Laserfiche WebLink
1x4 1/2" DRYWALL DOOR JAMB (REFER 1x4 �1/2" DRYWALL DOOR JAMB (REFER 1x4 1/2" DRYWALL <br />DOOR JAMB (REFER P.T. TO PRODUCT _jTO PRODUCT <br />TO PRODUCT APPROVAL FOR CONN: APPROVAL FOR CONN. �' / 1 X 4 <br />1x4 P.T.APPROVAL FOR CONN. ! /� /! , /%/ 1x4 <br />J FURRING 3/16" � X 3" LONG /!X FURRING (2) ROWS 3/16" x 3-1/2" %/ FURRING <br />3-1/4 LONG X 3/16' TAPCONS TAPCON 16" Q.C. & 4" 2X8 <br />TAPCON. INTO STAGGERED @ 16" 1x8 P.T. FROM EACH END w/ MIN. 1X8 <br />BLOCK@ SPACING „ O.C. 2-ROWS INTO 2" EDGE DIST. ATTACH <br />PER MANUFACTURE 1 DETAIL MASONRY THROUGH rr <br />1x4 P.T. & 1x8 P.T. 1-1/2 DETAIL 1x8 w/ (2) ROWS 8d NALS 3" DETAIL <br />STAGGERED @ 12" O.C. <br />3/16" x 3 -1/2" DOOR JAMB (REFER <br />TAPCON @ 16" 1x4 P.T. <br />O.C. & 4" FROM DOOR JAMB (REFER TO PRODUCT <br />EACH END W/ MIN. TO PRODUGT APPROVAL FOR CONN. 1x4 1/2" DRYWALL <br />DOOR JAMB (REFER APPROVAL FOR CONN. ; %%- 2x8 P.T. w/ 2 ROWS 3/16" <br />2" EDGE DIST. % ( ) <br />TO PRODUCT x 3-1/2" TAPCON @ 16" <br />APPROVAL FOR CONN. ',/. ; j (2) ROWS 3/16" x 3-1/21 ' . /�� ' O.C. & 4" FROM EACH 1x4 <br />TAPCON @ 16" O.C. & END w/ MIN. 2" EDGE DIST. FURRIN! <br />4" FROM EACH END wl 2x8 P.T. ATTACH SECOND PLY w/ <br />2x P.T. AS REQ'D MIN. 2" EDGE DIST. (2) ROWS 10dx3" 2x8 <br />2x DETAIL 2 1/4" DETAIL STAGGERED @ 12" O.C. ri-i /Aiv nFTA11 <br />BUILDOUT (a� OVER SIZE DOOR -WINDOW ROUGH OPENINGS <br />SCALE: N.T.S. <br />2x8 P.T. BUCK -CONNECT TO BLOCK <br />W/ 1/4" x 3 1/4" TAPCON (1 1/4" MIN. <br />EMBEDMENT INTO BLK.) <br />1 X 4 FURRING <br />BLOCK HEADER <br />1/2" DRYWALL <br />8d NAILS AT 8" O.C. AT BUCK <br />2 x 8 45^ DIAGONAL (4) 10d NAILS INTO <br />BRACE(S) 2 x 8 BRACE/ BLKG. <br />7/16" OSB <br />BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />SCRIBE (NOTCH) POLY -CELL IN THIS AREA <br />rT� <br />BACKSIDE TO FIT ARCH (4) 10d NAILS INTO 2 x 8 <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />ARCH FACES W (4)10d NAILS THRU OSB INTO 2 x 8 <br />A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU —� <br />1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH <br />ARCH DETAIL <br />SCALE: N.T.S. SS <br />INSTALL WDW. SCREW ANCHOR <br />INTO ARCH BLKG. PER <br />INSTALLATION DETAILS <br />BLOCK HEADER <br />1 X 4 FURRING <br />8d NAILS @ 8" O.C. AT BUCK <br />PROVIDE 2 x 8 DIAG. BRACE BT <br />VERT. BRACES WHEN HGT. OF <br />BRACE EXCEEDS 24" <br />2 x 8 VERT. BRACE(S) <br />BUILT UP PLWD. BUCK - — <br />SCRIBE (NOTCH) BACKSIDE <br />TO FIT ARCH CONNECT W/ <br />8d NAILS <br />INSTALL WDW, SCREW---- <br />ANCHOR INTO ARCH BLKG. <br />PER INSTALLATION DETAILS <br />1/4" MAX <br />fi SOLID BLKG. AT TOP BTWN. <br />ARCH BLKG. & BUCK <br />2'-0" <br />2 x 8 BUCK - CONNECT TO BLOCK <br />WITH 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />�1/4" MAX EMBEDMENT INTO <br />it SOLID BLKG. AT TOP BTWN. ARCH <br />BLKG. & BUCK <br />2 x 8 VERT. W/ (2)1 Od <br />NAILS AT EA. END <br />LEAVE A CUT OUT IN O.S.B. ON TI <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />7/16" OSB ARCH PANEL <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />BTWN. OSB ARCH FACES W/ (4)10d NAILS EQUAL <br />THRU OSB INTO 2 x 8 <br />------------ <br />B_B ARCH DETAIL K <br />SCALE: N.T,S. SS <br />2'-0" <br />SECTION <br />A -A <br />8" <br />1/4" x 31/4" TAPCONS <br />CLEAVE A CUT OUT IN O.S.B. ON THE <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />—2 x 8 45 DIAGONAL BRACE AT EA. <br />FACE OF ARCH W/ (3)10d NAILS <br />- AT EA. END <br />PROVIDE TAPCON WITHIN <br />4" MIN. OF BRACE <br />START OF ARC <br />4' MAX. RAD. <br />SECTION <br />B-B <br />8" <br />PROVIDE 2x <br />PROVIDE (2) MIN. CONT. W/ (3) <br />TAPCON AT EA. SIDE 12d NAILS <br />BUCK - (1) WITHIN 4" <br />MIN. OF START OF <br />ARCH <br />START OF ARC <br />EQUAL 4' MAX. RAD. <br />PROPER INSTALLATION MAx.B <br />#5 REB, <br />(TYP,) <br />FILL SOLID <br />STD. 90' <br />HOOK (. <br />BOTH CELLS <br />771 <br />NOTCH WEB AT <br />t5^ <br />FIRST 2 COURSI <br />""' '.� ,APACITY = 805 # FOR 1 STRAP <br />= 1610 # FOR 2 STRAPS <br />1 PLY PRE-ENGINEERED TRUSS <br />SIMPSON HM9KT w/ (4) 1/4"1 1/2" SDS <br />SCREWS & (5)1/4" x 21/4" TITEN (IF TRUSS <br />IS 2 PLY INSTALL SIMPSON LGT2 w/ (16)16d <br />SINKERS AND (7)1/4"x2 1/4" TITEN = 2150 #) <br />BOND BEAM OR CAST IN PLACE BEAM <br />RETROFIT TRUSS DETAIL <br />N.T.S. <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (3) #6 X 4'%" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY WALL <br />USE (1) SIMPSON 1/2" HD TITEN (CENTERED) w/ <br />12 <br />S <br />MIN. 4" EMBEDMENT AT 16" O.C. <br />JACK TRUSS PROVIDED BY SEE <br />TRUSS COMPANY OR PLAN <br />2x6 #2 SYP @ 24" O.C. <br />ROOF SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />(5)12d NAILS IMPSON <br />2X6 TO 2X4 H2.5A w/ (10) — <br />8d NAILS <br />JACK TRUSS PROVIDED By—/ <br />TRUSS COMPANY OR 2X4 <br />#2 SYP @ 24" O.C. <br />4'-0" MAX SEE PLAN <br />2X4 SYP #2 CONT (MATCH TRUSS DEPTH ---� <br />NOTE: <br />SHED ROOF ENDS TO BE <br />GABLE ONLY, CORNERS <br />SHALL NOT BE FRAMED AS <br />HIP. <br />DESIGNED ONLY FOR THE <br />INSTALLATION OF SHINGLE <br />AND METAL ROOF FINISH <br />IF TRUSSES USED) W/ (2) #6 X 4%" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (2) 1/4" X 31/2" TAPCONS AT 16" <br />O.C. <br />SECTION @ ENTRY rL <br />SCALE: 3/4" = V-0" SS <br />i <br />GLASS BLOCK INSTALLATION NOTES <br />A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />MASONRY WALL. SEE PLAN FOR <br />REINFORCING. PROVIDE LOWER <br />D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 318" PLUS OR MINUS <br />HOOKED DOWEL <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />TYPE "S" OR 'IN". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />EXPANSION STRIP <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />20 ga. PANEL <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS <br />ANCHOR <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />W.W.M. AT PERIMETER <br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. <br />1/4" EXPANSION BOLT (2 <br />WHERE THIS CONDITION <br />E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />9 ga. PANEL PER ANCHOR) <br />#5 CONT. TOP &MID OCCURS <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />REINFORCING <br />WITH MIN. COVER 6'-0" <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />(EVERY OTHER <br />i <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />COURSE) EXPANSION STRIPSk <br />::j <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />° <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />, ° ; P <br />REINFORCING AS FOLLOWS: <br />* D T FURROW. <br />PLACE LOWER HALF OF MORTAR IN BED JOINT. ONO— <br />N <br />SEALANT <br />o o — — r <br />— <br />1�1 f�l 1�1�-- <br />. <br />-'`'_.;`; .�' - '-, ; <br />r <br />* PRESS PANEL REINFORCING INTO PLACE. <br />6" MIN. LAP SPLICE W/ <br />v � <br />COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL <br />SMOOTH, DO NO FURROW. <br />REINFORCING PANEL <br />r <br />°— <br />ir" r <br />F PLACE FULL MORTAR BED FOR JOINTS T REQUIRING PANEL REINFORCING - D NOT <br />U 0 E R O SNO R U 0 G 0 Q <br />III — III <br />GRADE -rr- <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. <br />6" MIN. LAP <br />G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />SPLICE <br />REMAIN FREE OF MORTAR. <br />NOTE: <br />M z <br />H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS <br />SEE GLASS BLOCK INSTALLATION NOTES. <br />T <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SEALANT <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />GLASS BLOCK DETAIL <br />\ ' (2) #5 REBAR. (I -STORY) <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) <br />GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />16" MIN. (1-STORY) (3) #5 REBAR. (2-STORY) <br />1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />20" MIN. (2-STORY) WITH MIN. 3" COVER EA. WAY <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />01 <br />J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />SECTION AT DEEP MONO FOUNDATION <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />REV. 07.28.21 SCALE: 3/4" = 1'-0" <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />INSTALLATION OF GLASS BLOCK. <br />L FILLED CELL PER <br />FOUNDATION PLAN <br />UNACCEPTABLE INSTALLTION <br />♦♦♦ DO NOT DO THIS ♦♦♦ <br />*# #5 #5 REBAR (TYP,) ♦♦♦ <br />,R ♦♦♦ ♦♦� <br />♦♦♦ 0 TD. 90" HOOK (TYP.) <br />YP.) ♦♦♦ ♦♦1 <br />E7 L: <br />♦♦♦♦♦ +2 NOTCt1 6♦Al ST COURSE <br />FHE ♦� ♦♦ <br />21x BOT. PLATE W/ (2)10d @ 6" O.C. _ <br />3!4" PLYWOOD DECKING GLUED <br />ATTACHED WALL SHEATHING TO <br />AND NAILED W/ 8d COMMON @ <br />2X BOTTOM PLATE W/ 8d @ 4" <br />6" O.C. EDGES AND 12" O.C. FIELD <br />O.C., 2 ROWS STAGGERED <br />2x BAND JOIST W/ FACE NAIL 10d <br />" <br />@ TOP & BTTM CHORD, AND (8) <br />FACE NAILS 10d @ TRUSS VERT. <br />WEB <br />METAL SEAT PLATE <br />NOTE: <br />LAP SHEATHING TO <br />BOTTOM OF BAND <br />JOIST TYPICAL <br />SIMPSON HGAM10KTA @ 12" O.C. <br />w! (4) 1/4x1 