GENERAL NOTES:
<br />THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2011 FLORIDA BUILDING CODE
<br />6TH EDITION AND THE 2011 FLORIDA BUILDING CODE - RESIDENTIAL 6TH EDITION.
<br />T,L. HANSON A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL ENGINEERING
<br />COMPANY: HAS APPLIED "RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN OF THIS STRUCTURE.
<br />THE BUILDING (INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE
<br />FOLLOWING SUPERIMPOSED LOADS:
<br />SLAB:
<br />LIVE LOAD - 50 P.S.F.
<br />DEAD LOAD - 10 P.S.F.
<br />ROOF:
<br />LIVE LOAD (TRUSS TOP CHORD) - 20 P.S.F,
<br />DEAD LOAD (TRUSS TOP CHORD) - 10 P.S.F. (15 P.S.F. WHEN TILE ROOFING IS INSTALLED)
<br />DEAD LOAD (TRUSS BOTTOM CHORD) - 10 P.S.F.
<br />ASSUMED TRUSS SELF WEIGHT (DEAD LOAD) - 1 P.S.F.
<br />WIND:
<br />BUILDING IS DESIGNED TO CONFORM TO ASCE 1-10, CHAPTERS 26 THRU 31: PER 2011 FLORIDA
<br />BUILDING CODE, RESIDENTIAL 6TH EDITION- SECTION R301.2.1.1. AND 2011 FLORIDA BUILDING CODE
<br />6TH EDITION SECTION 1609
<br />WIND DESIGN ASSUMPTIONS:
<br />BUILDING EXPOSURE - B
<br />BUILDING RISK CATEGORY - II
<br />MEAN ROOF HEIGHT 30' OR LESS
<br />HEIGHT 4 EXPOSURE ADJUSTMENT
<br />COEFFICIENT ° 1.0
<br />ENCLOSED BUILDING
<br />INTERNAL PRESSURE COEFFICIENT ° +/- 0,18
<br />WIND SPEED SHOWN AT THE BOTTOM RIGHT
<br />CORNER OF THIS SHEET
<br />ALL STRUCTURAL ELEMENTS, EXTERIOR
<br />WALLS AND INTERIOR WALLS SHALL BE
<br />TYPE V CONSTRUCTION PER FBC 602.5
<br />COMPONENT 4 CLADDING WIND LOADS
<br />ALL OTHER
<br />BUILDING
<br />ROOF OVERHANG
<br />COMPONENT
<br />ZONE
<br />LOADS
<br />LOADS
<br />1
<br />N/A
<br />+32.3/-35.3
<br />2
<br />-65.1
<br />+32.3/-56.2
<br />3
<br />-110.6
<br />+32.3/-89.0
<br />4
<br />N/A
<br />+35.3/-38.2
<br />5
<br />N/A
<br />+35.3/-41.2
<br />SOIL BEARING 4 COMPACTION:
<br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 P.S.F.
<br />,MINIMUM). THE CONTRACTOR/PROPERTY OWNER ARE RESPONSIBLE FOR VERIFYING THAT THE SO L
<br />ON THE SITE IS PROPERLY PREPARED 4 COMPACTED SUCH THAT IT CAN SUPPORT A 2,000 P.S.F.
<br />FOUNDATION LOADING,
<br />T.L. HANSON: A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL
<br />ENGINEERING COMPANY: DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION SITE
<br />NOR PERFORMING ANY SOIL TESTING.
<br />T.L. HANSON SHALL NOT BE RESPONISIBLE FOR THE SITE SOILS ABILITY TO SUPPORT
<br />THE BUILDING LOADS.
<br />FOUNDATIONS 4 SLAB -ON -GRADE:
<br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS WITHIN THE BUILDING AREA.
<br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED
<br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2,000 P.S.F. FOUNDATION LOADING.
<br />SLAB SHALL BE PLACED OVER A 6 MIL VAPOR BARRIER ON CLEAN, ADEQUATELY
<br />COMPACTED AND TERMITE POISONED SOIL.
<br />CONCRETE UTILIZED IN THE FOUNDATIONS AND SLABS SHALL HAVE A MINIMUM 28 DAY
<br />COMPRESSIVE STRENGTH OF 2,500 P.S,I•
<br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE
<br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25"
<br />FOR "5 REBAR, 30" FOR "6 REBAR 4 35" FOR "1 REBAR.
