER NORMAL TRAFFIC LOAD OPERATION. <br />COORDINATE ACTIVATION CONTROL WITH ELECTRIFIED HARDWARE AND ACCESS CONTROL INTERFACES. ACTIVATION <br />SWITCHES ARE STANDARD SPST, WITH OPTIONAL DPDT AVAILABILITY. <br />K. SIGNAGE: AS REQUIRED BY CITED ANSI!BHMA A156.19 STANDARD FOR THE TYPE OF OPERATOR. <br />1.18 ARCHITECTURAL TRIM <br />A. DOOR PROTECTIVE TRIM <br />1. GENERAL: DOOR PROTECTIVE TRIM UNITS TO BE OF TYPE AND DESIGN AS SPECIFIED BELOW OR IN THE HARDWARE SETS. <br />2. SIZE: FABRICATE PROTECTION PLATES (KICK, ARMOR, OR MOP) NOT MORE THAN 2" LESS THAN DOOR WIDTH (LDW) ON STOP <br />SIDE OF SINGLE DOORS Al" LDW ON STOP SIDE OF PAIRS OF DOORS, AND NOT MORE THAN 1" LESS THAN DOOR WIDTH ON <br />PULL SIDE. COORDNA T E AND PROVIDE PROPER WIDTH AND HEIGHT AS REQUIRED WHERE CONFLICTING HARDWARE DICTATES. <br />HEIGHT TO BE AS SPECIFIED IN THE HARDWARE SETS. <br />3. METAL PROTECTION PLATES: ANSI/BHMA A156.6 CERTIFIED METAL PROTECTION PLATES (KICK, ARMOR, OR MOP), BEVELED <br />ON FOUR EDGES (B4E), FABRICATED FROM THE FOLLOWING. <br />a. STAINLESS STEEL. 050-INCH THICK, WITH COUNTERSUNK SCREW HOLES (CSK). <br />4. FASTENERS: PROVIDEMANUFACTURER'S DESIGNATED FASTENER TYPE AS SPECIFIED IN THE HARDWARE SETS. <br />5, METAL DOOR EDGING: DOOR PROTECTION EDGING FABRICATED FROM A MINIMUM .050-INCH THICK METAL SHEET, FORMED <br />INTO AN ANGLE OR "U" CAP SHAPES, SURFACE OR MORTISED MOUNTED ONTO EDGE OF DOOR. PROVIDE APPROPRIATE LEG <br />OVERLAP TO ACCOUNT FOR PROTECTION PLATES AS REQUIRED. HEIGHT TO BE AS SPECIFIED IN THE HARDWARE SETS. <br />SECTION 087100 - DOOR HARDWARE (CONTINUED) <br />1.19 DOORSTOPS AND HOLDERS <br />A. DOORSTOPS AND BUMPERS: ANSI/BHMA A156.16, GRADE 1 CERTIFIED DOORSTOPS AND WALL BUMPERS. <br />B. OVERHEAD DOORSTOPS AND HOLDERS: ANSI/BHMA A156.6, GRADE! CERTIFIED OVERHEAD STOPS AND HOLDERS TO BE <br />SURFACE OR CONCEALED TYPES. <br />1.20 ARCHITECTURAL SEALS <br />A. GENERAL: THRESHOLDS, WEATHERSTRIPPING, AND GASKET SEALS TO BE OF TYPE AND DESIGN AS SPECIFIED BELOW OR <br />IN THE HARDWARE SETS. PROVIDE CONTINUOUS WEATHERSTRIP GASKETING ON EXTERIOR DOORS AND PROVIDE SMOKE, <br />LIGHT, OR SOUND GASKETING ON INTERIOR DOORS WHERE INDICATED. AT EXTERIOR APPLICATIONS PROVIDE NON- <br />CORROSIVE FASTENERS AND ELSEWHERE WHERE INDICATED. <br />B. SMOKE LABELED GASKETING: ASSEMBLIES COMPLYING WITH NFPA 105 THAT ARE LISTED AND LABELED BY A TESTING <br />AND INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, FOR SMOKE CONTROL RATINGS