My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6118 8th St (3)
Zephyrhills
>
Building Department
>
Building Plans
>
6118 8th St (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 9:50:00 AM
Creation date
2/18/2025 3:24:53 PM
Metadata
Fields
Template:
Building Plans
Street #
6118
Location
8th St
Contractor
D.W. Smith, MS, PE
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- - - ' I - —I I I -- - -- -- -- I 1 I I I f I ' ' 111' AIR 11 1 11.1 111,1111 ' 111111?1f71 1101'l11f 11 1 11 1 _ 1 1 <br />I I ' I !'"I Ir- I <br />DUCTLESS FAN COIL UNIT SCHEDULE <br />MARK <br />A/C # <br />FAN DATA <br />COIL DATA <br />FILTER DATA <br />BASIS OF <br />DESIGN <br />ELECTRIC <br />MCA <br />ELECTRICAL <br />MOCP <br />REMARKS <br />CFM <br />EXT. <br />SP "WG <br />MOTOR <br />HP <br />V/0 <br />EDB <br />'F <br />EWB <br />'F <br />TOTAL <br />CAP <br />MBH <br />SEN. <br />CAP. <br />MBH <br />TYPE <br />AREA <br />SQ <br />1 <br />425 <br />— <br />— <br />230/1 <br />80 <br />67 <br />18 <br />— <br />— <br />— <br />MITSUBISHI PKA—A18HA <br />1.0 <br />SEE CU <br />1 2 3 4 <br />10 PROVIDE DIGITAL THERMOSTAT FOR EACH UNIT Q PROVIDE LOW AMBIENT COOLING. Q3 POWER FEED FROM CONDENSING UNIT <br />®PROVIDE CONDENSATE PUMP ®CONDENSATE TO BE ROUTED TO EXTERIOR <br />DUCTLESS AIR COOLED CONDENSING <br />UNIT SCHEDULE <br />MARK <br />CU <br />LOC'N. <br />PAIRED WITH A/C-�f... <br />V/�D <br />ELECTRICAL DATA <br />BASIS OF DESIGN <br />REMARKS <br />MCA MOCP <br />1 <br />ROOF <br />1 <br />230/1 <br />28 <br />MITSUBISHI PUY-A18 <br />O O O3 <br />10 95 OUT DOOR AIR TEMP. (2) ROUTE REFRIGERANT LINE TO ROOF. <br />Q3 CONDENSING UNIT ON ROOF, LOCATION TO BE COORDINATED WITH BUILDING OWNER. <br />MECHANICAL EXHAUST REQUIRED AND THE RECIRCULATION OF AIR FROM SUCH SPACES <br />IS PROHIBITED. RECIRCULATION OF AIR THAT IS CONTAINED COMPLETELY WITH SUCH <br />SPACES SHALL NOT BE PROHIBITED (SEE SECTION 403.2.1, ITEM 3). <br />403.2.1 RECIRCULATION OF AIR <br />THE OUTDOOR AIR REQUIRED BY SECTION 403.3 SHALL NOT BE RECIRCULATED. AIR <br />IN EXCESS OF THAT REQUIRED BY SECTION 403.3 SHALL NOT BE PROHIBITED FROM <br />BEING RECIRCULATED AS A COMPONENT OF SUPPLY AIR TO BUILDING SPACES, EXCEPT THAT: <br />1. VENTILATION AIR SHALL NOT BE RECIRCULATED FROM ONE DWELLING TO ANOTHER OR <br />DISSIMILAR OCCUPANCIES. <br />2. SUPPLY AIR RO A SWIMMING POOL AND ASSOCIATED DECK AREA SHALL NOT BE RECIRCULATED <br />INLESS SUCH AIR IS DEHUMIDIFIED TO MAINTAIN THE RELATIVE HUMIDITY OF THE AREA AT <br />60 PERCENT OR LESS. AIR FROM THIS AREA SHALL NOT BE RECIRCULATED TO THERS SPACES <br />WHERE MORE THAN 10 PERCENT OF THE RESULTING SUPPLY AIRSTREAM CONSISTS OF AIR <br />RECIRCULATED FROM THESE SPACES. <br />3. WHERE MECHANICAL EXHAUST