<br />PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES (AFTER
<br />FINAL SITE GRADING). THE CONTRACTOR O? BUILDING OWNER SHALL DETERMINE THE
<br />EXACT STEMWALL HEIGHT BASED UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION
<br />AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSES ARE REQUIRED.
<br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE
<br />SITE FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND
<br />A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY THE REQUIRED BUILDING SETBACKS.
<br />MASONRY WALLS:
<br />CONCRETE MASONRY UNITS SHALL BE HOLLOW UNIT MASONRY IN ACCORDANCE WITH ASTM C-90
<br />AND SHALL NAVE A MINIMUM F'M OF 1,500 P.S.I.
<br />MORTAR SHALL CONFORM TO ASTM C-210 AND SHALL BE EITHER TYPE M OR S.
<br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE
<br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25"
<br />FOR "5 REBAR, 30" FOR "6 REBAR 4 35" FOR 01 REBAR.
<br />GROUT FOR THE POURED CELLS AND LINTELS SHALL HAVE A MAXIMUM COURSE AGGREGATE SIZE
<br />OF 3/8", PLACED AT AN 8 TO 11 INCH SLUMP AND HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH
<br />OF 2,500 P.S.I, (WHEN TESTED PER ASTM C-1019).
<br />PROVIDE CLEAN -OUT OPENINGS (12 SQ. IN.) IN CELLS CONTAINING SPLICED REINFORCEMENT, WHEN
<br />THE GROUT POUR EXCEEDS 5 FEET IN HEIGHT.
<br />TIMBER MATERIALS:
<br />ALL TIMBER MATERIALS SHALL BE AS FOLLOWS:
<br />IF DESIRED, EQUIVALENT CONNECTORS MADE BY ANOTHER SUPPLIER MAY BE USED IN PLACE OF THE
<br />"USP" OR "SIMPSON" CONNECTORS SHOWN,
<br />ALL LUMBER IN CONTACT WITH MASONRY WILL BE PRESSURE TREATED
<br />MATERIALS
<br />ATTIC ACCESS:
<br />ATTIC ACCESS SHALL BE PROVIDED TO ATTIC AREAS EXCEEDING 30 80, FT, AND HAVING MINIMUM
<br />30 INCHES OF VERTICAL HEIGHT. ROUGH -FRAMED OPENING NOT TO BE LESS THAN 22 X 30 INCHES,
<br />WHEN MECHANICAL EQUIPMENT IS LOCATED IN THE ATTIC, IT SHALL BE INSTALLED IN ACCORDANCE
<br />WITH THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION M1305.1.3
<br />ATTACH MINIMUM 3/4" P.T. BUCK
<br />STRIP THAT IS THE MINIMUM WIDTH
<br />OF DOOR FRAME I:SiNG .091X1 3/8"
<br />T- NAILS MAXIMUM 10" OC.
<br />CAULK DOOR FRAME PER YOUR
<br />MANUFACTURES RECOMMENDATIONS
<br />SECURING PREHUNG TO BUCK STRIPS
<br />PER YOUR MANUFACTURES INSTRUCTIONS
<br />TO MEET WIND LOADS AND COMPRESSIONS
<br />RATINGS FOR YOUR JOB LOCATION, ALL
<br />ANCHOR SCREWS MUST PENETRATE BLOCK
<br />WALL A MINIMUM OF 1 1/4" AND THERE SHALL
<br />BE A MAXIMUM I/4" SPACE BETWEEN BUCK
<br />AND DOOR JAMB
<br />BLOCK DOOR ATTACHMENT DETAIL
<br />NOT TO SCALE
<br />THE CLIENT UNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE
<br />AGREES TO HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOSSES AND
<br />EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING+ OUT OF OR RESULTING FROM THE
<br />PROJECT. THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION
<br />DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR COST OF
<br />REPAIRS OR DELAY TO THE CONSTRUCTION
<br />SOIL TERMITE TREATMENT:
<br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES
<br />APPLIED TO SOIL, OR WOOD, BAITING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR
<br />USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION.