1/2" SDS SCREWS <br />_� <br />_ <br />INTO BAND JOIST & (4) 1/4"X2 3/4" <br />-- <br />TITEN INTO K.O. BLOCK <br />FILLED CELL INSTALLATION H RETROFIT FOR MISSING EMBEDDED STRAP <br />SCALE: N.T.S. <br />SS SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S. <br />SEE ARCH PLAN AND <br />PRE-ENG TRUSS DESIGN <br />SEE NOTE 1 BELOW <br />BRG WALL TYPE <br />PER PLAN I I <br />I i <br />F CHANNEL, <br />FASTENED PER <br />NOTE 2 BELOW-1-1T—L <br />CONT 2x4 NAILED TO <br />BLOCKING w/ 2-12d NAILS (**) <br />2x SUB FASCIA <br />ALUM DRIP EDGE <br />ALUM FASCIA <br />— 1-3/4" TRIM PAINTED <br />SS NAIL w/ 5/16" HEAD <br />— DIA. @ 24" O.C. <br />CONT VENTED OR SOLID SOFFIT <br />2x BLOCKING NAILED TO TOP <br />CHORD EVERY OTHER TRUSS <br />W/ 3-12d NAILS, TYP. (**) <br />1. G.C./ BUILDER TO VERIFY/PROVIDE SOFFIT MATERIAL SPAN CAPACITIES BASED <br />ON THE DESIGN PRESSURES SPECIFIED FOR COMPONENTS AND CLADDING <br />LISTED IN THE DESIGN CRITERIA ON SHEET SN. <br />2, FOR SOFFIT ATTACHMENT AT WALL (PER ALPHA ALUM. INC. FL# 16544 R5 FL <br />PRODUCT APPROVAL) F CHANNEL FASTENED TO: <br />- CMU w/ T NAIL .097" DIA. @ 24" O.C. w/ 5/8" MIN. EMBEDMENT <br />- WOOD w/ (3) 16 GA. 3/4"xl/4" CROWN STAPLES @ 24" MAX. O.C. IN DIAMOND <br />PATTERN <br />- - SUB FASCIA w/ 16 GA. 3/4"xl/4" CROWN STAPLE @ EACH GROOVE <br />SF01 STRUCTURAL SOFFIT <br />SCALE: 3/4" = V-0" (**) FOR ALUMINUM SOFFITS WITH SPANS <br />REV. 09.23.2021 > V-4", INSTALL MID SPAN BLOCKING PER <br />THE SOFFIT FL PA INSTALLATION CRITERIA <br />*REFER TO THE PRODUCT APPROVAL FOR INSTALLATION DETAILS.* <br />2�- <br />+ <br />+ + <br />+ + <br />+ + <br />+ <br />TRUSS <br />2X4 SYP <br />EACH TRUSS <br />CONNECTOR — <br />SEE LINTEL—� <br />SCHED. <br />PRECAST LINTEL <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />TRUSS AS SHOWN FOR O.H. UP TO Z-6" <br />4 * DOUBLE 2X4 SCAB FOR 2'-6" TO 4'-0" O.H. <br />G4FNOTH (2)10d NAILS @ 8' O.C. <br />TO TRUSS TOP CHORD <br />+ PLYWOOD SHEATHING <br />+ + <br />+ BLOCKING AS <br />+ REQUIRED TO <br />+ + <br />+ SUPPORT SOFFIT <br />I , IjJJV' SEE ELEVATION ' <br />FOR OVER HANG <br />(MAX. <br />SECTION @ ROOF EXTENSION M <br />SCALE: 3/4" = V-0" SS <br />CFF.HPFT n9 Ai <br />SIMPSON HTT4 w/ (18)10d x 1 <br />1/2" NAILS TO STUDS & (1) - <br />5/8" DIA. ALL THREAD ROD <br />EPDXIED w/ SIMPSON "SET" <br />EPDXY MIN. 6" EMBEDMENT F <br />3" MIN. EDGE DISTANCE <br />RETROFIT FOR MIS <br />MSTAM STRAP <br />SCALE:131Y - r <br />cr <br />Z <br />0 <br />fn <br />d <br />2 <br />o <br />LU <br />I— <br />U <br />FILL 1st 4 COURSES <br />SOLID W/GROUT <br />u <br />b: <br />r <br />FOR OVERHANGS BETWEEN OVER 1 1/2" <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER INSTRUCTIONS. ' ' • a . ' ' •. <br />e' <br />OVERHAN •.A. <br />a.' <br />RETROFIT WALL OVERHANG DETAIL (Ii <br />FOR OVERHANGS BETWEEN 3/4" TO 1 112" <br />NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR REQ'D. <br />1'-011 51-0 <br />1 <br />1 <br />NISH <br />>• 'of <br />e s #5 BAR <br />D. CENTERED W/ g <br />6 <br />1N TOP q <br />r e ; KNOCKOUT / c� <br />" ° CHAIR BLOCK <br />MONO FOOTING <br />SIZE AND REINF. PER PLAN <br />AND SECTION DETAILS - <br />CLEAN FILL <br />DIRT Z <br />°.