Laserfiche WebLink
II 1 1 1 1_1 '' " 111 1' 1 i _ ' I 1C'1 'tom 1 : I'! 1 II 1 _ 1 1 ' ' 1 i I, , i m-m", -mii I, , ,,n I ! qI I I I -. — I _ 1 1 1 _ _1 1 1 ' 1 71 ' 1111111 11PQ W, _. I _ _ I I _ <br />5 VERTICAL WALL REINFORCING <br />ACI 90 STANDARD GROUTED CELL <br />HOOK -EMBED 6" BOND BEAM W/(1) #5 REBAR <br />= z <br />= N FILLED CELL <br />O <br />O <br />> <br />w 5 DOWEL„ ACI STANDARD HOOK <br />w a APED 10 MIN LAP <br />�w Z 25 MIN W/ VERT. & HORIZ. REINFORCING <br />g <br />1n ; <br />N <br />� `�.',•. � � CONCRETE FOOTING <br />REINFORCING REBAR <br />• �: '' •= f= (SEE FOUNDATION PLAN) <br />25" MIN LAP <br />MASONRY WALL <br />FILLED CELL DETAIL <br />(1)#5 REROD IN GROUTED CELL <br />LOCATED PER PLAN <br />25" DOWEL LAP MINIMUM <br />4" CONCRETE (3000PS1) WITH #10 <br />6X6 MESH ON 6 MIL POLY <br />VAPOR BARRIER OVER CLEAN <br />COMPACTED POISON TREATED <br />SOIL. VAPOR BARRIOR <br />MATERIAL TO BE LAPPED <br />6' WITH SEAMS TAPED <br />FIBERMESH CAN BE SUBSTITUED <br />16"H X 12"W MONOLITHIC FOOTINGS WITH 2 EACH <br />BOTT50M OFR�OOTERCONTINUOUS <br />BE� 2'CHAIRS—TYPICAL <br />TYPICAL MO NO L YTHIC <br />FOOTING DETAIL <br />TERMITE PREVENTION NOTES: <br />COMPLY WITH FBC-2304.12 2019 6TH ED. BUILDING <br />1. A PERMANENT SIGN WITH IDENTIFIES TREATMENT PROVIDER <br />AND NEED FOR RE—INSP AND TREATMENT RENEWAL SHALL BE <br />PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER <br />ELECTRICAL PANEL FBC 104.26 <br />2. TO ENABLE TERMITE INSPECTION, THE DISTANCE, BETWEEN WALL <br />COVERING AND EARTH GRADE SHALL BE 6 INCHES MINIMUM. <br />EXCEPTION: CORRISION REISITANT METALS, CEMENTATIOUS FINISHES <br />APPLIED DIRECTLY TO FOUNDATION. <br />3. INITIAL TERMITE TREATMENT SHALL BE COMPLETED AFTER ALL <br />EXCAVATION AND BACK FILL IS FINISHED. <br />4. SOILD DISTURBED AFTER THE INITIAL TREATENT SHALL BE <br />RE —TREATED, INCLUDING SPACES BOXED OR FORMED. <br />5. BOXED AREAS IN CONCRETE FLOORS AND FOR SUBSEQUENT <br />INSTALLATION OF TRAPS, ETC, SHALL BE MADE IN PERMANENT <br />METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF A SIZE <br />& DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF SOIL <br />AFTER THE TREATMENT. <br />6. MINIMUM 6 MIL POLYFILM MUST BE INSTALLED TO PROTECT <br />AGAINST RAINFALL DILUTION. RETREATMENT IS REQUIRED IF <br />RAINFALL OCCURS BEFORE POLYFILM PLACEMENT. <br />7. CONCRETE OVERPOUR AND MORTOR ALONG THE FOUNDATION <br />PERIMETER MUST BE REMOVED BEFORE EXYERIOR SOIL TREATMENT. <br />8. ALL BUILDINGS ARE REQUIRED TO HAVE PRE —CONSTRUCTION <br />TREATMENT. <br />9. NO WOOD, VEGETATION STUMP, CARDBOARD, TRASH, ETC. SHALL <br />BE BURIED WITHIN 15 FEET OF ANY BUILDING OR PROPOSED <br />BUILDING. <br />10. AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST <br />BE REMOVED FROM WITHIN ONE FOOT OF THE BUILDING. THIS <br />INCLUDES <br />COGRADE <br />TAIN NGTMATE�IAB. TRAP BOXES, FORMS, OTHER <br />11. A CERTIFICATE OF COMPLIANCE MUST BE PROVIDED TO THE <br />BUILDING DEPARTMENT BY A LICENSED PEST CONTROL COMPANY <br />BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. THE <br />CERTIFICATE OF COMPLIANCE SHALL STATE THE BUILDING HAS <br />RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF <br />SUBTERRANEAN TERMITES AND THAT THE TREATMENT IS IN <br />ACCORDANCE WITH THE RULES AND LAW OF THE FLORIDA DEPT. <br />OF AGRICULTURE AND CONSUMER SERVICE. <br />2,_6,: <br />NOTE: <br />■ INDICATES 1— 5 REBAR IN FILLED CELL FROM <br />FOOTING TO L NTEL. LOCATED AT EACH SIDE <br />OF ALL WINDOWS AND DOOR OPENINGS <br />6' O.C. MAXIMUM SPACING. SEE DETAIL FOR LOCATIONS <br />FRONT VIEW <br />DOOR DETAIL <br />G.C. TO CONFIRM OPENING SIZE FOR DOGGIE <br />DOOR WITH OWNER <br />EDGE OF FOOTING <br />I I 1-#5 DOWEL IN CORNER <br />gm <br />25" LAP MIN <br />CORNER DETAIL — FOOTING AND <br />FOUNDATION WALL REINFORCEMENT <br />5 DOWEL HORIZ. REBAR <br />EAM REINFORCING <br />z <br />DOWEL -LAPPED WITH <br />Q I WALL REINFORCING <br />1 I <br />N : <br />VA <br />5 CORNER REBAR <br />OUTED CELL <br />NOTE: ALL LAPS SHALL BE 25" MINIMUM <br />CORNER DETAIL — BOND BEAM <br />AND WALL REINFORCEMENT <br />21'-4„ <br />'3, _ 8„ <br />�t- <br />3,-8„ <br />32"X32" 32"X32 <br />® r------— — — — — — — — — — — — — — — — — — — — — ---------� <br />4" CONCRETE (3000PSI) WITH #10 <br />I� 6X6 MESH ON 6 MIL P LY <br />VAPOR BARRIER OVER CLEAN I o0 <br />DATUM I - COMPACTED POISON TREATED I� I <br />-4" I I SOIL. VAPOR BARRIOR <br />a I DATUM M,QTERIAL TO BE LAPPED <br />I I <br />I <br />32"X32" <br />4" CONCRETE <br />SLAB <br />0 <br />0-0 6 WITH SEAMS TAPED <br />FIBERMESH CAN BE SUBSTITUED <br />4'— 0 EXPANSION JOIST o I „ <br />3" DRAIN 3" DRAIN I 32 X32 <br />I I I <br />I wN I I w� I I wcV I I w4 I <br />I Ivr I I I I <br />j OJ0 I 10 _j°D I I OO <br />00 I I j0 <br />j <br />V) \ I I =J cn \ I I cn \ I I cn <br />I I I I 4, I <br />L__ __J 1__ __ Ll 1 W_1 1 L - _-J <br />(4) 5ET DOOR <br />9.7"X17" <br />16"W X 12"H MONOLITHIC FOOTINGS WITH 2 EACH - <br />#5 (5/8") RODS CONTINUOUS ON CHAIRS —TYPICAL <br />vyELT0N 0 zz <br />No.53608 <br />aw <br />: -0 %• * OF <br />���0 6 .O IfoP <br />•���# •r• <br />/0 <br />hereby certify that I have reviewed this plan and found it to be in <br />compliance with ASCE 7-10 and the Florida Building Code 2017 6th Edition <br />David W. Smith, P.E. #53608 <br />12" W (X1)6"H MONOLITHIC FOOTINGS WITH 2 EACH <br />OTT5//0M „0 FFOOTERRODS NSHALL TINUOUS BE012"CFROM GRADEAL <br />F u"" UNDA TIO 1\1 TILAN <br />21'-4" <br />FRONT VIEW <br />DETAIL A - A <br />IIlAY1EI//�•i� <br />NOTE: IN LIEU OF BLOCK WALLS WITH SEPARATION <br />OF KENNELS, CHAIN LINK FENCING MAY BE <br />SUBSTITUTED. IF CHAIN LINK FENCE IS USED <br />THE FOOTERS FOR BLOCK WALLS MAY BE <br />REMOVED FROM FOUNDATION PLAN. <br />ENGINEER LICENCE 5# 3608 <br />CITY <br />FDEPARTMENTS RICK GOLLHARDT - DRAFTSIYIAN <br />6118 8TH STREET 813-781-3651 <br />Z E P HYR H I LLS FLORIDA rgollhardt@tampabay. rr. com <br />D.W.SMITH,M.S.,P.E.#53608 FOUNDATION SHEET OF <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 3 OF 6 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLASTON DRIVE—DADE CITY, FLORIDA 33525 SCALE DATE JOB NO. <br />PHONE: 813-469-2289 E-MAIL; dwsf Ipe@earthI, ink, net DO NOT SCALE 1 OCT 2019 <br />DESIGN/DRAWN CHECKED 2019 — 091 6 <br />R. GOLLHARDT D.W.S. <br />