<br />A "CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED
<br />PEST CONTROL COMPANY BEFORE A "CERTIFICATE OF OCCUPANCY" WILL BE ISSUED. THE CERTIFICATE
<br />SHALL STATE
<br />"THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN
<br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA
<br />DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES,"
<br />IF A REGISTERED TERMITICIDE BAIT SYSTEM IS TO BE USED FOR SUBTERRANEAN TERMITE PREVENTION,
<br />DO NOT APPLY, A SIGNED FIVE YEAR CONTRACT FROM THE ISSUE
<br />OF THE CERTIFICATE OF OCCUPANCY ASSURING INSTALLATION, MAINTENANCE AND MONITORING OF THE
<br />BAITING SYSTEM SHALL BE PROVIDED TO THE BUILDING OFFICIAL PRIOR TO THE SLAB POUR. THE SYSTEM
<br />MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL.
<br />INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION,
<br />BACKFILLING 4 COMPACTION ARE COMPLETE
<br />ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED
<br />(INCLUDING ANY BOXED OR FORMED AREAS) -
<br />BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE
<br />WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF AN
<br />ADEQUATE SIZE 4 DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE
<br />INITIAL TREATMENT.
<br />A MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL
<br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT
<br />SHALL BE REQUIRED
<br />ANY CONCRETE OVERPOUR, MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER
<br />MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT
<br />EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE
<br />WITHIN 12 INCHES OF THE STRUCTURE SIDE WALLS
<br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS
<br />COMPLETE (INCLUDING LANDSCAPING AND IRRIGATION). ANY SOILS DISTURBED AFTER THE
<br />VERTICAL BARRIER IS APPLIED, SHALL BE RE -TREATED.
<br />CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12 INCHES AWAY FROM THE
<br />BUILDING SIDEWALLS (PER FBC R318).
<br />AFTER ALL WORK IS COMPLETED, ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW
<br />AND WITHIN 12 INCHES OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES, TUB TRAP BOXES
<br />FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS.
<br />THE DISTANCE FROM THE EXTERIOR WALL COVERING (EXCEPTIONS: PAINT AND DECORATIVE
<br />CEMENTITIOUS FINISHES LESS THAN 5/8 INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION
<br />WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES TO ALLOW FOR INSPECTION
<br />FOR FUTURE TERMITE INFESTATIONS
<br />TRUSSES:
<br />IF THE CONTRACTOR, TRUSS MANUFACTURER OR ANY OTHER DESIGN PROFESSIONALS REVISE THE
<br />TRUSS SYSTEM LAYOUT FROM THOSE SHOWN ON THESE PLANS T. L. HANSON 4 ASSOCIATES IS
<br />REQUIRED TO REVIEW ALL FINAL CONSTRUCTION DOCUMENTS FOR COMPLIANCE WITH THE DESIGN
<br />INTENT PRIOR TO COMMENCEMENT OF THE PROJECT.
<br />EXTERIOR WINDOWS 4 DOOR ASSEMBLIES:
<br />ALL EXTERIOR WINDOW 4 GLASS DOORS SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA
<br />101/162 STANDARDS AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER,
<br />PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY.
<br />ALL MULLIONS AND ADJACENT DOOR/WINDOW ASSEMBLIES SHALL BE TESTED OR ENGINEERED TO
<br />TRANSFER 1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE.
<br />INSTALL ALL WINDOW 4 DOOR ASSEMBLIES PER THE MANUFACTURERS ANCHORING RECOMMENDATIONS
<br />TO ACHEIVE THE DESIGN PRESSURES SPECIFIED.
<br />ELECTRICAL, PLUMBING 4 MECHANICAL:
<br />IN ACCORDANCE WITH CHAPTER 411.003(2XI) OF THE FLORIDA ADMINISTRATIVE CODE: ELECTRICAL,
<br />PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTORS TO
<br />MEET ALL APPLICABLE CODES. THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HEREON
<br />ARE BASED UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS.
<br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN (WITHIN 6 FEET OF SINKS), GARAGE AND AT
<br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND -FAULT INTERRUPTER "GPI" CIRCUIT.