INDICATED, <br />BASED ON TESTING ACCORDING TO UL 17$4. <br />1. PROVIDE SMOKE LABELED PERIMETER GASKETING AT ALL SMOKE LABELED OPENINGS. <br />C. FIRE LABELED GASKETING: ASSEMBLIES COMPLYING WITH NFPA 80 THAT ARE LISTED AND LABELED BY .A TESTING AND <br />INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. FOR ril RATINGS INDICATED, BASED ON <br />TESTING ACCORDING TO UL-10C, <br />1. PROVIDE INTUMESCENT SEALS AS INDICATED TO MEET UL10C STANDARD FOP, POSITIVE PRESSURE FIRE TESTS OF GC0, <br />ASSEMBLIES, AND UBC 7-2, FIRE TESTS OF DOOR ASSEMBLIES. <br />D. SOUND -RATED GASKETING: ASSEMBLIES THAT ARE LISTED AND LABELED 811, A TESTINNG .AI`d0 INSPECTif�(. t::tNC'r, F-"- <br />SOUND RATINGS INDICATED, BASED ON TESTING ACCORDING TO ASTV. E 1408. <br />E. REPLACEABLE SEAL STRIPS: PROVIDE ONLY THOSE UNITS'NHERE RESILIENT OR FLEXIBLE SEAL,--; RirS AF2 EAS:LY <br />REPLACEABLE AND READILY AVAILABLE FROM STOCKS MAiNTAtiVED BY Pv1.ANUFk,'TUR4R. <br />1.21 ELECTRONIC ACCESSORIES <br />A. PUSH-BUTTON SWITCHES: INDUSTRIAL GRADc P610PAENTARY OR .ALTERi J,aTE CONT;,%C, 6;=.CK-LICK'"ED r: ISH sUTTC�NS <br />WITH STAINLESS -STEEL SWITCH ENCLOSURES, 12124 VDC B!-COLOR iLLU?."NATIOti si:iTABL.E FOR E! iFHER i=L1:Si-I CR. <br />SURFACE MOUNTING. <br />T .,r. _ <br />Y <br />7 i , <br />F TESTING , v) B. POWER SUPPLIES: PROVIDE NATIONALLY RECOGNIZED ES v� LABC4AT CRY � „ tD I< < � GT: �a. JC ,�L_ <br />SELECTABLE) FILTERED AND REGULATED POWER SUPPLIES, INCLUDE Ba. I ERY BACKUP �� Jh-H <br />F.r_.PA.R rI <br />EFT <br />CHARGING CAPABILITY IN ADDITION TO OPERATING THE DC LOAD IN EVENT OF LINE VOLTAGE FAILURE. PROVIDE THE LEAST <br />NUMBER OF UNITS, AT THE APPROPRIATE AMPERAGE LEVEL, SUFFICIENT TO EXCEED THE REQUIRED TOTAL DRAW FOR THE <br />SPECIFIED ELECTRIFIED HARDWARE AND ACCESS CONTROL EQUIPMENT <br />1.22 FABRICATION <br />A. FASTENERS: PROVIDE DOOR HARDWARE MANUFACTURED TO COMPLY °VITH PUBLISHED TLE MP+_ATES GENERALLY <br />PREPARED FOR MACHINE, WOOD, AND SHEET METAL SCREWS. PROVIDE SCREV'v5 ACCORDING TO 111~,NUFACTURERS <br />RECOGNIZED INSTALLATION STANDARDS FOR APPL (CATION INTENDED, <br />1.23 FINISHES <br />A. STANDARD: DESIGNATIONS USED IN THE HARDWARE SETS AND ELSEWHERE !NDICATE HARDWARE FINISHES COMPLYING <br />WITH ANSI/BHMA A156.14, INCLUDING COORDINATION WITH TRADITIONAL U.S. FiN{SHES INDICATED BY CER T AIN <br />MANUFACTURERS FOR THEIR PRODUCTS. <br />B. PROVIDE QUALITY OF FINISH, INCLUDING THICKNESS OF PLATING OR COATING fIF ANY), C