IS REQUIRED BY NOTE b INTABLE 403.3.1.1 RECIRCULATION OF <br />AIR FROM SUCH SPACES SHALL BE PROHIBITED. RECIRCULATION OF AIR THAT IS CONTAINED <br />COMPLETELY WITHIN SUCH SPACES SHALL NOT BE PROHIBITED. WHERE RECIRCULATION OF AIR <br />IS PROHIBITED, ALL AIR SUPPLIED TO SUCH SPACES SHALL BE EXHAUSTED, INCLUDING ANY <br />AIR IN EXCESS OF THAT REQUIRED BY TABLE 403.3.1.1. <br />4. WHERE MECHANICAL EXHAUST IS REQUIRED BY NOTE g IN TABLE 403.3.1.1, MECHANICAL <br />EXHAUST IS REQUIRED AND RECIRCULATION FROM SUCH SPACES IS PROHIBITED WHERE MORE <br />THAN 10 PERCENT OF THE RESULTING SUPPLY AIRSTREAM CONSISTS OF AIR RECIRCULATED FROM <br />THESE SPACES. RECIRCULATION OF AIR THAT IS CONTAINED COMPLETELY WITHIN SUCH SPACES <br />SHALL NOT BE PROHIBITED. <br />STANDING SEAM METAL ROOF TO MATCH EXISTING BUILDING. <br />METAL ROOF TO BE FASTEN AND INSTALLED PER MANUFACTURERS SPECS <br />SVEATHINQ TO BE 15/32" 4 PLY CDX OR OSB W./8d RING SHANK NAILS <br />6 O.C. 4 O.C. FOR FIRST 3 TRUSSES FROM GABLE ENDS <br />USE STEEL PLYCLIPS. RIDGE VENT AS REQUIRED PER FBC R806 --� <br />INSTALL ROOFING PER MANUFACTURERS SPECIFICATIONS <br />FLASHING PER FBC—R 905 <br />CONTINIOUS ALUM DRIP EDGE WITH GUTTER <br />AND DOWNSPOUTS ATTACHED PER <br />MANUFACTURERS SPECS <br />2X6 WOOD SUB ATTACHED TO <br />EACH 2) EApC WITH <br />8SppCOMMON <br />Tk,I MI CHED IPERNMANUF�I SPECS. <br />VARIES <br />SEE PLAN <br />yT�YPE"(M„##MORT��AggRqq P. RR� <br />FOOTER T05LINTELRBLOOCK <br />DECORATIVE CE ENTyOUS <br />FINISH STUCCO 1 2 2 COAT <br />PER SP CS FB —R 703 <br />4"X4" INSPECTION PORT <br />AT EACH FILLED CELL <br />TYPICAL <br />NOTE: EXTEND <br />DECO FINISH 4" TO 6" <br />BELOW GRADE <br />a Z <br />00 a <br />GRADE <br />z <br />CNM <br />12"W X 20"H MOOgNOLITHIC FOOTER <br />ON 3' 2&plt S TYPR CONT. <br />SPACED 4 O.C. MAX <br />R <br />O <br />000 <br />SYMBOL <br />DESCRIPTION <br />SWITCH <br />8GR <br />110 V RECEPTICLE - GROUND FAULT <br />WP, <br />WATERPROOF OUTLET <br />LIGHT FIXTURE - WALL OR CEILING (TYP) <br />C-./ <br />CEILING FAN ONLY <br />L� �J <br />a <br />ELECTRICAL PANEL <br />CEILING FAN: HAMPTON BAY, MODEL 52860, WHITE, 3 BLADE <br />OR EQUIVALENT. <br />E_.LECTRICALI/HVAC <br />R-30 BATT INSULATION (MIN) ATTIC SPACE <br />OPTIONAL BLOWN FIBERGLASS INSULATION <br />1 /2" CEILING TYPE GYPSUM BOARD <br />ATTACHED WITH 5d COOLER NAILS <br />OR #8 DUSE RYWW�ALL SCREW �AjTg 7 O.C. MAXp � q g <br />OTHYI�d�IX 1C/2 ANAILSTE ONPTROSELAYO&�FILL AELCNAILRHOLES <br />1 COURSE 8"X8" KNOCK —OUT BLOCK FILLED <br />LID W/(1) #5 BAR. TYP. AT ALL SOLID WALLS <br />PRECAST CONCRETE LINTEL <br />1X2 P.T. WD FURRING 0 24" O.C. <br />ATTACHED TO BLOCK WITH 3d <br />CUT NAILS 0 12 O.C. MAX <br />R5.4 CELOTEX "TUFF—R" INSULATION