<br />ALL ELECTRICAL OUTLETS IN BEDROOMS SHALL BE WIRED INTO AN ARC -FAULT INTERRUPTER
<br />"AFI" CIRCUIT.
<br />SAFETY GLAZING:
<br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF
<br />GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308:
<br />(1) GLAZING IN SWINGING DOORS, FIXED AND SLIDING PANELS OF SLIDING DOOR
<br />ASSEMBLIES.
<br />(2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM
<br />ROOMS, BATHTUBS, AND SHOWERS, GLAZING IN ANY PORTION OF A BUILDING WALL
<br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS
<br />THAN 60 INCHES ABOVE THE DRAIN INLET.
<br />(3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE
<br />THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR IN A
<br />CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE
<br />FINISHED FLOOR OR WALKING SURFACE.
<br />(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS
<br />DESCRIBED IN ITEMS (2) AND (3) ABOVE. THAT MEETS ALL OF THE FOLLOWING
<br />CONDITIONS:
<br />A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SO. FT.
<br />B) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR.
<br />C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR.
<br />D) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE
<br />PLANE OF THE GLAZING.
<br />REFER TO THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308 FOR ADDITIONAL AREAS
<br />THAT MAY BE CONSIDERED A HAZARDOUS LOCATION FOR THE PURPOSE OF GLAZING.
<br />GARAGE DOOR TO BE REINFORCED
<br />TO MEET WIND LOAD AND COMPRESSION
<br />RATINGS FOR YOUR JOB LOCATION, CEILING RAFTER
<br />ALL TRACK AND HARDWARE SECURED
<br />PER MANUFACTURE SPECIFICATIONS TO
<br />MEET WIND LOAD AND COMPRESSION
<br />RATINGS FOR YOUR JOB LOCATION
<br />MINIMUM 2X6 P.T. SIDE PLATE ATTACHED
<br />TO BLOCK WALL USING I/2"X8" ANCHOR
<br />BOLTS OR 5/8"Xl" EXPANSION BOLTS
<br />4 EACH SIDE. ATTACH TOP 2X6 WITH
<br />2 3/8" T NAILS I6" OC
<br />GARAGE DOOR ATTACHMENT DETAIL
<br />NOT TO SCALE
<br />°5 VERTICAL RODS FROM FOOTINGS
<br />BELOW TO TOP OF WALL. PLACED AT
<br />ALL CORNERS, EACH SIDE OF ALL
<br />OPENINGS AND SPACED MAXIMUM
<br />6' O" CC.
<br />LINTELS ON THIS PROJECT ARE AS SPECIFIED ON THIS
<br />CHART UNLESS NOTED ON FLOOR PLAN BY OPENING
<br />LINTEL LOAD CHART ( 16" DEEP SECTION )
<br />CLEAR SPAN
<br />CONCRETE U LINTEL
<br />1' - 6"
<br />4981 PLF ( UNFILLED )
<br />2' - 211
<br />3435 PLF ( UNFILLED )
<br />2' - 811
<br />2Tn PLF ( UNFILLED )
<br />3' - 211
<br />2332 PLF ( UNFILLED )
<br />4' - O"
<br />1835 PLF ( UNFILLED )
<br />4' - 611
<br />1624 PLF ( UNFILLED )
<br />5'-211
<br />2139PLF«
<br />6'-211
<br />2211PLF«
<br />it -oil
<br />1981PLF«
<br />8' -oil
<br />1123 PLF ••
<br />9' - 211
<br />1499 PLF ••
<br />10' - 011
<br />1354 PLF «
<br />10' - 8"
<br />12-M PLF «
<br />II' - 2"
<br />1200 PLF «
<br />12'-0"
<br />1109PLF«
<br />12' - 811
<br />1044 PLF «
<br />13' - 4"
<br />1398 PLF « P
<br />14' - 0"
<br />1321 PLF « P
<br />16'-oil
<br />1152PLF«P
<br />1016PLF ••P
<br />9T1 ,'! F « P
<br />20' - O"
<br />816 PLF •• P
<br />22' - 8'1
<br />189 PLF •• P
<br />« - DENOTES 05 REBAR X CONT, PLACED IN BOTTOM COURSE AND
<br />16" DEEP BEAM POURED SOLID WITH 2500 PSI CONCRETE.