OMPOSI?ION, HA.PF)l AND <br />OTHER QUALITIES COMPLYING WITH MANUFACTURER'S STANDARDS, BUT IN NO CASE LESS THAN SPECIFIED B'( <br />REFERENCED STANDARDS FOR THE APPLICABLE UNITS OF HARDWARE. <br />C. PROTECT MECHANICAL FINISHES ON EXPOSED SURFACES FROM DAMAGE BY APPLYING A STRIPPABLE, TEMPORARY <br />PROTECTIVE COVERING BEFORE SHIPPING. <br />1.24 EXAMINATION <br />A. EXAMINE SCHEDULED OPENINGS, WITH INSTALLER PRESENT. FOR COMPLIANCE WITH REQUIREMENTS FOR INSTALLATION <br />TOLERANCES, LABELED FIRE DOOR ASSEMBLY CONSTRUCTION, WALL AND FLOOR CONSTRUCTION, AND OTHER CONDITIONS <br />AFFECTING PERFORMANCE. <br />B. NOTIFY ARCHITECT OF ANY DISCREPANCIES OR CONFLICTS BETWEEN THE DCOR SCHEDULE. DOOR TYPES, DRAWINGS <br />AND SCHEDULED HARDWARE. PROCEED ONLY AFTER SUCH DISCREPANCIES OR CONFLICTS HAVE BEEN RESOLVED IN <br />WRITING. <br />1.25 PREPARATION <br />A. HOLLOW METAL DOORS AND FRAMES: COMPLY WITH Al A115 SERIES. <br />B. WOOD DOORS: COMPLY WITH ANSI/DHI A115-W SERIES. <br />1.26 INSTALLATION <br />A. INSTALL EACH ITEM OF MECHANICAL AND ELECTROMECHANICAL HARDWARE AND ACCESS CONTROL EQUIPMENT TC <br />COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND ACCORDING TO SPECIFICATIONS. <br />1. INSTALLERS ARE TO BE TRAINED AND CERTIFIED BY THE MANUFACTURER ON TH: PROPER INST„LATIU.J "dJD <br />ADJUSTMENT OF FIRE, LIFE SAFETY, AND SECURITY PRODUCTS !NCLUDI.\iG: HANNGING DE''!ICES; LOCKING'OC\+iCES: CLOSING <br />DEVICES; AND SEALS. <br />B. MOUNTING HEIGHTS: MOUNT DOOR HARDWARE UNITS AT HEIGHTS INDICATED IN FOLLCV'lING APPLiCABLE !'tJ6LICAT1010!3, <br />UNLESS SPECIFICALLY INDICATED OR REQUIRED TO COMPLY Y'viTH G, I_RPv ... REGULATIONS: i,. NS. i. STf„NDAh(D 6 , ELL uiVVhJ <br />AND FRAMES: DHI'S "RECOMMENDED LOCATIONS FOR ARCHITECTURAL PARl FCR STAPDARD ST`E.EL DC11-)iZS AND <br />FRAMES." <br />1. WOOD DOORS: DHI WDHS.3, "RECOMMENDED LOCATIONS FOR AP,CH!TECTLIRAL HARD'r1'ArRE FOR WOOD R.US;', DOORC " <br />2. WHERE INDICATED TO COMPLY WITH ACCESSIBILITY REQUIREMENTS. COk".9 � WiTH ANSI ,1,1'.71 "ACCESS-9iLITY <br />GUIDELINES FOR BUILDINGS AND FACILITIES." <br />3. PROVIDE BLOCKING IN DRYWALL PARTITIONS WHERE WALL STOPS OR OTHER WALL MOUNTED HARDV'''A E_ IS LOCATECI. <br />C. RETROFITTING: INSTALL DOOR HARDWARE TO COMPLY WITH MANUFACTURER'S PUBLISHED TEMPLATES AND WRITTEN <br />INSTRUCTIONS. WHERE CUTTING AND FITTING ARE REAL IREU ?0 INSTALL DOOR HARD(^!ARE ONTO ORINTO SURFACES THAT <br />ARE LATER TO BE PAINTED OR FINISHED IN ANOTHER WAY, COORDINATE