• ° STANDARD q <br />90° HOOK N <br />#5 BAR IN <br />FILLED CELL, �, i - i • , <br />IN <br />STEMWALL FOOTING SIZE AND <br />MONO TO STEMWALL FOOTING REINF. PERLAN AND STEMWALL <br />SECTION DETAILS <br />SCALE: 3/4" = V-0" <br />ATE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJEC <br />)NTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. <br />EXISTING BOND BEAM. <br />DRILL 3/4"x5" MIN. HOLE SET BAR IN <br />EPDXY CAP TO PREVENT LEAKAGE <br />TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT <br />MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY ± 2") <br />#5x6' EMBEDDED INTO EXISTING BOND BEAM <br />FILL CELL FULL HEIGHT W/ <br />NON SHRINK GROUT. <br />#5x6' EMBEDDED INTO <br />EXISTING FOOTING <br />DRILL 3/4 x5 MIN. HOLE <br />SET BAR IN EPDXY <br />SAW CUT <br />EXISTING FOOTING A SECTION <br />1 SCALE: N.T.S. <br />RETROFIT FILLED CELL DETAIL <br />SCALE: N.T.S. <br />Ci <br />`. <br />CV <br />o <br />0 <br />B d-9 <br />n' <br />(n <br />> u.r <br />a o <br />ra <br />o,v <br />H �'o <br />°'�= <br />s 1% <br />a� <br />so•SO a. <br />to C. <br />= E <br />� o <br />0 <br />�a ?I� 0" <br />i <br />rt <br />o <br />bst3s�lia0'v0� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />rA <br />U <br />® <br />N O S' <br />=wog - <br />0 <br />U) <br />M # LL <br />4 <br />� <br />C W <br />J Li _ a <br />W <br />@'rn a <br />r Co o o <br />N O <br />Z <br />L IL <br />Nce) Z Q <br />N O U U <br />w <br />C3 CJ <br />z N <br />o g <br />N <br />z o � <br />a <br />Vi <br />N <br />z aCz <br />c� <br />o <br />LL <br />(II <br />� <br />W <br />V <br />0 <br />�(10 <br />w o <br />U � <br />LLJ <br />J <br />E <br />s <br />g <br />I <br />z�' <br />c CD <br />N 0 <br />o <br />9w <br />co <br />M <br />o <br />Z <br />< <br />< <br />N E <br />Q o <br />o <br />o0 <br />>9 <br />< <br />< N <br />oa <br />< <br />0< <br />w� <br />0. <br />N L� <br />r <br /><o <br />0 <br />Q <br />aZ <br />J <br />L <br />ry <br />CY <br />0 <br />U <br />m <br />0 <br />0z <br />Z <br />^ Q% <br />Nm <br /><W <br />In -' <br />aL`ni ' <br /><� <br />o <br />�Z <br />Z <br />5z <br />Q <br />w <br />a <br />NW <br />U <br />o� <br />O <br />¢X0 <br />< < <br />O <br />za <br />R <br />< <br />x <br />0 H <br />U9 <br />0 <br />O <br />= <br />> Ln <br />0 <br />111 <br />rn <br />B <br />c� <br />CT <br />^^Q <br />I..L <br />o <br />N <br />ca <br />a--+ <br />Ln <br />CO.0 <br />CV <br />0 <br />im <br />ri <br />N <br />L0 <br />T <br />Q <br />T <br />ui <br />Z <br />� <br />N <br />�; Ln <br />o <br />Z <br />rEo <br />E T <br />v <br />c <br />m <br />a <br />E <br />U <br />ai <br />Q p <br />JOB <br />NO: <br />22-06452 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SS <br />-I n�i � c�iin-nrrr- IF - It r r- ---� -�- <br />