BD <br />OR EQUILIVANT <br />V2" GYPSUM WALLBOARD <br />N.O. <br />ATTACHED WITH 5d COOLER NAILS <br />1O��R44#8 DRYWALL SCREW AT 7 O.C. MAX <br />MUD' 3d <br />CUT NAILS ® 12 O.C. MAX <br />3 1/4" BASEBOARD <br />STANDARD 90 DEGREE BEND <br />WITH 25" LAP MINIMUM <br />F.F. <br />4" CONCRETE (3000PSI) WITH #10 <br />6-6/10-10 WWM ON 6 MIL POLY <br />VAPOR BARRIER OVER CLEAN <br />COMPACTED POISON TREATED <br />SOIL. VAPOR BARRIOR <br />MATERIAL TO BE LAPPED <br />6"WITH SEAMS TAPED <br />FIBERMESH MAY BE SUBSTITUTED <br />TYPICAL EXT_E'_'_'_RV.,I0R <br />EXISTING UTILITY <br />COMPANY PAD <br />EX CT TYPE METER MOUNTED <br />TRANSFORMER <br />120/208V, 30 <br />SECONDARY <br />METER <br />I <br />EXTERIOR I EX MAIN ELECTRICAL ROOM <br />EX <br />PMDPL <br />IX 15OA/3P <br />EX 1000A/3P <br />MAIN <br />PHASE _j <br />NEUT_GND—CONDUIT EX GROUNDING <br />ELECTRODE SYSTEM <br />MI IN, I <br />PARTIAL ONE -LINE DIAGRAM <br />NO SCALE <br />--------- EXISTING <br />--- — NEW <br />DETAIL SLOT FOR FOOD <br />FIELD COORDINATE ROUTING IN FIELD <br />WITH EXISTING CONDITIONS <br />LEXTERIOR I DOG KENNEL EXTERIOR <br />OPTIONS. <br />Mf_•STD. SIEMENS <br />C:C7PPERBUS SOLID NEUTRAL <br />CABINET SURFACE M,:,UN <br />T. N-1 <br />EXISTING <br />RATING 22000AIC RATED <br />PANEL NAME <br />A <br />SIZE' 250AML0, 250ABIJ5 <br />VOLTA <br />E.PHASE <br />200 3 PI 4W <br />r[D Dv <br />LOAD A <br />LL <br />A <br />_ <br />LGT COOL HEAT RCP MISC Web <br />Arrl s <br />_ <br />LOCATION <br />CKT <br />A B C CkT LOCATN74 <br />Arr s <br />_ <br />ides LIST COOL HEAT <br />RCPT MISC <br />1200 <br />2 <br />30 <br />EX SITE LI01 TING <br />1 <br />A# <br />1 2 <br />1EILIGHTING <br />20 <br />1 <br />1 1050 <br />04 <br />EX LIC?1 TING <br />20 <br />1 <br />1000 <br />1 <br />1200 <br />1200 <br />_ <br />30 <br />: >: SITE uGH TING <br />10 E <br />EX UGH TING <br />20 <br />1 <br />11 <br />_--- <br />7 <br />q# <br />3 <br />EX LC3IING <br />20 <br />1 <br />1060 <br />1200 <br />1200 <br />2 <br />30 <br />Er SITE LLA1 TING <br />9 <br />## <br />10 <br />EXLIGHTNG <br />20 <br />1 <br />1000 <br />11 <br />## 12 <br />EH LIGHTING <br />20 <br />1 <br />1000 <br />1200 <br />750 <br />1 <br />20 <br />E}; PHOTCICFLL <br />13 <br />IE# <br />14 <br />ENLIC41TING <br />20 <br />1 <br />1600 <br />1000 <br />1 <br />20 <br />EX UNDER EVE LIGHTS <br />15 <br />## <br />16 <br />EX LIGH TING <br />26 <br />1 <br />1000 <br />1000 <br />1 <br />20 <br />EX UNDER EVE LIGHTS <br />17 <br />Aat IB <br />EX LIGti LING <br />20 <br />1 <br />i000 <br />1000 <br />1 <br />2C <br />EX. UN I R EVE LIGHTS <br />19 <br />p# <br />20 <br />EX LIGh TINY <br />20 <br />1 <br />1000 <br />1000 <br />1 <br />2C <br />Ex UNDER EVE LIGHTS <br />21 <br />Y# <br />22 <br />El Li.Ail@IG <br />20 <br />1 <br />1000 <br />1000 <br />1 <br />20 <br />EX 61_LLARCS <br />23 <br />fiiL 24 <br />EXRECECFTAULES <br />20 <br />1 <br />108U <br />1000 <br />1 <br />20 <br />Er. UGHTNG <br />25 <br />#E <br />1 26 <br />IFX REC E C P TAC LE <br />20 <br />1 <br />1tIUl <br />1000 <br />1 <br />2C <br />EX FLAG LIC3HTS <br />27 <br />THE <br />28 <br />I EX R E C EC PTAC LE <br />20 <br />1 <br />1080 <br />SPACE <br />29 <br />## 30 <br />IEX REC'ECPTACIES <br />20 <br />1 <br />1 <br />_ <br />11180 <br />SPACE <br />31 <br />0 <br />32 <br />SPACE <br />SPACE <br />33 <br />0 <br />34 <br />SPACE <br />_ <br />_ <br />SPACE <br />75 <br />*0 36 <br />_ <br />NEWPNL'DK' <br />40 <br />2 <br />500 <br />1144 <br />0 <br />360 <br />O <br />SPACE <br />37 <br />## <br />38 <br />0 <br />1144 <br />O <br />O <br />Boo <br />SPAT=E <br />39 <br />C <br />40 <br />SPATE <br />SPACE <br />41 <br />0 42 <br />SPACE <br />_CII ECTE <br />LOAD <br />SUMWRI <br />A <br />DEMAND <br />YEI <br />SUMMARI' <br />P I.SE A a <br />C TOTALS <br />COMMENTS <br />UDAD <br />L37 8400 9400 <br />7900 <br />25700 <br />1.25 <br />32.1H VA <br />COOL 1144 0 <br />1144 <br />2288 <br />1,00 USE COOL LOAD FOR CALCULATION <br />2,288 VA <br />HEAT 0 0 <br />0 <br />0 <br />0 VA <br />PFCPT 1080 1080 <br />2s20 <br />4660 <br />1 00 <br />4 HD •:A <br />M6C 750 0 <br />C1 <br />750 <br />1 00 <br />750 VA <br />tPCi MTR Ll 0 <br />0 <br />0 <br />025 <br />0'+A <br />TO7AL CONNECTED LOAD PER PHASE <br />TOTAL DEMAND LOAD <br />39,843 1( <br />F HASEA 11.3i4 VA <br />94.8 <br />AIAP:' <br />TOTALDEMA14D CLJPRE14T <br />1106 AT.P5 <br />F HASE8 10'80 VA <br />87.3 <br />AMPS <br />PHASE C 11,564 VA <br />96A <br />AMPS <br />MNMUM S'ERVNCEAMPS REQUIRED <br />1106 Am[6 <br />UV�i.LL SECTIO-il <br />�,,,_, ` ` <br />P_ \ \ <br />� ` \ \ <br />r-1 � \ \ \ <br />LJ <br />011 <br />INTERIOR GATE dc FENCE <br />GATE AND FENCE PROVIDED <br />BY OTHERS <br />i <br />IxAW LOCATE ANp HOSE BIB <br />CONNECT TO EXISTING <br />3/4" i i HOSE BIB <br />i <br />i I <br />3/413 VALVES 11.4 <br />i J <br />NOTE: SEE OWNER FOR HEIGHT <br />! OF HOSE BIBS ` y' <br />i I HOSE BIB 3/4" <br />I <br />PHASE <br />EUT_GND_CONDUIT I i <br />I � <br />i <br />WATER ISOMETRIC <br />OPTIONS: <br />MFG STD <br />SUUAREZ UG <br />COPPER BUS <br />CABINET <br />SURFACE MOUNT N-3ti'. <br />NEW <br />RATING <br />22,000AIC SERIES RATED <br />PANEL NAME. <br />DK <br />SZE <br />100AMLD <br />VOLTAGE/PHASE <br />2D8 I PH 3VV <br />LOAD VA <br />LOAD VA <br />LOT <br />I COOL <br />HEAT <br />PC -PT <br />I MISC <br />I EcIes <br />Amps <br />LOCATION <br />I CI<T <br />A I <br />E; C17 <br />LOCATION <br />Amps <br />poles <br />I Lr_,T <br />I COOL <br />HEAT <br />RCPT <br />I MISC <br />1i44 <br />2 <br />20 <br />G'U/AC <br />1 <br />z# <br />2 <br />LL3HTS <br />20 <br />1 <br />500 <br />_ <br />3 <br />sl!