REMOVAL, STORAGE, AND RENSTALLATON OF <br />SURFACE PROTECTIVE TRIM UNITS WITH FINISHING WORK SPECIFIED IN DIViSION 9 SECTIONS. DC NOT INSTALL SURFACE - <br />MOUNTED ITEMS UNTIL FINISHES HAVE BEEN COMPLETED ON SUBSTRATES INVOLVED. <br />D. THRESHOLDS: SET THRESHOLDS FOR EXTERIOR AND .ACOUSTICAL DOORS IN FiiLL BED OF SEALANT CO"APL:'(iNG WITH <br />REQUIREMENTS SPECIFIED IN DIVISION 7 SECTIOtr' "JOINT SEALANTS." <br />E. STORAGE: PROVIDE A SECURE LOCK UP FOR HARDWARE DELIVERED TO THE PROJECT BUT NOT YET ;..! STALLED <br />CONTROL THE HANDLING AND INSTALLATION OF HARDWARE !TEEMS SO THAT THE COMPLETION OF THE WORK -ILL NOT BE <br />DELAYED BY HARDWARE LOSSES BEFORE AND AFTER INSTALLATION, <br />1.27 ADJUSTING <br />A. INITIAL ADJUSTMENT: ADJUST AND CHECK EACH OPERATING ITEM OF DOOR HARDWARE AND EACH DOOR TO ENSURE <br />PROPER OPERATION OR FUNCTION OF EVERY UNIT, REPLACE UNITS THAT CANNOT BE ADJUSTED ?0 OPERATE F AS IN �T <br />ENDED <br />ADJUST DOOR CONTROL DEVICES TO COMPENSATE FOR FINAL OPERATION OF HEATING AND VENTILATING EQUIPMENT AND <br />TO COMPLY WITH REFERENCED ACCESSIBILITY REQUIREMENTS. <br />1.28 DEMONSTRATION <br />A. INSTRUCT OWNER'S MAINTENANCE PERSONNEL TO ADJUST, OPERATE, AND MAINTAIN MECHANICAL AND <br />ELECTROMECHANICAL DOOR HARDWARE. <br />1.29 DOOR HARDWARE SCHEDULE <br />A. REFER TO DRAWINGS FOR DOOR SCHEDULE AND HARDWARE SETS. <br />SECTION 088000 - GLAZING <br />1.1 SUMMARY <br />A. SECTION INCLUDES: <br />1. GLASS FOR INSULATED GLAZING UNITS. <br />1. SINGLE PANE GLAZING. <br />2. GLAZING SEALANTS AND ACCESSORIES. <br />1.2 DEFINITIONS <br />A. SEALED INSULATING GLASS UNIT SURFACES: <br />1. SURFACE NO. 1: EXTERIOR SURFACE OF OUTER LITE. <br />2. SURFACE NO. 2: INTERIOR SURFACE OF OUTER LITE. <br />3. SURFACE NO. 3: EXTERIOR SURFACE OF INNER LITE, <br />4. SURFACE NO. 4: INTERIOR SURFACE OF INNER LITE. <br />B. AIRSPACE: SPACE BETWEEN LITES OF AN INSULATING GLASS UNIT THAT CONTAINS DEHI'DR/ATE'' AIR. OR';'!'ER INERT <br />SPECIFIED GAS <br />1.3 COORDINATION <br />A. COORDINATE GLAZING CHANNEL DIMENSIONS TO PROVIDE NECESSARY SITE ON GUiSS, MN!MUM%I _DrE AND FACZ <br />CLEARANCES, AND ADEQUATE SEALANT THICKNESSES, WITH REASONABLE TOLERANCES. <br />1.4 ACTION SUBMITTALS <br />A. REFER TO SECTION 013300 FOR SUBMITTAL REQUiREMENTS, <br />B. PRODUCT DATA: FOR EACH TYPE OF PRODUCT. <br />C. GLASS SAMPLES: AS REQUESTED BY ARCHITECT. <br />D. GLAZING SCHEDULE: LIST GLASS TYPES AND THICKNESSES FOR EACH SIZE OPENING