<br />« P - DENOTES PRE STRESSED U LINTEL WI114 "5 REBAR X CONT.
<br />PLACED IN BOTTOM COURSE 4 I6" DEEP BEAM POURED SOLID
<br />WITH 2500 PSI CONCRETE
<br />8" X 8" X 16" KNOCK OUT BLOCK
<br />TOP COARSE WITH 105 HORIZONTAL
<br />all REBAR TIED TO ALL VERTICAL RODS
<br />.�• 8" PRECAST LINTEL BLOCK
<br />OVER ALL OPENINGS. I EACH
<br />REBAR IN THIS COARSE WHEN
<br />SPAN OF LINTEL OVER 511
<br />STANDARD PRECAST DETAIL
<br />21' 411
<br />FOUNDATION FLAN 1/4 OII
<br />DRILL 1" X 6" HOLE INTO EXISTING BOND BEAM
<br />AND EPDXY 05 REBAR FROM NEW BOND BE,
<br />INTO EXISTING BOND BEAM,
<br />DRILL 1"Xrc" HOLE INTO EXISTING WALLS 24"
<br />AND EPDXY 05 REBAR FROM NEW BLOCK
<br />INTO EXISTING BLOCK WALL, REBAR TO BE
<br />LONG WITH 611 INTO EXISTING WALL 6" IN NEI
<br />BLOCK WALL
<br />DRILL 1" X 6" HOLE INTO EXISTING FOOTING
<br />AND EPDXY 05 REBAR FROM NEW FOOTINGS
<br />INTO EXISTING FOOTINGS
<br />6' 411
<br />NEW BLOCK WALL TO EXISTING WALL DETAIL
<br />NOT TO SCALE
<br />1JEEN
<br />•i 09" evc a„yi
<br />61
<br />q s'
<br />t._� .
<br />c
<br />'r J J
<br />e
<br />it
<br />erg, e°j-Ie
<br />s. . ANSON P.E. LICENSS; NO. 38654
<br />xg•eVOXSVXM CITIj j� 3�26
<br />1 HERBY CE4�0bf%4Kvp;f'r,,SPECIFICATIONS
<br />WERE PREPARKIP"' a ME-Rxd�yfQ��LY DIRECT SUPERVISION
<br />ARE IN COMPLI,4 p @f ,,V'. Ai'fi�E1_%16, SECTION 1609 OF THE
<br />FLORIDA BUILDING �b� �{� b��iI. ADDITION AND ASCE 1-10
<br />FOR 139 MPH WIND ZONE RISK CATEGORY II AND 'THE ENTIRE
<br />2011 BUILDING CODE RESIDENTIAL 6TH ADDITION
<br />0
<br />■
<br />cM
<br />:J
<br />U-)
<br />co
<br />y�
<br />Z
<br />co
<br />o
<br />o�
<br />m
<br />J CV
<br />LL r--
<br />z
<br />cV
<br />C7
<br />U U')
<br />V]
<br />0Q
<br />UJ —
<br />W
<br />0
<br />A
<br />?a�.N
<br />m LO
<br />� 1
<br />m 0) m
<br />LU
<br />W
<br />2 U
<br />.L
<br />O
<br />N
<br />M
<br />—
<br />0
<br />c()
<br />Q
<br />tL1
<br />c
<br />O
<br />ro
<br />X M
<br />z
<br />zN
<br />m� a
<br />O
<br />!lJ w
<br />z
<br />� L O
<br />z
<br />Z
<br />ZZ
<br />ca
<br />?
<br />U
<br />W
<br />�z
<br />(L 0
<br />J
<br />o
<br />�
<br />O
<br />W
<br />O
<br />N
<br />73
<br />w Z
<br />O
<br />UW
<br />tt
<br />6�
<br />I
<br />6
<br />zz
<br />ca
<br />Q
<br />IL
<br />Q
<br />ul
<br />q
<br />z
<br />Ocl
<br />T
<br />cq
<br />—1
<br />2
<br />0 -
<br />ul
<br />d
<br />m
<br />N
<br />V
<br />n
<br />Ln
<br />m
<br />GARAGE
<br />ADDITION
<br />426. ro SQ, FT.
<br />2 OF 3
<br />
|