• 4 <br />FANd- <br />2C <br />1 <br />5i10 <br />1144 <br />_ <br />I RECEP <br />2U 1 <br />360 <br />L'CNNECTF-DI OAD SI Ind MARY VA <br />DFMAND LOAF) SLI MMARY <br />PHAASE <br />A <br />B TOTALS <br />D.F. COMMENTS <br />LOAD <br />I_G'T <br />500 <br />0 500 <br />1 25 <br />625 VA <br />COOL <br />1144 <br />114-4 2288 <br />1 01) USE COOL LOAD FOR CALCULATION <br />2,288 VA <br />HEAT <br />CI <br />D D <br />D VA <br />RECPT <br />360 <br />0 36G <br />1 00 <br />366 VA <br />ML4C <br />0 <br />500 500 <br />100 <br />5W 'VA <br />TOTAL CONNECTED <br />LOAD PER PHASE <br />TC-TAL DEMAND LOAD 3,773 VA <br />PHASE A <br />2,004 VA <br />16 7 ,AMPS <br />TOTAL DEMAND CURRENT <br />131 Arnps <br />PHASE B <br />1,W VA <br />13.7 AMPS <br />MINIMUM SERVC-E.AMPS REQUIRED 227 Amps <br />LOAD SUMMARY <br />LOAD DESCRIPTION EXISTING <br />LOAD ADDED <br />kVA <br />EXISTM LOAD FROM UTILITY X125%n 14250 <br />142.50 <br />LIGHTING 1.25 demand Factor applied) <br />0.63 <br />0.63 <br />HVAC Meat load used for calcUatimL_ <br />2.29 <br />229 <br />RECEPTACLE demand factor bed <br />0.36 <br />0.36 <br />MISC. <br />0.50 <br />0.50 <br />TOTAL = <br />14627 WA <br />jamperes at 208 V 3 PHASE <br />406.01 amps <br />I <br />1 <br />2" VTR <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />WASH TUB <br />3 DRAIN <br />--' TRENCH DRAIN <br />- <br />3" DRAIN <br />PLUMBING ISOMETRIC <br />DRAIN INFO <br />ZURN Z415C STRAINER <br />3" IP THREAD OUTLET <br />ZURN OR EQUILIVANT <br />3" P-TRAP BETWEEN TROUGH <br />AND CLEAN OUT <br />CONNECT TO EXISTING <br />MEMMOMEM <br />SEWER CONNECTION <br />TO EXISTING <br />TRENCH DRAIN INFO <br />NDS - DURA SLOPE TRENCH DRAIN <br />(PRE -SLOPED) <br />PART# DS-97 6.01 "X6.35" DEEP X 4' <br />DURA SLOPE CHANNEL <br />STANDARD GRATES <br />DS-221 2 FT GALV. STEEL CHANNEL GRATE <br />UNIVERSAL END CAP <br />DS-224 <br />UNIVERSAL END OUTLET <br />DS-227 FITS 4" S&D PIPE <br />NDS OR EQUILIVANT <br />" VTR <br />N *HB <br />WA�TU <br />I » <br />3" DRAIN 3"LRAIN <br />13 <br />—4' ' — 4" <br />4' <br />------- —-------- —-------- — --------. <br />rn <br />--d11 <br />-�d11 <br />1 <br />3" <br />1 <br />® ® FLDw <br />---------------------------------------------------------------- <br />DRAIN DRAIN DRAIN DRAIN <br />hereby certify that I have reviewed this plan and found it to be in <br />compliance with ASCE 7-10 and the Florida Building Code 2017 6th Edition <br />David W. Smith, P.E. #53608 <br />
The URL can be used to link to this page
Your browser does not support the video tag.