A1413, LOCATION. USE CAivIE <br />DESIGNATIONS INDICATED ON DRAWINGS. <br />E. DELEGATED -DESIGN SUBMITTAL: FOR GLASS INDICATED TO COMPLY WIT H PERFORMANCE REQUiREMENTS AND DESIGN <br />CRITERIA, INCLUDING ANALYSIS DATA SIGNED AND SEALED BY "T"r!E QUALIFIED PROFESSIONAL ENGINEER RESPONSIBLE F-OR <br />THEIR PREPARATION. <br />1.5 INFORMATIONAL SUBMITTALS <br />A. PRECONSTRUCTION ADHESION AND COMPATIBILiTY TEST REPORT. <br />1.6 QUALITY ASSURANCE <br />A. MANUFACTURER'S QUALIFICATIONS: MINIMUM OF 5 YEARS EXPERIENCE MANUFACTURING SOLAR CONTROL COATED <br />GLASS. <br />B. FABRICATOR'S QUALIFICATIONS: MINIMUM OF 5 YEARS' EXPERIENCE MANUFACTURING SEALED INSULATING GLASS UNITS <br />MEETING ASTM E 2190, CLASS CBA AND CERTIFIED BY MANUFA.0 T URER. <br />D. SEALANT TESTING AGENCY QUALIFICATIONS: AN INDEPENDENT TESTING AGENCY QUALIFIED ACCORDING TO �. 71!0 C 1021 <br />TO CONDUCT THE TESTING INDICATED. <br />1.7 DELIVERY, STORAGE, AND HANDLING <br />A. DELIVER, STORE, AND HANDLE IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. <br />I - /-% ) <br />p 813 241 5700 f 8 ; 247 3757 <br />#� e• . qr'`i..9, , ; 1.)•f ,.. 1,,J,.. ; ,,. <br />All Iepl.0urtior& inteliectuai property <br />rights resented 2017 <br />Project <br />,-"" , <br />. t <br />..,. aV i c, <br />D M%G 11= <br />zE P � � H i k 15 i...Ls <br />5935 7th Street Zephyrhills, <br />FL 33542 <br />Prepared for <br />in Association With: <br />HEES &ASSOCIATES iNC,. <br />CO ACT: t ARL HEES <br />13815TH ST <br />SARASOTA, `"'_ 34236 <br />PHONE: 941.955.4555 <br />GENESIS ENGINEER Gl LLC <br />CONTACT: MIKE HANEY <br />1000 N. ASHLEY DR. #900 <br />TAMPA, FL <br />H O i•d E: 813.523.6455 <br />GENESIS ENGiNF; lR GRO; P ' Ll' <br />CONTACT: MI tiANEY <br />1 0 ti fl Y DR � r!1 <br />00� .. HSh_E , �, .. 9u� <br />TAMPA, FL <br />PHONE: 813.523.6455 <br />- -p * _... <br />Pr "s'sbral Seal �; ',_I, <br />`7. <br />.:, <br />I. <br />1T <br />Y <br />. , <br />m , 8 <br />r:1 <br />h <br />tv I I aNbb s; � � <br />i <br />K <br />gzz-` <br />i rew J. Dohmen, AR 4 i 2/ 1012013 <br />15805 11:22:42 AM <br />No. Revision Description) Date <br />i PERMIT AND BID SET 12/10/2018 <br />`i0. Revision D 6SC' Y+ti " Date <br />Dram By: V VJ Checked By: SRS <br />Project Number: 18190 <br />Sheet Title <br />SPECIFIC; �5 I III Il <br />Original dravbnny is 24 x 36 Do not <br />scale contents of urav":ng <br />Sheet Numbe; <br />iI ,.: � ,­1, <br />I I <br />, , �, "-i __ I - <br />I , <br />Lm-q. mb.�. <br />